| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.2 CrAdmitted-Finance 880 1 SC ROAD BATOR HOWRAH 711104 | HOWRAH | HOWRAH | WEST BENGAL | 711104 | +0.00% | ₹1.2 Cr | L1 | Admitted-Finance |
| 2 | L1₹1.2 CrAdmitted-Finance | +0.00% | ₹1.2 Cr | L1 | Admitted-Finance |
| 3 | L1₹1.2 CrAdmitted-Finance B 35 CHANDAKA INDUSTRIAL ESTATE PATIA B 35 CHANDAKA INDUSTRIAL ESTATE PATIA INFOCITY SQUARE BHUABNESWAR ORISSA 751024 | KHORDHA | ODISHA | 751024 | +0.00% | ₹1.2 Cr | L1 | Admitted-Finance |
| 4 | L1₹1.2 CrAdmitted-Finance HOUSE NO 6 NARENDRA GARDEN PO JAGAMARA PS KHANDAGIRI DIST KHORDHA PIN 751030 | KHORDHA | KHORDHA | ODISHA | 751030 | +0.00% | ₹1.2 Cr | L1 | Admitted-Finance |
| 5 | L1₹1.2 CrAdmitted-Finance PLOT NO 594 2922 GADAMAHAVIR LANE GARRAGE CHACK BHUBANESWAR 751002 | KHORDHA | ODISHA | 751002 | +0.00% | ₹1.2 Cr | L1 | Admitted-Finance |
Tender Value
₹1.2 Cr
EMD Value
₹1.2 L
Closing Date
15 Apr 2026, 5:00 pmClosed
S.E. Electrical Circle (RandB) Bhubaneswar
S.E. Electrical Circle (RandB) Bhubaneswar, Nirman Soudha, Unit-V, 751001.
SITC of Aerosol based Fire Suppression System and Lift Pressurization System in DHH, Malkangiiri District During 2025-26
2026_EICCL_127736_1
Bid Identification No.S.E.E.C (RandB) 37/2025-26
National Competitive Bid
Electrical Works
180 days
Malkangiri
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹1.2 L
11 May 2026
31 Mar 2026
16 Apr 2026
31 Mar 2026
15 Apr 2026
31 Mar 2026
31 Mar 2026 - 8 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Aerosol Based Fire Extinguisher Supply & Installation 8 gm Portable Aerosol based Automatic Fire Shield (Coverage: 0.08 m3), EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction of Engineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x/Equivalent | |||||
| 2Supply & Installation of 20 gm Portable Aerosol based Automatic Fire Extinguisher (Coverage: 0.2 m3), EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction of Engineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x/Equivalent | |||||
| 3Supply & Installation of 30 gm Portable Aerosol based Automatic Fire Extinguisher (Coverage: 0.3 m3) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x/Equivalent | |||||
| 4Supply & Installation of 50 gm aerosol based Manual Fire Extinguisher (Duration:10-20 sec) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 5 years. Make-Pyrogen/Firepro/Stat-x/Equivalent | |||||
| 5SITC of 2 kg capacity Eco friendly stored pressure type filled with HFC 236(Clean agent fire extinguisher having zero ozone depletion potential) clean agent fire extinguisher s with safety seal,pressure gauge, controlable discharge mechanism helium leak detection tested and confirming to IS:15683 complete with initial charge as required. Make : Fireshield/Kanex/ Safex/ ceasefire/Flameklog | |||||
| 6Supply & Installation of 3.3 Kg Manual aerosol based Fire Extinguisher covering 150m3 for big fire (Throwable unit) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Firepro/Stat-x/Equivalent | |||||
| 7Supply and Installation of linear heat detection cable compatible with aerosol based fire extinguisher as per direction of Engineer-in-charge.Make-Make-Pyrogen/ Firepro/Stat-x | |||||
| 8Pressurization System for Lifts Supply, Installing, Testing and Commissioning of VANE AXIAL FANS as per specifications stated below. Fan shall be direct driven Vane axial fan , IP55, AMCA Certified (For Air and Sound Performance as well as FEG). The fan shall be equipped with mounting bracket, inlet guard (If required) & spring isolators for the installation of the fans. Motors shall be VFD Compatible suitable for 415+10% volts, 50 cycles, 3 phase AC supply. Fan static pressure shall be as indicated but actual fan static pressure to be checked by HVAC / MEP Vendor. Supply Fans shall be activated from fire signal from fire alarm system. Fan shall be with fire proof flexible connection at outlet. Motors shall be of minimum IE2 efficiency, class F insulation. Fan total efficiency should not be less than 72% and FEG should not be less than 85, noise level should not be more than 84 dB(A) @ 3m distance when measured in hemispherical reverberant room conditions. Sound attenutors of appropriate length shall be included in the cost to achieve the desired result.The differential pressure should be maintained as per NBC 2016. MAKE - SYSTEMAIR/ GREENHECK/ ELTA/Krugger/Nikotra 18600 cfm ,30 mm Static pressure for Lift well/Lift lobby | |||||
| 9Design, manufacture, supply, installation, testing and commissioning of the following cubicle type, wall mounted control panels including anchoring into the wall, wiring and earthing terminating into MPCB in each panel shall be provided by the electrical contractor. All outgoing shall be provided with Stop / Manual /Auto selector switch to facilitate operation through BMS. All starters shall be provided with potential free Contact for Connections to Building Automation System. Over-load relay, suitable for motor duty and able to withstand fault level of suitable KA rating. single phase preventer (Electronics type) as per the ratings given below. Terminal block for power distribution. Power Contactor. Phase indicating lights and indicating light for ON/OFF/TRIP status phase sequence relay shall also be provided. Time delay relay for delayed automatic restart of motor (0-180 sec). Integration with fire alarm detection system and fire damper for starting / stopping the fan (in case of fire) / Power supply for damper control panel. For on/off/remote and local operation, 3 pole single throw switch shall be provided in each panel to facilitate override of the automatic operation. All starters shall be provided with suitable potential free contract for connections to the Building Automation System. The number of control panels shall be as follows. Make (Switchgear) - ( MCCB : Make-Legrand-(DPX3)/Schneider-(CVS)/Siemens-(3VA) /ABB (Formula), MCB : Make-Legrand-(DX3)/Schneider-(Acti9)/Siemens-(betagard)/ ABB (SB200) Make of VFD-Siemens/Schneider/ABB 16/25/32/63A 4P MPCB with 5/10/15 HP Three phase VFD with bypass star delta/DOL starter with overload relay and single phase preventer . Each of these compartment shall contain indicating lamp with ON/ OFF/ TRIP status for fan sections/axial fans.The price is inclusive fire control relay module. | |||||
| 10Supply & Fixing of Air Distribution Duting fabricated with Class VI GI Sheet(180 GSM) Complete With Supports, dampers, guiding vanes, access doors, MS Angle, Fire inhibiting gaskets, Nuts, bolts and all oyher accessories in accordance with approved drawing and the Specification. (Make:- Jindal/ Sail/ Tata) 22 G (0.8 mm) | |||||
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.58 MB
DTCN.pdf
Tender Documents • 1.95 MB
BOQ_586800.xls
BOQ • 0.50 MB
Download all tender documents and submit your bid