Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.0 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST AND REASONABLE | |
| 2 | L2₹42.2 L+₹8.2 L (24.2%)Rejected-AOC | L2 | Rejected-AOC NOT BEING L1 | |
| 3 | L3₹46.6 L+₹12.7 L (37.3%)Rejected-AOC A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | L3 | Rejected-AOC NOT BEING L1 |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
19 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE EM RR HOSPITAL
GE EM RR HOSPITAL RAO TULA RAM MARG DELHI CANTT-10
CA No GE/H-46/2021-22 REPAIR/REPLACEMENT OF LT DISTRIBUTION SYSTEM AND ALLIED WORKS AT AHRR UNDER GE E/M RR HOSP AT DELHI CANTT-10
2021_MES_496586_1
GE/H-46/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE EM RR HOSPITAL
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE EM RR HOSPITAL
₹70,000
Yes
16 Feb 2022
22 Dec 2021
21 Jan 2022
22 Dec 2021
19 Jan 2022
5 Jan 2022
60 days
Amount
Excavating in trenches in soft / loose soil, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth and getting out complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engr-in-Charge.
Removal of excavated material not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and directed by Engr-in-Charge.
Material and labour for sand cushioning with layer of sand 8cm thick before laying of cable and 15cm after laying of cable in trenches complete all as specified and directed by Engr-in-Charge.and sand cover to under ground cable complete all as directed.
Supplying laying, brick sub class 'B' common burnt laid in trenches for cable protection complete all as specified and directed by Engr-in-Charge.
M&L for taking down old U/S cable from wall/trench/roof any height and Supply, laying (laying in ducts/trenches/on walls/ fixing on existing cable tray with new saddles & clamps etc as per site requirement), jointing, testing and commissioning with new XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm x 3.5 Core in trench/ on pole/ in duct complete all as specified and directed by Engr-in-Charge. Note:- 1. The cost of AI thimbles / lugs/clamps/fastner and cable gland etc is included in quoted rate and no extra payment will be made for it. 2. Excavation, earth work, sand cushioning, cable cover and Cable joints will be measured and paid separately under respective items of this sch.
All as per srl item No 6 here-in-before but 70 sqmm x 3.5 Core.
All as per srl item No 6 here-in-before but 95 sqmm x 3.5 Core.
All as per srl item No 6 here-in-before but 120 sqmm x 3.5 Core.
All as per srl item No 6 here-in-before but 150 sqmm x 3.5 Core.
All as per srl item No 6 here-in-before but 185 sqmm x 3.5 Core.
All as per srl item No 6 here-in-before but 240 sqmm x 3.5 Core.
All as per srl item No 6 here-in-before but 300 sqmm x 3.5 Core.
All as per srl item No 6 here-in-before but 400 sqmm x 3.5 Core.
S&F in replacement of GI pipe of 80 mm nominal dia light grade with all fittings laid in trenches or under road crossing or fixed to walls/poles with clamps nuts, bolts and washers including painting with two coats of aluminium paint over a coat of red oxide paint complete all as specified and directed by Engr-in-Charge.
All as per srl item No 15 here-in-before but for GI pipe of 50 mm dia size.
Material & Labour for road cutting, including excavation, returning filling in, spreading, leveling well ramming in layers, soling with broken boulders/stones, WBM 7.5 cm thick coarse aggregate received from dismentling the existing road, premix, carpeting 25 mm thick using ready mix patch mate material, rolled and compacted for road patch repair work, complete all as specified and directed by Engr-in-Charge.
Bringing fault detector machine with skilled tradesmen to detecting the fault by inducing the high potential in any sizes of LT cables and marked the place where fault detected and testing after rectifying the fault complete all as specified and directed by Engr-in-Charge. Note: Quoted rate is to be inclusive of necessary excn, RFR etc. and no extra payment will be made on this effect.
Supply only Heat shrinkable LT 1.1 KV straight through joint suitable for aluminium cable of Size 300 Sqmm to 400 Sqmm x 3.5 core complete all as specified and directed by Engr-in-Charge.
All as per srl item No 19 here-in-before but for 185 Sqmm to 240 sqmm x 3.5 core .
All as per srl item No 19 here-in-before but for 70 Sqmm to 150 sqmm x 3.5 core .
All as per srl item No 19 here-in-before but for 25 Sqmm to 50 sqmm x 3.5 core .
Supply and fixing in replacement of MCCB, four pole, 415 volts, adjustable type of capacity 100 Amps, 16 KA, adjustable type thermal- magnetic release, including spreader terminals, phase barriers, thimbles of suitable size etc and making electric connections and taking down old unserviceable MCCB, complete all as specified and directed by Engr-in-Charge.
All as per items No. 23 here-in-before but 125 Amp capacity, 16 KA
All as per items No. 23 here-in-before but 160 Amp, 36 KA capacity
All as per items No. 23 here-in-before but 200 Amp, 36 KA capacity
All as per items No. 23 here-in-before but 250 Amp, 36 KA capacity
All as per items No. 23 here-in-before but 400 Amp, 36 KA capacity
S&F in replacement of MCCB 200 Amps with Overload adjustable and short circuit adjustable , 4 pole, 415 volt, 50Hz, breaking capacity 25 KA, 200 Amp, XT4 MCCB, Cat pt No 1SDA068109R1, Rotary Handle Cat Pt No 1SDA054934R1, Spreaded terminals Cat Pt No 1SYN450210R0001, Separator Cat Pt No 1SYN850210R001 complete all as specified and directed by Engr-in-Charge.
S&F in replacement factory made, sheet metal enclosure frame size suitable for MCCB 250 Amps,4 pole incl all fixing material/accessories such as mounting nuts etc complete all as specified and directed by Engr-in-Charge.
Disconnecting HT supply and taking out LT ACB of any make EDO type and rating 800 Amps to 2500 Amp and servicing by cleaning the fix and moving parts, removing dust particles by using high speed blower applying grease / jelly to moving mechanism and moving parts, tightening nut bolts of all the components of ACB and replacement of all unserviceable spares as required, testing commissioning and putting on the supply on load and testing with VI injecting instrument for full load test/calibration for work efficiently in the tripping circuit complete all as specified and directed by Engr-in-Charge. Note:- (i) Servicing/repairs shall be carried out by authorised service engineer only. (ii) Spares as required for replacement shall be of the same company as of existing make or as recommended by the Engr-in-charge. (iii) Cost of spares shall be measured and paid separately under relevant items as "Supply only".
Supply only in replacement Arc Chutes suitable for LT ACB of any make EDO type and rating 800 Amps to 2500 Amps as per existing make and model complete all as specified and directed by Engr-in-Charge.
Supply only in replacement Jaw Contacts suitable for LT ACB of any make EDO type and rating 800 Amps to 2500 Amps as per existing make and model complete all as specified and directed by Engr-in-Charge.
Supply only in replacement CT's of suitable ratio for LT ACB of any make EDO type and rating 800 Amps to 2500 Amps as per existing make and model complete all as specified and directed by Engr-in-Charge.
Supply only in replacement Upper terminals suitable for LT ACB of any make EDO type and rating 800 Amps to 2500 Amps as per existing make and model complete all as specified and directed by Engr-in-Charge.
Supply only in replacement lower terminals suitable for LT ACB of any make EDO type and rating 800 Amps to 2500 Amps as per existing make and model complete all as specified and directed by Engr-in-Charge.
Supply only in replacement circuit draw out terminals suitable for LT ACB of any make EDO type and rating 800 Amps to 2500 Amps as per existing make and model complete all as specified and directed by Engr-in-Charge.
Supply only in replacement pole unit suitable for LT ACB of any make EDO type and rating 800 Amps to 2500 Amps as per existing make and model complete all as specified and directed by Engr-in-Charge.
Supply only in replacement Motor gear box assembly suitable for LT ACB of any make EDO type and rating 800 Amps to 2500 Amps as per existing make and model complete all as specified and directed by Engr-in-Charge.
Supply only in replacement Shunt trip closing coil suitable for LT ACB of any make EDO type and rating 800 Amps to 2500 Amps as per existing make and model complete all as specified and directed by Engr-in-Charge.
Supply only in replacement manual charging handle suitable for LT ACB of any make EDO type and rating 800 Amps to 2500 Amps as per existing make and model complete all as specified and directed by Engr-in-Charge.
Supply only in replacement UVR under voltage release coil assembly suitable for LT ACB of any make EDO type and rating 800 Amps to 2500 Amps as per existing make and model complete all as specified and directed by Engr-in-Charge.
Supply only in replacement shutter assembly suitable for LT ACB of any make EDO type and rating 800 Amps to 2500 Amps as per existing make and model complete all as specified and directed by Engr-in-Charge.
Supply only in replacement earth fault relay suitable for LT ACB of any make EDO type and rating 800 Amps to 2500 Amps as per existing make and model complete all as specified and directed by Engr-in-Charge.
Supply only in replacement Racking inter lock complete suitable for LT ACB of any make EDO type and rating 800 Amps to 2500 Amps as per existing make and model complete all as specified and directed by Engr-in-Charge.
Supply only in replacement fixed/moving arching contacts suitable for LT ACB of any make EDO type and rating 800 Amps to 2500 Amps as per existing make and model complete all as specified and directed by Engr-in-Charge.
Supply only in replacement lockable trip push button type A suitable for LT ACB of any make EDO type and rating 800 Amps to 2500 Amps as per existing make and model complete all as specified and directed by Engr-in-Charge.
Supply only in replacement auxiliary contact block suitable for LT ACB of any make EDO type and rating 800 Amps to 2500 Amps as per existing make and model complete all as specified and directed by Engr-in-Charge.
S&F in replacement of LED type indicator lamp of Red/Yellow/Blue/Green colour for phase/system ON/OFF indication with and including taking down of unserviceable indicator and making all electric connection in existing panel, complete all as specified and directed by Engr-in-Charge.
Supply & Fixing LED Voltmeter 3 phase accuracy CI 0.5 50 to 520 Volts AC (96 mmx 96 mm) complete all as specified and directed by Engr-in-Charge.
Supply & Fixing LED Ammeter 3 phase accuracy CI 0.5 50 incl with suitable capacity CT's (96 mmx 96 mm) complete all as specified and directed by Engr-in-Charge.
Attending breakdown /inspection of LT ACB of any make EDO type and rating 800 Amps to 2500 Amps as per existing make and model complete all as specified and as directed. by authorised service engineer to check and replace any spares related breakdown complete all as specified and directed by Engr-in-Charge. (i) Maintenance/repair shall be carried out by authorised service engineer. (ii) All Measuring equipments and T&P required shall be arranged by the contractor. (iii) any other activity/ minor items not listed/covered here above and required during /completing the work for smooth functiong of system will have to be arranged by Contractor himself and for this purpose no extra cost will be paid. (iv) Major Spare parts shall be paid separately under relative item as supply only. However fixing charges shall deemed to be included in this item (v) A sum of Rs. 5000/- will be recovered from the contractor for non rectification of breakdown/fault or replacement of any unserviceable spares after 12 hours from lodging of complaint telephonically or verbaly. (vi) Thereafter Rs. 1000/- will be added every day till rectification of fault or replacement of unserviceable spares complete all as specified and directed by Engr-in-Charge.
M&L for painting on old painted surface of LT panels/ busbar chamber by brushing/cleaning stains & grease spots with thinner and sand paper and painting the cleaned surface with synthetic enamel paint (Light gray) Shade No 631 or as approved by the Engr-in-charge to achieve good finish by applying two coats of paint by spray painting machine carefully after disconnection of power supply and covering the meters, indicators relays and switches to prevent from fall of paint drops on the panels including writing, number, letter etc with white paint on newly painted surfaces complete all as specified and directed by Engr-in-Charge.
Disconnecting electrically switch boards/ electric panels/ distribution boards of any size by taking proper electric shut down, opening cables from MCCBs/DBs/main switches/panels, cutting of unserviceable/overheated cable ends/ thimbles etc, M&L for fixing of new aluminium thimbles suitable for LT cable size up to 400 sqmm x 3.5 core as required at site, insulation of all necked wires as per existing colour code, re-fixing/re-assembling as per existing complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement CABLOFIL wire meshed Hot dip Galvanized cable tray 54mm (h) x 200 mm (w) complete with nuts bolts washers (GI) and all accessories for mounting and supporting the cable tray system, along with vertical bends, bends complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement cover Hot dip Galvanized for mounting and covering cables on cable tray width 200 mm along with clips Complete with all mounting and supporting accessories complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement CABLOFIL wire meshed Hot dip Galvanized cable tray 54mm (h) x 300 mm (w) complete with nuts bolts washers (GI) and all accessories for mounting and supporting the cable tray system, along with vertical bends, bends complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement cover Hot dip Galvanized for mounting and covering cables on cable tray width 300 mm along with clips Complete with all mounting and supporting accessories complete all as specified and directed by Engr-in-Charge.
Supply, fabricate, install, testing and commissioning in replacemnt LT control panel outdoor type powder coated, weather proof,dust proof,vermin proof made out of 3.15 mm thick CRCA sheet front and back openable door, angle iron frame and locking arrangement with pad lock, including suitable working space in bus bar chamber, cable box chamber with alley suitable for 3 phase 4 wire system,415V, 50 Hz,AC supply including aluminium bus raisers with PVC sleeves/ tape RYB colours for phases identification, including all bus raiser shall be extend upto cable box chamber fixed on fibre insulation for RYB & neutral to all out going cable, confirming to IP-54 and fixed on raised PCC platform with PCC 1:2:4,type B1 (20mm graded aggregate) raised base with control wiring with comprissing cable gland brass, copper lugs etc. including dismantling the unserviceable panel and compressing the following. Loc- MAP S/S complete all as specified and directed by Engr-in-Charge. (i) 1200 A aluminium bus bar TPN system. (ii) Space and fixing arrangement for installation of existing drawn out type ACB 4 Pole 440 volts AC 50 Hz 800 Amps - 01 Nos (iii) Change over switch ON load Open execution 800 Amps 4 Pole, AC 50 Hz 440 Volt -01 (iv) MCCB 4 Pole 440 volts AC 50 Hz 630 Amps 50 kA, adjustable thermal magnetic release - 01 Nos (v) MCCB 4 Pole 440 volts AC 50 Hz 200 Amps 36 kA, adjustable thermal magnetic release - 01 Nos (vi) MCCB 4 Pole 440 volts AC 50 Hz 160 Amps 36 kA, adjustable thermal magnetic release - 01 Nos (vii) MCCB 4 Pole 440 volts AC 50 Hz 63 Amps 16 kA,adjustable thermal magnetic release - 02 Nos (viii) Street light Digital timer including 4 pole 63/65 Amp power contactor, isolator 4 pole, indicator lamps with switch for bypass arrangment. (ix) Surge protection device 63/65 Amps 15kA -01 Nos (x) Indication lamp RYB for phase indication- 01 Set of three (xi) Intelligent meter with all parameter as specified in Part No- CSM-A-M5-S3 of C&S with suitable capacity of 03 Nos CT's - 01 (xii) MCCB 4 Pole 440 volts AC 50 Hz 100 Amps 36 kA, adjustable thermal magnetic release - 02 Nos (xiii) Angle iron frame 40x 40x 6 mm for support of panel height.
Supply, fabricate, install, testing and commissioning in replacement LT control panel outdoor type powder coated, weather proof,dust proof,vermin proof made out of 3.15 mm thick CRCA sheet front and back openable door, angle iron frame and locking arrangement with pad lock, including suitable working space in bus bar chamber, cable box chamber with alley suitable for 3phase 4 wire system,415V, 50 Hz,AC supply including aluminium bus raisers with PVC sleeves/ tape RYB colours for phases identification,including all bus raiser shall be extend upto cable box chamber fixed on fibre insulation for RYB & neutral to all out going cable, confirming to IP-54 and fixed on raised PCC platform with PCC 1:2:4,type B1 (20mm graded aggregate) raised base with control wiring with comprissing cable gland brass, copper lugs etc. including dismantling the unserviceable panel and compressing the following. Near Gas manifold (i) 400 A aluminium bus bar TPN system. (ii) MCCB 4 Pole 440 volts AC 50 Hz 250 Amps 25 kA, adjustable thermal magnetic release 01 No (iii) MCCB 4 Pole 440 volts AC 50 Hz 63 Amps 16 kA, adjustable thermal magnetic release - 03 Nos (iv) MCCB 4 Pole 440 volts AC 50 Hz 32 Amps 16 kA, adjustable thermal magnetic release- 05 Nos (v) MCB 4 Pole 440 volts AC 50 Hz 32 Amps 10 kA, C curve- 01 No (vi) MCB 4 Pole 440 volts AC 50 Hz 40 Amps 10 kA, C curve- 01 No (vii) Indication lamp RYB for phase indication- 01 Set of three (viii) Intelligent meter with all parameter as specified in Part No- CSM-A-M5-S3 of C&S with suitable capacity of 03 Nos CT's - 01 (ix) Street light timer including power contactor 63 amps capacity complete with internal wiring- 02 set (x) Surge protection device 40 Amps 15kA -02 Nos (xi) MCCB 4 Pole 440 volts AC 50 Hz 100 Amps 36 kA, adjustable thermal magnetic release - 01 Nos (xii) Angle iron frame 40x 40x 6 mm for support of panel height .
Supply, fabricate, install, testing and commissioning in replacement LT control panel indoor type powder coated, weather proof,dust proof,vermin proof made out of 2.00mm thick CRCA sheet front and back openable door, angle iron frame and locking arrangement with pad lock, including suitable working space in bus bar chamber, cable box chamber with alley suitable for 3 phase 4 wire system,415V, 50 Hz,AC supply including aluminium bus raisers with PVC sleeves/ tape RYB colours for phases identification,including all bus raiser shall be extend upto cable box chamber fixed on fibre insulation for RYB & neutral to all out going cable, confirming to IP-54 and fixed on raised PCC platform with PCC 1:2:4,type B1 (20mm graded aggregate) raised base with control wiring with comprissing cable gland brass, copper lugs etc. including dismantling the unserviceable panel and compressing the following.Loc- DG Room P- 94 (Main panel) (i) 630 A aluminium bus bar TPN system. (ii) MCCB 4 Pole 440 volts AC 50 Hz 400 Amps 36 kA, adjustable thermal magnetic release - 01 Nos (iii) Change over switch ON load Open execution 400 Amps 4 Pole, AC 50 Hz 440 Volt -01 (iv) MCCB 4 Pole 440 volts AC 50 Hz 200 Amps 36 kA, adjustable thermal magnetic release - 01 Nos (v) MCCB 4 Pole 440 volts AC 50 Hz 160 Amps 36 kA, adjustable thermal magnetic release - 02 Nos (vi) Indication lamp RYB for phase indication- 01 Set of three (vii) Intelligent meter with all parameter as specified in Part No- CSM-A-M5-S3 of C&S with suitable capacity of 03 Nos CT's - 01 (viii) MCCB 4 Pole 440 volts AC 50 Hz 100 Amps 36 kA, adjustable thermal magnetic release - 01 Nos (ix) Angle iron frame 40x 40x 6 mm for support of panel height as directed by Engr In Charge .
Supply, fabricate, install, testing and commissioning in replacement LT control panel indoor type powder coated, weather proof,dust proof,vermin proof made out of 2.00mm thick CRCA sheet front and back openable door, angle iron frame and locking arrangement with pad lock, including suitable working space in bus bar chamber, cable box chamber with alley suitable for 3 phase 4 wire system,415V, 50 Hz,AC supply including aluminium bus raisers with PVC sleeves/ tape RYB colours for phases identification,including all bus raiser shall be extend upto cable box chamber fixed on fibre insulation for RYB & neutral to all out going cable, confirming to IP-54 and fixed on raised PCC platform with PCC 1:2:4,type B1 (20mm graded aggregate) raised base with control wiring with comprissing cable gland brass, copper lugs etc. including dismantling the unserviceable panel and compressing the following.Loc- DG Room P- 94 (Lift panel) (i) 320 A aluminium bus bar TPN system. (ii) Change over switch ON load Open execution 200 Amps 4 Pole, AC 50 Hz 440 Volt -01 (iii) MCCB 4 Pole 440 volts AC 50 Hz 200 Amps 36 kA, adjustable thermal magnetic release - 01 Nos (iv) MCCB 4 Pole 440 volts AC 50 Hz 100 Amps 36 kA, adjustable thermal magnetic release - 01 Nos (v) MCCB 4 Pole 440 volts AC 50 Hz 63 Amps 16 kA,adjustable thermal magnetic release - 02 Nos (vi) Indication lamp RYB for phase indication- 01 Set of three (vii) Intelligent meter with all parameter as specified in Part No- CSM-A-M5-S3 of C&S with suitable capacity of 03 Nos CT's - 01 (viii) MCCB 4 Pole 440 volts AC 50 Hz 125 Amps 36 kA, adjustable thermal magnetic release - 01 Nos (ix) Angle iron frame 40x 40x 6 mm for support of panel height as directed by Engr In Charge .
S&F in replacemnet of on load changeover switch 100 Amp, 415 V AC, 4 Pole with sheet steel enclosure complete all as specified and directed by Engr-in-Charge.
M & L in replacement for Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground(earth) pit not less than 2.25 meter deep below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanized iron or wire of size 25x4 mm earthing lead by means of bolts, nuts check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Pt-I connected earthing test point/panel complete including PCC earth chamber using PCC(1:3:6) Type C-2 using graded stone aggregate 50mm thick, cast iron frame with CI cover, Funnel with watering pipe, wire mesh, copper lugs, excavation and earth work etc. complete all as specified and directed. Note: i) Rate included for Adequate quantity of charcoal dust, common salt and Testing commissioning including checking of earth continuity and earth result complete all as specified and as directed. ii) Rates for Main earthing lead from earth electrode to test point upto 7.5 metre will deemed to be included in quoted rates. iii) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost complete all as specified and directed by Engr-in-Charge.
S & F in replacement of aluminium busbar chamber outdoor type with 400 Amps, TPN aluminium busbars for safe power distribution with provision of incoming and outgoing cables & incuding fixing accessories complete all as specified and directed by Engr-in-Charge.
S & F in replacement of aluminium busbar chamber outdoor type with 630 Amps, TPN aluminium busbars for safe power distribution with provision of incoming and outgoing cables & incuding fixing accessories complete all as specified and directed by Engr-in-Charge. Note for item No 1 to 68 :- (i) It is not mandatory to hand over the work site/ bldg to the Cotractor in one stretch. (ii) It may be handed over in peace-meal as and when the site/ bldg are vacated or shut down given by the user including Sunday/ Holiday/ Night Hrs. Contractor shall make/ changes the execution plan accordingly. Any claim what so ever on this account shall not be admissible complete all as specified and directed by Engr-in-Charge. (iii) Rate quoted by the Contractor shall be deemed to include on this account.
KISHORE ENTERPRISES
Ridhi engineers and builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .