Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹63.1 LAccepted-AOC MILITARY HOSPITAL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC Lowest and reasonable | |
| 2 | L2₹69.4 L+₹5.1 L (7.87%)Rejected-Finance B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹74.6 L+₹10.2 L (15.9%)Rejected-Finance 15 BOH ROAD DEFENCE ENCLAVE AMBALA CANTT 133001 HR | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹78.3 L+₹14.0 L (21.7%)Rejected-Finance BIR SARDALIA RESIDENCY AIR FORCE ROAD BARYAL UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹79.1 L+₹14.7 L (22.9%)Rejected-Finance 94 PHASE II HOUSEING COLONY UDHAMPUR J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹1.1 Cr
EMD Value
₹1.8 L
Closing Date
3 Jun 2024, 6:00 pmClosed
HQ CWE (AF) Jammu
Headquarters, CWE (AF) Jammu, Near Gurdwara Sahib and Mandir, Airforce Station Satwari, Jammu. Pin - 180 003
SPECIAL REPAIR TO CERTAIN OTM BUILDING, SECURITY WALL AND GUARD POSTS AT AF STN UDHAMPUR
2024_MES_650310_1
CWEAFJ-41/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Udhampur
All as per Tender Documents
9 documents required · 9 mandatory
₹1,000
GE (AF) Udhampur
₹1.8 L
Yes
2 Sept 2024
17 Apr 2024
5 Jun 2024
17 Apr 2024
3 Jun 2024
20 May 2024
Amount
B/R Work:- Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified.
Rendering 15mm thick in two layers (base layer 10mm & finishing layer 5mm thick) in cement mortar (1:4) using liquid water proofing compound in finishing layer on brick work or concrete surfaces of wall, surfaces finished even and smooth using extra cement, etc complete all as specified & directed. (Note : WPC shall be measured and paid separately)
Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and smooth w/o using extra cement complete all as specified and directed.
M&L for 5mm thick rendering in cement mortar 1:3 on concrete surfaces, ceiling etc finished surface even and smooth, without using extra cement complete all as specified and as directed.
Preparation of newely plaster surface of wall and applying two coats of cement base paint over a coat of primer in camauflage pattern complete all as specified and as directed.
Preparation of newly plastered wall surfaces and applying two coats of oil bound distemper over a coat of 3mm wall care putty preparatory to distempering including preparation of surface complete all as specified and as directed.
Preparation of newly plastered surfaces and applying two coats of white wash on ceiling complete, all as specified and as directed.
Demolition of Stone slabs and tiles laid, bedded and pointed in any mortar of any description or thickness in floors, aprons etc.
Demolition of cement concrete (unreinforced) as in ground floors and pavings n exc 15cm thickness.
M&L for Cement concrete type B-1, 1:2:4 (20 mm graded crushed stone aggregate) 25mm thickness as in floor for laying tiles, complete all as specified and as directed.
Non - skid coloured Ceramic colour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over a screed bed 15mm thk in CM 1:6 complete all as specified and as directed.
Non - skid coloured Ceramic colour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in skirting/dado, set and jointed in neat cement slurry and pointed in coloured cement to match the surface incl. 10mm thick plaster in CM 1:3 complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified.
S&F in repair for coloured glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the surface incl 10 mm thick plaster in CM 1:3 complete all as specified colour and design approved by Engr-in-Charge.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid dry or laid dry and pointed complete all as specified and as directed by Engineer-in-Charge.
Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 40 mm thickness, M-35 Grade with grey cement and pigment complete all as specified and as directed
Sand cushioning 25mm thick under floor or in foundation including watering and consolidation, complete all as specified and as directed.
M&L for Plain cement concrete type D-2, 1:4:8 (40mm graded crushed stone aggregate) 75mm thickness as in floor, paving, sub- bases etc. complete all as specified and as directed.
M&L for Plain cement concrete 1:3:6 type C-1 50mm thick (using 20mm graded crushed stone aggregate) as in plinth protection finished the concrete surface even and smooth without using extra cement complete all as specified and as directed.
Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Mild steel TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Providing Precast cement concrete in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain fair faces, including chamfers weatherings throating etc. and setting in mortar complete with joints to match, type B-1 1:2:4 (20mm graded aggregate) Set in CM 1:4 complete all as specified and directed.
S&F in repair Vitreous china Wash Hand Basin size 550x400mm (flat back or angle back type) including 32mm dia brass chromium plated waste fitting a pair of cast iron bracket duly painted/erecting stand including cutting and pinning in ends making good disturbed surfaces in CM 1:3 including taking down unserviceable wash hand basin and connected items of any description, complete all as specified.
S&F in repair Vitreous china wash down water closet Pan (pedestal Pattern) white colour (excluding fixing bolt, flushing cistern and flush pipe) size 580 x 440mm with integral foot rest connecting flushing cistern and flush pipe in repair complete all as specified and as directed.
S&F Seat and cover for pedestal pan white / black closed pattern with flat bottom and cover and MS chromium plated aluminium hinge device in repair, complete all as specified and as directed.
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position in repair complete all as specified and as directed.
S&F PVC Flushing Cistern 10 litre capacity low level valve less, symphonic action type white with inlet, ball valve, float and handle including 32mm dia PVC Flush pipe a pair of cast iron brackets duly painted/erecting stand including cutting and pinning in ends, making good disturbed surfaces in cement mortar 1:3 including taking down unserviceable flushing cistern complete all as specified and directed.
S&F in repair Angular Stop/Angle valve fancy type chromium plated,screwed down, high pressure with crutch or butterfly handle 15mm bore complete all as specified and as directed.
S&F in repair Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed iron pipe 15mm bore complete all as specified and as directed.
S&F in repair Bib taps cast copper alloy , 15mm bore, fancy type Chromium Plated , screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed.
S&F in repair Stop valves fancy type ,15mm bore, chromium plated with long shank and cup (concealed type) complete all as specified and as directed.
S&F in repair Chromium plated shower roses 125mm including shower arm of suitable length with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed.
S&F in repair PTMT towel rail 600mm long fancy type fixed with and including chromium plated brass screws and plastic cleats complete all as specified and directed.
S&F in repair CP soap dish fixed in wall complete all as specified and as directed.
S&F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with CP bracket guard and railing 60cm long complete all as specified and as directed.
S&F in repair PTMT grating doom 100mm dia(minimum weight 25 gms) complete all as specified and directed.
PVC connections 15mm size with PTMT Nuts of length 450mm and fixed including taking down unserviceable PVC Connections, complete all as specified and as directed.
S&F in repair PVC (SWR) pipes, 110mm dia, single socketed, in any length with rubber ring joints, fixed to walls/laid in trenches or floor complete all as specified & directed.
S&F PVC (SWR) bends 110mm bore in repair complete all as specified .
S&F in repair PVC (SWR) pipes, 75mm dia, single socketed, in any length with rubber ring joints, laid in trenches or floor complete all as specified & directed.
S&F in repair PVC (SWR) 75mm floor trap, plain with grating including jointing with solvent cement complete all as specified .
Taking up or down 15mm bore of steel tubing with connections for cleaning for refixing or removing to store/yard complete all as specified .
Steel water tubing of nominal bore 15mm medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtrs in deep for foundation etc, or for shafts,wells, cesspits, manholes etc,not exceeding 10 Sqm on plan and n. exc 1.5m in depth and getting out in any type of soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point, spreading and leveling complete all as specified and directed by Engineer-in-Charge.
Demolition and breaking up 150mm internal dia drain pipes (salt glazed stone ware, AC or Reinforced concrete pipes) set in cement mortar complete all as specified and as directed by Engineer-in-Charge.
M&L for Plain Cement Concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in bed of drain pipes 150mm bore, laid to falls including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed by Engineer-in-Charge.
M&L for DWC (Double walled Corrugated) drain pipes non pressre with OD 160-180mm and ID 132-150mm, laying pipes in level or to falls in trenches, on concrete bed or directly on hard grounds, jointing as per manufacturer's instructions and testing, complete all as specified and as directed
Cutting into existing manholes for connecting new drains pipes of 100/150mm internal dia and making good to pipe and rendering , cutting out existing benching for and forming branch channel ( ½ round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required internal dia of pipe 100/150 mm bore, complete all as specified and as directed
Supply only liquid water proofing compound complete all as specified and as directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS.1161- 1979 grade St.-240 complete all as specified and directed.
Rolled mild steel Fe-410W (Gde E 250 quality A) in Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated complete all as specified and directed.
Preparation of new or previously untreated steel surfaces of any description, over 10cm width or girth and applying two coats of synthetic enamel paint, over a coat of red oxide primer, complete all as specified and directed.
Demolition of brick work or stone masonry built in cement mortar including all quoines arches,pillar etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and directed .
Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed.
M&L for Plain cement concrete type C-2 1:3:6 (40mm graded crushed stone aggregate in surface channels and drains complete all as specified and directed.
M&L for Providing, cement concrete type B-1 1:2:4 (20mm graded crushed stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete all as specified and directed.
S&F 4mm dia galvanised steel wire, 150x100mm mesh, made up into mattresses or cages, lapped, wired and laid in position, including closing after filling complete all as specified and directed.
M&L for boulder filling dry, handpacked tightly, as in wire crate apron bunds (Wire crate measured separately) complete all as specified and directed.
S&F in repairs galvanised. 2 strand, steel Barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails , including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and as directed.
S&F Concertina coil of dia. 450 mm upto 3 RM height of wall with existing 'Y' angle placed 2.4 m to 3.0 m apart, with GI clips/GI wire or GI barbed wire fixed to angle iron complete all as directed & specified.
Dismantling expanded metal/Concertina coil any thickness or mesh, fixed with steel or wood fillets, if any (weight per sqm Not exc. 4 Kg) complete all as specified and directed
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed
Rolled mild steel in Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe-410W (Gde E 250 quality A) complete all as specified and directed.
Mild steel, plain, black sheet, 1.25 mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed
E/M Work:-
Taking down carefully aluminum/copper point wiring (light/ fan/socket or power) complete ,including fixture and fittings such as switches,ceiling roses,pendants ,reguators socket,light fitting etc removing materials to store for keeping in safe custody or for taking credit( credit for above items should be made as per conditions separtely) and making good disturbed surfaces of walls,floors etc. complete all as specified and directed
Point wiring complete with PVC insulated and unsheathed FRLS cable 1.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'medium grade' PVC conduit for point wiring concealed in wall/false ceiling with pressed steel concealed Sunken boxes not less than 1.6mm thick of reqd size (factory painted) and with top cover 3 mm thick of Hylam sheets of required colour, painting Sunken boxes inside and out side with one coat of red oxide primer complete including 1.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed.
One light/Fan/Exhaust fan point controlled by one switch
One bell/buzzer point controlled by one push button on the same board with other switches or independent
One 5 pin 5 Amp switch socket out let point on the same board with other switches
One 5 pin 5 Amp switch socket out let point on an independent board
Point wiring complete with PVC insulated and unsheathed FRLS cable 1.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'medium grade' PVC conduit for point wiring in existing conduit with pressed steel concealed Sunken boxes not less than 1.6mm thick of reqd size (factory painted) and with top cover 3 mm thick of Hylam sheets of required colour, painting Sunken boxes inside and out side with one coat of red oxide primer complete including 1.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed.
One light/Fan/Exhaust fan point controlled by one switch
One 5 pin 5 Amp switch socket out let point on the same board with other switches
One 5 pin 5 Amp switch socket out let point on an independent board
Point wiring complete with PVC insulated and unsheathed cable 4.0 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'pvc conduit pipe for point wiring in concealed in wall/false ceiling with pressed steel concealed Sunken boxes not less than 1.6mm thick of reqd size (factory painted) and with top cover 3 mm thick of Hylam sheets of required colour, painting Sunken boxes inside and out side with one coat of red oxide primer complete including 4.0 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed.
Point wiring complete with PVC insulated and unsheathed cable 2.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'medium grade' PVC conduit for point wiring in concealed in wall/false ceiling with pressed steel concealed Sunken boxes not less than 1.6mm thick of reqd size (factory painted) and with top cover 3 mm thick of Hylam sheets of required colour, painting Sunken boxes inside and out side with one coat of red oxide primer complete including 2.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed.
Point wiring complete with PVC insulated and unsheathed cable 2.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'medium grade' PVC conduit for point wiring in Existing Conduit with pressed steel concealed Sunken boxes not less than 1.6mm thick of reqd size (factory painted) and with top cover 3 mm thick of Hylam sheets of required colour, painting Sunken boxes inside and out side with one coat of red oxide primer complete including 2.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed.
Point wiring complete with PVC insulated and unsheathed cable 2.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'medium grade' PVC conduit for point wiring in Surface PVC Conduit with pressed steel concealed Sunken boxes not less than 1.6mm thick of reqd size (factory painted) and with top cover 3 mm thick of Hylam sheets of required colour, painting Sunken boxes inside and out side with one coat of red oxide primer complete including 2.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed.
S&F Bell switch AC, 230 Volt single pole in repaircomplete all as specified & directed.
S&F Switch piano, flush type, 5 amps single pole, one way in repair complete all as specified & directed.
S&F Socket piano, flush type, 5 amps flush type in repair complete all as specified and directd.
S&F Switch socket combination 5 in 1 , flush type, 16 amps in repair complete all as specifeid and directed.
S&F in repairs of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. As per existing make requied complete all as specified and directed.
Taking down fan,celling cable end dismantling blades and removing fan and blade to complete all as specified & directed.
Fixing only ceiling fan (MD supply) and connecting up including provisionsion of cable from ceiling rose or connection to fan complete all as specified & directed.
S&F in repair Bell ,Ding dong AC 230 Volts single pole complete all as specified and directed.
S&F in repair ceiling rose 3 phase /PVC/polycarbonate,isolated body complete all as specified and directed.
S&F in repair Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 16.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 16.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through rigid Surface concealed PVC conduit, heavey duty and connected to main board and making good disturbed surface complete all as specified and as directed. Note: Two runs each of 16.00 sqmm main cable and one RM of 16.00 sqmm cable as earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
S&F in repair Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 10.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 10.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through rigid Surface concealed PVC conduit, heavey duty and connected to main board and making good disturbed surface complete all as specified and as directed. Note: Two runs each of 10.00 sqmm main cable and one RM of 10.00 sqmm cable as earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
M&L in repair Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through rigid Surface concealed PVC conduit, heavey duty and connected to main board and making good disturbed surface complete all as specified and as directed. Note: Two runs each of 4.00 sqmm main cable and one RM of 4.00 sqmm cable as earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
M&L in repair Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through rigid Surface concealed PVC conduit, heavey duty and connected to main board and making good disturbed surface complete all as specified and as directed. Note: Two runs each of 6.00 sqmm main cable and one RM of 6.00 sqmm cable as earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
S&F in repair Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through rigid Surface existing conduit, heavey duty and connected to main board and making good disturbed surface complete all as specified and as directed. Note: Two runs each of 4.00 sqmm main cable and one RM of 4 .00 sqmm cable as earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
M&L in repair Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through rigid Surface existing conduit, heavey duty and connected to main board and making good disturbed surface complete all as specified and as directed. Note: Two runs each of 6.00 sqmm main cable and one RM of 6 .00 sqmm cable as earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
M&L Wiring for circuit 2 core 2.5 sqmm copper conductor PVC insulated PVC sheated as per is 694 up to date all including drawing through steel Conduit making connection with LED Hanger Light / Bulk Head light fitting up to 20 mtr height bracket,fastners ,screw nut bolt etc complete all as specified and as directed by enginer in charge Note : Light fitting shall be connnected each fitting shall be connnected with ceiling rose and junction box /PVC connector etc shall be included in the quoted rate ie Nothing shall be paid extra amount to the contractor .
S&F in repair Sheet metal enclosures for DBs SPN 4 way flush mounted including accessories therein and disposing off complete all as specified and directed.
S&F in repair of sheet metal enclosures double door for DBs SPN 12 way 240 Volt with 200 Amps rated Busbar including accessories therein and disposing off complete all as specified and directed.
S&F in repair Sheet metal enclosures for DBs SPN 8 way with 200Amps rated busbar including accessories therein and disposing off complete all as specified and directed.
S&F in repair of MCB SPN 63 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and as directed.
S&F in repair MCB SPN 40 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and directed.
S&F in repair MCB SP 6-32 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and directed.
S&F in repair MCB TPN 40-100 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and directed.
S&F in repair of Single pole and neutral (SPN) enclosure with a two pin and earth plug and socket complete with one single pole MCB 20Amps complete all as specified and directed.
S&F in repair of Triple pole (TP) and earth enclosure with a three pin and earth plug and socket complete with one tripple pole MCB 63 Amps complete all as specified and directed.
S&F of Exhaust Fan,steel body AC single phase ,230Volt of size 300 mm sweep with blades,and frame lovoures complete all as specified and as directed.
S&F Recess mounting type LED indoor luminaire powder coated, CRCA or powder coated aluminium panel 2' x 2' (Appx) system wattage 35 watt to 36 watt (cool white), minimum system lumen efficacy not less than 100 lumper per watt, CRI not less than80, colour temperature not less than 6000 K, power factor not less than 0.95, LED driver IP protection IP 20, powder coated housing with ashthetic bottom frame, suitable for any type of ceiling system including connection with PVC insulated copper conductor, including taking down, complete all as specified and directed.
S&F indoor decorative 20 Watt LED Light fitting four feet PVC batten housing LED batten type luminaire high efficiency electronic driver, (lumen output not less than 2000 lumen), power factor more than 0.9 colour temperature not less than 6000K, LED driver with PVC insulated copper conductor complete all as specified..
S&F of Lamp holder, insulated body, cord grip pattern SP 230 volt, complete all as specified and directed.
S&F LED light fitting 2 feet 10 watt 220 V AC decorative type with driver holder and including connecting up with three core flexible copper conductor cable of suitable size, in repair complete all as specified and directed by Engr-in-Charge.
S&F LED light fitting 1X9W/1X10W bulkhead aluminium die casted luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, in repair complete all as specified and directed.
S&F LED Bulb 7/9 Watt white Normal Holder type , in repair complete all as specifed and as directed by Engineer in Charge
S&F of wall mounted fan 400 mm 3 blade 1350 RPM swing off white wall fan complete all as specified and directed
S&F of LED flood light 100 Watt pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP 66 Protation 100 watt 230 V AC, 100 LPW, CRI 80, pf>0.90, in repair with driver and clamp etc complete all as specified and directed
S&F Building security LED street light fitting 30 Watt 6500K pf >.90 efficency 100lp/W 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp fixing of wall,pole,building with impact and corrosion resistant including thermal management in multiple optics including taking down complete with IP 65 protection complete all as specified and directed.
Street light bracket made out of 25/30/32 mm dia GI light grade tubing not less than .75 Mtr long bend to shape including pole clamps/fastners clips nails made out flat iron and nuts, bolts and washers etc complete all as specified and directed.
Taking out and kept in MES store yard Electric Water heater storage cap 25 Ltr steel body with Steel ineer tank and Heating Element up to 2 kw complete with safety valve thermostate NRV Connection piece etc complete all as specifie and directed.
Fixing only Electric Water heater storage cap 25 Ltr steel body with Steel ineer tank and Heating Element up to 2 kw complete with safety valve thermostate NRV Connection piece etc complete all as specifie and directed.
Supply laying, connecting and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, of size 50 sqmm 3.5 core laind in trenches or passing through pips/ ducts including taking down complete all as specified and directed by Engineer in charge
Excavation in trenches in any type of soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth, for foundation, laying of pipes and LT cable and getting out, , complete all as specified and directed by Engineer-in-Charge
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each in any type of soil , complete all as specified and directed by Engineer-in-Charge
Removing excavated spoil (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point , complete all as specified and directed by Engineer-in-Charge
Dry sand cushioning to under ground cable all as per clause 19.75 of SSR Part - I laid before and after laying of cable, complete all as specified and directed by engr-in-charge.
Sub class 'B' old size bricks well burnt as covering to under ground cables , laid dry, flat over the cables on sand cushioning with width equal to length of the brick as mechanical protection to cable complete all as specified and directed
Cutting of road (in hard/ dense soil ) for laying pipe line or repair to pipes of any size upto 0.5mtr. Depth and getting out incluiding forming bottom surface to required level and making good the road as per existing bitumens , concrete all as specified and directed.
S&F 80 mm dia GI tubing, light grade,for protection of cable passing across the road,under floor etc,complete all as specified and directed.
M&L in repair of VTPN Vertical three phase distribution board, VTPN, 8 way 440 volts having IP-54 isolated busbar assembly IK 09 Mechnical impact strength door earthing protection, double door with provision for fixing of MCCBs as incomer up to 125 Amps and MCBs as outgoing complete all as specified and as directed .
Supply and fix in repairs of MCCB 4P 63 Amps /415Volts ,having breaking capacity with complete accessories as per existing suitable size complete all as specified and as directed
S&F in repairs of MCCB 4P 100 Amps /415Volts ,having breaking capacity with Complete accessories as per existing suitable size complete all as specified and as directed
S&F in repairs of MCCB 4P 125 Amps /415Volts ,having breaking capacity with Complete accessories as per existing suitable size complete all as specified and as directed
Earthing complete with Galvanised steel earth plate electrode of size 60 cm x 60 cm x 3.15 mm thick as earth burried directly in ground (earth pit not less than 2.25 Meter deep below ground level) with top edge of the earth plate not less than 1.5mtr below ground level using GI earth lead wire 4.0 mm dia as earth continuity conductor connected to earth plate by means of copper thimbles, nuts, bolts, washers including jointing of earth electrode and earth wire by means of welding, all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and pit cover made of MS sheet 2 mm thick duly fixed to angle iron frame with hinges of appropriate size by welding and having locking arrangement, adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil , removing surplus excavated material all as required at site and as specified in EP No 3 of MES SSR Part-I (2009) directed by Engineer-in-charge including testing on completion.
Supply and fixing of Earth continuity conductor or main 4 mm Galvanised iron wire fixed to wall on batten or recess or chases including or drawn in conduit/pipe or fixed to poles or any other indicatedsituation for loop earthing etc. complete all as specified and directed
GI tube light grade of bore 40 mm with all fittings and fixed complete to walls and ceiling or laid in floor for cable crossing including cutting of bitumen roads/PCC and making good after laying of cable up to building height complete all as specified and directed
ANIKET TRADERS
MAHADEV ENTERPRISES
SARDALIA CONST CO
SHIVAE CONSTRUCTION
vijay builders
Bidder Name
vijay builders
MAHADEV ENTERPRISES
ANIKET TRADERS
SHIVAE CONSTRUCTION
SARDALIA CONST CO
RANBIR ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .