Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹19.7 LAccepted-AOC PLOT NO 242 NEAR MEERA APPARTMENT M P NAGAR ZONE 2 BHOPAL 462011 | BHOPAL | MADHYA PRADESH | 462011 | ₹19.7 L | L-1 | Accepted-AOC The bidder is the L-1 bidder |
| 2 | Rejected-Technical | - | - | Rejected-Technical The bidder is not the L-1 bidder |
| 3 | Rejected-Technical | - | - | Rejected-Technical The bidder is not the L-1 bidder |
| 4 | Rejected-Technical WARD NO 14 MURALIYA BAG BURHAR DISTT SHAHDOL M P 484110 | SHAHDOL | MADHYA PRADESH | 484110 | - | - | Rejected-Technical The bidder is not the L-1 bidder |
| 5 | Rejected-Technical | - | - | Rejected-Technical The bidder is not the L-1 bidder |
Tender Value
₹37.9 L
EMD Value
₹47,400
Closing Date
19 Jan 2026, 5:00 pmClosed
Staff Officer Civil SECL Sohagpur Area
Office of Staff Officer Civil SECL Sohagpur Area, GM Office, Dhanpuri, Distt. Shahdol , M.P. - 484114
Repair and maintenance of water supply external pipeline and operation assistance of water supply system of Rungta Colony under Burhar Sharda Sub Area (For one year)
2026_SECL_350590_1
SECL/SGP/SO(C)/ e-TENDER/2025-26/63 dtd. 05.01.2026
Open Tender
Water Supply/ Sanitation Works
Percentage
365 days
Sohagpur Area
As Per NIT
3 documents required · 3 mandatory
₹47,400
16 Feb 2026
7 Jan 2026
21 Jan 2026
7 Jan 2026
19 Jan 2026
8 Jan 2026
7 Jan 2026 - 14 Jan 2026
Item Description/ Heading
Providing, Laying, Jointing & field testing of HDPE pipes (High Density Polyethylene Pipes) confirming to IS 4984/14151/12786/13488 with necessary jointing material like mechanical connector of jointing pipes by heating to the ends of pipes with the help of Teflon coated electric mirror/ heater to the required temperature and then pressing the ends together against each other, to form a monolithic & leak proof joint by thermosetting process. It may be required to be done with Jack/ Hydraulic Jacks/ Butt fusion machine. (50 mm & above fusion jointed & below 50mm mechanical jointed). (110 mm dia), 8Kg/ sq.cm :
Making connection of G.I. distribution to HDPE branch of different sizes by providing and fixing tee, including cutting and threading the pipe etc., all complete as per instruction of engineer-in-charge.
Providing and fixing gun metal non- return valve of approved quality (screwed end) : 50 mm nominal bore Vertical.
Providing and fixing gun metal non- return valve of approved quality (screwed end) : 80 mm nominal bore Vertical.
Providing and fixing following check (non-return) valves ClassI, confirming to IS-778/1984 (Reaffirmed 2005) female ends, tested to 21.09 kg/sq.cmt. (Flanged), Flanged (100mm dia )
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work: 80 mm dia nominal bore.
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work: 50 mm dia nominal bore.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work : 50 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work : 25 mm nominal dia Pipes
Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: Up to 150 mm diameter.
Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge :Above 40 mm nominal bore
Providing and fixing G.I. Flange with M.S nut bolts & rubber packing for 80 mm dia. pipe etc., all complete as per instruction of Engineer-In-Charge.
Providing and fixing G.I. Flange with M.S nut bolts & rubber packing for 50 mm dia. pipe etc., all complete as per instruction of Engineer-In-Charge.
Providing contractual assistance for operation and maintenance of water supply of Rungta colony by deploying valveman - 03 nos, pump operator - 03 nos and 02 Fitter all Semiskilled etc., all complete as per instruction of Engineer-In-Charge.
Providing contractual assistance for Lifting and lowering of submersible pumps by deplaying unskilled manpower minimum 4 nos for each time etc., all complete as per instruction of Engineer-In-Charge.
Total impact of GST for the purpose of CTC
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_363343.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.04 MB
Tendernotice_2.pdf
PDF • 0.54 MB
Tendernotice_3.pdf
PDF • 1.22 MB
BOQ_363343.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .