| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹85.8 LAccepted-AOC 67 KAILASH VIHAR TIWARIPUR BAGIA JAJMAU KANPUR 208010 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208010 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹87.3 L+₹1.6 L (1.83%)Rejected-AOC HOUSE NO 41 WARD NO 09 ARYA SAMAJ GALI UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L2 | Rejected-AOC NOT BEING LOWEST | |
| 3 | L3₹94.9 L+₹9.1 L (10.6%)Rejected-AOC | L3 | Rejected-AOC NOT BEING LOWEST | |
| 4 | L4₹96.0 L+₹10.3 L (12.0%)Rejected-AOC 25 A RR SAMY LANE KATTOOR COIMBATORE 641009 | COIMBATORE | COIMBATORE | TAMIL NADU | 641009 | L4 | Rejected-AOC NOT BEING LOWEST | |
| 5 | L5₹96.7 L+₹11.0 L (12.8%)Rejected-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L5 | Rejected-AOC NOT BEING LOWEST |
| Sl No | Description | Qty | Unit | devan enterprises L5 | B5BUILDING SOLUTIONS L3 | rvelectricals L4 | Ashirwad Contractor and Supplier L1 | Shiva Shakthi Electrical Enterprises L7 | M/S N K POWER SYSTEMS AND PROJECTS L2 | Roy and Sons Infrastructures L6 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and installation of silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS : 13364 complete with foundation (as per OEM design), control panel with necessary meter and sound proof canopy as per CPCB norms of capacity 40 KVA with outdoor AMF Panel with following detailed Specifications Complete all as specified and directed | 1 | Each Job | 8,00,000 ₹8,00,000 | 8,64,000 ₹8,64,000 | 9,25,886 ₹9,25,886 | 8,25,000 ₹8,25,000 | 8,46,000 ₹8,46,000 | 7,89,526 ₹7,89,526 Lowest | 10,00,000 ₹10,00,000 |
| 1.01(A) Diesel Engine :- Diesel Engine shall be 4 stroke liquid cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator IS:10001/ 10002,ISO 8528-1 , ambient temprature of 50°C ,50% RH & at 1000m above MSL, turbo charged, Governing class as per ISO 8528 part-V,engine capacity of 10% overload for one hour in every 12 Hours of continuous operation , shall have noise limit of <75dB at 1 metre complied with CPCB and Environmental norms. The OEM shall undertake type approval and conformity of production certificate for emission standard for engine from agencies approved by GoI. Copy of the same shall be produced. | ||||||||||
| 1.02(B) Protection to Genset :- i) Low lube oil pressure warning/shutdown (ii) High engine temp warning/shutdown (iii) Low coolant temp warning (iv) Radiator fan Belt Failure indication/shudown (v)Low/High battery voltage warning | ||||||||||
| 1.03(C) Alternator :- Synchronous alternator copper wounded rated 40 KVA, 415 Volts, 1500 RPM, 3 Phase 4 wire system , 50 Hz, AC Supply with 0.8 lagging power factor at 50 degree c, 50% RH and at 1000 m MSL, brushless type, self exicited, continuous duty, sel regulated through AVR conforming to IS:4722 with Class F/H insulation as per IS: 13364 . The salient feature are as under : (i) Permanent lubricating bearing (ii) Permissible overloading of 10% for one hour in every 12 hrs of contineous operation (iii) Permissible unbalancing capability minimum 25% per phase | ||||||||||
| 1.04(D) AMF Panel (out door type) :- (i) Digital Amf controller with control relay such as mains faulier relay,under/over voltage protection relayl, under/over frequency relay, Reverse power protection relay (ii) switch gears such as MCCB,Power Contactor,Fuse (iii) Metering,control switches (vi)Weak battery warning (vii) Fail to start shutdown (viii) Cranking lockout | ||||||||||
| 1.05(E) ACCOUSTIC ENCLOSURE FOR DG SET :- Supply and fixing accustic enclosures Outdoor type suitable for 40 KVA capacity diesel Generator set duly fabricated of channel and CRCA sheet of required size having doors , insulation sides and top by minral rock wool confirming to IS-8183 of adequate thickness accoustic louvers /outlet. ventilation system etc . complete as per manufacturers instructions with wiring and lighting arrangements duly painted synthetic enamalled paint over a primer coat or as directed of suitable size all as required at site and comprising of the following :- | ||||||||||
| 1.06(i) Base: MS channel fabricate MS channel made out of 5 mm thick MS sheet (ii) Structure heavy duty rectangular MS box channel . (iii) Doors fabricated from MS CRCA sheet with air tight with neoprene rubber gasket and gun metal heavy duty spring loaded locks . (iv) Out side cover: Made out of CRCA sheet (v)Accustic insulation ( side &Top ) sound proofing minerla rock wool slab thickness 100mm of density 96Kg/m3 confirming to IS 8183 , covered by fire Resistant fiber tissue as per manufacturer recommandation (vi) Inside cover : CRCA perforated sheet powder coated (vii) Inspection port : Aluminium frame with double walled glass fixed type sealed with neoprene rubber gasket for viewing instrument panel (viii) 180 AH/12V - 01 Nos maintenace free batteries. | ||||||||||
| 1.07(F) FUEL TANK :- One No of sheet metal steel tank made out of 3.0 mm thick MS sheet of suitable capacity of hold diesel sufficient for 12 hours running at full load, tank shall be fitted with in canopy and balace fuel tank to be kept outside of canopy with lock system as per manufacturer's design including the following:- (i) Level indicator to indicate level of diesel in tank. (ii) Drain plug with 2.0 mtrs pipe for drain oil. (iii) fuel strainer. (iv) Pipe for fuel. (v) Air vent. (vi) Mannually operated one no. fuel pump. | ||||||||||
| 1.08(G) NOTE :- (a) Generating set will be placed on suitable foundation as recommended by manufacturer and cost thereof shall be included on the prices quoted this includes excavation and earth work for foundation, compaction, sub-base, base, RCC/PCC works all as directed by Engr-in-Charge (b)Tools shall be supplied with DG set unit as per manufacturer,s instructions and cost thereof shall be included in the price quoted . (c) DG Set shall be placed at the site directed by Eng-in-charge (d) Testing of DG set shall be done as per relavent clause of PS. | ||||||||||
| 2.00 | Supply and installation of silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS : 13364 complete with foundation (as per OEM design), control panel with necessary meter and sound proof canopy as per CPCB norms of capacity 125 KVA with outdoor AMF Panel with following detailed Specifications Complete all as specified and directed | 1 | Each Job | 17,25,000 ₹17,25,000 | 14,80,000 ₹14,80,000 | 13,07,387 ₹13,07,387 Lowest | 15,49,000 ₹15,49,000 | 17,01,000 ₹17,01,000 | 16,09,999.73 ₹16,09,999.73 | 16,60,000 ₹16,60,000 |
Tender Value
Refer Docs
EMD Value
₹1.6 L
Closing Date
8 Oct 2025, 6:00 pmClosed
COL RAJENDER KUMAR
CWE AF NORTH BANGALORE BELLARY ROAD JC NAGAR POST
SPECIAL REPAIR FOR REPLACEMENT OF DG SETS (05 NOs) AGAINST DECLARED BER AT CHAFB UNDER GE (AF) BANGALORE
2025_MES_729070_1
87404CWEAFNBAN
Open Tender
Civil Works
Item Rate
270 days
GE (AF) BANGALORE
AS PER NIT
7 documents required · 7 mandatory
₹1,000
GE (AF) BANGALORE
₹1.6 L
Yes
18 Nov 2025
3 Sept 2025
15 Oct 2025
4 Sept 2025
8 Oct 2025
24 Sept 2025
4 Sept 2025 - 17 Sept 2025
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .