| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.3 LAccepted-AOC BUNGLOW NO 1 RAJPOOT VILLA BARARU ROAD PATKUYI BARARU SAGAR MP 470002 | SAGAR | SAGAR | MADHYA PRADESH | 470002 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹16.6 L+₹33,670 (2.07%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹17.8 L+₹1.5 L (9.41%)Rejected-Finance 28 AVANTIBAI MARKET MAKRONIA SAUGOR MP 470004 | SAUGOR | SAGAR | MP | 470004 | L3 | Rejected-Finance Not lowest bidder |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
10 Oct 2024, 6:00 pmClosed
GARRISON ENGINEER SAUGOR
Military Engineer services Garrison Engineer Saugor MP- 470001
REPAIR/MAINT OF CEILING FANS, EXHAUST FANS, WALL MOUNTED FANS, GEYSERS, SOLAR WATER HEATERS AND CONNECTED WORKS UNDER GE SAUGOR
2024_MES_672587_1
GE/SGR/TOK-26 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Saugor
Class D category b (i) and as per tender documents
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER SAGAR
₹54,000
Yes
7 Dec 2024
6 Sept 2024
12 Oct 2024
6 Sept 2024
10 Oct 2024
27 Sept 2024
7 Sept 2024 - 14 Sept 2024
Amount
Taking down carefully existing ceiling fan of any size/sweep/make on any height from it's position, dismantling the fan including preventive maintenance by servicing, greasing, oiling, cleaning external surfaces porperly and replacement of defective spare parts and refixing the same in position including testing complete all as specified and directed. Note: (i) Minor items i.e. rubber reel, steel pin, nut bolts, washer, fastner & others items as required for smooth function etc is deemed to included in above quoted rate. (ii) Major spare parts like bearing, bush, capacitor, copper wire, canopy & clamp, fan blade etc shall be measured and paid seperatly as supply and fixing in items given here-in-after. (iii) Rewinding required fan shall be dismentled and repair & measured under relevant item given here-in-after. (iv) Testing should be done to repaired fan minimum 24 Hrs continues running in MES store yard before fixing at site complete.
Taking down carefully existing ceiling fan of any size/sweep/make on any height from it's position, dismantling ceiling fan of 1400mm ( size/make) and taking out existing burnt out winding wire of motor and rewinding the same after proper cleaning with super enamelled copper wires as per existing gauge and turn to achieve the desired RPM, cleaning and replacement of bearings, bushes, capacitor etc as required and testing complete on completion for old model ceiling fan having requirement of super enamelled copper winding wire exceeding 500 Gms and not exceeding 1000 Gms for each fan and testing all complete as directed by the Engineer-in-Charge. Note: (i) Minor items i.e. rubber reel, steel pin, nut bolts, washer, fastner & others items as required for smooth function etc is deemed to included in above quoted rate. (ii) Major spare parts like bearing, bush, capacitor, copper wire, canopy & clamp, fan blade etc shall be measured and paid seperatly as supply and fixing in items given here-in-after. (iii) Testing should be done to repaired fan minimum 24 Hrs continues running in MES store yard before fixing at site complete.
Taking down carefully existing ceiling fan of any size/sweep/make on any height from it's position, dismantling ceiling fan of 1200mm ( size/make) and taking out existing burnt out winding wire of motor and rewinding the same after proper cleaning with super enamelled copper wires as per existing gauge and turn to achieve the desired RPM, cleaning and replacement of bearings, bushes, capacitor etc as required and testing complete on completion for old model ceiling fan having requirement of super enamelled copper winding wire exceeding 500 Gms and not exceeding 1000 Gms for each fan and testing all complete as directed by the Engineer-in-Charge. Note: (i) Minor items i.e. rubber reel, steel pin, nut bolts, washer, fastner & others items as required for smooth function etc is deemed to included in above quoted rate. (ii) Major spare parts like bearing, bush, capacitor, copper wire, canopy & clamp, fan blade etc shall be measured and paid seperatly as supply and fixing in items given here-in-after. (iii) Testing should be done to repaired fan minimum 24 Hrs continues running in MES store yard before fixing at site complete.
M&L single coat painting of ceiling fan of any sweep with 1st grade quality premium high gloss enamel paint by spraying, filling cavites with filler including necessary preparation of surface duly demarking fan Nos by black synthetic enamel paint complete all as specified and directed.
Supply and Fixing in replacement Bearing as per existing size and make of original manufacturer of ceiling fan complete all as specified and directed.
Supply and fixing in replacement 2.5 Mfd paper insulated capacitor complete all as specified and directed.
Supply and fixing in replacement 4 Mfd paper insulated capacitor complete all as specified and directed.
Supply and fixing in replacement GM bush as per existing size and make of original manufacturer of ceiling fan complete all as specified and directed.
Supply and fixing in replacement MS clamp (suitable for ceiling fan) as per existing size and make of original manufacturer of ceiling fan complete all as specified and directed.
Supply and fixing in replacement PVC canopy pair as per existing size and make of original manufacturer of ceiling fan complete all as specified and directed.
M&L in repair to fan shaft by filling metal cutting by machine,grinding polishing complete and making good adequately for any ceiling fan complete all as specified and directed.
S&F hanging clamp with nut/bolt and rubber bush suitable for ceiling fan of any make and size complete all as specified and directed.
M&L for down rod of ceiling fan made of GI pipe light grade 15mm dia duly drill and threaded with all fittings and fixed complete to walls/ceiling complete all as specified and directed.
S&F in repairs fan blade set (set of three) made out of aluminium suitable for 1200/1400 mm sweep ceiling fan, as per existing size, gauge and make of original manufacturer of ceiling fan, including balancing of body strecture for free rotation all directed by Engr-in-Charge. Note: Set of three blades shall be measured as one unit.)
Taking down carefully existing exhaust fan/air circulator fan/ wall mounting fan /table fan of any size/sweep/make on any height from it's position, dismantling the fan including preventive maintenance by servicing, greasing, oiling, cleaning external surfaces porperly and replacement of defective spare parts and refixing the same in position including testing complete all as specified and directed. Note: (i) Minor items i.e. nut bolts, washer, fastner & others items as required for smooth function etc is deemed to included in above quoted rate. (ii) Major spare parts like bearing, bush, copper wire etc shall be measured and paid seperatly as supply and fixing in items given here-in-after. (iii) Rewinding required fan shall be dismentled and repair & measured under relevant item given here-in-after. (iv) Testing should be done to repaired fan minimum 24 Hrs continues running in MES store yard before fixing at site complete.
Taking down carefully existing exhaust fan of any size/sweep/make on any height from it's position, dismantling of exhaust fan and taking out existing burnt out winding wire of motor and rewinding the same with super enamelled bare insulated copper winding wires as per existing gauge and turn to achieve desired RPM including cleaning and replacement of defective parts as required for exhaust fan of size 250 mm to 300 mm sweep and testing all complete as directed by the Engineer-in-Charge. Note: (i) Minor items i.e. nut bolts, washer, fastner & others items as required for smooth function etc is deemed to included in above quoted rate. (ii) Major spare parts like bearing, bush, copper wire etc shall be measured and paid seperatly as supply and fixing in items given here-in-after. (iii) Testing should be done to repaired fan minimum 24 Hrs continues running in MES store yard before fixing at site complete.
Taking down carefully existing exhaust fan of any size/sweep/make on any height from it's position, dismantling of exhaust fan and taking out existing burnt out winding wire of motor and rewinding the same with super enamelled bare insulated copper winding wires as per existing gauge and turn to achieve desired RPM including cleaning and replacement of defective parts as required for exhaust fan of size 450 mm sweep and testing all complete all as specified and directed. Note: (i) Minor items i.e. nut bolts, washer, fastner & others items as required for smooth function etc is deemed to included in above quoted rate. (ii) Major spare parts like bearing, bush, copper wire etc shall be measured and paid seperatly as supply and fixing in items given here-in-after. (iii) Testing should be done to repaired fan minimum 24 Hrs continues running in MES store yard before fixing at site complete.
Taking down carefully existing air circulator fan/ wall mounting fan /table fan of any size/sweep/make on any height from it's position, dismantling of air circulator fan/ wall mounting fan /table fan and taking out existing burnt out winding wire of motor and rewinding the same with super enamelled bare insulated copper winding wires as per existing gauge and turn to achieve desired RPM including cleaning and replacement of defective parts as required for air circulator fan/ wall mounting fan /table fan of any size and testing all complete all as specified and directed. Note: (i) Minor items i.e. nut bolts, washer, fastner & others items as required for smooth function etc is deemed to included in above quoted rate. (ii) Major spare parts like bearing, bush, copper wire etc shall be measured and paid seperatly as supply and fixing in items given here-in-after. (iii) Testing should be done to repaired fan minimum 24 Hrs continues running in MES store yard before fixing at site complete.
M&L single coat painting of exhaust fan/air circulator fan/ wall mounting fan /table fan of any size/sweep with 1st grade quality premium high gloss enamel paint by spraying, filling cavites with filler including necessary preparation of surface duly demarking fan Nos by black synthetic enamel paint complete all as specified and directed.
Supply and fixing in replacement Ball bearing as per existing size and make of original manufacturer of exhaust fan of 250 mm sweep complete all as specified and directed.
Supply and fixing in replacement Ball bearing as per existing size and make of original manufacturer of exhaust fan of 300 mm sweep complete all as specified and directed.
Supply and fixing in replacement Ball bearing as per existing size and make of original manufacturer of exhaust fan of 450 mm sweep complete all as specified and directed.
Supply and fixing in replacement GM bush as per existing size and make of original manufacturer of Table/cabin fan complete all as specified and directed.
S&F in repair fan blade assembly with necessary MS screws & washers , as per existing size, gauge and make of original manufacturer of exhaust fans/Air circular fan/Wall mount Fan /padestel fan of any descriptions . Note: Set of three blades shall be measured as one unit.)
S & F in replacement PVC flexible 3 core round copper conductor of size 2.5 sqmm from including connection complete all as specified and directed.
S & F in replacement PVC flexible 3 core cable with copper conductor of size 0.75 sqmm from ceiling rose to fan including connection complete all as specified and directed.
M & L Writing Nos or figures (Block, Roman, Italic or Indian) such as "MES No …." with synthetic enamel paint (1st grade quality) of tint black/white complete all as specified and directed.
Taking down carefully storage type water heater (Geyser) any make and capacity from clamps/ bolts including disconnecting water and electric connection and refixing the same and connecting up after cleaning of geyser and repair in E/M yard or site bringing out inner tank , geyser apparatus (Flange), thermostat, indicator lamp and reassembling complete after carrying out repair and replacement of wornout parts complete. Note :(i) Petty stores like insulation tape, screws, small piece of cable & others items as required for smooth function etc is deemed to included in above quoted rate. (ii) Major spare parts like worn out spares/repair of leakage of inner tank, thermostate, heating elemant, Geyser flange assembly, Indicating lamp, Fusible plug, Glass wool, safety valve and fastner etc shall be measured and paid seperatly as supply and fixing in items given here-in-after. (iii) Testing should be done to repaired water heater minimum 24 Hrs continues running in MES store yard before fixing at site complete. (iv) Defect developed while taking out the geysers, such as leaking of joints, damaging of thread of pipe/geyser and other GI fittings such as elbow, nipple, union, socket, etc shall be rectified/replaced by the contractor at his own cost.
Supply and fixing in replacement of geyser inner tank made out of stainless steel sheet, minimum weight 1.20 kg suitable for 25 liter capacity geyser, including ‘O’ ring, coupling set, necessary drilling work, nuts, bolts, washers, etc complete suitable for existing geysers .
Supply and fixing in replacement of geyser inner tank made out of stainless steel sheet, minimum weight 1.70 kg suitable for 50 liter capacity geyser, including ‘O’ ring, coupling set, necessary drilling work, nuts, bolts, washers, etc complete suitable for existing geysers .
Supply and fixing in replacement Geyser flange assembly (existing/type) copper alloy cromium plated suitable for 25/50 Ltr capacity including rubber gasket, clamp & nuts/bolts etc complete.
Supply and fixing in replacement Heating element 1.5 KW 230 Volts as per existing make of original manufacturer of Geysers suitable for 25/50 Ltr capacity as per site requirement brass metal, CP complete all as specified and directed.
Supply and fixing in replacement Heating element 2 KW 230 Volts as per existing make of original manufacturer of Geysers suitable for 25/50 Ltr capacity as per site requirement brass metal, CP complete all as specified and directed.
Supply and fixing in replacement Heating element 3/4 KW 230 Volts as per existing make of original manufacturer of Geysers suitable for 25/50 Ltr capacity as per site requirement brass metal, CP complete all as specified and directed.
Supply and fixing in replacement Thermostat as per existing make of original manufacturer of Geysers suitable for 25/50 Ltr capacity complete all as specified and directed.
Supply and fixing in replacement Indicating lamp 230 V as per existing make of original manufacturer of Geysers suitable for 25/50 Ltr capacity complete all as specified and directed.
Supply and fixing in replacement Fusible plug as per existing make of original manufacturer of Geysers suitable for 25/50 Ltr capacity complete all as specified and directed.
Supply and fixing multi functional safety valve 15 mm , used in geysers as per existing make of original manufacturer of Geysers suitable for 25/50 Ltr capacity complete all as specified and directed.
M&L grouting of fastener of suitable size 15 mm dia, 150 mm long by drilling wall and making good to the disturbed surface and matching with existing surface complete all as specified and directed.
M&L Geyser base plate as per sample complete all as specified and directed.
Supply and fixing Glass wool in 25/50 liter capacity geyser by taking out inner & outer tank and reassembling complete all as specified and directed.
M&L for removing old paint and preparation of surface, filling cavites with filler and painting of Geyser with two coat of 1st grade quality premium high gloss enamel paint & demarking MES No for 25 ltr capacity geyser of any make and type by black synthetic enamel paint after painting complete all as specified and directed.
M&L for removing old paint and preparation of surface, filling cavites with filler and painting of Geyser with two coat of 1st grade quality premium high gloss enamel paint & demarking MES No for 50 ltr capacity geyser of any make and type by black synthetic enamel paint after painting complete all as specified and directed.
Supply and fixing Bib cock long body with flanged brass metal cromium plated size 15 mm suitable for hot water complete all as specified and directed.
S&F 15 mm bore stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or unions and fixed complete all as specified and directed.
S&F GI tubing med grade 15 mm bore with all fitting and fixed complete to walls /ceiling, including taking down of old GI Tubing with all fittings complete all as specified and directed.
Supply and fixing in replacement GI union socket 15 mm bore, ISI marked complete all as specified and directed.
Supply and fixing of GI Tee 15 mm bore, ISI marked complete all as specified and directed.
Supply and fixing of GI Elbow 15 mm bore, ISI marked complete all as specified and directed.
Supply and fixing of GI Socket 15 mm bore, ISI marked complete all as specified and directed.
Supply and fixing of GI Hexa nipple 15 mm bore, ISI marked complete all as specified and directed.
Supply and fixing in replacement PVC connection cold water grade 18” long 15 mm dia with two Nos coupling nut of brass, heavy duty, complete all as specified and directed.
Supply and fixing in replacement PVC connection cold water grade 24” long 15 mm dia with two Nos coupling nut of brass, heavy duty, complete all as specified and directed.
Supply and fixing in replacement PVC connection wire woven hot water grade 18” long 15 mm dia with two Nos coupling nut of brass, heavy duty, complete all as specified and directed.
Supply and fixing in replacement PVC connection wire woven hot water grade 24” long 15 mm dia with two Nos coupling nut of brass, heavy duty, complete all as specified and directed.
Supply and fix exhaust fan made of study Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz,RPM 1200, Copper winding of sweep 300MM complete all as specified and directed. Note:- Old unserviceable exhaust fan shall be deposited to AGE E/M store yard.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz,RPM 1200, Copper winding of sweep 250MM complete all as specified and directed. Note:- Old unserviceable exhaust fan shall be deposited to AGE E/M store yard.
Supply and fix exhaust fan, Metal body AC single Phase. 230V of size 300 mm sweep with, blades, and frame and louvers complete all as specified and directed. Note:- Old unserviceable exhaust fan shall be deposited to AGE E/M store yard.
Supply and fix exhaust fan, Metal body AC single Phase. 230V of size 450mm sweep heavy duty with, blades, and frame and louvers complete all as specified and directed. Note:- Old unserviceable exhaust fan shall be deposited to AGE E/M store yard.
Supply & fix Wall mounted fans 230 volts single phase oscillating 400 mm sweep suitable for wall mounting complete all as specified and directed. Note:- Old unserviceable Wall mounted fan shall be deposited to AGE E/M store yard.
S&F in repairs including testing of AC three phase static energy meter of accuracy class 1.0, 3X240V, 50Hz, with backlit LCD display of rating 10-60A. (measures & display KWH, KVAH, V, I, KW, PF, Hz, last month history of KWh & MD in KW) with special features like TOD, tamper logging, optical communication port & display in absence of power with transferent hinge type box complete all as specified and directed. Note:- Old unserviceable energy meter shall be deposited to AGE E/M store yard.
S&F in repairs ,testing of single phase static energy meter of accuracy class 1.0 , 240 volts, 50 Hz with Backlit LCD display rating 05 - 30 A & with push button (measure & display KWH,kVAh, V, I, PF,kW,kVA,Last month history of kWh&MD in kW) with special features like TOD, tamper logging, optical communication port & disolay in absence of power with transparent hinge type box ,DLMS compliance complete all as specified and directed. Note:- Old unserviceable energy meter shall be deposited to AGE E/M store yard.
Repair /services/ checking of solar water heater of any capacity including descaling and arresting any type of leakage complete all as specified and directed.
M& L for screwing existing steel tubing for altration or additions or lengthening screw on pipe to form connectors of any size GI tubing all as specified and directed.
M&L pvc pipe medium grade 25mm/40mm complete all as specified and directed.
Supply and fixing in replacement of solar water heater water tank ( 200Ltr) as per existing make and size of original manufacturer of solar water heater complete all as specified and directed.
S & F in replacement of Special grade Borocilicate glass tube of size 58mm outer dia and length 1800/2100mm as per existing make of original manufacturer of solar water heater for capacity 100 LPD and 200 LPD complete all as specified and directed.
Supply and fixing in replacement of solar collector plate with toughend glass of size 1050mmx1150mmx2160mm as per existing make of original manufacturer of solar water heater for capacity 100 LPD complete all as specified and directed.
Supply and fixing in replacement of solar collector plate with toughend glass of size 1050mmx2030mmx2160mm as per existing make of original manufacturer of solar water heater for capacity 200 LPD and 300 LPD complete all as specified and directed.
Mohan singh (BID ID -3127263)
SHRI RAM ELECTRICALS ENTERPRISES (BID ID -3126622)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .