Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 LAccepted-Finance 19 A DURGA BARI SADAR BAZAR MEERUT MEERUT MEERUT UTTAR PRADESH 250001 | MEERUT | UTTAR PRADESH | 250001 | L1 | Accepted-Finance OK | |
| 2 | L2₹6.2 L+₹1.9 L (45.0%)Accepted-Finance | L2 | Accepted-Finance OK | |
| 3 | L3₹6.3 L+₹2.0 L (46.9%)Accepted-Finance 2ND FLOOR SHOP NO 303 MARUTI PLAZA RONCHI BANGAR TOWNSHIP MATHURA | MATHURA | UTTAR PRADESH | 281001 | L3 | Accepted-Finance OK | |
| 4 | L4₹6.8 L+₹2.5 L (58.5%)Accepted-Finance | L4 | Accepted-Finance OK | |
| 5 | L5₹7.1 L+₹2.8 L (65.7%)Accepted-Finance | L5 | Accepted-Finance OK |
Tender Value
₹9 L
EMD Value
₹10,000
Closing Date
17 Apr 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE ETC NOIDA
220 KV SUBSTATIONS SECTOR-20 NOIDA
Strengthening of 33 kV main bus bar by Twin Moose Conductor AT 132 kV S/S Sector-115 Noida under ETD-I Noida
2023_UPTCL_793360_1
E-T-78/ETCN/2022-23
Open Tender
Electrical Works
Item Rate
30 days
NOIDA
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
EE ETD NOIDA
₹10,000
26 Apr 2023
3 Apr 2023
18 Apr 2023
3 Apr 2023
17 Apr 2023
3 Apr 2023
Amount
Work Portion
Dismantling of R, Y & B phase of 33 KV Main Busbar I,III,IV & V made of single tarantulla & Zebra conductor between bus section below gantries,step by step during bus bar strengthening work per saction per phase carefully as neighbour section may be charged including opening/cutting of PG clamps/isolator clamps and all associated works. After dismantling all scrap material shifting site to store. including cost of All T&P and labour.
Opening/cutting of existing jumpers from 33kV mainbus bar-I,III,IV&V and all associated clamps,step by step during bus bar strengthening of various size & capacity conductors.including cost of All T&P and labour.
Stringing and proper sagging of 33 KV New Main Busbar I,III,IV&V by Twin Moose conductor including shifting of all material from store to work site. and fitting of tension clamp, per saction per phase hosting of disc insulator,tension fitting, fired wedge type "C" connector (RPG make) clamps, cutting of conductor,and Spacers etc.Including cost of All T&P and labour.
Reconnecting jumpers of R, Y & B phase from 33 KV Main Busbar to isolators by twin moose/panthor conductors after fitting of Fixing of fired wedge type "C" connector (RPG make) suitable for moose panther/moose to moose conductor having 2000/1250amp capacity. isolators clamp and specers. including shifting of all material from store to work site. Including cost of All T&P and labour.
Reconnection of main bus-bar below gantry in bus section step by step replacement of 33kV main bus I & III,IV,V of Moose conductor by required clamps,fittings and spacers as required to complete the work in all respect.
Supply Portion
Bolted type Tension fitting suitable for twin Moose conductor with Turn buckle (70 KN disc insulator) made of with HDG hardware fitting,D-shackle,D-socket Ball hook york plate, D-clip tension clamp.with complete assembly As per technical specification.
Bolted type Tension fitting suitable for twin Moose conductor without Turn buckle(70 KN disc insulator) made of with HDG hardware fitting,D-shackle,D-socket Ball hook york plate, D-clip tension clamp.with complete assembly As per technical specification.
Fired wedge type "C' Connector (RPG make) Suitable for Moose to Moose Conductor Having 2000 Amp. Capacity
Fired wedge type "C' Connector (RPG make) Suitable for Moose to Panthor Conductor Having 1250 Amp. Capacity
2-Bolt 250 mm specing spacer for twin moose conductor as per technical specification/Sample
1-Bolt 100 mm specing spacer for twin Panthor conductor as per technical specification/Sample
2-Bolt 100 mm specing spacer for twin Moose to Moose conductor as per technical specification/Sample
Bimetalic 33kV isolator clamp made of alluminium alloy LM-6 complete with GI nuts,bolts and washers suitable for ACSR Twin Panther conductors 1250Amp as per technical specification/sample.
Bimetalic 33kV isolator clamp made of alluminium alloy LM-6 complete with GI nuts,bolts and washers suitable for ACSR Twin Moose conductors 2000Amp. as per technical specification/sample.
Meena Elect & Engg. Works
P&H Engineering
R.K.Engineers & Traders
BARKATI ENTERPRISES
M/S DHARMENDRA CHAUDHARY
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .