Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical 4 195 38 PARAMESHWARA NILAYA MARAKADA KUNJATHBAIL DAKSHINA KANNADA KARNATAKA 575014 UDYAM KR 11 0021217 | DAKSHINA KANNADA | KARNATAKA | 575014 | Admitted-Fee/PreQual/Technical |
Tender Value
₹17.1 Cr
EMD Value
₹11.8 L
Closing Date
2 Mar 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Engineer (Navy), Visakhapatnam
Chief Engineer (Navy), Visakhapatnam
AUGMENTATION OF CHILDREN SCHOOL AT INS RAJALI ARAKKONAM
2025_MES_743713_1
88757
Open Tender
Civil Works
Lump-sum
730 days
ARAKKONAM
As per NIT
12 documents required · 12 mandatory
₹3,000
Yes
Garrison Engineer (M) NAS Arakkonam
₹11.8 L
Yes
23 Jan 2026
9 Dec 2025
9 Mar 2026
9 Dec 2025
2 Mar 2026
16 Feb 2026
PHASE-I:
SCHEDULE 'A' PART-I to SCHEDULE 'A' PART-XV Note: Schedule 'A' Part-I to Part-XV are prepriced by MES. Bidders shall insert their lump sum amount in green coloured field under Column 6 only.
Lump Sum price worked out by the contractor for (BUILDINGS & STRUCTURES), as listed in SCHEDULE 'A' PART-I
Lump Sum price worked out by the contractor for 'Site Clearance/Area Development/Earth Work/Excavation', as listed in Schedule 'A' Part-II
Lump Sum price worked out by the contractor for 'Internal Water Supply', as listed in Schedule 'A' Part-III
Lump Sum price worked out by the contractor for 'Internal Electrification', as listed in Schedule 'A' Part-IV
Lump Sum price worked out by the contractor for 'External Water Supply', as listed in Schedule 'A' Part-V
Lumpsum price worked out by the contractor for 'External Electrification', as listed in Schedule 'A' Part-VI
Lump Sum price worked out by the contractor for 'Area Drainage', as listed in Schedule 'A' Part-VII
Lump Sum price worked out by the contractor for 'Sewage Disposal', as listed in Schedule 'A' Part-VIII
Lump Sum price worked out by the contractor for 'Road/Path/Culvert', as listed in Schedule 'A' Part-IX
Lump Sum price worked out by the contractor for 'AIR CONDITIONING', as listed in Schedule 'A' Part-X
Lump Sum price worked out by the contractor for 'LIGHTNING PROTECTION', as listed in Schedule 'A' Part-XI
RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RR Masonary wall RCC M-30 Design Mix in Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete for 150 Users complete all as specified and as directed.
Lump Sum price worked out by the contractor for 'WATER COOLER', as listed in Schedule 'A' Part-XIII
Lump Sum price worked out by the contractor for 'Rain Water Harvesting', as listed in Schedule 'A' Part-XIV
Lump Sum price worked out by the contractor for 'FIRE FIGHTING', as listed in Schedule 'A' Part-XV
Lump Sum price worked out by the contractor for 'DEMOLITION & DISMANTLING', as listed in Schedule 'A' Part-XV
SCHEDULE 'A' PART-XIV: (MISCELLANEOUS ITEMS):
UPGRADATION & ADDITIONS/ALTERATIONS CIVIL WORKS:
INTERNAL WATER SUPPLY:
S&F angle stop valve 15mm dia., fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure pipes complete all as specified and as directed.
S&F health faucet 15mm dia., ABS rubbit cleaning system, with 1.25m long PVC flexible tube and ABS wall hook complete all as specified and as directed.
S&F bib taps 15mm dia., long body, cast copper alloy chromium planted fancy type with butterfly handle, screwed down for pipes complete all as specified and as directed.
INTERNAL ELECTRIFICATION:
Material and labour for Earthing complete with using galvanised steel earth plate electrode of size 600mm x 600mm x 6 mm thick buried directly underground vertically (earth pit not less than 2.25m deep below normal ground level) , with top edge of the plate at a depth not less than 1.5m below ground level connected with and incl galvanised iron strip 32 x 6 mm as earthing lead including 40 mm dia GI pipe light grade by means of nuts bolts, washers and necessary earth work in any type of soil PCC (1:3:6) type C1 chamber and RCC(1:2:4) type B-1cover with handle and watering pipe 20 mm dia GI medium grade with funnel complete with mesh , refiling with black cotton soil, alternate 5 layers of charcoal (250 Kg) & salt crystal (200Kg )and top two inches layers with Back filling compound (100 Kg), all as specified. Note:(i) Quoted rate deemend to include necessary earth work PCC chamber, 50mm thick RCC cover, reinforced with 8mm dia CTD bars at 100mm C/C on both directions, removal of surplus soil , site clearance etc. (ii) GI earth strip , GI tubing light grade upto 7.5m deemed to be included the rate quoted by the contractor.(iii) Beyond 7.5 M the GI earth strip & GI pipe light grade 40 mm dia shall be measured and paid separetely under the respective item of the schedule (iv) Quotated rate include testing after completion from test point and the desired earth resistance shall be not more than 5 ohm .If the desired result is not obtained the earthing will be re done by the contractor at no extra cost. (For Transformer -4, LBS -4, LT Panel - 2, Lighting protection - 6)
Material and labour for Earthing complete with using galvanised steel earth plate electrode of size 600mm x 600mm x 6 mm thick buried directly underground vertically (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate at a depth not less than 1.5m below ground level connected with and incl galvanised GI wire 4mm dia including 25 mm dia GI pipe light grade by means of nuts bolts, washers and necessary earth work in any type of soil PCC (1:3:6) type C1 chamber and RCC(1:2:4) type B-1cover with handle and watering pipe 20 mm dia medium grade with funnel complete with mesh , refiling with black cotton soil, alternate 5 layers of charcoal (250 Kg) & salt crystal (200Kg )and top two inches layers with Back filling compound (100 Kg), all as specified. Note:(i) Quoted rate deemend to include necessary earth work PCC chamber, 50mm thick RCC cover, reinforced with 8mm dia CTD bars at 100mm C/C on both directions, reinforcement removal of surplus soil , site clearance etc. (ii) GI earth strip , GI tubing light grade upto 7.5m deemed to be included the rate quoted by the contractor.(iii) Beyond 7.5 M the GI earth strip & GI pipe light grade 15 mm dia shall be measured and paid separetely under the respective item of the schedule (iv) Quotated rate include testing after completion from test point and the desired earth resistance shall be not more than 5 ohm .If the desired result is not obtained the earthing will be re done by the contractor at no extra cost. (For Street Light)
M&L sub main wiring concealed type with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit medium grade 20mm dia. with accessories complete with two runs of 2.5 Sq.mm. cable and one run of 2.5 Sq.mm. earth wire complete with colour coding and making good the disturbed area complete all as specified and as directed.
Material and labour for Earthing complete with using galvanised steel earth plate electrode of size 600mm x 600mm x 6 mm thick buried directly underground vertically (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate at a depth not less than 1.5m below ground level connected with and incl galvanised iron strip 32 x 6 mm including 40 mm dia GI pipe light grade by means of nuts bolts, washers and necessary earth work in any type of soil PCC (1:3:6) type C1 chamber and RCC(1:2:4)type B-1cover and watering pipe 20 mm dia medium grade with funnel complete with mesh , refiling with black cotton soil all as specified. Note:(i) Quoted rate deemend to include necessary earth work PCC chamber, 50mm thick RCC cover, reinforced with 8mm dia CTD bars at 100mm C/C on both directions, reinforcement removal of surplus soil , site clearance etc. (ii) GI earth strip
S&F energy efficient LED tube light fitting with tube 9/10 Watts [minimum 100 lumens per watts], 240 Volts, 50 Hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc. including connecting up with 1.0 Sq.mm. 3 core flexible copper conductor cable complete all as specified and directed.
S&F energy efficient LED tube light fitting with tube 20 Watts [minimum 100 lumens per watts] , 240 Volts, 50 Hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 Sq.mm. 3 core flexible copper conductor cable complete all as specified and directed.
S&F LED security light fitting with tube 30 Watt [minimum 100 lumens per watts] new generation energy saving & environmental friendly long life, made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening separate driver compartment with IP66 protection pre wired with 1.0 Sq.mm. copper conductor cable up to connector including 1.5m long GI tubing light grade of 32mm dia. bend to shape for fixing on wall/pole with suitable MS brackets nuts and bolts etc. complete all as specified and as directed.
S&F ceiling fans AC single phase 240 Volts of size 1200mm sweep with minimum delivery 210 cfm with service value, 6.00 BEE five star rated brushless direct current motor [BLDC] complete set with fixtures, metallic body complete all as specified and as directed.
S&F exhaust fan 250mm sweep 1350 RPM plastic body, complete with louvers suitable for operation on 240 Volts, 50 Hz AC supply fixed on wall making opening, fixing, making electrical connection from ceiling rose to fan through suitable copper flexible wire and making good the disturbed surfaces etc. complete all as specified and as directed.
S&F exhaust fan 300mm sweep 1400 RPM metallic body (Heavy duty), complete with louvers suitable for operation on 240 Volts, 50 Hz AC supply fixed on wall making opening, fixing, making electrical connection from ceiling rose to fan through suitable copper flexible wire and making good the disturbed surfaces etc. complete all as specified and as directed.
M&L earthing complete with GI plate electrode 60cmxx60cmx6mm thick, buried directly in ground (Earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI earth strip 25x4mm size by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 of SSR Part-I connected to earhing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C1 as in pit, 20mm dia. GI pipe medium grade for watering pipe, 40 mm bore GI light grade earth lead protection pipe, and 50mm thick RCC cover slab with handle, reinforced with 10mm dia. bars in both the directions, funnel, strainer, charcoal and testing on completion all as specified and as directed. Note: Rate quoted deemed to be include GI protection pipe, funnel, excavation and earth work, in any type of soil with PCC type C1 in bed and pit complete all as specified and as directed.
EXTERNAL WATER SUPPLY:
Supply and lay Ductile iron pipes of size 100mm dia, class K7 with spigot and socket/double end flanged end of any length conforming to IS specification laid in trenches including tighten rubber gasket complete all as specified and directed. Note: The above rate is inclusive of the following points (i) Pipeline should be securely anchored at dead ends, tees, bends, tapers and valves to resist thrust arising from internal pressure. Anchors and thrust blocks should be designed in accordance with IS : 5330-1984. (ii) DI fittings, excavation and PCC as required sahll be measured and paid separately under relevant items.
Supply and fix 300mm dia Cast Iron Double flange non rising type sluice valve of following sizes as per IS 14846, PN 1.0 with hand wheel Operation flange Drilling as per IS 1538 including rubber gaskets, MS bolts, nuts, washers etc., as required complete all as specified and as directed.
M&L for brick masonary valve chamber of size 900mmx900mmx900mm ( internal size) by providing PCC 1:2:8 tyepe D2 foundation 100 mm thick brick work in CM 1:4 plastering 15mm thickin CM 1:4 internal surfaces completely and external surfaces completely and external surfaces upto 150mm below GL, 75mm thick PCC 1:2:4 type B as in coping valve chamber cover made up of 40x40x5mm thick angle iron frame and 3.15 mm thick MS sheet cover complete excavation and lockeing arrangement and handle including painting steel surfaces with two coats of enamel paint over a coat of red oxide primer includingdismantling the existing damaged valve chamber and removing debris away from the premises etc complete all as specified and as directed.
M&L for brick masonary valve chamber of size 1.2mx1.2mx1.2mm ( internal size) by providing PCC 1:2:8 tyepe D2 foundation 100 mm thick brick work in CM 1:4 plastering 15mm thickin CM 1:4 internal surfaces completely and external surfaces completely and external surfaces upto 150mm below GL, 75mm thick PCC 1:2:4 type B as in coping valve chamber cover made up of 40x40x5mm thick angle iron frame and 3.15 mm thick MS sheet cover complete excavation and lockeing arrangement and handle including painting steel surfaces with two coats of enamel paint over a coat of red oxide primer including dismantling the existing damaged valve chamber and removing debris away from the premises etc complete all as specified and as directed.
Cast iron bends (any radius and angles) tappers any type (straight, bend, increasing ,decreasing or double socket)Tee pieces single branch 'Y' junction ,double branch ,cross (all socket orsocket spigot) collars, caps,caps & plugs for upto 300mm bore cast iron pipe with spigot and sockets end complete all as specified and as directed.
EXTERNAL ELECTRIFICATION:
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 150 sqmm 3.5 core complete all as specified and as directed
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 70 sqmm 3.5 core complete all as specified and as directed
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 16 sqmm 4 core complete all as specified and as directed
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size2.5 sq mm ,3 core, 1100 Volts grade passing through PVC Conduit/GI Pipe (from junction box to Street light/flood light/post top light/bollard light fitting
S&F LED street light fitting 35/36 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics by providing GI pipe medium grade 25 mm dia 1.5 Mtr in length with suitable size MS Clamp two nos made out of 25x3 mm FI, prewired and including connecting up with 3 core flexible copper conductor cable of 1.5 Sqmm complete with IP 65/66 protection complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique without damaging existing road/hard standing/walls and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed
Point wiring with 1.5 Sq.mm. FRLS PVC insulated unsheathed copper conductor single core multi stranded 1100 Volts grade, ISI marking drawn through and including non metallic PVC rigid concealed conduit and conduit accessories medium grade, ISI marked, including modular metal flush box with and including modular white cover plate with frame for mounting modular switches/sockets/fan regulators etc. including one run of 1.5 Sq.mm. PVC insulated unsheathed copper cable for earth continuity, connected to earth dolly complete all as specified and directed for One light point controlled by one switch or One fan (Ceiling fan/Exhaust fan) point controlled by one switch or One 3 Pin socket outlet 5 Amps on independent board complete all as specified and as directed.
Supply , Fixing and Testing Powder coated Outdoor street light control box of size not less than 280 x 200 x 100 mm CRCA 2 mm thick IP 65 , halogen free and weather proof for outdoor installation , in and including suitable terminal TPN SMC Connector for three phase Cable Line ( IN & OUT) , MCB 10 Amps SP 'C' Series , canopy weather proof hinged doors, allenkey locking system and arrangements for fixing on Steel Poles with MS clamps of suitable shape and size with nut, bolts and washers as per site requirement complete all as specified and directed by Engr In Charge.
Supply , Fixing and Testing PVC body heavy duty Post top/bollard light control box , in and including suitable terminal TPN SMC Connector for three phase Cable Line ( IN & OUT) , MCB 6 Amps SP 'C' Series , canopy weather proof hinged doors, allenkey locking system and arrangements for fixing on PCC/Steel Poles with MS clamps of suitable shape and size with nut, bolts and washers as per site requirement complete all as specified and directed by Engr In Charge (for gate light-2, garden light-12)
Distribution Transformer stepdown Level 3, 11 KV/0.433KV, Three Phase complying with IS: 1180/IEC-76(Part-1) 2014 with latest amendments no.4, Indoor type double copper wound suitable for 50 Hz system of capacity 160 KVA, oil immersed naturally cooled delta connected on HT side and Star connected on LT side ,Vector Group Dyn-11. provided with OFF load tap changer to vary secondary voltage from -7.5% to + 7.5% in step of 2.5%. Losses should be confined to the limits specified as follows: maximum allowable losses at full load (100 %) & Half Load (50 %) shall not be exceeded 513W & 1547W respectivly and as per GRIHA RATING, Percentage Impedance: 5%. Losses and Impedance are subjected to tolerance as specified in IS 1180. The transformers should be supplied with first filling of oil confirming to IS 335. The transformer should have both side cable end box with neutral brought out complete and installation of transformer shall be carried out as per IS-10028 and comprising with the following standerd fittings/Technical specifications : -
M&L for extention of busbar and insulator complete from existing VCB to proposed indoor VCB incl enclosure of bus couplar fitting jointing, nut and bolt etc all as specified and directed by Engr-in-Charge.
Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion esistant complete with driver, lamp and pole of suitable size not less than 1.5 mtr complete for garden light complete all as specified and as directed.
Supply, Installation, testing and commissioning of new 11 KV, 630 Amp Outdoor type load break switch (LBS) complete unit, extensible 1 way load break switch stand alone floor mounted, internal copper bus bars not less than 2 mm thick having MS Sheet Steel enclosure suitable for IP55 as per IEC 62271-200, LBS should complete with all accessories such as HRC fuse 11 KV- 3 Nos Manual Trip Push Button, terminal boots, Provision for receiving incoming/outgoing Cables through Bottom entry, including termination kit & glands, cable supports, all front cable terminations, mechanical indications for load break switch ON/OFF, Heater ON / OFF switch with filament type 200Watts space heater & thermostat, single phase switch with socket, Lamp for panel illumination with snap type door limit switch.Surge Arrester (9kV,10kA) including Control Wiring with appropriate size complete all as specified and directed with the following specifications as given :- Note : - (i) Factory inspection of load break switch and its testing shall be done by the representative of the Accepting Officer. (ii) The contractor shall produce drawing of load break switch (LBS) for according approval before the ordering of material to manufacturers.
Supply, install, testing and commisioning of copper wound
S&F Cable end jointing kit for indoor termination heat shrink type suitable for 3.5 core XLPE armoured aluminium conductor cable of 150 sqmm for complete with jointing material and accessories complete all as specified and directed by Engr In Charge
Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion esistant complete with driver and lamp complete for gate light complete all as specified and as directed.
(a) Lifting lug for transformer and tank. (b) Earthing terminal rating and diagram plate. (c) Air release device on main transformer tank. (d) Oil filling inlet pipe with plug. (e) Drain outlet pipe with brass gate valve. (f) Conservator tank with oil level indicator (g) Silica jel breather (i) First fill of oil upto level including conservator tank with fresh new oil conforming to IS335. (k) Type of connection Delta/Star (1) Type of cooling: Oil and Natural Air. (m) Vector group:DYN 11. (n) Temperature rise over an ambient of 50 °C maximum. (o) Air insulated Cable end box on both side for HT/LT cables of suitable size. (p) Provision of thermometer with pocket. (q) Provision of oil and winding temperature gauge. (r) Breather with silica gel with oil seal and first fill of silica gel (s) Rating diagram and terminal marking plate (t) Oil temp and winding temp indicator with maximum read pointer (u) Marselling Box
Supply, Install, test and commissioning Outdoor type cubical panel board self supporting totally enclosed CPRI certified factory fabricated LT feeder pillar box, made out of 3.0mm thick CRCA sheet steel with projected globe roof for rain water protection, dust and vermin proof, hinged front opening double door shutters with neoprene rubber gasket, powder coated including danger plate, Provn of connection of GI earth strip 32mm x 6mm size - 02 Nos, ventilation louvers, bottom detatchable gland plate complete cubicle panel board suitable for 3 phase 4 wire ,415 volts 50 HZ and 50mm x 50mm x 6 mm angle iron base frame, with locking arrangement, including provision of suitable size PCC M-15, type B1 pedestal for mounting of panel board fabrication of enclosure including base channel height outdoor type in and including the following Switch gear and necessary incl control copper cable flexible multi strand FRLS, Busbar supports, SMC finger/conical supports for vertical & horizontal bus bars,Fasteners ,bolts.,nuts incl vertical & horizontal bus bars, inter connection bus bar , Incomer & out going bus bar of 500 Amp rating 3 phase and neutral incl internal wiring and connections from bus bar to switch gear, testing on completion and commissioning complete all as specified and as directed internal wiring and connections from bus bar to switch gear, testing on completion and commissioning complete all as specified and as directed. :-(proposed to install near by the site)
(iv) Quotated rate include testing after completion from test point and the desired earth resistance shall be not more than 5 ohm .If the desired result is not obtained the earthing will be re done by the contractor at no extra cost.
switches shall be connected to control the auto operation based on delivery pressure, and panel shall support remote override control via Remote Control Panel. All wiring shall be done using color-coded FRLS copper wires with numbered ferrules. Cable alleys, gland plates, copper earthing busbar with terminals, and suitable terminal blocks for control and power cables shall be provided. All components shall be mounted on MS painted backplate with proper spacing and labeling. Testing, commissioning, insulation resistance test, and full load run test shall be conducted in presence of Engineer-in-Charge complete all as specified and as directed.
Taking down serviceable HT cable of size 185 sqmm 3 core and cable cover of any size/ type from site and kept in safe custody for relaying in new route out side of KV complex play ground area, the cost deemed to be included in the quoted rate for excavation, removal of cable and cable cover, cutting old existing cables, disconnecting cable joints and also taking up loop from the under ground carefully and making good the disturbed surfaces in all respect where ever required as per site requirement complete all as specified and as directed. (ATH HT UG cable and NORA HT UG cable)
Supply,laying XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor of size 120 sqmm 3.5 core, connecting with proper size Aluminium lugs, glands whereever necessary near ATC LT Panels to Bus bar chamber at ATC all as per site requirement , testing complete all as specified and directed. Make:- havells, Polycab, KEI,Gloster
Relaying of serviceable HT cable of any size as obtained from site complete all as specified and as directed.
Taking down serviceable LT cable and cable cover of any size/ type from site and kept in safe custody for relaying in new route out side of KV complex play ground area, the cost deemed to be included in the quoted rate for excavation,removal of cable and cable cover, cutting old existing cables, disconnecting cable joints and also taking up loop from the under ground carefully and making good the disturbed surfaces in all respect where ever required as per site requirement complete all as specified and as directed.
Supply,laying XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor of size 185 sqmm 3 core, connecting with proper size Aluminium lugs, glands whereever necessary near ATC LT Panels to Bus bar chamber at ATC all as per site requirement , testing complete all as specified and directed. Make:- havells, Polycab, KEI,Gloster
Materials & labour XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, 95 sqmm 3 core electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area complete all as specified and as directed.
Relaying of serviceable HT cable covers as obtained from site complete all as specified and as directed.
Relaying of serviceable bricks as obtained from site complete all as specified and as directed.
Supply and fix cable jointing kit for HT under ground cable for straight through joint heat shrink type and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 185 sqmm, complete all as specified and as directed. Make:- 3M, Denson, Raychem. (For Rerouting Cable)
Supply and fix cable jointing kit for HT end joint heat shrink Indoor type type and accessories suitable for 3 cor
e XLPE, armoured, Al conductor cable of size 185 sqmm, complete all as specified and as directed. Make:- 3M, Denson, Raychem. (For Rerouting Cable)
EACH JOB
Supply and fix cable jointing kit for LT under ground cable for cable for straight through heat shrink type and accessories suitable for 3 ½ core XLPE, armoured, Al conductor cable of size 120 sqmm complete all as specified and as directed.
Supply & Installation Voltage Stabilizer for automatic operation single phase natural air cooled indoor type and designed for input variation between 100 Volt to 290 volt
R O PLANT
with output voltage stabilized at 230 volt with accuracy +/- 2.5% and capacity 2 KVA complete all as specified and as directed. Make: V Guard VE 400 or equivalent in Microtek/Voltamp/Vinitec
Supply and fix cable jointing kit for LT under ground cable for end joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ core XLPE, armoured, Al conductor cable of size 120 sqmm, Indoor type complete all as specified and as directed. Make:- 3M, Denson, Raychem.
AIR CONDITIONING:
Supply and install 5 KVA wall mounted voltage stabilizer for automatic operation single phase nautrally air cooled indoor type and designed for input variation between 130 Volt to 280 Volt with output voltage stabilised at 230 Volt with accuracy +2.5% including provision of volt meter for monitoring input and output voltage and bypass cut out switch complete all as specified and directed. Make: V-Guard/Purevolt/Voltas/Krykard
Supply and fix plug and socket SPN enclosure with a two pin and earth complete with one MCB SP 32 Amps 'C' curve 10 KA breaking capacity of 240 Volts complete all as specified and directed.
Supply, fabricate, install and testing outdoor type LT bus bar chamber box of size 800x600x400mm from CPRI certified panel manufacturers including provision of dimrail for mounting 1 No of MCCB incl S&F MCCB 250 Amp 4 Pole, 415 V, Adjustable type, with breaking capacity 36 KA, hinged door with allen key locking arrangement made out of 3mm thick CRCA sheet steel powder coated with front and rear opening slanting cannopy on roof and mild steel channels base frame angles of 50x50x5mm in and including TPN aluminium bus bar of 250A capacity for looping and branch connection, the bus bar placed on suitable capacity insulators including danger notice plate on both side, neoprene rubber gasket to make it completely dust and vermin proof the same will be fixed in ground with necessary PCC foundation made by (1:2:4) type B1 complete all as specified and directed by Engr-in-charge. Note - (1) The cost deemed to be included in the quoted rate for reconnecting Old existing cables to boxes carefully using a suitable glands and also taking up loop from the under ground and making good in all respect where ever required as per site requirement complete all as specified and as directed.
Supply and fix Reverse Osmosis Plant stainless steel, 240 volts, Full automatic, 60-65% to 95% purity level, of out put capacity of 60 Litres per hour with RO+TDS technology including inlet valve set, spanner for bowl, inlet and reject pipe and all connected items, Auto shut off and start syetem, overflow protection complete all as specified and as directed.
WATER COOLER
LIGHTENING PROTECTION
Supplying and fixing smart three phase four wire dual source prepaid energy meters BIS 15884 marked in existing meter board / floor panels with pre payment capacity touch keypad based digital having current range 10-60 Amp 415 Volt accuracy class 1.0 alongwith parallel home display split unit with inbuilt load control switch containing provision for TOD and RTC, inbuilt feature to sense the DG mode through PLSI, dual source registration wrt grid as well as DG supply and dynamic load allocation facility from grid and DG, capable to define for tariff slabs, happy hours and holiday definition complete all as specified and as directed.
rate include testing after completion from test point and the desired earth resistance shall be not more than 2 ohm .If the desired result is not obtained the earthing will be re done by the contractor at no extra cost.
Supply & Installation Voltage Stabilizer for automatic operation single phase natural air cooled indoor type and designed for input variation between 90 Volt to 300 volt with output voltage stabilized at 230 volt with accuracy +/- 2.5% and capacity 5 KVA or 15 Ampere complete all as specified and as directed. Make: V Guard VE 500 or equivalent in Microtek/Voltamp/Vinitec
FIRE FIGHTING:
CA No.CE (Navy)/VIZ/ ARK/ of 2025-2026
Lump Sum price worked out by the contractor for 'R O PLANT AND SPECIAL iTEMS', as listed in Schedule 'A' Part-XII
Supply and fix Epoxy insulator of size 25 mm X 3 mm for fixing of aluminium strip on wall/ roof/ pole etc complete all as specified and as directed.
Supply and installation of fire brigade connection consisting of 02Nos of 63mm dia instantaneous male coupling with built in check valve, sluice valve and non return value complete all as specified and directed.
M&L for supply and laying control cable of size 12 core x 1.5 sqmm, 1100 V grade, copper conductor, PVC insulated, armoured, and overall sheathed, laid on wall/surface using heavy-duty MS saddles and spacers at regular intervals not exceeding 0.6m, fixed with suitable rawl plugs and screws, including termination at both ends with compression type brass glands and crimping type copper lugs, testing on completion, complete all as specified and directed.
S &F Copper tube with insulation for suction and discharge line combined (same size as for the AC installed ) for connection between indoor and outdoor unit (beyound 3 mtr) complete all as specified and as directed.
Supply of 12V 7Amp Batteries with rechargeable complete all as specified and directed.
Supply and install Water flow switch complete all as specified and directed.
S & F 4 core 4 Sq mm muti stranded copper conductor cable for connection between indoor and outdoor unit (beyound 3 mtr) complete all as specified and as directed.
Supply, laying, and fixing of 2 Core x 1.5 sqmm FRLS copper conductor cable (ISI marked) conforming to IS:1554 Part I, drawn through heavy-duty FRLS ISI-marked PVC conduit of not less than 20 mm dia, complete with all accessories such as bends, junction boxes, inspection boxes, conduit fittings, and concealed in walls/floors/ceilings including cutting, fixing, clamping, making good to the original finish and testing as required complete all as specified and as directed.
Supply and fix 6 Kg Fire Extinguisher Dry Chemical Powder (ABC) Type complete all as specified and as directed.
Supply and fix 3 Kg Fire Extinguisher CO2 Type (light weight squeeze grip type) complete all as specified and as directed.
Supply and fix 9 Ltr Fire Extinguisher water stored pressure type complete all as specified and as directed.
Supply and fix 4 Kg Fire Extinguishers clean Agent Type complete all as specified and as directed.
Supply and fix 9 Kg Fire Extinguisher Dry Chemical Powder (ABC) Type complete all as specified and as directed.
SEWAGE DISPOSAL:
Supply and fix 9 Ltr Mechanical Foam Extinguisher (stored pressure type) complete all as specified and as directed.
Supply and fix fire bucket (Dry sand) complete all as specified and as directed.
LIGHTNING PROTECTION:
S&F epoxy insulator of suitable size for fixing of aluminium strip on wall/roof/pole etc. complete all as specified and as directed.
Supply and fix bucket stand for 02Nos complete all as specified and as directed.
Supply and fixing fire instruction board of size 18 inch x 24 inch made from 3mm thick PVC / ACP sheet, duly printed in English and Hindi with clear fire safety instructions titled “IN CASE OF FIRE / IF FIRE OCCURS,” including emergency contact numbers, evacuation procedures, pictograms, and assembly point information. The board shall have photoluminescent text and symbols, be mounted on wall at eye level using brass screws and PVC sleeves, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of fire safety signage boards made of PVC/UPVC, 12”x6” size (or as directed), marked on both sides using reflective or photoluminescent tape/paint, including wording for fire hydrant, fire extinguisher, fire exit, hose reel, manual call point, etc., and suitable hanging/wall fixing arrangements, complete all as specified and directed.
ARBORICULTURE
M&L for Poeta soil (garden soil) mixed with requisite quantity of pesticides and fertilizers while filling (stack measurements shall be considered for payment)
M&L for dry gober manure mixed with requisite quantity of pesticides and filled along with the garden soil in alternate layers (stack measurements shall be considered for payment)
Supply and planting dry American/ Korean grass in mud patches and watering all as specified and as directed.
Supply and Planting of hedges like Aakalita Aspar/Duranta varigated by digging in trenches of size 300mm wide and 300mm deep and filling soil obtained from same location upto 200mm height and balance 100mm depth filled with garden soil and manure mixed in the required proportion and planting hedges of height 300mm above GL and removal of soil, debris, weeds to a distance exc 250m and n.exc 500m and watering etc complete incl 3 years maintenance complete all as specified and as directed by the Engineer-in-Charge.
Supply and Planting Semi studded plants like Golden Tum/Mananta varieties as per argus/mery aglonima draft varieties by digging in trenches of size 300mm wide and 300mm deep and filling garden soil and manure mixed in the required proportion and watering etc incl 3 month maintenance complete all as specified and as directed by the Engineer-in-Charge.
stage.html
html • 0.02 MB
tech_bid_open.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.75 MB
BOQ_832752.xls
BOQ • 0.37 MB
88757_Tender.pdf
Tender Documents • 2.56 MB
88757_Schedules.pdf
Additional Documents • 0.77 MB
88757.pdf
PDF • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .