| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.1 LAccepted-AOC SIDDHARTH ENCLAVE NEAR JINDAL FACTORY RAMNAGAR ROORKEE 247667 | HARIDWAR | UTTARAKHAND | 247667 | ₹11.1 L | L1 | Accepted-AOC L1 |
| 2 | L2₹11.2 LRejected-Finance | ₹11.2 L | L2 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | M/s Bansi Lal L2 | ANANT ENTERPRISES L1 |
|---|---|---|---|---|---|
| 1.00 | Material and labour for concealed sub main wiring (Three run i.e. 1 x phase and 1 x netural and one run for continues as earth wire connected to earth dolly etc., using red, black and green colour wires as colour coding) with 4 Sqmm single core, FRLSH PVC insulated multistrand copper conductor drawn through and including PVC conduit medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal dia as required at site but not less than 25 mm nominal size, with all fittings and all accessories i.e. pipe bend, elbow, pipe hook/PVC clamps etc., for independent circuit from panel/DB to sheet metal enclosure and including cutting of chases in wall, including making good with cement mortar (1:3) and finishes as per existing complete all as specified and as directed.
Note :-Three run of copper wire and one run conduit shall be measured as one RM length for payment but extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate. | 2,051 | RM | 290 ₹5.9 L | 260 ₹5.3 L |
| 2.00 | Supply and fixing (concealed in wall or as directed) single pole and neutral sheet metal enclosure with a two pin and earth (3-pin, 2P+E) plug and socket, designed with IP-54 protection (protection against dust and splashing water), complete with one single pole MCB of capacity 20/25 Amps (C-Curve, 10kA breaking capacity), 240 volts, AC supply complete all as specified and as directed. | 88 | Each | 1,100 ₹96,800 | 1,200 ₹1.1 L |
| 3.00 | Supply and fixing SPN MCB ‘C’ curve, 32 Amps, 240 volts AC supply, with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in existing DB after removing blanking plate complete all as specified and as directed. | 88 | Each | 650 ₹57,200 | 500 ₹44,000 |
| 4.00 | Material and labour for maintenance free chemical earthing complete with copper solid rod 10 feet length, 17.2 mm dia, made of copper-bonded grounding rod (250+ microns) is a high-tensile, low-carbon steel rod molecularly bonded with 99.9% pure copper, complies with Underwriters Laboratories (UL, UL 467) standards, with exothermally jointed copper bus bar of 50 X 6 X 200 mm for connection. The rod and exothermic joint together successfully tested at 25KA fault current by CPRI, filling around the electrode with minimum 50 kg eco-friendly earth enhancing compound (bentonite/graphite based conductive compound) having low resistivity with each earth rod comply to IEC:62561-7, The earth electrode shall be installed by boring a hole of approx 125 mm dia up to a depth of 4.5 mtr below ground level, top edge of earth rod at a depth not less than 1.5 metre below normal ground level or as per manufacturers instruction, electrode connections by using earth continuity copper strip 32x6 mm (upto test point from top of rod, i.e. 7.5m min) by means of brass bolts/nuts/washers and drawn through and including protected by 50mm dia GI light grade protection pipe from earth plate to test point, including excavation and earth work, complete with HDPE/PVC earth pit chamber with FRP cover of suitable size, installation, commissioning and testing complete all as specified and as directed. | 5 | Each Job | 20,000 ₹1 L | 35,000 ₹1.8 L |
| 5.00Notes for BOQ item 4 above :- (a) Installation of earthing shall be carried out by the manufacturer/company’s authorised engineer, from a company approved by GE, at site. The cost of installation, supervision and commissioning shall be deemed to be included in the quoted unit rate. Nothing extra shall be paid on this account. (b) Testing shall be carried out by the authorised representative of the manufacturer/company in the presence of the Engineer-in-Charge. The earth resistance value shall not exceed 1 Ohm. The contractor shall make all necessary arrangements for testing of earthing, including providing required instruments, accessories and labour, as directed by the Engineer-in-Charge. Test result will be recorded in a register and signed by all concern. (c) The contractor shall submit a five-year guarantee certificate from the manufacturer/company after the certified date of completion of the work for maintaining earth result less than 1 ohm. Obtaining and submission of the said guarantee certificate shall be the responsibility of the contractor. Security deposit on account of this guarantee shall be withheld from the contractor’s payments during the guarantee period, i.e., 10% of the quoted rate for a period up to five years. This security deposit shall be refunded to the contractor after expiry of the guarantee period, provided the system has performed satisfactorily. Alternatively, the contractor may submit a separate interest-bearing Term Deposit Receipt (TDR) in favour of GE for the above amount, valid for the entire guarantee period. (d) Additional earth enhancing compound, if required to achieve earth resistance not exceeding 1 Ohm, shall be provided by the contractor and the cost of the same shall be deemed to be included in the quoted unit rate. No extra payment shall be made on this account. (e) Cost of earthwork and necessary PCC work for fixing earthing pit shall deemed to be included in the quoted unit rate. (f) Purchase voucher of earthing will be produced before payment. Payment shall be made only after getting satisfactory result. (g) Test point shall be measured & paid separately under appropriate item of this BOQ. | |||||
| 6.00 | Supply and fixing Earth continuity conductor or main earthing lead 32x6mm copper strip drawn through protection pipe or any other indicated situation for loop earthing etc. complete all as specified and as directed. | 74 | RM | 2,925 ₹2.2 L | 2,900 ₹2.1 L |
| 7.00 | Supply and fixing GI tubing light grade of size 50 mm bore, ISI marked, laid in trench/on floor and fixed along poles/walls for earth strip/cable protection including pipe fittings (elbow, tee, socket etc), pipe fixed with and including MS clamps of suitable size, nut bolts etc as per site requirement complete all as specified and as directed. | 68 | RM | 746 ₹50,728 | 500 ₹34,000 |
| 8.00 | Supply and fixing test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 4 Nos, 8mm dia 25mm long hex head screw, fixed on wall surface including making connections of down earth conductors and earthing strips complete all as specified and as directed. | 5 | Each | 800 ₹4,000 | 800 ₹4,000 |
Tender Value
₹12.1 L
EMD Value
₹24,140
Closing Date
8 Apr 2026, 6:00 pmClosed
GE (AF) BHISIANA
GE (AF) BHISIANA PIN - 151201
PROVN OF CHEMICAL EARTHING AND PROVN OF SUB MAIN WIRING INCLUDING CONNECTED ITEMS AT FEROZEPUR UNDER GE (AF) BHISIANA
2026_MES_756663_1
GE/BHI/T-96/2025-26
Open Tender
Civil Works
90 days
GE (AF) BHISIANA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) BHISIANA
₹24,140
Yes
GE (AF) BHISIANA
14 May 2026
17 Mar 2026
10 Apr 2026
17 Mar 2026
8 Apr 2026
1 Apr 2026
17 Mar 2026 - 31 Mar 2026
24 Mar 2026
Material and labour for concealed sub main wiring (Three run i.e. 1 x phase and 1 x netural and one run for continues as earth wire connected to earth dolly etc., using red, black and green colour wires as colour coding) with 4 Sqmm single core, FRLSH PVC insulated multistrand copper conductor drawn through and including PVC conduit medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal dia as required at site but not less than 25 mm nominal size, with all fittings and all accessories i.e. pipe bend, elbow, pipe hook/PVC clamps etc., for independent circuit from panel/DB to sheet metal enclosure and including cutting of chases in wall, including making good with cement mortar (1:3) and finishes as per existing complete all as specified and as directed. Note :-Three run of copper wire and one run conduit shall be measured as one RM length for payment but extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate.
Supply and fixing (concealed in wall or as directed) single pole and neutral sheet metal enclosure with a two pin and earth (3-pin, 2P+E) plug and socket, designed with IP-54 protection (protection against dust and splashing water), complete with one single pole MCB of capacity 20/25 Amps (C-Curve, 10kA breaking capacity), 240 volts, AC supply complete all as specified and as directed.
Supply and fixing SPN MCB ‘C’ curve, 32 Amps, 240 volts AC supply, with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in existing DB after removing blanking plate complete all as specified and as directed.
Material and labour for maintenance free chemical earthing complete with copper solid rod 10 feet length, 17.2 mm dia, made of copper-bonded grounding rod (250+ microns) is a high-tensile, low-carbon steel rod molecularly bonded with 99.9% pure copper, complies with Underwriters Laboratories (UL, UL 467) standards, with exothermally jointed copper bus bar of 50 X 6 X 200 mm for connection. The rod and exothermic joint together successfully tested at 25KA fault current by CPRI, filling around the electrode with minimum 50 kg eco-friendly earth enhancing compound (bentonite/graphite based conductive compound) having low resistivity with each earth rod comply to IEC:62561-7, The earth electrode shall be installed by boring a hole of approx 125 mm dia up to a depth of 4.5 mtr below ground level, top edge of earth rod at a depth not less than 1.5 metre below normal ground level or as per manufacturers instruction, electrode connections by using earth continuity copper strip 32x6 mm (upto test point from top of rod, i.e. 7.5m min) by means of brass bolts/nuts/washers and drawn through and including protected by 50mm dia GI light grade protection pipe from earth plate to test point, including excavation and earth work, complete with HDPE/PVC earth pit chamber with FRP cover of suitable size, installation, commissioning and testing complete all as specified and as directed.
Supply and fixing Earth continuity conductor or main earthing lead 32x6mm copper strip drawn through protection pipe or any other indicated situation for loop earthing etc. complete all as specified and as directed.
Supply and fixing GI tubing light grade of size 50 mm bore, ISI marked, laid in trench/on floor and fixed along poles/walls for earth strip/cable protection including pipe fittings (elbow, tee, socket etc), pipe fixed with and including MS clamps of suitable size, nut bolts etc as per site requirement complete all as specified and as directed.
Supply and fixing test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 4 Nos, 8mm dia 25mm long hex head screw, fixed on wall surface including making connections of down earth conductors and earthing strips complete all as specified and as directed.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.07 MB
TenderDocT96of2526.pdf
Tender Documents • 0.42 MB
BOQ_847574.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid