Garrison Engineer South Diglipur
GARRISON ENGINEER SOUTH DIGLIPUR PROTHRAPUR PORT BLAIR 744105
REPAIRS OF INTERNAL ELECTRIFICATION, AC UNIS, REFRIGERATION, COOLING APPLIANCES AT AERIAL BAY AND MAYA BUNDER
2020_MES_368339_1
8805/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Port Blair
ALL BIDDERS ENLISTED WITH MES IN CLASS E AND CAT bi AND UNENLISTED BIDDERS MEET MES ENLISTMENT CRETERIA OF CLASS E AND CAT bi REFER NIT
6 documents required · 6 mandatory
₹500
Garrison Engineer South Diglipur
₹29,000
Yes
26 Oct 2020
11 Aug 2020
9 Sept 2020
11 Aug 2020
7 Sept 2020
25 Aug 2020
12 Aug 2020 - 17 Aug 2020
Amount
Taking down carefully old unserviceable point wiring for one light, socket or power etc including all fittings such as switches sockets, holders, light fittings, fan regulators etc and making good the disturbed surface of wall ceiling complete all as specified and as directed.
Material and labour for Point wiring with casing capping controlled by one switch with 1.50 Sqmm (nominal area) FRLS, PVC insulated 1100 volts grade multi stranded copper conductor single core unsheathed cable and FRLS, ISI marked, PVC insulated 1100 volts grade multi stranded copper conductor single core of size 1.50 Sqmm as earth continuity conductor connected to common earth dolly, with all fittings, ISI marked and accessories, the pipe shall be fixed with clamping and saddle including provision of mild steel terminal boxes/Sunken boxes of suitable size made with 1.6 mm thick mild steel sheet recessed in wall with a coat of black bituminous paint and providing of with 3mm thick Bakelite/PVC sheet ISI marked top cover , suitable for fixing of switches / sockets / regulators etc. fixed in recess of wall with brass chromium plated screws and cap washer complete all as specified and directed for One light point controlled by one way switch 5/6 Amps.
Description all as per item No. 2.00 herein before, but for One ceiling fan/Exhaust fan point controlled by one way switch 5/6 amps.
Description all as per item No. 2.00 herein before, but for One socket out let 5/6 amps point on the same board
Description all as per item No. 2.00 herein before, but for One socket out let 5/6 amps point on the independent board
Description all as per item No. 2.00 herein before, but for wiring with 2.5 sq mm single core copper conductor for one socket out let 15/16 amps point on the independent board
Supply and fix in repair socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and as directed.
Supply and fix in repair of socket outlet 2 in 1, 5 Pin 5/15 Amp multipurpose 230 volt flush type complete all as specified and as directed.
Supply and fix in repair switch piano flush type 5/6 amps single pole one way complete all as specified and as directed. Make : Anchor Penta/ Havells Reo
Supply and fix in repair switch piano flush type 15/16 amps single pole one way complete all as specified and as directed.
Supply and fix in repair ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and directed.
Material and labour for lamp holder, insulated body, with back plate suitable for batten/angle fittings complete all as specified and as directed.
Taking down sub main wiring of any type complete all as specified and as directed.
Material and labour for sub main wiring with 3 run of 4.00 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core cable of working voltage 1100 Volts grade with stranded copper conductor drawn in PVC rigid non- metallic conduit complete all as specified and as directed. NOTE : (i) Three run of submain wiring cable along with 25 mm PVC conduit pipe shall be measured as one unit length.
Material and labour for sub main wiring with 3 run of 2.50 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core cable of working voltage 1100 Volts grade with stranded copper conductor drawn in PVC rigid non- metallic conduit complete all as specified and as directed. NOTE : (i) Three run of submain wiring cable along with 25 mm PVC conduit pipe shall be measured as one unit length.
Taking down old MCB DBs with MCBs/Main switches/wooden boards etc complete all as specified and as directed.
Supply and fix Sheet metal enclosure for 8way Distribution Boards (DB’s), double door, single pole and neutral with 200 Amps rated bus bar, IP-43 protection suitable for fixing MCBs/isolators with and including blanking plates complete all as specified and as directed.
Supply and fix Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, single pole and neutral with 200 Amps rated bus bar, IP-43 protection suitable for fixing MCBs/isolators with and including blanking plates complete all as specified and as directed.
Supply and fix Sheet metal enclosure for 12 way Distribution Boards (DB’s), double door, single pole and neutral with 200 Amps rated bus bar, IP-43 protection suitable for fixing MCBs/isolators with and including blanking plates complete all as specified and as directed.
Supply and fix Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, Triple pole and neutral with 200 Amps rated bus bar, IP-43 protection suitable for fixing MCBs/isolators with and including blanking plates complete all as specified and as directed.
Supply and fix of MCB, Single pole and neutral 40 Amps, 240 Volts, ‘C’ curve, 10 kA all complete as specified and as directed.
Supply and fix MCB, Single pole, 5 to 32 Amps, 240 Volts, ‘C’ curve, 10 kA all complete as specified and as directed. Make: Havells DHMGBSPF06-32 or Equivalent Make
Supply and fix MCB TPN 63 Amps, 415 Volt, 10 kA, 'C' Curve rating, complete all as specified and directed.
Supply and fix MCB TPN 40 Amps, 415 Volt, 10 kA, 'C' Curve rating, complete all as specified and directed.
Material and labour for replacement for earthing complete with galvanised steel plate electrode of size 600x600x6.30mm thick buried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised 4 mm dia earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanised iron pipe 15mm bore (Light grade) for building LT wall panel all as directed including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm diameter MS bar funnel wire mesh 20 mm bore galvanised iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil with and including taking down the old one complete all as shown in electrical plate No 3 of SSR Part I 2009 including testing on completion all as specified and directed. Note: The Rate for Taking down the old unserviceable earthing shall be deemed to be included in the unit rate. Note: (i) Cost of GI earth wire and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item.
Supply and fix (in repair) Bell Ding dong AC 230 volt complete all as specified.
Supply and fix in repair/replacement energy efficient surface and wall mounted LED batten 20 Watts, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver. Diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including taking down old tube light fitting complete all as specified and as directed. Havells Cat No. : ENDURALINEARNEOBS20WLED840SPCWH or equal to Bajaj/Wipro/Crompton.
Supply and fix in repair/replacement energy efficient LED linear 10 Watts fitting with nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including taking down old tube light fitting complete all as specified and as directed. Make: Havells Cat No : NAKSHATRA/10W/W or equivalent in Bajaj/Crompton.
Supply and fix in repair/replacement energy efficient LED fitting 12 Watts Square in circle theme ceiling merging with luminaire. Make:Crompton Cat No : LCDRQ-12-CDL or equivalent in Bajaj/Philips
Supply and fix in repair/replacement energy efficient LED fitting 12 Watts Circular shape ceiling merging with luminaire. Make:Crompton Cat No :CDR-216-30-57-SL-NWH or equivalent in Bajaj/Philips
Supply and fix in repair/replacement energy efficient LED 2 ' X 2 ' fitting 30 Watts with nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including taking down old light fitting complete all as specified and as directed. Make: Crompton Cat No : LCTLRP-30-FO-CDL or equivalent in Bajaj/Crompton.
Supply and fix in repair/replacement energy efficient LED 4' X 1 ' fitting 40 Watts with nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including taking down old light fitting complete all as specified and as directed. Make: Crompton Cat No : LCTLRN-40-CDL-(1X4)
Supply and fix of Flame proof light fitting LED type 20 Watts complete with LED tube and all accessories all as specified. Make: Crompton Cat No : EXTN2LT8-16/20)
Supply and fix LED Lamp 1 X 09 Watts retrofit type. Make Surya or equivalent
Supply and fix in repair/replacement energy efficient LED fitting for 100mm ceiling 40 Watt with nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including taking down old light fitting complete all as specified and as directed. Make:Crompton Cat No : LCRTTZN-40-CDL
Supply and fix in replacement of LED Adore lamp 0.5 Watts warm coloured all as directed.
Disconnecting of electric connection from ceiling rose and taking down the ceiling/exhaust fan any type sweep for carrying out repairs / rewinding/ replacement/cleaning etc and refixing the same in position after repairs including fixing/ labour only for replacement of unserviceable parts , greasing, oiling etc and replacement of minor rubber parts, connectors, bolts, nuts etc including replacing of unserviceable flexible connection wire etc upto 1 metre length complete all as specified. Note: - The new parts required shall be supply only under relevant items herein after and shall be measured and paid separately) A BOO shall be conveyed for find out defective spares after opening the forms.
Material and labour for rewinding of coils of ceiling fan of any make and sweep by following ways. (i) Taking out complete coils from the rotor of ceiling fan (ii) Rewinding of ceiling fans of any sweep by using super enameled copper wire and turns as per existing gauge and approved quality including insulation paper, varnishing, drying and refitting the ceiling fan and testing the speed complete all as directed.
All as per item No. 38 here in before, but of exhaust fan of sweep 250 mm to 450 mm complete all as specified.
Supply only parts/components of ceiling fan, Gun metal bush bearing as per existing make and size complete all as specified and as directed. (Note: Parts and components supplied under this item shall be fixed under items herein before) .
Description all as per Item No. 40 herein before, but Ball bearing (Make : NBC/SKF/ABC/ANT)
Description all as per Item No. 40 herein before, but Paper condenser 2.5 MFD (Make : USHA/SHARITTA/KELTRON /UNIVERSAL).
Description all as per Item No. 40 herein before, but Paper condenser 3.0 MFD (Make: USHA/SHARITTA/KELTRON /UNIVERSAL).
Supply and fix (in repair) step type electronic fan regulator, AC, 230 volt complete all as specified
Supply only Gun metal bush bearing parts / components of exhaust fan of existing make and size complete all as specified and as directed.
Description all as per Item No. 45 herein before, but Ball bearing (Make : NBC/SKF/ARC/ANT)
Description all as per Item No. 45 herein before, but Paper condenser 4 MFD (Make : USHA/SARDA/KELTRON/UNIVERSAL).
Taking down the existing unserviceable storage type electric water heater (geyser) of any make, for 25 Ltr capacity, installed at different location including disconnecting, taking down opening all parts/accessories for inspection, cleaning, decaling, refixing serviceable parts, replacing unserviceable parts installed at old location and reconnection, testing complete all as directed by Engineer-in-Charge.
Supply only heating element round type of geysers including rubber washer for the following capacity. (Make: Racold/Bajaj) for 1500 Watts capacity.
Description all as per Item No. 49 herein before, but 2000 Watts capacity.
Supply only PVC connection pipe with brass unions at both ends, 450mm long 15mm bore (for incoming cold water) all as specified and as directed.
Supply only chromium plated copper connection pipe 450mm long with two brass adopters washers and connecting up complete all as specified and directed.
Supply only apparatus plate suitable for 25 ltrs capacity geyser. (Make: Bajaj / Racold)
Supply only thermostat (ISI Marked) for 25 Liters capacity Geyser. (Make: Elcon or Equivalent ISI marked).
Supply and fix Non-return valve, ISI marked, brass, 15mm bore after taking out defective/ unserviceable one complete all as specified and directed (Make : ZOLOTO/TATA/SCUD)
Supply and fix in replacement hole fastener 10 mm dia, 100 mm long including nut and washer complete all as specified.
Supply and fix in replacement rubber gas Kit suitable for 25 ltrs capacity geyser (as per sample) complete all as specified.
Supply and fixing in repair/replacement Three phase Static Energy Meter of accuracy class 1.0,3 X 240 V 50 Hz with backlit LCD display, of rating, 10-60A, Box complete (Measures and display KWH, Volt, VI, KW, PF , HZ, Last month history of KWH and MD in KW with special features like TOD, tamper logging, optical communication port and display in absence of power. Make: HPL Cat No. TPPB1521130000ME01
Supply and fixing in repair/replacement Single phase Static Energy Meter of accuracy class 1.0,1 X 240 V 50 Hz with backlit LCD display, Optical port and RS 234 port display of rating 5 to 30 amp with DMLS compliance as per IS 15959 of rating , 10-60A, 240 V, Box complete (Measures and display KWH, Volt, VI, KW, KVA, PF , HZ, Six month history of KWH and MD in KW with special features like TOD, tamper logging, optical communication port and display in absence of power Make-HPL Cat No TPPB1521130000ME01
WATER COOLERS Taking down defective sealed compressor from the unit and supply and fix factory reconditioned compressor obtained for the exchange of old compressor including cleaning the refrigeration circuit with appropriate cleaning agent flushing through with CO2/N2, brazing the line, pressure testing rectification of leakages, dehydrating, vacumising, charging of R 134A gas, replacement of copper pipe, copper strainer, topping up compressor oil including to and fro transportation of the unit to the workshop testing & commissioning of 40/80 Ltrs capacity water coolers.
Material and labour for cleaning including cleaning the system, flushing through with CO2/N2 removal of complete dirt, oil brazing the line, pressure testing, rectification of leakages, dehydrating, vacumising, charging of R-12/R-22 gas, replacement of copper pipe, copper strainer, topping up compressor oil, testing & commissioning the water coolers of capacity 40/80 Ltrs
Supply and fix in replacement relay assembly suitable for water cooler of any capacity as per existing complete all as specified. (Make : Sriram / Sarada)
Supply and fix in replacement thermostatic switch suitable for water cooler of any capacity as per existing complete all as specified. (Make: INDOFOSS / RANUTROL)
Supply and fix in replacement capacitor suitable for water cooler of any capacity as per existing complete all as specified. (Make : SARADA / UNISTAR)
Supply and fix in replacement overload protector suitable for water cooler of any capacity as per existing complete all as specified. (Make : SRIRAM/KIRLOSKAR)
Supply and fix in replacement fan motor with fibre blade suitable for water cooler of any capacity complete all as specified. (Make : AUF/FREEFLOW)
Supply and fix in replacement PVC hose connections, for water out let pipes including fixing by proper clips complete all as specified.
Supply and fix in replacement PVC float valve of 15mm bore (including ball)suitable for water cooler of any capacity as per existing complete all as specified.
Supply and fix in replacement capillary tube 1/32" including brazing for water cooler of any capacity complete all as specified.
Supply and fix in replacement wiring kit for water cooler of any capacity complete all as specified.
Supply and fix inlet in replacement PVC water connection as main inlet connection suitable for water cooler of any capacity as per existing complete all as specified.
Supply and fix in replacement inlet /outlet rubber pipe suitable for water cooler size 1/2" complete all as specified.
REFRIGIRATORS Taking down defective sealed compressor from the unit and supply and fix factory reconditioned compressor obtained for the exchange of old compressor including cleaning the refrigeration circuit with appropriate cleaning agent flushing through with CO2/N2, brazing the line, pressure testing rectification of leakages, dehydrating, vacumising, charging of R134A gas, replacement of copper pipe, copper strainer, topping up compressor oil including to and fro transportation of the unit to the workshop testing & commissioning of 165 capacity. Make: LG / WHIRLPOOL / USHA (TECUMSHA)
Material and labour for gas charging including cleaning the refrigeration system, flushing through with CO2/N2 removal of complete dirt, oil brazing the line, pressure testing, rectification of leakages, dehydrating, vacumising, charging of R134A gas, replacement of copper pipe, copper strainer, topping up compressor oil, including to and fro transportation of the unit to the work shop testing & commissioning the refrigerators of capacity 165 to 210 Ltrs
Supply and fix in replacement relay suitable for Refrigerator / deep freezer of any capacity as per existing model complete all as specified. (Make : Sriram / Indfoss / Danfoss)
Supply and fix in replacement overload protector suitable for Refrigerator / deep freezer of any capacity as per existing model complete all as specified.
Supply and fix in replacement thermostatic switch of auto de-frost suitable for refrigerator any type and capacity and any model complete all as specified.
SPLIT TYPE ACs Carrying out leak test on all joints of the tubing of ACs of any capacity by pressurizing the system by dry nitrogen gas, carrying out air purging by vacuum pumps, checking any leak with soap water and recharging with fresh refrigerant gas, testing and commissioning of ACs as per manufacturer's manual and as directed.
Taking down the AC unit of any capacity by disconnecting all electrical and piping connections and performing following maintenance tasks. (a) Removal of dust from the outer body with the help of a blower. (b) Cleaning the condenser coils with water and cleaning agent/soap solution and decaling. it. (c) Painting the base tray with one coat of black enameled paint. (d) Cleaning of air filter of with vacuum cleaner or washing the filter in lukewarm water with detergent. (e) Cleaning of anti allergy and triple filter and drying the filter in direct sunlight for 2 hrs. (f) Cleaning of plasma filter with vacuum cleaner or washing the filter in lukewarm water with detergent and drying the filter in shade. (g) Cleaning of micro protection filter with vacuum cleaner only. (h) Cleaning of indoor unit with a soft, dry cotton cloth. (j) Checking all connections including functioning of relays, capacitors, overload protectors, thermostats, industrial socket (Metal clad) and circuit breaker.
Taking down the AC Unit of any capacity (both indoor & outdoor units) by disconnecting electrical connections and piping, shifting to new location and reinstalling with necessary additions/alterations, fittings and fixtures, making good the disturbed surfaces complete all as directed.
Supply and fix Copper pipe line heavy duty upto 5/8" dia with puff insulation and flair nuts from indoor to outdoor Split Type AC of 1.5/2 TR Capacity all as specified and directed.
Supply and fix (in repairs) of capacitor (conforming to IS:2993-1975) AC 230 Volts in plastic container 45/4.0 mfd all as specified and as directed.
Supply and fix (in repairs) of capacitor (conforming to IS:2993-1975) AC 230 Volts in plastic container 55/6.0 mfd all as specified and as directed.
Supply and fix (in repairs) condenser unit complete set suitable for 1.5 Ton split type AC unit including removing the existing unit complete all as specified.
Supply and fix (in repairs) Fan blade suitable for 1.5 Ton split AC all as specified and as directed.
Supply and fix (in repairs) blower motor capacitor 6 MFD all as specified and as directed.
Repair/Replacement of remote control unit along with remote control holder suitable for Split type ACs complete all as directed and as per manufacturer`s specifications.
Supply and fix in replacement of new swing motor as per existing Model/Make for split type AC 1.5/2 TR complete all as specified and directed.
Supply and fix in replacement of 3 core copper PVC insulated wire of size 70/.0076 complete all as specified and directed.
Disconnecting and taking down burnt compressor of capacity 1.5 TR from split AC unit and supply and install the new compressor 1.5 TR capacity duly filled with gas as per existing model and size and testing also complete all as specified and directed by Engineer-in-charge. Make:- LG / Voltas Note:- (1) Guarantee card with original purchase voucher of the original manufacturer shall be produced before payment. (2) Freon Gas measured and paid separately under the relevant item of sch 'A' all as specified and directed.
Description all as per item No. 90 herein before, but split type AC 2 TR capacity complete all as specified and directed by Engineer in charge.
Supply and fix Voltage Stabilizer 4 KVA, 170-270 Volts, Model No: VG-400 suitable for 1.5 Ton split AC all as specified and as directed. Make: V-Guard.
Supply and fix Voltage Stabilizer 5 KVA, 170-270 Volts, Model No: VG-500 suitable for 1.5 Ton split AC all as specified and as directed. Make: V-Guard.
Supply and fix Voltage Stabilizer 2 KVA,150-280 Volts, Model No: VG-150 suitable for 40/80 Ltrs capacity of water cooler all as specified and as directed. Make: V-Guard.
Supply and fix of AC fixing bracket suitable for 2/1.5 Ton split AC all as specified and as directed.
Supply and fix (in repairs) PCB Board suitable for 1.5 Ton split AC all as specified and as directed
Supply and fix (in repairs) Remote sensor Board suitable for 1.5 Ton split AC all as specified and as directed
Supply and Charging of refrigerant gas R-22 in cooling appliances after dehydration all as per standard practice testing for proper cooling effect and satisfactory performance complete all as specified and as directed (Make : Mafron / Floron)
Supply and Charging of refrigerant gas R134A in cooling appliances after dehydration all as per standard practice testing for proper cooling effect and satisfactory performance complete all as specified and as directed (Make : Mafron / Floron)
Supply and Charging of refrigerant gas R 32 in cooling appliances after dehydration all as per standard practice testing for proper cooling effect and satisfactory performance complete all as specified and as directed (Make : Mafron / Floron)
B N ENGINEERING WORKS
MGP Enterprises
AK TRADERS
SRI HARSHITA ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .