| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAccepted-AOC RATNA RAJ BUILDING 1ST FLOOR 262 BIDHAN ROAD OPP TERA HOTEL PO SILIGURI 734001 DIST DARJEELING WB | JALPAIGURI | WEST BENGAL | 734001 | ₹1.8 Cr Quoted ₹1.9 Cr | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹1.9 Cr+₹2,932.17 (0.02%)Rejected-Finance B 22 HQ ADG NEI GUWAHATI BABULAR BAZAAR TINSUKIA 786125 ASSAM | TINSUKIA | ASSAM | 786125 | ₹1.9 Cr+₹2,932.17 (0.02%) | L2 | Rejected-Finance HIGHER THEN L1 BIDDER |
| 3 | L3₹1.9 Cr+₹39,587.17 (0.21%)Rejected-Finance | ₹1.9 Cr+₹39,587.17 (0.21%) | L3 | Rejected-Finance HIGHER THEN L1 BIDDER |
| 4 | L4₹1.9 Cr+₹59,982.17 (0.32%)Rejected-Finance S NO 50 8 MAMTA SOCIETY VADGAONSHERI BEHIND AYYAPPA TEMPLE PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | ₹1.9 Cr+₹59,982.17 (0.32%) | L4 | Rejected-Finance HIGHER THEN L1 BIDDER |
| 5 | L5₹2.0 Cr+₹16.6 L (8.92%)Rejected-Finance | ₹2.0 Cr+₹16.6 L (8.92%) | L5 | Rejected-Finance HIGHER THEN L1 BIDDER |
Tender Value
₹2.3 Cr
EMD Value
₹3.1 L
Closing Date
9 Dec 2022, 6:00 pmClosed
CWE
HQ 136 WORKS ENGINEERS PIN - 914136 C/O 99 APO
CONVERSION FROM OH LINE TO UG CABLE UNDER GE GANGTOK
2022_MES_559810_1
CWE/136-WE/42 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
364 days
Gangtok
Class B, Category b(ii)
8 documents required · 8 mandatory
₹2,000
GE Gangtok
₹3.1 L
11 Feb 2023
26 Oct 2022
10 Dec 2022
26 Oct 2022
9 Dec 2022
26 Nov 2022
26 Oct 2022 - 2 Nov 2022
Amount
Taking down HT /LT Overhead ACSR conductor line complete all as directed.
Dismantling insulators any type, any size complete all as directed.
Dismantling Cross arms complete all as directed.
Dismantling stay assembly complete all as directed.
Dismantling of poles complete all as directed.
Supply, install, testing and commissioning of 11KV, 50Hz, 21 KA/3Sec, 630 Amp, Rupturing current 350 MVA, 4-Way RMU with Metering (Me), 630A Copper bus-bar SF6 insulated, Outdoor Type (IP:54) , Vaccum steel tank of IP-67, One side- Extensible, consisting of 1 nos motor operated Fixed type LBS (R) as IC and 3 nos. Motor operated Fixed type VCB (L) as Outgoing Feeders. Metering (Me) comprises with Bus PT of ratio 11kV/Rt3/110V/Rt3, Cl-1.0, 50VA and common DVM and feeder wise TVM and Battery and Battery charger of 26Ah of 24V DC for motor operations. VCB Feeders with Shunt trip coils of 24V DC. All live parts, bus bars of RMU should be enclosed in tank to avoid multiple inter connections & sealed for life robotically for three sides and one side Motorized welded non magnetic / non ferrite / stainless steel tank Grade 304 of minimum 2.5 mm thick having IP-67 degree of protection filled with SF6 gas to fulfill the requirement as per IEC 60376, 60376 & 603760 B as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. The unit shall have front cable entry for ease of installation. RMU should be complete with all accessories such as Terminal boots, VPIS, cable supports, all front cable terminations, mechanical indications ON/OFF, Manometer as per with IEC standards 62271-200, 60056, 60129, 60265, 60298, 60420, 60529 and 60694. Altitude of installation up to 2000m as per IEC 60120. The unit shall include the following with all necessary standard fitting required at site. RMU should be tested for an internal arc fault of 21kA for 1 sec for tank as per IEC62271-200 and paint shade and thickness should be 70-80 microns, complete all as specified and as directed. The outer enclosure shall cover the full length of the switch gear, to ensure IP-54 protection for full door covering of complete switchgear. RMU should be provided with battery & charger (24V DC). Including CT, PT with HT Smart metering System
The unit shall include the following with all necessary standard fittings as required at site and incorporating the following accessories : (a) 1 No. Incomer - LBS : (i) 630A Load Break Switch module for making of fault current alongwith Earth Switch of full making capacity. (ii) Short time breaking current - 21KA/ 3 sec. Making Capacity - 52.5KA (iii) Internal Arc - 21kA/1 sec for tank (iv) Nominal operating gas pressure - 1.3(minimum) Bar abs. (v) Power frequency withstand voltage - 28KV (vi) Impulse withstand voltage - 75KV (vii) Outdoor Enclosure - IP-54 (viii) Front cover mechanism - IP2X (ix) Cable covers - 3X (x) Gas pressure manometer (with red & green zones) (xi) Cable box for front termination of the cable suitable upto 3 core 95 Sqmm, 11 KV XLPE cable (xii) Operation Counter (xiii) Fault Passage Indicator (Short circuit + Earth Fault) (xiv) Capacitive voltage indication fixed type system (xv) Stored Energy mechanism for Motorized operation (xvi) Ronis Key Interlock (if required) (xvii) Suitable site replaceable Cable bushings (xviii) Arc proof cable covers with self Interlocking mechanism between doors, earth switch, disconnector & VCB (xix) Right angle boots (push on type)
(b) 3 nos. Outgoing - VCB: (i) 630A Vacuum Circuit Breaker module (ii) Short time current - 21KA/ 3 sec (iii) Internal Arc - 21kA/1 sec for tank (iv) Nominal operating gas pressure - 1.3(minimum) Bar abs. (v) Power frequency withstand voltage - 28KV (vi) Impulse withstand voltage - 75KV (vii) Outdoor Enclosure - IP-54 (viii) Front cover mechanism - IP2X (ix) Cable covers - 3X (x) Stored Energy mechanism for Motorized operation (xi) Cable box for front termination of the cable suitable upto 3 core 95 Sqmm, 11 KV XLPE cable (xii) Suitable site replaceable Cable bushings (xiii) Arc proof cable covers with self Interlocking mechanism between doors, earth switch, disconnector & VCB (xiv) Capacitive voltage indication fixed type system (xv) Mechanical Indications for breaker ON, OFF, EARTH, TRIP, Spring Charged-Discharged (xvi) Right angle boots (push on type) (xvii) Protection CT - 40-80/1A, Cl- 5P10, 2.5VA burden
(c) One No. Operation Handle for Motorized Operation (d) One No. Manometer. (h) Safety Interlocks Shall be provided as per relevant IEC/IS Standards and Manufacturers directions. (j) Above switchgear shall confirm to all relevant IEC/IS Standards. (e) Operation and instruction mannual with drawings - 01 Set. (f) All cable bushing should be replaceable type. (g) Module should be accommodated as per manufacture's design. (i) Necessary interlocking arrangement for safety and operations Vacuum Interrupter should be of same make as RMU. Cable box should be arc proof with bolted door and interlocked with respective earthing switches. Doors should be removable for the ease access to terminate cables.
Note :- (i) Rate Quoted by the firm for this item should include the cost of the following:- (i) PCC work/ any civil work for foundation required for errection of VCB and other accessories all as standard norms.
S&F Aerial Bunched Cable 11 KV grade with 3 x 95 Sqmm standed, compact circular aluminium conductor screened with black extruded semi conducting compound, natural coloured XLPE insulated core screened with black extruded semi conducting compound and one layer of copper tape and covered with black extruded PVC (core identification by colour tape marking red, yellow & blue with colour tape placed longitudinally under the copper tape) and one core 70 Sqmm messenger wire shall be standed non compacted circular aluminium alloy conductor with all accessories confirming to IS-14225 : 1995 complete all as directed.
Supply and erecting in true vertical position steel tubular swaged pole, 11 metre long, complete with mild steel base plate 6mm thick of size 300mm x 300mm, B-118 finial taper plug, bolts, nuts, washers and screws, type 410 SP-55 including arrangements for fixing of AB cable (Note:-(a) The unit rates include staying the poles in a truly vertical position till the foundations are properly set.(b) Excavation, foundation concrete, presenative treatment, etc.will be measured separately under the appropriate sections.Painting to steel tubular poles (inside and outside) is however included in the rates of steel tubular poles.(c) The unit rates for poles shall also apply to struts when poles of the same size are used as struts.(d) The Unit Rates for steel tubular poles also include provision of finial and cast iron base plate fixed to poles.(e) The unit rates also include drilling of holes in steel tubular poles and hooks for continuous G.I. earth wire etc. to the required size and number.(f)The pipe incorporated for steel tubular poles shall be from the makes as indicated under Makes/manufacturer of GI Pipes).
S&F cable jointing kit of 11 KV grade for outdoor termination cold shrinkable type suitable for single core XLPE insulated aluminium conductor 50-90 Sqmm aerial bunched cable complete all as specified and directed.
Materials & labour including fixing & testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 sq. mm 2 core complete all as specified & as directed. Note:- (i) Earthwork & Excavation, GI pipe, DWC pipe etc shall be measured and paid separately under relevant items of this schedule.(ii) The unit rate quoted by the bidder shall deemed to be inclusive of the cost of aluminium thimbles/lugs of suitable sizes.
Materials & labour including fixing & testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 2 core complete all as specified & as directed. Note:- (i) Earthwork & Excavation, GI pipe, DWC pipe etc shall be measured and paid separately under relevant items of this schedule.(ii) The unit rate quoted by the bidder shall deemed to be inclusive of the cost of aluminium thimbles/lugs of suitable sizes.
Materials & labour including fixing & testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 2 core complete all as specified & as directed. Note:- (i) Earthwork & Excavation, GI pipe, DWC pipe etc shall be measured and paid separately under relevant items of this schedule.(ii) The unit rate quoted by the bidder shall deemed to be inclusive of the cost of aluminium thimbles/lugs of suitable sizes.
Materials & labour including fixing & testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 4 core complete all as specified & as directed. Note:- (i) Earthwork & Excavation, GI pipe, DWC pipe etc shall be measured and paid separately under relevant items of this schedule.(ii) The unit rate quoted by the bidder shall deemed to be inclusive of the cost of aluminium thimbles/lugs of suitable sizes.
Materials & labour including fixing & testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 4 core complete all as specified & as directed. Note:- (i) Earthwork & Excavation, GI pipe, DWC pipe etc shall be measured and paid separately under relevant items of this schedule.(ii) The unit rate quoted by the bidder shall deemed to be inclusive of the cost of aluminium thimbles,lugs,cable glands of suitable sizes.
Materials & labour including fixing & testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 4 core complete all as specified & as directed. Note:- (i) Earthwork & Excavation, GI pipe, DWC pipe etc shall be measured and paid separately under relevant items of this schedule.(ii) The unit rate quoted by the bidder shall deemed to be inclusive of the cost of aluminium thimbles/lugs of suitable sizes.
Materials & labour including fixing & testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sq. mm 3.5 core complete all as specified & as directed. Note:- (i) Earthwork & Excavation, GI pipe, DWC pipe etc shall be measured and paid separately under relevant items of this schedule.(ii) The unit rate quoted by the bidder shall deemed to be inclusive of the cost of aluminium thimbles/lugs of suitable sizes.
Materials & labour including fixing & testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq. mm 3.5 core complete all as specified & as directed. Note:- (i) Earthwork & Excavation, GI pipe, DWC pipe etc shall be measured and paid separately under relevant items of this schedule.(ii) The unit rate quoted by the bidder shall deemed to be inclusive of the cost of aluminium thimbles/lugs of suitable sizes.
Materials & labour including fixing & testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sq. mm 3.5 core complete all as specified & as directed. Note:- (i) Earthwork & Excavation, GI pipe, DWC pipe etc shall be measured and paid separately under relevant items of this schedule.(ii) The unit rate quoted by the bidder shall deemed to be inclusive of the cost of aluminium thimbles/lugs of suitable sizes.
Materials & labour including fixing & testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 sq. mm 3.5 core complete all as specified & as directed. Note:- (i) Earthwork & Excavation, GI pipe, DWC pipe etc shall be measured and paid separately under relevant items of this schedule.(ii) The unit rate quoted by the bidder shall deemed to be inclusive of the cost of aluminium thimbles/lugs of suitable sizes.
Materials & labour including fixing & testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 120 sq. mm 3.5 core complete all as specified & as directed. Note:- (i) Earthwork & Excavation, GI pipe, DWC pipe etc shall be measured and paid separately under relevant items of this schedule.(ii) The unit rate quoted by the bidder shall deemed to be inclusive of the cost of aluminium thimbles/lugs of suitable sizes.
Materials & labour including fixing & testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 150 sq. mm 3.5 core complete all as specified & as directed. Note:- (i) Earthwork & Excavation, GI pipe, DWC pipe etc shall be measured and paid separately under relevant items of this schedule.(ii) The unit rate quoted by the bidder shall deemed to be inclusive of the cost of aluminium thimbles/lugs of suitable sizes.
Excavating in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for laying cable, pole foundation etc complete all as specified.
All as per item No 26.00 above but depth exceeding 1.5m but not exceeding 3.0m
Returning filling in soft/loose soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed
Removal of surplus excavated (soil) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and as directed.
Supplying and laying of DWC HDPE pipe .lSI marked in trenches or in cable ducts or fixed on walls using clamps along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, fixing etc. of size 40 mm outer dia complete all as specified and as directed .
Supplying and laying of DWC HDPE pipe .lSI marked in trenches or in cable ducts or fixed on walls using clamps along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, fixing etc. of size 50 mm outer dia complete all as specified and as directed.
Supplying and laying of DWC HDPE pipe .lSI marked in trenches or in cable ducts or fixed on walls using clamps along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, fixing etc. of 75 mm outer dia complete all as specified and as directed.
Supply and laying 40 mm bore GI pipe light grade including fittings fixed to pole/laying under road crossing with clamps complete for cable protection all as specified and as directed.
Supply and laying 80 mm bore GI pipe light grade including fittings fixed to pole/laying under road crossing with clamps completefor cable protection all as specified and as directed
Supply and laying 150 mm bore GI pipe light grade including fittings fixed to pole/laying under road crossing with clamps complete for cable protection all as specified and as directed
M & L Plain cement concrete (1:3:6) type C-1 using 20 mm graded stone aggregates as finishing road/concrete surface including finishing to exposed concrete surfaces even and fair complete all as specified and directed.
M&L for plain cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete all as specified and directed.
S & F loop in- loop junction box of internal dimension 155 x 210 x 92 mm made out of polycarbonate and locking arrangement incl 6 Amps MCB - 1 No, 20 Amps rated 4 way connectors for 3 phase and neutral incoming/out going, mounted in the box, fixing on steel tubular poles using MS Steel 25 X 4 mm Pole Mounting bracket for cable juction box including Insulated cable glands for entry of cable of size 10- 16 sqmm RAL 7035 Grey, nuts bolts, washers all as specified and directed.
M & L Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9 metres long) all as specified and as directed.(Note:-(a) The unit rates include staying the poles in a truly vertical position till the foundations are properly set.(b) Excavation, foundation concrete, presenative treatment, etc.will be measured separately under the appropriate sections.Painting to steel tubular poles (inside and outside) is however included in the rates of steel tubular poles.(c) The unit rates for poles shall also apply to struts when poles of the same size are used as struts.(d) The Unit Rates for steel tubular poles also include provision of finial and cast iron base plate fixed to poles.(e) The unit rates also include drilling of holes in steel tubular poles and hooks for continuous G.I. earth wire etc. to the required size and number.(f)The pipe incorporated for steel tubular poles shall be from the makes as indicated under Makes/manufacturer of GI Pipes).
S&F street light fitting on pole for use with LED lamps, 60 watt, 240 volt, 6000K, with high quality lenses and reflector, high grade alluminium pressure die cast housing with toughened glass cover, IP-66 glas of protection , roadway luminaries with high power LED as a light source complete with control gear and accessories provn of connecting wire with multi stranded copper conductor 1.5 sqmm nominal cross sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI 694 mark with valid CML NO in and incl PVC conduit pipe, accessories etc. Connected upto street light junction box incl bracket of GI pipe light grade of dia equal to size of fitting, 1.2 mtr long bend in required shape, MS clamps 40x3.15mm thick duly painted with 2 coats of synthetic enamel paint and as directed .
Supply, install, testing and commissioning of solar LED all in one street light system, comprised of LED street light 24 watt with minimum lumen capacity 125 lum/W, complete with 40W Mono-crystalline solar panel, battery-18 Ah, 12.8V LiFePO4, MPPT solar charger controller capacity 12V 5 Amps, inbuilt BMS technology, material housing aluminium extruded LED CCT-5700K progressive intelligent dimming confirming to LM 79 for LED light IP 65 standard with backup not less 02 days autonomy (24 hours working time) confirming to latest MNRE, Govt of India specification/BIS/IEC standards including galvanised steel pole complete all as specified and as directed. Note:- (a) Installation shall be carried out in the presence of OEM Representative. (b) Excavation and PCC shall be measured and paid separately. (c) Quoted rate shall be deemed to be inclusive of the replacement warranty period.
Supply, install, comissioning and testing of outdoor LT Pillar board CPRI approved factory made LT 415 V AC, 50 HZ, 3 phase, Busbar chamber comprising of 4 Nos tin plated copper stip insulated and PVC sheathed rating 100 Amps with colour conding mounted on DMC insulator, confirming to IEC-61439 and protection class IP-65 weather and vermin proof, made out of not less than 60mmx60mmx6mm angle iron and 3.15mm thick MS CRCA sheet with front hingled opening, rubber lining locking arrangement, painted internally and externally with powder coating (RAL -7032) internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps. Feeder Pillar No-01
Main incoming MCCB FP 40 Amps, 415 Volts, 18 KA - 01 Each
Rotary Handle- 01 Each
Spreader Link -02 Set
MCB SPN 20 Amps 230 Volt 10 KA - 01 Each
MCB SPN 16 Amps - 230 Volt 10 KA - 03 Each
Astronomical Timer Single phase 230 Volt, 16A -01 Each
Digital Ammeter 3 Ph Class-I, Conforming to IEC 62053-21 - 01 Each
Digital Voltmeter 3 Ph Class-I Conforming to IEC 62053-21 - 01 Each
MCB SP 02 Amps - 230 Volt 10 KA - 06 Each, for control wiring,
LED Indicator lamp (Neon) RYB - 01 Each
CT's 100/5 A (Tapewound) - 01 Set - Set of 3
Min Panel size 600 X 600 X 300 (H x W x D)
Note: (i) Flooring and mounting of panel to a newly constructed platform of suitable size shall be measured and paid for seperately (ii) The above quoted rate to include angle iron of suitable size having height above ground level of min 30 cms
Supply, install, comissioning and testing of outdoor LT Pillar board CPRI approved factory made LT 415 V AC, 50 HZ, 3 phase, Busbar chamber comprising of 4 Nos tin plated copper stip insulated and PVC sheathed rating 150 Amps with colour conding mounted on DMC insulator, confirming to IEC-61439 and protection class IP-65 weather and vermin proof, made out of not less than 60mmx60mmx6mm angle iron and 3.15mm thick MS CRCA sheet with front hingled opening, rubber lining locking arrangement, painted internally and externally with powder coating (RAL -7032) internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps. Feeder Pillar No-02
Main incoming MCCB FP 50 Amps, 415 Volts, 18 KA =01 Each
Rotary Handle- 01 Each
Spreader Link -02 Set
MCB TPN 10 Amps 415 Volt 10 KA - 01 Each
MCB SPN 20 Amps 230 Volt 10 KA - 01 Each
MCB SPN 16 Amps - 230 Volt 10 KA - 03 Each
Astronomical Timer Single phase 230 Volt, 16A - 01 Each
Digital Ammeter 3 Ph Class-I, Conforming to IEC 62053-21 - 01 Each
Digital Voltmeter 3 Ph Class-I Conforming to IEC 62053-21 - 01 Each
MCB SP 02 Amps - 230 Volt 10 KA - 06 Each, for control wiring,
LED Indicator lamp (Neon) RYB - 01 Each
CT's 200/5 A (Tapewound) - 01 Set - Set of 3
Min Panel size 600 X 600 X 300 (H x W x D)
Note: (i) Flooring and mounting of panel to a newly constructed platform of suitable size shall be measured and paid for seperately in respective item of schedule (ii) The above quoted rate to include angle iron of suitable size having height above ground level of min 30 cms
Supply, install, comissioning and testing of outdoor LT Pillar board CPRI approved factory made LT 415 V AC, 50 HZ, 3 phase, Busbar chamber comprising of 4 Nos tin plated copper stip insulated and PVC sheathed rating 100 Amps with colour conding mounted on DMC insulator, confirming to IEC-61439 and protection class IP-65 weather and vermin proof, made out of not less than 60mmx60mmx6mm angle iron and 3.15mm thick MS CRCA sheet with front hingled opening, rubber lining locking arrangement, painted internally and externally with powder coating (RAL -7032) internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps. Feeder Pillar No-03
Main incoming MCCB FP 40 Amps, 415 Volts, 18 KA - 01 Each
MCB SPN 20 Amps 230 Volt 10 KA - 01 Each
MCB SPN 16 Amps 230 Volt 10 KA - 06 Each
Astronomical Timer Single phase 230 Volt, 16A - 01 Each
Digital Ammeter 3 Ph Class-I, Conforming to IEC 62053-21 - 01 Each
Digital Voltmeter 3 Ph Class-I Conforming to IEC 62053-21 - 01 Each
MCB SP 02 Amps - 230 Volt 10 KA - 06 Each, for control wiring,
LED Indicator lamp (Neon) RYB - 01 Each
CT's 100/5 A (Tapewound) - 01 Set - Set of 3
Min Panel size 600 X 600 X 300 (H x W x D)
Rotary Handle- 01 Each
Spreader Link -02 Set
Note: (i) Flooring and mounting of panel to a newly constructed platform of suitable size shall be measured and paid for seperately (ii) The above quoted rate to include angle iron of suitable size having height above ground level of min 30 cms
Supply, install, comissioning and testing of outdoor LT Pillar board CPRI approved factory made LT 415 V AC, 50 HZ, 3 phase, Busbar chamber comprising of 4 Nos tin plated copper stip insulated and PVC sheathed rating 300 Amps with colour conding mounted on DMC insulator, confirming to IEC-61439 and protection class IP-65 weather and vermin proof, made out of not less than 60mmx60mmx6mm angle iron and 3.15mm thick MS CRCA sheet with front hingled opening, rubber lining locking arrangement, painted internally and externally with powder coating (RAL -7032) internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps. Feeder Pilar No-04
Main incoming MCCB FP 125 Amps, 415 Volts, 25 KA - 01 Each
MCB SPN 20 Amps 230 Volt 10 KA - 01 Each
MCB SPN 16 Amps 230 Volt 10 KA - 04 Each
MCB SPN 10 Amps 230 Volt 10 KA - 08 Each
Astronomical Timer Single phase 230 Volt, 16A - 01 Each
Digital Ammeter 3 Ph Class-I, Conforming to IEC 62053-21 - 01 Each
Digital Voltmeter 3 Ph Class-I Conforming to IEC 62053-21 - 01 Each , Cat Part No- C&S CSM-A-V3-S1 or equivalent
MCB SP 02 Amps - 230 Volt 10 KA - 06 Each, for control wiring,
LED Indicator lamp (Neon) RYB - 01 Each
CT's 300/5 A (Tapewound) - 01 Set - Set of 3
Min Panel size 600 X 600 X 300 (H x W x D)
Rotary Handle- 01 Each
Spreader Link -02 Set
Note: (i) Flooring and mounting of panel to a newly constructed platform of suitable size shall be measured and paid for seperately (ii) The above quoted rate to include angle iron of suitable size having height above ground level of min 30 cms
Supply, install, comissioning and testing of outdoor LT Pillar board CPRI approved factory made LT 415 V AC, 50 HZ, 3 phase, Busbar chamber comprising of 4 Nos tin plated copper stip insulated and PVC sheathed rating 200 Amps with colour conding mounted on DMC insulator, confirming to IEC-61439 and protection class IP-65 weather and vermin proof, made out of not less than 60mmx60mmx6mm angle iron and 3.15mm thick MS CRCA sheet with front hingled opening, rubber lining locking arrangement, painted internally and externally with powder coating (RAL -7032) internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps. Feeder Pillar No-05
Main incoming MCCB FP 100 Amps, 415 Volts, 25 KA - 01 Each
MCB TPN 20 Amps - 415 Volt 10 KA - 02 Each
MCB SPN 06 Amps - 230 Volt 10 KA - 01 Each
MCB SPN 10 Amps - 230 Volt 10 KA - 03 Each
MCB SPN 16 Amps - 230 Volt 10 KA - 01 Each
MCB SPN 20 Amps - 230 Volt 10 KA - 02 Each
Astronomical Timer Single phase 230 Volt, 16A - 01 Each
Digital Ammeter 3 Ph Class-I, Conforming to IEC 62053-21 - 01 Each
Digital Voltmeter 3 Ph Class-I Conforming to IEC 62053-21 - 01 Each
MCB SP 02 Amps - 230 Volt 10 KA - 06 Each, for control wiring,
LED Indicator lamp (Neon) RYB - 01 Each
CT's 200/5 A (Tapewound) - 01 Set - Set of 3
Min Panel size 600 X 600 X 300 (H x W x D)
Rotary Handle- 01 Each
Spreader Link -02 Set
Note: (i) Flooring and mounting of panel to a newly constructed platform of suitable size shall be measured and paid for seperately (ii) The above quoted rate to include angle iron of suitable size having height above ground level of min 30 cms
Supply, install, comissioning and testing of outdoor LT Pillar board CPRI approved factory made LT 415 V AC, 50 HZ, 3 phase, Busbar chamber comprising of 4 Nos tin plated copper stip insulated and PVC sheathed rating 200 Amps with colour conding mounted on DMC insulator, confirming to IEC-61439 and protection class IP-65 weather and vermin proof, made out of not less than 60mmx60mmx6mm angle iron and 3.15mm thick MS CRCA sheet with front hingled opening, rubber lining locking arrangement, painted internally and externally with powder coating (RAL -7032) internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps. Feeder Pillar No-06
Main incoming MCCB FP 80 Amps, 415 Volts, 18 KA - 01 Each
MCB SPN 10 Amps - 230 Volt 10 KA - 08 Each
MCB SPN 16 Amps - 230 Volt 10 KA - 01 Each
MCB SPN 20 Amps - 230 Volt 10 KA - 01 Each
Astronomical Timer Single phase 230 Volt, 16A - 01 Each
Digital Ammeter 3 Ph Class-I, Conforming to IEC 62053-21 - 01 Each
Digital Voltmeter 3 Ph Class-I Conforming to IEC 62053-21 - 01 Each
MCB SP 02 Amps - 230 Volt 10 KA - 06 Each, for control wiring,
LED Indicator lamp (Neon) RYB - 01 Each
CT's 200/5 A (Tapewound) - 01 Set - Set of 3
Min Panel size 600 X 600 X 300 (H x W x D)
Rotary Handle- 01 Each
Spreader Link -02 Set
Note: (i) Flooring and mounting of panel to a newly constructed platform of suitable size shall be measured and paid for seperately (ii) The above quoted rate to include angle iron of suitable size having height above ground level of min 30 cms
Supply, install, comissioning and testing of outdoor LT Pillar board CPRI approved factory made LT 415 V AC, 50 HZ, 3 phase, Busbar chamber comprising of 4 Nos tin plated copper stip insulated and PVC sheathed rating 200 Amps with colour conding mounted on DMC insulator, confirming to IEC-61439 and protection class IP-65 weather and vermin proof, made out of not less than 60mmx60mmx6mm angle iron and 3.15mm thick MS CRCA sheet with front hingled opening, rubber lining locking arrangement, painted internally and externally with powder coating (RAL -7032) internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps. Feeder Pillar No-07
Main incoming MCCB FP 100 Amps, 415 Volts, 25 KA - 01 Each
MCB TPN 10 Amps - 415 Volt 10 KA - 02 Each
MCB TPN 16 Amps - 415 Volt 10 KA - 04 Each
MCB SPN 16 Amps - 230 Volt 10 KA - 01 Each
Astronomical Timer Single phase 230 Volt, 16A - 01 Each
Digital Ammeter 3 Ph Class-I, Conforming to IEC 62053-21 - 01 Each
Digital Voltmeter 3 Ph Class-I Conforming to IEC 62053-21 - 01 Each
MCB SP 02 Amps - 230 Volt 10 KA - 06 Each, for control wiring,
LED Indicator lamp (Neon) RYB - 01 Each
CT's 200/5 A (Tapewound) - 01 Set - Set of 3
Min Panel size 600 X 600 X 300 (H x W x D)
Rotary Handle- 01 Each
Spreader Link -02 Set
Note: (i) Flooring and mounting of panel to a newly constructed platform of suitable size shall be measured and paid for seperately (ii) The above quoted rate to include angle iron of suitable size having height above ground level of min 30 cms
Supply, install, comissioning and testing of outdoor LT Pillar board CPRI approved factory made LT 415 V AC, 50 HZ, 3 phase, Busbar chamber comprising of 4 Nos tin plated copper stip insulated and PVC sheathed rating 100 Amps with colour conding mounted on DMC insulator, confirming to IEC-61439 and protection class IP-65 weather and vermin proof, made out of not less than 60mmx60mmx6mm angle iron and 3.15mm thick MS CRCA sheet with front hingled opening, rubber lining locking arrangement, painted internally and externally with powder coating (RAL -7032) internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps. Feeder Pillar No-08
Main incoming MCCB FP 40 Amps, 415 Volts, 18 KA - 01 Each
MCB SPN 10 Amps - 230 Volt 10 KA - 06 Each
MCB SPN 16 Amps - 230 Volt 10 KA - 01 Each
Astronomical Timer Single phase 230 Volt, 16A - 01 Each
Digital Ammeter 3 Ph Class-I, Conforming to IEC 62053-21 - 01 Each
Digital Voltmeter 3 Ph Class-I Conforming to IEC 62053-21 - 01 Each
MCB SP 02 Amps - 230 Volt 10 KA - 06 Each, for control wiring,
LED Indicator lamp (Neon) RYB - 01 Each
CT's 100/5 A (Tapewound) - 01 Set - Set of 3
Min Panel size 600 X 600 X 300 (H x W x D)
Rotary Handle- 01 Each , Cat Part No- C&S EHW 1-0T-125
Spreader Link -02 Set , Cat Part No- CSET0044
Note: (i) Flooring and mounting of panel to a newly constructed platform of suitable size shall be measured and paid for seperately (ii) The above quoted rate to include angle iron of suitable size having height above ground level of min 30 cms
Supply, install, comissioning and testing of outdoor LT Pillar board CPRI approved factory made LT 415 V AC, 50 HZ, 3 phase, Busbar chamber comprising of 4 Nos tin plated copper stip insulated and PVC sheathed rating 200 Amps with colour conding mounted on DMC insulator, confirming to IEC-61439 and protection class IP-65 weather and vermin proof, made out of not less than 60mmx60mmx6mm angle iron and 3.15mm thick MS CRCA sheet with front hingled opening, rubber lining locking arrangement, painted internally and externally with powder coating (RAL -7032) internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps. Feeder Pillar No-09
Main incoming MCCB FP 80 Amps, 415 Volts, 18 KA - 01 Each
MCB SPN 10 Amps - 230 Volt 10 KA - 09 Each
MCB SPN 16 Amps - 230 Volt 10 KA - 02 Each
Astronomical Timer Single phase 230 Volt, 16A - 01 Each
Digital Ammeter 3 Ph Class-I, Conforming to IEC 62053-21 - 01 Each
Digital Voltmeter 3 Ph Class-I Conforming to IEC 62053-21 - 01 Each
MCB SP 02 Amps - 230 Volt 10 KA - 06 Each, for control wiring,
LED Indicator lamp (Neon) RYB - 01 Each
CT's 200/5 A (Tapewound) - 01 Set - Set of 3
Min Panel size 600 X 600 X 300 (H x W x D)
Rotary Handle- 01 Each
Spreader Link -02 Set
Note: (i) Flooring and mounting of panel to a newly constructed platform of suitable size shall be measured and paid for seperately (ii) The above quoted rate to include angle iron of suitable size having height above ground level of min 30 cms
Supply, install, comissioning and testing of outdoor LT Pillar board CPRI approved factory made LT 415 V AC, 50 HZ, 3 phase, Busbar chamber comprising of 4 Nos tin plated copper stip insulated and PVC sheathed rating 250 Amps with colour conding mounted on DMC insulator, confirming to IEC-61439 and protection class IP-65 weather and vermin proof, made out of not less than 60mmx60mmx6mm angle iron and 3.15mm thick MS CRCA sheet with front hingled opening, rubber lining locking arrangement, painted internally and externally with powder coating (RAL -7032) internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps. Feeder Pillar No-10
Main incoming MCCB FP 125 Amps, 415 Volts, 25 KA - 01 Each
MCB TPN 32 Amps - 415 Volt 10 KA - 02 Each
MCB TPN 16 Amps - 415 Volt 10 KA - 01 Each
MCB SPN 10 Amps - 230 Volt 10 KA - 01 Each
MCB SPN 16 Amps - 230 Volt 10 KA - 01 Each
MCB SPN 20 Amps - 230 Volt 10 KA - 03 Each
Astronomical Timer Single phase 230 Volt, 16A - 01 Each
Digital Ammeter 3 Ph Class-I, Conforming to IEC 62053-21 - 01 Each
Digital Voltmeter 3 Ph Class-I Conforming to IEC 62053-21 - 01 Each
MCB SP 02 Amps - 230 Volt 10 KA - 06 Each, for control wiring,
LED Indicator lamp (Neon) RYB - 01 Each
CT's 300/5 A (Tapewound) - 01 Set - Set of 3
Min Panel size 600 X 600 X 300 (H x W x D)
Rotary Handle- 01 Each
Spreader Link -02 Set
Note: (i) Flooring and mounting of panel to a newly constructed platform of suitable size shall be measured and paid for seperately (ii) The above quoted rate to include angle iron of suitable size having height above ground level of min 30 cms
Supply, install, comissioning and testing of outdoor LT Pillar board CPRI approved factory made LT 415 V AC, 50 HZ, 3 phase, Busbar chamber comprising of 4 Nos tin plated copper stip insulated and PVC sheathed rating 200 Amps with colour conding mounted on DMC insulator, confirming to IEC-61439 and protection class IP-65 weather and vermin proof, made out of not less than 60mmx60mmx6mm angle iron and 3.15mm thick MS CRCA sheet with front hingled opening, rubber lining locking arrangement, painted internally and externally with powder coating (RAL -7032) internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps. Feeder Pillar No-11
Main incoming MCCB FP 80 Amps, 415 Volts, 18 KA - 01
MCB TPN 16 Amps - 415 Volt 10 KA - 01 Each
MCB TPN 32 Amps - 415 Volt 10 KA - 02 Each
MCB SPN 16 Amps - 230 Volt 10 KA - 01 Each
Astronomical Timer Single phase 230 Volt, 16A - 01 Each
Digital Ammeter 3 Ph Class-I, Conforming to IEC 62053-21 - 01 Each
Digital Voltmeter 3 Ph Class-I Conforming to IEC 62053-21 - 01 Each
MCB SP 02 Amps - 230 Volt 10 KA - 06 Each, for control wiring,
LED Indicator lamp (Neon) RYB - 01 Each
CT's 100/5 A (Tapewound) - 01 Set - Set of 3
Min Panel size 600 X 600 X 300 (H x W x D)
Rotary Handle- 01 Each
Spreader Link -02 Set
Note: (i) Flooring and mounting of panel to a newly constructed platform of suitable size shall be measured and paid for seperately (ii) The above quoted rate to include angle iron of suitable size having height above ground level of min 30 cms
Supply, install, comissioning and testing of outdoor LT Pillar board CPRI approved factory made LT 415 V AC, 50 HZ, 3 phase, Busbar chamber comprising of 4 Nos tin plated copper stip insulated and PVC sheathed rating 400 Amps with colour conding mounted on DMC insulator, confirming to IEC-61439 and protection class IP-65 weather and vermin proof, made out of not less than 60mmx60mmx6mm angle iron and 3.15mm thick MS CRCA sheet with front hingled opening, rubber lining locking arrangement, painted internally and externally with powder coating (RAL -7032) internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps. Feeder Pillar No-12
Main incoming MCCB FP 160 Amps, 415 Volts, 25 KA - 01 Each
MCB TPN 20 Amps - 415 Volt 10 KA - 03 Each
MCB TPN 10 Amps - 415 Volt 10 KA - 03 Each
MCB SPN 16 Amps - 230 Volt 10 KA - 01 Each
Astronomical Timer Single phase 230 Volt, 16A - 01 Each
Digital Ammeter 3 Ph Class-I, Conforming to IEC 62053-21 - 01 Each
Digital Voltmeter 3 Ph Class-I Conforming to IEC 62053-21 - 01 Each
MCB SP 02 Amps - 230 Volt 10 KA - 06 Each, for control wiring,
LED Indicator lamp (Neon) RYB - 01 Each
CT's 400/5 A (Tapewound) - 01 Set - Set of 3
Min Panel size 700 X 750 X 300 (H x W x D)
Rotary Handle- 01 Each
Spreader Link -02 Set
Note: (i) Flooring and mounting of panel to a newly constructed platform of suitable size shall be measured and paid for seperately (ii) The above quoted rate to include angle iron of suitable size having height above ground level of min 30 cms
Supply, install, comissioning and testing of outdoor LT Pillar board CPRI approved factory made LT 415 V AC, 50 HZ, 3 phase, Busbar chamber comprising of 4 Nos tin plated copper stip insulated and PVC sheathed rating 200 Amps with colour conding mounted on DMC insulator, confirming to IEC-61439 and protection class IP-65 weather and vermin proof, made out of not less than 60mmx60mmx6mm angle iron and 3.15mm thick MS CRCA sheet with front hingled opening, rubber lining locking arrangement, painted internally and externally with powder coating (RAL -7032) internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps. Feeder Pillar No-13
Main incoming MCCB FP 63 Amps, 415 Volts, 18 KA - 01 Each
MCB TPN 16 Amps - 415 Volt 10 KA - 02 Each
MCB TPN 10 Amps - 415 Volt 10 KA - 02 Each
MCB SPN 06 Amps - 230 Volt 10 KA - 02 Each
MCB SPN 16 Amps - 230 Volt 10 KA - 02 Each
Astronomical Timer Single phase 230 Volt, 16A - 01 Each
Digital Ammeter 3 Ph Class-I, Conforming to IEC 62053-21 - 01 Each
Digital Voltmeter 3 Ph Class-I Conforming to IEC 62053-21 - 01 Each
MCB SP 02 Amps - 230 Volt 10 KA - 06 Each, for control wiring,
LED Indicator lamp (Neon) RYB - 01 Each
CT's 200/5 A (Tapewound) - 01 Set - Set of 3
Min Panel size 600 X 600 X 300 (H x W x D)
Rotary Handle- 01 Each
Spreader Link -02 Set
Note: (i) Flooring and mounting of panel to a newly constructed platform of suitable size shall be measured and paid for seperately (ii) The above quoted rate to include angle iron of suitable size having height above ground level of min 30 cms
Supply, install, comissioning and testing of outdoor LT Pillar board CPRI approved factory made LT 415 V AC, 50 HZ, 3 phase, Busbar chamber comprising of 4 Nos tin plated copper stip insulated and PVC sheathed rating 150 Amps with colour conding mounted on DMC insulator, confirming to IEC-61439 and protection class IP-65 weather and vermin proof, made out of not less than 60mmx60mmx6mm angle iron and 3.15mm thick MS CRCA sheet with front hingled opening, rubber lining locking arrangement, painted internally and externally with powder coating (RAL -7032) internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps. Feeder Pillar No-14
Main incoming MCCB FP 50 Amps, 415 Volts, 18 KA - 01 Each
MCB TPN 10 Amps - 415 Volt 10 KA - 01 Each
MCB TPN 16 Amps - 415 Volt 10 KA - 02 Each
MCB SPN 16 Amps - 230 Volt 10 KA - 01 Each
Astronomical Timer Single phase 230 Volt, 16A - 01 Each
Digital Ammeter 3 Ph Class-I, Conforming to IEC 62053-21 - 01 Each
Digital Voltmeter 3 Ph Class-I Conforming to IEC 62053-21 - 01 Each
MCB SP 02 Amps - 230 Volt 10 KA - 06 Each, for control wiring,
LED Indicator lamp (Neon) RYB - 01 Each
CT's 200/5 A (Tapewound) - 01 Set - Set of 3
Min Panel size 600 X 600 X 300 (H x W x D)
Rotary Handle- 01 Each
Spreader Link -02 Set
Note: (i) Flooring and mounting of panel to a newly constructed platform of suitable size shall be measured and paid for seperately (ii) The above quoted rate to include angle iron of suitable size having height above ground level of min 30 cms
Supply, install, comissioning and testing of outdoor LT Pillar board CPRI approved factory made LT 415 V AC, 50 HZ, 3 phase, Busbar chamber comprising of 4 Nos tin plated copper stip insulated and PVC sheathed rating 100 Amps with colour conding mounted on DMC insulator, confirming to IEC-61439 and protection class IP-65 weather and vermin proof, made out of not less than 60mmx60mmx6mm angle iron and 3.15mm thick MS CRCA sheet with front hingled opening, rubber lining locking arrangement, painted internally and externally with powder coating (RAL -7032) internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps. Feeder Pillar No-15
Main incoming MCCB FP 32 Amps, 415 Volts, 18 KA - 01 Each
MCB TPN 16 Amps - 415 Volt 10 KA - 01 Each
MCB SPN 06 Amps - 230 Volt 10 KA - 02 Each
MCB SPN 10 Amps - 230 Volt 10 KA - 01 Each
MCB SPN 16 Amps - 230 Volt 10 KA - 01 Each
Astronomical Timer Single phase 230 Volt, 16A - 01 Each
Digital Ammeter 3 Ph Class-I, Conforming to IEC 62053-21 - 01 Each
Digital Voltmeter 3 Ph Class-I Conforming to IEC 62053-21 - 01 Each
MCB SP 02 Amps - 230 Volt 10 KA - 06 Each, for control wiring,
LED Indicator lamp (Neon) RYB - 01 Each
CT's 100/5 A (Tapewound) - 01 Set - Set of 3
Min Panel size 600 X 600 X 300 (H x W x D)
Rotary Handle- 01 Each
Spreader Link -02 Set
Note: (i) Flooring and mounting of panel to a newly constructed platform of suitable size shall be measured and paid for seperately (ii) The above quoted rate to include angle iron of suitable size having height above ground level of min 30 cms
Supply, install, comissioning and testing of outdoor LT Pillar board CPRI approved factory made LT 415 V AC, 50 HZ, 3 phase, Busbar chamber comprising of 4 Nos tin plated copper stip insulated and PVC sheathed rating 200 Amps with colour conding mounted on DMC insulator, confirming to IEC-61439 and protection class IP-65 weather and vermin proof, made out of not less than 60mmx60mmx6mm angle iron and 3.15mm thick MS CRCA sheet with front hingled opening, rubber lining locking arrangement, painted internally and externally with powder coating (RAL -7032) internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps. Feeder Pillar No-16
Main incoming MCCB FP 80 Amps, 415 Volts, 18 KA - 01 Each
MCB TPN 20 Amps - 415 Volt 10 KA - 02 Each
MCB TPN 16 Amps - 415 Volt 10 KA - 02 Each
MCB SPN 16 Amps - 230 Volt 10 KA - 01 Each
Astronomical Timer Single phase 230 Volt, 16A - 01 Each
Digital Ammeter 3 Ph Class-I, Conforming to IEC 62053-21 - 01 Each
Digital Voltmeter 3 Ph Class-I Conforming to IEC 62053-21 - 01 Each
MCB SP 02 Amps - 230 Volt 10 KA - 06 Each, for control wiring,
LED Indicator lamp (Neon) RYB - 01 Each
CT's 100/5 A (Tapewound) - 01 Set - Set of 3
Min Panel size 600 X 600 X 300 (H x W x D)
Rotary Handle- 01 Each
Spreader Link -02 Set
Note: (i) Flooring and mounting of panel to a newly constructed platform of suitable size shall be measured and paid for seperately (ii) The above quoted rate to include angle iron of suitable size having height above ground level of min 30 cms
Supply, install, comissioning and testing of outdoor LT Pillar board CPRI approved factory made LT 415 V AC, 50 HZ, 3 phase, Busbar chamber comprising of 4 Nos tin plated copper stip insulated and PVC sheathed rating 200 Amps with colour conding mounted on DMC insulator, confirming to IEC-61439 and protection class IP-65 weather and vermin proof, made out of not less than 60mmx60mmx6mm angle iron and 3.15mm thick MS CRCA sheet with front hingled opening, rubber lining locking arrangement, painted internally and externally with powder coating (RAL -7032) internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps. Feeder Pillar No-17
Main incoming MCCB FP 80 Amps, 415 Volts,18 KA - 01 Each
MCB SPN 16 Amps - 230 Volt 10 KA - 10 Each
Astronomical Timer Single phase 230 Volt, 16A - 01 Each
Digital Ammeter 3 Ph Class-I, Conforming to IEC 62053-21 - 01 Each
Digital Voltmeter 3 Ph Class-I Conforming to IEC 62053-21 - 01 Each
MCB SP 02 Amps - 230 Volt 10 KA - 06 Each, for control wiring,
LED Indicator lamp (Neon) RYB - 01 Each
CT's 200/5 A (Tapewound) - 01 Set - Set of 3
Min Panel size 600 X 600 X 300 (H x W x D)
Rotary Handle- 01 Each
Spreader Link -02 Set
Note: (i) Flooring and mounting of panel to a newly constructed platform of suitable size shall be measured and paid for seperately (ii) The above quoted rate to include angle iron of suitable size having height above ground level of min 30 cms
Supply, install, comissioning and testing of outdoor LT Pillar board CPRI approved factory made LT 415 V AC, 50 HZ, 3 phase, Busbar chamber comprising of 4 Nos tin plated copper stip insulated and PVC sheathed rating 250 Amps with colour conding mounted on DMC insulator, confirming to IEC-61439 and protection class IP-65 weather and vermin proof, made out of not less than 60mmx60mmx6mm angle iron and 3.15mm thick MS CRCA sheet with front hingled opening, rubber lining locking arrangement, painted internally and externally with powder coating (RAL -7032) internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps. Feeder Pillar No-18
Main incoming MCCB FP 125 Amps, 415 Volts, 25 KA - 01 Each
MCB TPN 20 Amps - 415 Volt 10 KA - 01 Each
MCB SPN 20 Amps - 230 Volt 10 KA - 01 Each
MCB SPN 16 Amps - 230 Volt 10 KA - 08 Each
MCB SPN 10 Amps - 230 Volt 10 KA - 01 Each
Astronomical Timer Single phase 230 Volt, 16A - 01 Each
Digital Ammeter 3 Ph Class-I, Conforming to IEC 62053-21 - 01 Each
Digital Voltmeter 3 Ph Class-I Conforming to IEC 62053-21 - 01 Each
MCB SP 02 Amps - 230 Volt 10 KA - 06 Each, for control wiring,
LED Indicator lamp (Neon) RYB - 01 Each
CT's 300/5 A (Tapewound) - 01 Set - Set of 3
Min Panel size 600 X 600 X 300 (H x W x D)
Rotary Handle- 01 Each
Spreader Link -02 Set
Note: (i) Flooring and mounting of panel to a newly constructed platform of suitable size shall be measured and paid for seperately (ii) The above quoted rate to include angle iron of suitable size having height above ground level of min 30 cms
Supply, install, comissioning and testing of outdoor LT Pillar board CPRI approved factory made LT 415 V AC, 50 HZ, 3 phase, Busbar chamber comprising of 4 Nos tin plated copper stip insulated and PVC sheathed rating 200 Amps with colour conding mounted on DMC insulator, confirming to IEC-61439 and protection class IP-65 weather and vermin proof, made out of not less than 60mmx60mmx6mm angle iron and 3.15mm thick MS CRCA sheet with front hingled opening, rubber lining locking arrangement, painted internally and externally with powder coating (RAL -7032) internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps. Feeder Pillar No-19
Main incoming MCCB FP 80 Amps, 415 Volts, 18 KA - 01 Each
MCB SPN 16 Amps - 230 Volt 10 KA - 07 Each
MCB SPN 10 Amps - 230 Volt 10 KA - 04 Each
Astronomical Timer Single phase 230 Volt, 16A - 01 Each
Digital Ammeter 3 Ph Class-I, Conforming to IEC 62053-21 - 01 Each
Digital Voltmeter 3 Ph Class-I Conforming to IEC 62053-21 - 01 Each
MCB SP 02 Amps - 230 Volt 10 KA - 06 Each, for control wiring,
LED Indicator lamp (Neon) RYB - 01 Each
CT's 200/5 A (Tapewound) - 01 Set - Set of 3
Min Panel size 600 X 600 X 300 (H x W x D)
Rotary Handle- 01 Each
Spreader Link -02 Set
Note: (i) Flooring and mounting of panel to a newly constructed platform of suitable size shall be measured and paid for seperately (ii) The above quoted rate to include angle iron of suitable size having height above ground level of min 30 cms
Supply, install, comissioning and testing of outdoor LT Pillar board CPRI approved factory made LT 415 V AC, 50 HZ, 3 phase, Busbar chamber comprising of 4 Nos tin plated copper stip insulated and PVC sheathed rating 250 Amps with colour conding mounted on DMC insulator, confirming to IEC-61439 and protection class IP-65 weather and vermin proof, made out of not less than 60mmx60mmx6mm angle iron and 3.15mm thick MS CRCA sheet with front hingled opening, rubber lining locking arrangement, painted internally and externally with powder coating (RAL -7032) internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps. Feeder Pillar No-20
Main incoming MCCB FP 125 Amps, 415 Volts, 25 KA - 01 Each
MCB TPN 20 Amps - 415 Volt 10 KA - 01 Each
MCB SPN 16 Amps - 230 Volt 10 KA - 08 Each
MCB SPN 10 Amps - 230 Volt 10 KA - 01 Each
Astronomical Timer Single phase 230 Volt, 16A - 01 Each
Digital Ammeter 3 Ph Class-I, Conforming to IEC 62053-21 - 01 Each
Digital Voltmeter 3 Ph Class-I Conforming to IEC 62053-21 - 01 Each
MCB SP 02 Amps - 230 Volt 10 KA - 06 Each, for control wiring,
LED Indicator lamp (Neon) RYB - 01 Each
CT's 200/5 A (Tapewound) - 01 Set - Set of 3
Min Panel size 600 X 600 X 300 (H x W x D)
Rotary Handle- 01 Each
Spreader Link -02 Set
Note: (i) Flooring and mounting of panel to a newly constructed platform of suitable size shall be measured and paid for seperately (ii) The above quoted rate to include angle iron of suitable size having height above ground level of min 30 cms
Supply, install, comissioning and testing of outdoor LT Pillar board CPRI approved factory made LT 415 V AC, 50 HZ, 3 phase, Busbar chamber comprising of 4 Nos tin plated copper stip insulated and PVC sheathed rating 400 Amps with colour conding mounted on DMC insulator, confirming to IEC-61439 and protection class IP-65 weather and vermin proof, made out of not less than 60mmx60mmx6mm angle iron and 3.15mm thick MS CRCA sheet with front hingled opening, rubber lining locking arrangement, painted internally and externally with powder coating (RAL -7032) internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps. Feeder Pillar No-21
Main incoming MCCB FP 160 Amps, 415 Volts, 25 KA - 01 Each
MCB TPN 20 Amps - 415 Volt 10 KA - 01 Each
MCB TPN 16 Amps - 415 Volt 10 KA - 08 Each
MCB SPN 16 Amps - 230 Volt 10 KA - 01 Each
Astronomical Timer Single phase 230 Volt, 16A - 01 Each
Digital Ammeter 3 Ph Class-I, Conforming to IEC 62053-21 - 01 Each
Digital Voltmeter 3 Ph Class-I Conforming to IEC 62053-21 - 01 Each
MCB SP 02 Amps - 230 Volt 10 KA - 06 Each, for control wiring,
LED Indicator lamp (Neon) RYB - 01 Each
CT's 400/5 A (Tapewound) - 01 Set - Set of 3
Min Panel size 600 X 750 X 300 (H x W x D)
Rotary Handle- 01 Each
Spreader Link -02 Set
Note: (i) Flooring and mounting of panel to a newly constructed platform of suitable size shall be measured and paid for seperately (ii) The above quoted rate to include angle iron of suitable size having height above ground level of min 30 cms
Supply, install, comissioning and testing of outdoor LT Pillar board CPRI approved factory made LT 415 V AC, 50 HZ, 3 phase, Busbar chamber comprising of 4 Nos tin plated copper stip insulated and PVC sheathed rating 200 Amps with colour conding mounted on DMC insulator, confirming to IEC-61439 and protection class IP-65 weather and vermin proof, made out of not less than 60mmx60mmx6mm angle iron and 3.15mm thick MS CRCA sheet with front hingled opening, rubber lining locking arrangement, painted internally and externally with powder coating (RAL -7032) internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps. Feeder Pillar No-22
Main incoming MCCB FP 100 Amps, 415 Volts, 25 KA - 01 Each
MCB SPN 20 Amps - 230 Volt 10 KA - 05 Each
MCB SPN 16 Amps - 230 Volt 10 KA - 01 Each
MCB SPN 10 Amps - 230 Volt 10 KA - 01 Each
Astronomical Timer Single phase 230 Volt, 16A - 01 Each
Digital Ammeter 3 Ph Class-I, Conforming to IEC 62053-21 - 01 Each
Digital Voltmeter 3 Ph Class-I Conforming to IEC 62053-21 - 01 Each
MCB SP 02 Amps - 230 Volt 10 KA - 06 Each, for control wiring,
LED Indicator lamp (Neon) RYB - 01 Each
CT's 200/5 A (Tapewound) - 01 Set - Set of 3
Min Panel size 600 X 600 X 300 (H x W x D)
Rotary Handle- 01 Each
Spreader Link -02 Set
Note: (i) Flooring and mounting of panel to a newly constructed platform of suitable size shall be measured and paid for seperately (ii) The above quoted rate to include angle iron of suitable size having height above ground level of min 30 cms
Supply, install, comissioning and testing of outdoor LT Pillar board CPRI approved factory made LT 415 V AC, 50 HZ, 3 phase, Busbar chamber comprising of 4 Nos tin plated copper stip insulated and PVC sheathed rating 100 Amps with colour conding mounted on DMC insulator, confirming to IEC-61439 and protection class IP-65 weather and vermin proof, made out of not less than 60mmx60mmx6mm angle iron and 3.15mm thick MS CRCA sheet with front hingled opening, rubber lining locking arrangement, painted internally and externally with powder coating (RAL -7032) internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps. Feeder Pillar No-23
Main incoming MCCB FP 40 Amps, 415 Volts, 18 KA - 01 Each
MCB SPN 20 Amps - 230 Volt 10 KA - 01 Each
MCB SPN 16 Amps - 230 Volt 10 KA - 02 Each
MCB SPN 10 Amps - 230 Volt 10 KA - 02 Each
Astronomical Timer Single phase 230 Volt, 16A - 01 Each
Digital Ammeter 3 Ph Class-I, Conforming to IEC 62053-21 - 01 Each
Digital Voltmeter 3 Ph Class-I Conforming to IEC 62053-21 - 01 Each
MCB SP 02 Amps - 230 Volt 10 KA - 06 Each, for control wiring,
LED Indicator lamp (Neon) RYB - 01 Each
CT's 100/5 A (Tapewound) - 01 Set - Set of 3
Min Panel size 600 X 600 X 300 (H x W x D)
Rotary Handle- 01 Each
Spreader Link -02 Set
Note: (i) Flooring and mounting of panel to a newly constructed platform of suitable size shall be measured and paid for seperately (ii) The above quoted rate to include angle iron of suitable size having height above ground level of min 30 cms
Supply, install, comissioning and testing of outdoor LT Pillar board CPRI approved factory made LT 415 V AC, 50 HZ, 3 phase, Busbar chamber comprising of 4 Nos tin plated copper stip insulated and PVC sheathed rating 100 Amps with colour conding mounted on DMC insulator, confirming to IEC-61439 and protection class IP-65 weather and vermin proof, made out of not less than 60mmx60mmx6mm angle iron and 3.15mm thick MS CRCA sheet with front hingled opening, rubber lining locking arrangement, painted internally and externally with powder coating (RAL -7032) internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps. Feeder Pillar No-24
Main incoming MCCB FP 50 Amps, 415 Volts, 18 KA - 01 Each
MCB SPN 20 Amps - 230 Volt 10 KA - 03 Each
MCB SPN 16 Amps - 230 Volt 10 KA - 02 Each
Astronomical Timer Single phase 230 Volt, 16A
Digital Ammeter 3 Ph Class-I, Conforming to IEC 62053-21 - 01 Each
Digital Voltmeter 3 Ph Class-I Conforming to IEC 62053-21 - 01 Each
MCB SP 02 Amps - 230 Volt 10 KA - 06 Each, for control wiring,
LED Indicator lamp (Neon) RYB - 01 Each
CT's 100/5 A (Tapewound) - 01 Set - Set of 3
Min Panel size 600 X 600 X 300 (H x W x D)
Rotary Handle- 01 Each
Spreader Link -02 Set
Note: (i) Flooring and mounting of panel to a newly constructed platform of suitable size shall be measured and paid for seperately (ii) The above quoted rate to include angle iron of suitable size having height above ground level of min 30 cms
Supply, install, comissioning and testing of outdoor LT Pillar board CPRI approved factory made LT 415 V AC, 50 HZ, 3 phase, Busbar chamber comprising of 4 Nos tin plated copper stip insulated and PVC sheathed rating 800 Amps with colour conding mounted on DMC insulator, confirming to IEC-61439 and protection class IP-65 weather and vermin proof, made out of not less than 60mmx60mmx6mm angle iron and 3.15mm thick MS CRCA sheet with front hingled opening, rubber lining locking arrangement, painted internally and externally with powder coating (RAL -7032) internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps. Main panel at MES Shed
Main incoming MCCB FP 400 Amps, 415 Volts, 36 KA - 01 Each
MCCB FP 160 Amps - 415 Volt 25 KA - 02 Each
MCCB FP 63 Amps - 415 Volt 25 KA - 04 Each
Astronomical Timer Single phase 230 Volt, 16A - 01 Each
Digital Ammeter 3 Ph Class-I, Conforming to IEC 62053-21 - 01 Each
Digital Voltmeter 3 Ph Class-I Conforming to IEC 62053-21 - 01 Each
MCB SP 02 Amps - 230 Volt 10 KA - 06 Each, for control wiring,
LED Indicator lamp (Neon) RYB - 01 Each
CT's 800/5 A (Tapewound) - 01 Set - Set of 3
Min Panel size 1000 X 1000 X 400 (H x W x D)
Rotary Handle- 01 Each
Spreader Link -02 Set
Rotary Handle- 02 Each
Spreader Link -04 Set
Rotary Handle- 04 Each
Spreader Link -08 Set
Note: (i) Flooring and mounting of panel to a newly constructed platform of suitable size shall be measured and paid for seperately (ii) The above quoted rate to include angle iron of suitable size having height above ground level of min 30 cms
Supplying, installing, testing and commissioning of 16 M high Mast system with the following spacifications:- (a) Supply installation testing and commission of high mast shaft shall be in Two section hot dip galvanized , inside and outside in single dip, suitable for wind velocity as per IS:875 Part-3. There shall be only one longitudinal seam section and no circumferential weld. it shall also include accessories for high mast including head frame, 2 point suspension system with steel wire rope 6 " dia (7/19 constrution) duble drum winch, galvanized lantem carriage arrangement suitable for up to 9 luminaries symmetrically tighting final & integral power tool for raising and lowering operation of the high mast. (b) Supply of foundation bolts manufactured from special steel alongwith nuts,washers, anchor, plates & templates as recommended by High mast manufacturer (c) Fixing of LED light fitting 1x200 watt complete set-09 Nos (d) Supply of twin dome aviation obstruction lights of type with Neon lamp as recommended by High mast manufacturer . (e) Supply of control panel housing suitable control circuit for automatic switching ON and OFF of the MAST. It shall also have suitable control for operation of power tool. (f) Construction of suitable shallow foundation with RCC 1:1.5:3 using 20 mm stone aggregate concrete for the high mast considering the safe soil bearing capacity at site as 10 T/Sqm at 2 mtr depth with all materail and labour. (g) Erection of the high mast with help of suitable equipment and wiring of luminaires with all wiring materail and labour. (h) Provision of GI electrode 60cm x 60 cm x 6mm earthing for high mast with earthing lead with 4 mm GI wire complete- 02 Nos. (j) Supply, Installation of control panel on suitable foundation including all materail and labour. (k) Testing and commissioning of above high mast system. Note: The drawing of high mast light shall be got approved from GE before execution the work. Luminaires shall be measured and paid separately under relevant item.
Supply and fix of Energy saving,environmental friendly, long life, exclusive innovative die-casting aluminium IP66 LED flood light of 200/210 watt capacity, suitable for highlighting architectural facade and High mast purpose complete all as directed .
Supply and fix Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as directed .
Supply and fix Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as directed .
M & L of earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate electrode not less than 1.5 m below normal ground level, connected to including galvanised iron strip size 32 x 6 mm by means of bolts, nuts, and washers of galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part I connected to earth test point including provision of earth strip protected by 40 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work in any type of strata, PCC pit with RCC cover, CI frame, char coal, salt & funnel etc complete all as specified or indicated including testing on completion all as specified and directed . (Note: Unit Rate to be considered for earth strip to be fixed 7.5m long)
M & L of earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate electrode not less than 1.5 m below normal ground level, connected to including galvanised iron wire of size 4 mm by means of bolts, nuts, and washers of galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part I connected to earth test point including provision of earth strip protected by 15 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work in any type of strata, PCC pit with RCC cover, CI frame, char coal, salt & funnel etc complete all as specified or indicated including testing on completion all as specified and directed . (Note: Unit Rate to be considered for earth strip to be fixed 7.5m long)
S&F 100mm cable route marker with text "LT CABLE" Disc with support of 1.5 feet -25x3mm Long angle Aluminium painting grouted on ground using PCC 1:2:4 type B0 and necessary earth work (15x15x15 cm) all as directed .
Note 1:- (Applicable for all parts/items) : The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and general condition of contracts before entry/quoting the rates. Note 2:- Attention to bidder is hereby invited to upload revised BOQ if published during their bid submission. Uploading of incorrect/ pre-revised BOQ shall be treated as non bonafide and rejected. Note 3:-Products "Make" of BOQ items including manufacturers of LT Pillar board ( CPRI approved) are given in Particular Specification of Tender Documents.Bidders are advised to keep in mind of all products make as per Particular Specification of Tender Documents before quoting the rates .
Garg Brothers
TOTCO
PARAMOUNT ELECTRICALS
M/s KACHO BHUTIA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .