Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC HOUSE NO 41 WARD NO 09 ARYA SAMAJ GALI UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L1 | Accepted-AOC Being a lowest tenderer | |
| 2 | L2₹25.3 L+₹1.1 L (4.68%)Rejected-Finance NO 6 1 ALAGAR PERUMAL KOIL MAIN STREET VADAPALANI CHENNAI 600 026 | CHENNAI | CHENNAI | TAMIL NADU | 600026 | L2 | Rejected-Finance Being a 2nd Lowest bidder | |
| 3 | L3₹25.9 L+₹1.7 L (6.95%)Rejected-Finance | L3 | Rejected-Finance Being a 3rd Lowest bidder | |
| 4 | L4₹27.5 L+₹3.3 L (13.6%)Rejected-Finance 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | L4 | Rejected-Finance Being a 4th Lowest bidder | |
| 5 | L5₹30.0 L+₹5.8 L (24.1%)Rejected-Finance 1 A BASEMENT 30 31 RAJA HOUSE NEHRU PALACE NEW DELHI 110 019 | SOUTH EAST | DELHI | 110019 | L5 | Rejected-Finance Being 5th Lowest bidder |
| Sl No | Description | Qty | Unit | MONA GENERATOR SEVICES PVT. LTD. L5 | EVEREST ENGINEERING WORKS L4 | M/S.RANGA AND CO L3 | Veera Electrical L2 | M/S N K POWER SYSTEMS AND PROJECTS L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, Install, testing & commissioning of 200 KVA, Diesel Generator set model No KG4-200WSI , water cooled diesel engine model No 6K1080ETA 4G2 developing 250 BHP at 1500 RPM, 3 Phase, 415 V, 50 Hz, fuel tank cap 400 ltrs, standard control panel in and including indoor type AMF Panel 200 KVA DG set, four stroke electric start, six cylinders as per IS : 8528 Part 10 as per approved CPCB IV Norms confirming to IS : 10002/ BS:5514/ ISO 3046.
Engine Make: Cummins / Kirloskar / Caterpillar / Greaves.
Alternator Make: Stamford / Kirloskar / Electric / Crompton / Jyothi Areva / C&S Electricals / Leroysomer | 1 | Each | 29,06,262 ₹29,06,262 | 26,50,000 ₹26,50,000 | 25,07,000 ₹25,07,000 | 23,77,880 ₹23,77,880 | 23,39,900.73 ₹23,39,900.73 Lowest |
| 1.01(i) Engine :- (a) Diesel engine shall be turbo charged after colled multi-cylinder inline type with mechanical fuel injection system. (b) The engine shall be enclosed in an enclosure to make it work silently (with permissible noice level as per CPCB norms) without any deradation in its performance. Coolant 28.9 ltrs capacity. (c) The fuel shall be used high speed diesel oil (HSD) as per IS 1460. (d) Suction of air shall be from outdoor for ventilation and exhaust flue gasses will be let out to outside atmosphere, condensate traps shall be provided on the exhaust pipe. (e) Filter shall be dry type air filter with replaceable elements. (f) The engine shall have closed loop lubricating system. No moving parts shall require lubrication by hand prior to the start of engine or while it is in operation. (g) The engine shall be automatic electric starting by 12 V DC starter motor system. (h) The engine shall be fitted with electronic governor suitable for class A1 as per IS:10000. | ||||||||
| 1.02(ii) Alternator :- Alternator with rated output of 200 KVA suitable for continuous operation at 1500 RPM developing 415 volts at 0.8 p.f (lag) suitable for 50 Hz, three phase, 4 wire system, Insulation class 'H'. The alternator shall be brushless type drip proof, screen protected as per IP-23 self-excited & self-regulated. The alternator will be suitable for tropical climate and shall confirm to IS : 4722. The sailient features of the alternator following types are as under :- (a) +/- 1% voltage regulation in static conditions. (b) IP 23 protection with class 'H' insulation. (c) Permissible overload of 10% for one hour in 12 hours of operation. | ||||||||
| 1.03(iii) Coupling & Mounting Arrangement :- (a) The engine and alternator shall be directly coupled by means of self-aligning flexible flange coupling to avoid misalignment. (b) The coupling shall be provided with protecting guard to avoid accidental contract. | ||||||||
| 1.04(iv) Fuel Tank : The fuel tank of 400 ltrs cap shall be provided with DG Set. The tank shall be completed with an outlet, a drain plug an air vent, an air breather and necessary piping. Fuel tank shall be inside the acoustic enclosure. | ||||||||
| 1.05(v) Battery & Battery Charger : 1 No 12 Volt batteries complete with all leads, terminals and stand shall be provided with DG set. Each battery shall have sufficient cap to give 10 nos successive starting impulse to the engine. | ||||||||
| 1.06(vi) AMF Control Panel : Automatic mains failure (AMF) indoor type control panel shall be able to start up the DG Set and transfer the load on to the DG Set on main failure without requiring any human intervention. Similarly on restoration of main supply it shall be able to transfer the DG Set automatically alongwith provision of by pass arrangements of main supply. The AMF panel shall be with in enclosure fabricated from min 2 mm thick CRCA sheet steel duly pre treated aesthetically finished and shall be dust and vermin proof. The AMF panel shall have the following accessories : (a) Micro precessor based relay with composite meter for digital display (i) Generator voltage/AC main voltage (ii) Generator current (iii) Power factor (iv) Frequency (v) Energy (KWH) (vi) Three attempt engine start/Engine cranking relay (vii) On delay time for load change over (viii) On delay time for engine shut off (b) Mode selector for setting the panel on any one position such as "Off" or "Auto" or "Manual" or "Test" (c) Engine ON-OFF switch (push button type) (d) MCCB of capacity FP suitable to alternator 415 volts - 1 No (e) Any other switch, instrument, relay or contactor etc. essential for smooth and trouble free functioning of DG set with AMF Panel. | ||||||||
| 2.00 | Dismantling/taking down BER DG set of any model / make size 200 KVA cap after necessary removal of electrical, AMF Panels connections and electric connections from existing location at site including shifting /transporting to MES store yard for depositing all as directed. | 1 | Each Job | 10,855 ₹10,855 | 20,000 ₹20,000 | 7,700 ₹7,700 Lowest | 18,000 ₹18,000 | 9,373 ₹9,373 |
| 3.00 | Supply and laying LT UG XLPE insulated armoured heavy duty electric, power cable with aluminium conductor, 1100 volts grade of size 120 Sqmm 3.5 Core laid in trenches, fixed to poles, panels complete all as specified and as directed. | 50 | RM | 813 ₹40,650 | 616 ₹30,800 Lowest | 680 ₹34,000 | 855 ₹42,750 | 640 ₹32,000 |
| 4.00 | Earthing complete with galvanised steel earth plate electrode 600x600x6mm burried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.5mtr below normal ground level connected to the Galvanised iron strip 32x6mm size by means of bolts ,nuts,check nuts and washers of galvanised iron and 32x6mm GI strip procted by provision of GI light grade pipe 40 mm bore incl provision of concrete pit in PCC1:2:4 type B-1 , using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kgs /Sqm and 6mm dia bar handle, excavation and earth work in any type of soil, charcoal dust and salt light grade GI watering pipe 20 mm bore with funnel and wire mashand medium grade GI protection pipe 15mm bore 5 Mtr long and GI strip upto main earthing of pole complete all as shown in electrical plate No 3 of MES Sch 2009 Part-I complete all as specified and directed. Loc : DG Set Body - 02 Nos, DG Set Neutral - 02 Nos & AMF Panel - 02 Nos | 6 | Each | 6,828 ₹40,968 | 7,500 ₹45,000 | 6,080 ₹36,480 | 15,300 ₹91,800 | 6,000 ₹36,000 Lowest |
Tender Value
₹30.4 L
EMD Value
₹60,800
Closing Date
26 Aug 2025, 6:00 pmClosed
COMMANDER WORKS ENGINEER
COMMANDER WORKS ENGINEERS Pallavan Salai Chennai 600 002
SPECIAL REPAIR / REREPLACEMENT OF 200 KVA DG SET WITH AMF PANEL AGAINST BER AT OTA UNDER GE STM CHENNAI
2025_MES_723179_1
86595/E8
Open Tender
Miscellaneous Works
Item Rate
GE STM
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE STM
₹60,800
Yes
26 Sept 2025
29 Jul 2025
28 Aug 2025
29 Jul 2025
26 Aug 2025
12 Aug 2025
Amount
Supply, Install, testing & commissioning of 200 KVA, Diesel Generator set model No KG4-200WSI , water cooled diesel engine model No 6K1080ETA 4G2 developing 250 BHP at 1500 RPM, 3 Phase, 415 V, 50 Hz, fuel tank cap 400 ltrs, standard control panel in and including indoor type AMF Panel 200 KVA DG set, four stroke electric start, six cylinders as per IS : 8528 Part 10 as per approved CPCB IV Norms confirming to IS : 10002/ BS:5514/ ISO 3046. Engine Make: Cummins / Kirloskar / Caterpillar / Greaves. Alternator Make: Stamford / Kirloskar / Electric / Crompton / Jyothi Areva / C&S Electricals / Leroysomer
(i) Engine :- (a) Diesel engine shall be turbo charged after colled multi-cylinder inline type with mechanical fuel injection system. (b) The engine shall be enclosed in an enclosure to make it work silently (with permissible noice level as per CPCB norms) without any deradation in its performance. Coolant 28.9 ltrs capacity. (c) The fuel shall be used high speed diesel oil (HSD) as per IS 1460. (d) Suction of air shall be from outdoor for ventilation and exhaust flue gasses will be let out to outside atmosphere, condensate traps shall be provided on the exhaust pipe. (e) Filter shall be dry type air filter with replaceable elements. (f) The engine shall have closed loop lubricating system. No moving parts shall require lubrication by hand prior to the start of engine or while it is in operation. (g) The engine shall be automatic electric starting by 12 V DC starter motor system. (h) The engine shall be fitted with electronic governor suitable for class A1 as per IS:10000.
(ii) Alternator :- Alternator with rated output of 200 KVA suitable for continuous operation at 1500 RPM developing 415 volts at 0.8 p.f (lag) suitable for 50 Hz, three phase, 4 wire system, Insulation class 'H'. The alternator shall be brushless type drip proof, screen protected as per IP-23 self-excited & self-regulated. The alternator will be suitable for tropical climate and shall confirm to IS : 4722. The sailient features of the alternator following types are as under :- (a) +/- 1% voltage regulation in static conditions. (b) IP 23 protection with class 'H' insulation. (c) Permissible overload of 10% for one hour in 12 hours of operation.
(iii) Coupling & Mounting Arrangement :- (a) The engine and alternator shall be directly coupled by means of self-aligning flexible flange coupling to avoid misalignment. (b) The coupling shall be provided with protecting guard to avoid accidental contract.
(iv) Fuel Tank : The fuel tank of 400 ltrs cap shall be provided with DG Set. The tank shall be completed with an outlet, a drain plug an air vent, an air breather and necessary piping. Fuel tank shall be inside the acoustic enclosure.
(v) Battery & Battery Charger : 1 No 12 Volt batteries complete with all leads, terminals and stand shall be provided with DG set. Each battery shall have sufficient cap to give 10 nos successive starting impulse to the engine.
Dismantling/taking down BER DG set of any model / make size 200 KVA cap after necessary removal of electrical, AMF Panels connections and electric connections from existing location at site including shifting /transporting to MES store yard for depositing all as directed.
Supply and laying LT UG XLPE insulated armoured heavy duty electric, power cable with aluminium conductor, 1100 volts grade of size 120 Sqmm 3.5 Core laid in trenches, fixed to poles, panels complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode 600x600x6mm burried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.5mtr below normal ground level connected to the Galvanised iron strip 32x6mm size by means of bolts ,nuts,check nuts and washers of galvanised iron and 32x6mm GI strip procted by provision of GI light grade pipe 40 mm bore incl provision of concrete pit in PCC1:2:4 type B-1 , using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kgs /Sqm and 6mm dia bar handle, excavation and earth work in any type of soil, charcoal dust and salt light grade GI watering pipe 20 mm bore with funnel and wire mashand medium grade GI protection pipe 15mm bore 5 Mtr long and GI strip upto main earthing of pole complete all as shown in electrical plate No 3 of MES Sch 2009 Part-I complete all as specified and directed. Loc : DG Set Body - 02 Nos, DG Set Neutral - 02 Nos & AMF Panel - 02 Nos
Veera Electrical (BID ID -3398774)
M/S.RANGA AND CO (BID ID -3398804)
EVEREST ENGINEERING WORKS (BID ID -3406908)
MONA GENERATOR SEVICES PVT. LTD. (BID ID -3398778)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .