| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹79.1 LAccepted-AOC FLAT NO 201 GREEN VALLEY CHS PLOT NO 26 SECTOR 19 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L1 | Accepted-AOC Being 1st Lowest | |
| 2 | L2₹82.1 L+₹1.3 L (1.65%)Rejected-Finance | L2 | Rejected-Finance Being 2nd Lowest | |
| 3 | L3₹83.4 L+₹2.6 L (3.18%)Rejected-Finance 00 KHATA NO 514 4357 PLOT NO 169 3484 KESHARA BHUBANESWAR KHURDA KHORDHA ODISHA 751007 | KHORDHA | ODISHA | 751007 | L3 | Rejected-Finance Being 3rd Lowest | |
| 4 | L4₹84.0 L+₹3.2 L (4.00%)Rejected-Finance 1501 BHAGWATI EMINENCE SAVITRIBAI PHULE MARG BESIDES R R PATIL GARDEN SECTION 13 NERUL E NAVI MUMBAI | RAIGAD | MAHARASHTRA | 400702 | L4 | Rejected-Finance Being 4th Lowest | |
| 5 | L4₹84.6 L+₹3.8 L (4.75%)Rejected-Finance GARDEN AVENUE PLOT NO 242 243 244 RH 4 SECTOR 21 NERUL NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L4 | Rejected-Finance Being 5th Lowest |
Tender Value
₹81.5 L
EMD Value
₹1.5 L
Closing Date
9 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE KARANJA
CWE KARANJA NAVAL STATION KARANJA URAN RAIGAD - 400704
REPAIRS AND REHABILITATION OF STRUCTURAL MEMBERS OF CERTAIN BUILDINGS, WALL TREATMENT OF CHUNABHATTI AREA UNDER AGE BR-I AT NAVAL STATION KARANJA
2023_MES_625978_1
84255-K/E8
Open Tender
Civil Works
Item Rate
180 days
NAVAL STATION KARANJA
Please refer tender documents
8 documents required · 8 mandatory
₹1,000
GE (NW) KARANJA
₹1.5 L
18 Dec 2023
31 Oct 2023
11 Dec 2023
31 Oct 2023
9 Dec 2023
22 Nov 2023
Amount
Notes: (i) Supplying and erecting steel scaffolding upto required height with top platform with support railing at top etc., the scaffolding should be secured properly in position, complete as per site requirement and directions of Engr-in-charge. (ii) Supply and fixing of dust proof netting with all required accessories/ fixing arrangement so as to cover existing installations and arrest the materials generated during repair works in adjoining areas and to prevent damage or nuisance to the existing structure; including proper provision of netting system at shown area before start of work, removal after completion of work, carrying out regular cleaning etc., complete as per site requirement and directions of Engr-in-charge. (iii) Supporting the structural components temporarily during repair and streghthening works using heavy duty flat-headed steel pipes vertically in plumb, braced horizontally and diagonallay at centre with each other using suitable heavy steel tubes, and resting on wooden blocks to support the structure provisionally during repairs and maintaining them in position for required duration complete as per site requirement and directions of Engr-in-charge. (iv) During execution of work column of the bldg shall be repaired in alternate.
(iv) Structural rehabilitation work shall be got executed through one of the specialist firm(s) listed below as approved by GE prior to commencement of work:- (a) Rebuild Technologies Services Pvt Ltd 602, 6th Floor, Tulsee Chamber, Teen Petrol Pump, Thane (W) E (b) Techton Buildcons Pvt Ltd 203, Plot No 6, Milenium Plaza, Sakinaka Telephone Exchange Lane, Off AK Road Andheri E-Mumbai 72 (c ) Sanrachana Structural Strenthening Pvt Ltd 103, 104, Monalisa CHS, Hariniwas Circle, Thane West - 400602 (d) USHTA Infinity Construction Co Pvt Ltd Ushta House, C-17/79 Krishna Industrial Estate, Gorwa, Vadodara - 390016 India (e) Gubbi Civil Engineers 18/26 Dev Prayag CHS, Opp Thanawala garrage, Bhakti Mandir Road, Near Hari Nivas Circle Thane (W), Thane, Maharashtra 400602 (f) M/s KBP Civil Engineering Services, Pune (g) SIKA (h) FOSROC (j) THERMAX Note : All repair/structural/rehabilitation work of RCC structural members shall be carried out by approved firm as mentioned above. Before commencement of work the contractor shall submit Stamp paper of Rs. 500.00 with any specialized agency who is mentioned firm from which he proposes to carry out the work of Sch ‘A’ pertaining to structural repair/rehabilitation with all connected items of Sch ‘A’ alongwith other relevant document. Such specialist agency should have valid authorization letter from the manufacturers.
Removing, chipping and cleaning of existing loose and damaged concrete carefully upto 60mm thickness by low impact high frequency hammer or by manual chipping without damaging the existing concrete including cleaning the surface by air jet and stacking and disposal of unserviceable materials outside the premises, etc., complete all as specified and as directed by Engr-in-charge.
Upto 4th floor
Providing and applying Bi-polar migratory corrosion inhibitor on concrete surface by spraying at 4 sqm/ltr and wiping the surface with moist cloth after few minutes to remove any residual material which has not penetrated, including all necessary surface preparation works, etc., complete all as specified and as directed by Engr-in-charge.
Upto 4th floor
Cleaning all existing reinforcement bars with wire brush/ rotary wire brush to make entire surface of bars free from rust scales, loose material, dirt etc. and applying alkaline rust converting primer in two coats on the existing rebars and allowing it to react with rust and form a corrosion resistant, insoluble protective layer, as per manufacturer’s instructions, etc., complete all as specified and as directed by Engr-in-charge. Note :- Second coat of rust converting perimer shall be applied after 24hours from first coat.
Upto 4th floor
Material and labour for drilling Holes of 12mm dia up to 100 mm deep in structural members at the interval of 300 mm in staggered manner or along the crack line in RCC structural member including cleaning of the holes by air blower and inserting 12mm dia NRV nozzles compatible with epoxy injector and having machined external end to receive outlet of Grouting Gun. Fix the nozzles inside the hole by applying thixotropic epoxy adhesive to ensure complete sealing and allow curing the system for minimum of 8 hrs before grouting; Cut and remove nozzle projections, excess putty, if any, over concrete element by grinding, levelling and finishing the external surface, after completion of the work, etc., complete all as specified and as directed by Engr-in-charge.
Upto 4th floor
Material and labour for providing and injecting two part, low viscous, high strength epoxy resin based moisture insensitive liquid using pressure injector with accessories till nozzle refuses to accept the grout including mixing of grout material components in adequate proportions as per manufacturer's instructions by weight batching and grouting the mixed material into the structural member by grouting gun, maintaining desired pressure in the gun by air compressor and maintaining pressure at exit about 2 to 3 kg/cm2 by monitoring pressure guage at exit. The mixed grout should have following properties:- (i) Mixed Density 1.1 kg/l (at +27°C); Viscosity ~ 250 mPas at +30°C and should comply according to ASTM C 881, Type II and IV, Grade-1, Class E+F (ii) Compressive strength >= 70 N/sqmm (7 days) according to ASTM C 579; Tensile Strength ~ 50 N/sqmm (after 7 days at +30°C cure) (According to ASTM D 638); Tensile Modulus ~ 2000 N/sqmm (after 7 days at +30°C cure) (According to ASTM D 638); (iii) Bond Strength ~ 10.8 N/sqmm (failure in concrete) after 14 days at +30°C cure; Flexural strength ~ 50 N/sqmm according to ISO 178. (iv) Seal the nozzle with thixotropic epoxy adhesive after the refusal of grout material from the nozzle, complete all as specified and as directed by Engr-in-charge.
Upto 4th floor
Material and labour for MS TMT bars for additional reinforcement and shear keys, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in reinforcement complete all as specified and as directed by Engr-in-charge.
For bars above 10mm dia.
For bars of 6mm to 8mm dia.
Anchoring reinforcement bar (shear bar 150 mm length approximate) in existing RCC member in drilled holes and grouting in position with Epoxy resin anchor grout of approved brand, including drilling of holes, cleaning etc. complete all as specified and as directed by Engr-in-charge. Note: Bar shall be measured and paid separately.
Material and labour for providing and applying Zinc rich epoxy anti-corrosive protective coating for reinforcement bars as corrosion protection system in two coats to the entire circumference surface of bars. The product should confirm carbonation resistance of 2 mm and bond strength > 1N/sqmm according to ASTM C 882-78 (Mode of measurement: per sqm of application area of concrete) complete all as specified and as directed by Engr-in-charge. Note : (i) Second coat of anti - corrosive protective coating shall be applied an interval of minimum 06 hours from the first coat. (ii) The coated rebars are to be allowed to cure in air for minimum 48 hours. In case of embeded nars (in repairs) allow fpr 24 hours before application of repair material.
Upto 4th floor
Material and labour for providing, mixing and applying two component epoxy resin concrete bonding coat on prepared RCC surfaces prior to application of any type of repair mortar or microconcrete as per manufacturer's specification including cleaning of surface to remove all dirt, dust or any other impurities, etc. complete. The product should comply with ASTM C 881 Type II Grade 2 Class B+C complete all as specified and as directed by Engr-in-charge.
Upto 4th floor
Material and labour for rebuilding the section of damaged RCC elements to its original size in thickness upto required thickness by providing and casting with ready to use non-shrink, cementitious free flow micro-concrete having compressive strength more than 35N/Sqmm (28 days) according to ASTM C 1107-99 including, drilling holes and fixing shear connectors, mixing the microconcrete with adequate quantity of water, placing, levelling the surface by grinding off cementitious slurry or cementitious joints differences if any and curing complete all as specified and as directed by Engr-in-charge.
Upto 4th floor
Providing watertight formwork of timber planks so as to give a rough finish including centering, shuttering, strutting and propping etc., complete all as specified and as directed by Engr-in-charge.
Upto 4th floor
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed by Engr-in-charge.
Upto 4th floor
Supply and Fix chicken wire mesh of daimond shepe and size of diameter 0.36 - 0.60mm and hole size 15mm x 15mm complete all as specified and as directed by Engr-in-charge.
Providing and applying ready to mix Cement plaster with high quality polymer additives with 4 MPa compressive strength of required thickness over the entire cleaned surfaces including all tools and tackles, etc. complete all as specified and as directed by Engr-in-charge.
For 12mm thickness
Upto 4th floor
For 10mm thickness (Internal)
Upto 4th floor
For 5mm thickness (Ceiling)
Upto 4th floor
Material and labour for new or old surfaces of exterior wall decorating and water proofing treatment to wall surface by wire brushing in order to remove dust, dirt, loose particles, laitance. Thereafter wash the surface with clan water and allow to dry. Fill visible cracks/ joints by chemistic crack seal caulking compound and allow to dry for 24 hours. Apply a primer coat of chemistic prime M Seal (water base primer) and allow to dry for 6 hours. Thereafter apply 02 coats of chemistik PDS-50 (WB high build anti caronatin coating cum waterproofing) & shade by brush at the interval of 08 hours between the coat and allow to dry to match the existing shade including necessary scaffolding for any height, covering etc complete all as specified and as directed by Engr-in-charge.
Material and labour for preparation of newly plastered surfaces and applying two coats of oil emulsion distemper on walls over a coat of chalk whiting primer complete all as specified and as directed by Engr-in-charge.
Material and labour for preparation of new plastered surfaces and applying three coats of white wash on ceilings complete all as specified and as directed by Engr-in-charge.
Dismantling floor hearth or wall (ceramic/mosaic) tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and as directed by Engr-in-charge.
Roughening surfaces of old concrete floors by picking, sweeping clean and washing down with water to remove dust, etc., complete all as specified and as directed by Engr-in-charge.
Material and labour for brushing neat cement slurry with 3 kg of cement per sqm complete all as specified and as directed by Engr-in-charge.
Supply and fix for coloured non skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exc 0.11 sqm but not exc 0.18 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over 20mm thick screed in CM 1:6 complete all as specified and as directed by Engr-in-charge.
Supply and fix for coloured glazed ceramic tiles in vertical surfaces 350x250x7mm/ 450x350x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick backing coat in CM 1:4 on fair faces of brick or concrete surfaces complete all as specified and as directed by Engr-in-charge.
MC Gandhi and Sons
SAI ENTERPRISES
SREE HARITHA ASSOCIATES
M/s S.D Construction Co
Sagar Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .