Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Rejected-Technical | Rejected-Technical EMD not submitted. Item not included in MSME registration |
Tender Value
₹15.6 L
EMD Value
₹31,270
Closing Date
31 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (E)
As Per tender Document
Provision of Capacitors for Saving the penalty on electricity charges at various GSM BTS sites T.E. Bldgs of BA Jammu JandK. Rate Contract.2nd call.
2022_BSNL_116350_1
07(R)/EE(E)/I/BSNL/JMU/2022-23
Open Tender
Electrical Works
Item Rate
30 days
As Per tender Document
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
Account Officer (Cash) office Of GMTD Jammu
₹31,270
Yes
6 Jun 2022
20 May 2022
4 Jun 2022
20 May 2022
31 May 2022
20 May 2022
20 May 2022 - 31 May 2022
90 days
Supplying, fabricating, Installation, testing and commissioning of outdoor type, weather proof box made out of 16 guage mild steel sheet of size 14''x10''x8'' suitable for installation of 3 KVAR rating capacitor complete with cutting, welding, fabricating, painting etc., front open able door, weather proof arrangement & having suitable arrangement for installing capacitor, din bar for installation of TPN MCB, suitable cut-outs for entry of cables etc., fixing / installation arrangement complete with making interconnections with suitable size copper wire as required. a) 3 KVAR, 3 Phase, 50 hz delta connected Capacitor =01 No. b) LED type indicator=01 No. c) 6 TO 32 AMP TP MCB=01 NOS NOTE:- 1. Complete Liasioning with PDD shall be responsibility of the agency for making arrangement for inspection of PDD officials at site and making entry of Capacitors in PDD records for waving off surcharge / penalty, if any, on a/c of capacitors. This is included in the scope of work for the above items. As such rates shall be quoted according. 2. First and final payment shall be made to the agency only after Supply & installation at site, inspection and testing by PDD, entry of capacitor in PDD records and on receiving of first Electricity bill of the site with capacitor Installed status as "Y" (Yes).As such rates shall be quoted according.
Supplying, fabricating, Installation, testing and commissioning of outdoor type, weather proof box made out of 16 guage mild steel sheet of size 18''x12''x8''' suitable for installation of 5 KVAR rating capacitor complete with cutting, welding, fabricating, painting etc., front open able door, weather proof arrangement & having suitable arrangement for installing capacitor, din bar for installation of TPN MCB, suitable cut-outs for entry of cables etc., fixing / installation arrangement complete with making interconnections with suitable size copper wire as required. a) 5 KVAR (3 KVAR + 2 KVAR), 3 Phase, 50 hz delta connected Capacitor=01 set b) LED type indicator=02 Nos. c) 6 TO 32 AMP TP MCB=02 Nos. NOTE:- 1. Complete Liasioning with PDD shall be responsibility of the agency for making arrangement for inspection of PDD officials at site and making entry of Capacitors in PDD records for waving off surcharge / penalty, if any, on a/c of capacitors. This is included in the scope of work for the above items. As such rates shall be quoted according. 2. First and final payment shall be made to the agency only after Supply & installation at site, inspection and testing by PDD, entry of capacitor in PDD records and on receiving of first Electricity bill of the site with capacitor Installed status as "Y" (Yes).As such rates shall be quoted according.
Supplying, fabricating, Installation, testing and commissioning of outdoor type, weather proof box made out of 16 guage mild steel sheet of size 24''x12''x8'' suitable for installation of 10 KVAR rating capacitor complete with cutting, welding, fabricating, painting etc., front open able door, weather proof arrangement & having suitable arrangement for installing capacitor, din bar for installation of TPN MCB, suitable cut-outs for entry of cables etc., fixing / installation arrangement complete with making interconnections with suitable size copper wire as required. a) 10 KVAR (5 KVAR + 3 KVAR + 2 KVAR), 3 Phase, 50 hz delta connected Capacitor = 01 set b) LED type indicator=03 Nos. c) 6 TO 32 AMP TP MCB=03 Nos. NOTE:- 1. Complete Liasioning with PDD shall be responsibility of the agency for making arrangement for inspection of PDD officials at site and making entry of Capacitors in PDD records for waving off surcharge / penalty, if any, on a/c of capacitors. This is included in the scope of work for the above items. As such rates shall be quoted according. 2. First and final payment shall be made to the agency only after Supply & installation at site, inspection and testing by PDD, entry of capacitor in PDD records and on receiving of first Electricity bill of the site with capacitor Installed status as "Y" (Yes).As such rates shall be quoted according.
Supplying and laying of following size PVC insulated PVC round sheathed copper conductor flexible cable of 1.1 KV grade i/c laying as per site requirement,connections etc of capacitors complete as required.
3 Core 2.5 Sqmm
3 Core 4 Sqmm
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .