Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹25,800
Closing Date
6 Jun 2024, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
S.E, EUCC-V, LESA, Cis-gomti,Lucknow
Room NO.61, LESA, Bhawan Near Residency Park, Kaiserbagh, Lucknow.-226018
61/EUCC-V/LESA/2023-24
2024_MVVNL_920781_1
61/EUCC-V/LESA/2023-24
Open Tender
Electrical Works
Fixed-rate
60 days
33/11 kv s/s Gopramau
As per tender specification
2 documents required · 2 mandatory
₹3,540
A/c. No. 10101985364, IFSC CODE No.SBIN0003347,SBI
₹25,800
25 Jun 2024
30 Mar 2024
6 Jun 2024
30 Mar 2024
6 Jun 2024
30 Mar 2024
Amount
Dragging, loading, carriage and unloading of following store materials with proper stacking from ESC Daliganj to JE dumps store and from JE dump store to work site within municipal area.
11 KV 3x185 sq mm XLPE cable
11 KV 3x185 sq mm O/D+I/D
11 KV 3x185 sqmm St/Th
ST pole 11 mtr long
M.S.channel 100x50 sq mm
M.S.Angle 65x65x6 sq mm
11 kv pin insulator
M S Earthing Rod 20x2500 mm
11 kv pin with nut
1x240 LT XLPE Cable
ST pole 11 mtr long
M.S.Channel 100x50 sq mm
11 kv Disc insulator T&C 45 KN
Stay wire 7/10 SWG
M.S. Angle Iron 65x65x6mm Bracing. 2 no. 4300 mm
M.S. Angle Iron 65x65x6mm for Cable Dropper
Disc fitting T&C Type 45 KN
M S Earthing Rod 20x2500 mm
Stay Set 16x1800 Complete
ACSR Rabbit Conductor
8.5 M PCC long
11 KV V type steel cross arm angle 65x65x6mm
11KV pin insulator
11KV Pin with Nut
M S Earthing Rod 20x2500 mm
8.5 M long PCC
M.S. channel 100x50mm
11KV pin insulator
11KV Disc insulator T&C
Stay wire 7/10 SWG
11KV Pin with Nut
Disc fitting T&C
M S Earthing Rod 20x2500 mm
Stay Set 16x1800 Complete
PCC Pole 8.5 Mt Long
11KV Disc Insulator T&C Type 45 KN
Disc Fittings T&C Type
11 KV Pin Insulator
11KV Pin with Nut
M.S. Angle Iron 65x65x6mm Bracing. 2 no. 4300 mm
Top chanel 100X50MM
Stay Set 16x1800 Complete
Stay Wire 7/10 SWG
M S Earthing Rod 20x2500 mm
MS Angle 65X65X6 MM
GI wire 8 Swg
Fabrication & erection of single pole for 11 KV line on 8.5 M long PCC Pole with fixing of necessary clamp & other acessories like 1 no. Channel cross arm, Danger board, barbed wire etc. contractor shall provide, necessary clamps, F-Bracket etc. as per RESPO norms.
Fabrication & erection of 11 KV cable exposure type double pole with the provission of separate bus bar for each cable with fixing of necesory clamps and other acessories like danger board,number plate,barbed wire, 9 no. pin insulators with pins,2 no. channels 125x65 mm (1600mm each),1 no.MS channel 125x65mm(3200mm in length) and 2 no.MS angle 65x65x6 mm (each 3200mm in length ) for supporting the hoisting of cable & poles.its jumpering by single core PVC aluminium cable with proper size of lug. (all material arranged by contractor except steel,pole,PVC aluminium cable & insulator).as per RESPO norms.
End Type Double Pole- Fabrication, erection, of double pole of end terminations with one side cable exposure for 11 KV line on 11 M long ST pole with fixing of necessary clamps & other accessories like disc insulator, 1 no. top chennel 125×65 mm - 3.20M & 1 no. gaurding angle and 1 no. X bracing,disc fittingits, 11kv pin with pin insulator ,danger board,number plate,barbed wire,jumpering by PG clamp 4 no stay complete work (all material arranged by contractor except steel,insulator,disc insulator with fitting & pole).as per RESPO norms.
11 KV Sectional Double on PCC Pole-Fabrication, erection, of double pole for 11 KV line on 8.5 M long PCC pole with fixing of necessary clamps & other accessories like ,disc insulator, 1 no. top chennel 125×65 mm - 3.20M & 1 no. gaurding angle and X bracing,disc fittingits,11 kv pin with pin insulator, barbed wire,jumpering by PG clamp 4 no Stay set etc.(all material arranged by contractor except steel,insulator,disc insulator GI Pin, Disc Fitting & pole).as per RESPO norms.
11 KV Single Sectional on PCC Pole-Fabrication, erection, of single pole for 11 KV line on 8.5 M long PCC pole with fixing of necessary clamps & other accessories like ,disc insulator, 1 no. top chennel 125×65 mm - 3.20M & 1 no. gaurding angle and X bracing,disc fittingits,11 kv pin with pin insulator, barbed wire,jumpering by PG clamp 2 no Stay set etc.(all material arranged by contractor except steel,insulator,disc insulator GI Pin, Disc Fitting & pole).as per RESPO norms.
Laying of 11 KV XLPE cable
S/C Cable laying in normal soil by digging of trench 1100 mm deep, 750 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. Inter axial spacing between the two cable should be in between 0.25 m to 0.40m. the two cables should be seprated by a partition of single bricks (All the material required for laying will be supplied by the contractor except 11 KV XLPE cable)
Cable laying By dirll method S/C
Cable laying By dirll method Single circuit with MS/ GI Pipe 4" dia
Cable laying by drill method S/C in HDPE Pipe 4" Dia
Hoisting of 11 KV XLPE cable on double pole with GI pipe of size 4" dia 3 M long including its jumpering complete with clamps, nuts and bolts(all material arranged by contractor).
Stringing & Sagging of three phase 11 kv line on ACSR rabbit conductor as per RESPO Norms.
Stringing and sagging of three nos. Earth/GI wire withh caddle guarding of above 11 kv line as per RESPO Norms. Shifting of existing line conductor of 11 Kv/LT lines to maintain proper clearence in between both lines.
Guarding of O/H Line (50 Mtr span)- Fabrication and fixing of gaurding angle on single/double Polesr as per RESSPO Norms including provision of all necessary clamps and hooks.Shifting of existing line conductor of 11 KV/LT lines to maintain proper clearence in between both Lines.(all the material arranged by contractor except steel and GI wire 6 swg)
Ordinary Earthing of pole by M.S. Earthing Rod 20x2500 mm as per Resspo Norms only earting rod provided by deptt
Extra Stay Set - Nozzillling & grouting of stay set .(all the material except stay set will be arranged by the contractor )
Grouting,Plinting and Painting of new erected 11M long ST/PCC poles of single pole support,double pole cable exposures and end type poles of 11 KV lines
Digging of Pit in kachcha/Pakka land in depth upto 1/6 length of Pole, Dragging of STP from near by place/Dump, Erection of Single pole along with stone pad in bottom with proper alignment of line for 11 KV line on 11 M long ST/PCC Pole and refilling with ramming of earth.
Grouting of pole in depth of 1/6 the length of pole in ratio 1:4:8 in cement sand and brick balast as per RESPO norms.
Construction of pole plinth 300mm x 450 mm above ground level in 1:2:4 in cement, coarse sand and stone gritt as per RESPO norms.
High Pressure Testing and fault location of 11 KV cables/line/ as per norms
Tree branches cutting and chopping where required
ARIHANT ELECTRIC COMPANY
M/s CHAUHAN ELECTRICALS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .