Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC | L1 | Accepted-AOC SELECTED BEING LOWEST QUOTED RATE | |
| 2 | L2₹21.0 L+₹1.1 L (5.27%)Rejected-AOC | L2 | Rejected-AOC NOT SELECTED BEING HIGHER QUOTED RATE | |
| 3 | L3₹21.6 L+₹1.6 L (7.99%)Rejected-AOC | L3 | Rejected-AOC NOT SELECTED BEING HIGHER QUOTED RATE | |
| 4 | L4₹21.6 L+₹1.6 L (8.13%)Rejected-AOC | L4 | Rejected-AOC NOT SELECTED BEING HIGHER QUOTED RATE | |
| 5 | L5₹21.8 L+₹1.8 L (9.10%)Rejected-AOC | L5 | Rejected-AOC NOT SELECTED BEING HIGHER QUOTED RATE |
Tender Value
₹28.9 L
EMD Value
₹57,800
Closing Date
18 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DIST-BURDWAN, WEST BENGAL, PIN-713420
All as per BOQ
2023_MES_624553_1
8500-033/E8
Open Tender
Civil Works
Works
180 days
PANAGARH
Class D and Category a(i) (Building)
6 documents required · 6 mandatory
₹500
GE PANAGARH
₹57,800
Yes
10 Jan 2024
21 Oct 2023
20 Nov 2023
21 Oct 2023
18 Nov 2023
4 Nov 2023
Amount
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stone work and precast concrete articles and removing rubbish off the premises complete all as specified and directed.
M&L for fly ash brick straight or curved on plan exc 6 mtr mean redious built in CM (1:6) complete all as specified and directed. Make : ACC/Lafarge/L&T/Shyam Steel Pvt Ltd
Taking down cement plaster, any description on brick or stone walls and ceiling, chajja, landing etc including racking of joints hacking for key scrubbing down with water etc and removing rubbish off the premises complete all as specified and directed.
M&L for 15mm thick rendering in CM (1:6) on internal surfaces of brick masonry wall finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering in CM (1:4) mixed with water proofing compound on external surfaces of brick masonry wall finished even and fair (water proofing item to be paid separately) complete all as specified and directed
Supply only Liquid water proofing compound complete all as specified and directed. (Makes : Pidilite Industries/ Impermo/Snowcem India Ltd/Sika)
M&L for preparation of new plastered surfaces of wall and applying two coat oil bound distemper over a coat of alkali resistant primer complete all as specified and directed.
M&L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. (Make: M/s Apex Ultima of Asian/ Weather Coat all guard of Berger/Xtra Tough of Shalimar)
M&L for completely removal of existing surface and applying two coats of Oil bound distemper on wall surface over a coat of alkali resistant primer complete all as specified and directed.
M&L for complete removal of existing surface preparation of old plastered surface of wall for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed. (Make: M/s Apex Ultima of Asian/ Weather Coat all guard of Berger/Xtra Tough of Shalimar).
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed
Fixing only Pre-painted galvatume aluminum @150 GSM zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, filling holes if any with with mastic tape/M-seal all as specified and directed by Engr-in-Charge.
M&L for Pre-painted galvatume aluminum zinc coating @150 GSM GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
S&F Pre-painted galvalume aluminum zinc coating @150 GSM GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in Ridges fixed with self tapping screws complete all as specified and directed
M&L for flat iron fillets (for securing wire mesh, CGI Sheets etc), Hand rails, half round or other steel section including embedding in concrete and screwing etc, wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed
Taking down chowkhats or frame n.exc 1.5 Sqm each with shutter(s) (without taking off shutters from the frame), complete all as specified and directed
Taking down chowkhats or frame exceeding 1.5 Sqm but not exceeding 4 Sqm each with shutter(s) (without taking off shutters from the frame) complete all as specified and directed
M&L for factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50X125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made
S&F Factory made single extruded WPC (Wood Polymer Composite) solid decorative panelled decorative flush door shutter one side plain on other side of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately)
All as per item No 19.00 but wire gauzed i.e. panel will be of wire gauze in lieu of PVC sheet panel. The wire gauze shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be welded to M.S. tubes. The wire gauge shall be stretched to tighten firmly complete all as specified and directed
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge complete all as specified and directed
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charges, anodised etc complete all as specified
M&L for preparation of newly wooden surfaces of any description not otherwise described over 10 cm girth or width and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S&F 4mm thick sheet glass ordinary quality with oil putty in square n.exc 0.5m in each pane complete all as specified and directed
S&F 100 mm long Butt hinges, extruded aluminium alloy with alvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and directed
S&F for 150 mm aluminium handles, cast type, anodised complete all as specified and directed
S&F for 150 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed
S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple ( bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast-aluminium alloy complete all as specified and directed
S&F mild steel flat iron as in hold fast clamps small articles conforming to FE 290 GDE-E-165 complete all as specified and directed
M&L for PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) as in bed blocks for hold fast including necessary formwork, kerb stones etc complete all as specified and directed
S&F floor door stopper of brass body 150 mm long and tongue with rubber shoes complete all as specified and directed
Dismantling of wall or ceiling boards of any thickness including cover fillets complete all as specified and directed
S&F 605mm x 605mm anodised aluminium snap grid frame work for false ceiling with all necessary aluminum angle & Tee arrangement with and incl fixing cleats screws etc complete all as specified and directed
S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long complete all as specified and directed
S&F 6mm thick (non asbestos fiber) Designer building boards fixed in aluminium frame work in ceiling flat or sloping with screw complete all as specified and directed
Demolition of cement concrete (un-reinforced) n.exc 15 cm thickness of any description and in any position not otherwise specifically provided and removing rubbish off the premises complete all as specified and directed
M&L for 75mm thick Cement concrete type D-2, 1:4:8 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed
M&L for 40mm thick PCC 1:2:4 type B-1 (using 20mm graded coarse aggregate) in flooring complete all as specified and directed
M&L for joint free non skid coloured ceramic tiles 7 to 8mm thick (square or rectangular) area of each tile exceeding 0.18 Sqm but not exc 0.38 sqm in floors set and jointed in neat cement slurry and pointed in coloured cement to match the shade using coloured tiles laid over and including screed bed or bedding layer of 15mm thick in CM 1:6 including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises all as specified and directed. (Note : Design, shade and pattern of fixing of tiles shall be as directed by Engr-in-charge)
All as per item No 40.00 above but as in skirtings/ dado over 10mm thick in CM (1:3) complete all as specified and directed (Note : Design, shade and pattern of fixing of tiles shall be as directed by Engr-in-charge)
M&L for 75 mm thick PCC type C-1 1:3:6 (using 20 mm graded stone aggregate) finishing the as in Plinth protection surfaces even and smooth without using extra cement complete all as specified and directed
M&L for Green Marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar 10mm thick (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of following types complete all as specified and directed
M&L for broken stone hardcore of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface complete all as specified and directed
Dismantling wrought Iron or mild steel work of any description not otherwise provided for wind tie complete all as specified and directed
S&F roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. Fe-410-W (Gde-E-250) quality-A complete all as specified and directed
M&L for Mild steel TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer on newly steel surfaces of any description over 10cm in width or girth not otherwise described incl preparation of surfaces and complete all as specified and directed
M&L for repairs to crack portion with Jacketing technique, taking down the existing plaster up to brick wall surface of min 200mm wide, cleaning the loose particles on surface of brick work along the length of the crack and filling the gap/crack area with PCC 1:1.5:3 type A0 using 12.5mm aggregate up to brick surface and inserting the welded mesh of size 25X25X2mm dia along the crack on both sides of the wall surface fixed with, drilling holes 10mm dia on either side of the crack by means of drilling mechane trouoght the full width of the wall @ 25cm c/c and insert 8/10mm dia rod in the drilled holes, welded with horizonal rod to with hold the welded mesh and applying grit plaster 1:1:2 using 4mm and down aggregate finished even and smooth with out using extra cement. Note: Reinforcement and welded mesh will be measured and paid separately.
M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) incl necessary form wok complete all as specified and directed by Engineer-in-Charge
S&F Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
Demolition of concrete (unreinforced) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) and removal of rubbish off the site complete all as specified and directed
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for machine pressed pre-polished coloured precast concrete interlocking paver block any shape and size with mixture of grey cement and pigment confirming to IS 15658-2006 of 60 mm thickness M-35 Grade complete all as specified and directed
M&L for 200 mm thick Kankar or laterite, (mix of fly ash, clinker and stone dust in proprtion of 1:3:6 (ie 10% fly ash, 30% clinker and 60% stone dust) spread, rolled and consolidated to gradient and camber required complete all as specified and directed
M&L for excavating over areas, n.exc 1.5 m deep and getting out in soft loose soil complete all as specified and directed
M&L for Cement Concrete, 1:2:4, type B1 (using 20mm graded stone aggregate) as in bed block, coping ,lintel upto 1.50 m span, cills, kerbs etc complete all as specified and directed
S&F for Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
M&L for Vitrified Ceramic tiles 10 mm thick light shade(square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including over screed bed or bedding layer of mortar 15 mm thick laying floor finished in CM (1:6) complete all as specified and directed. (Note : Design, shade and pattern of fixing of tiles shall be as directed by Engr-in-charge)
All as per item No 61.00 but light shade tiles on vertical surface set and jointed in neat cement slurry and including backing coat rendering 10 mm thick in CM (1:3) complete all as specified and directed
Rounding to edges of stone slabs exposed edge, such as in steps, cooking platform and other similar situation complete all as specified and directed
S&F glass door for squash court comprising of 12 mm thick tempered glass and complete with all extruded stainless hardware including floor mounted door closer with all fittings complete all as specified and directed
M&L for providing cement concrete type B0 1:2:4 (using 12.5mm graded stone aggregate) as in coping to chajja tops and all other similar works complete all as specified and directed.
M&L for complete removal/scrapping of existing treatment of plastered surfaces and applying two coat of plastic emulsion paint over a coat of primer as per manufacturer's instructions, complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of plastic emulsion paint over a coat of primer and coat of 1 mm thick wall care putty complete all as specified and directed.
M&L for preparation of old steel surfaces of any description exc 10cm width or girth and applying one coat of 1st quality synthetic enamel paint complete all as specified and as directed.
M&L for preparation of old wooden surfaces of any description over 10cm width or girth and applying one coat of 1st quality synthetic enamel paint complete all as specified and as directed.
M&L for writing letters or figures (block, Roman, Italic or indian) n.exc 30 cm complete all as specified and as directed.
S&F for providing and fixing stainless steel (Grade-304) railing & curtain rods made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed.
M&L for cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) in surface channels and drains complete all as specified and directed.
M&L for extra for forming 40 cm inner girth fair finished drains or channels i.e. exc 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/ stopped ends etc complete all as specified and directed.
M&L for 25 mm thick pre-polished coloured chequered cement concrete tiles of approved size (30cmx30cmx25mm), set, jointed and pointed using with grey cement and pigment in floors, paving etc. including the setting and jointing in neat cement paste or slurry 0.3kg/Sqm over 20 mm thick screed bed or bedding layer in cement mortar (1:4) complete as per manufacturer instructions and direction.
E/M PORTION Taking down carefully aluminium conductor point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling rose, pendants, regulators sockets etc and removing (except those to be reused shall be kept in safe custody at the site) and making good disturbed surfaces of walls, floors etc to match with the existing complete all as specified and directed.
M&L for point wiring for light point/ fan point, one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectional area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
All as per item No 77.00 above but One 3 pin 5 Amps socket out let points on independent board complete all as specified and as directed
All as per item No 77.00 above but 5 Amp socket on same board with other switches complete all as specified and as directed.
M&L for wiring for socket out let on independent Boards controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FR cable earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
S&F switch piano flush type, single pole, 5/6 Amps, one way complete all as specified and directed.
S&F switch socket combination 2 in 1 multipurpose 5 pin, (6 Amps) flush type controlled by one switch complete all as specified and directed.
S&F socket outlets 2 in 1, 5 pin, 5/6 Amps flush type230/240 V complete all as specified and as directed.
S&F switch socket combination 5 in 1, 6 pin, (5/16 Amps ) flush type controlled by one switch complete all as specified and directed.
S&F ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified and directed.
S&F stepped type electronic fan regulator flush type 240 Volts ISI marked complete all as specified and directed.
S&F lamp holder, PVC/polycarbomate type with back plate straight of angle suitable for LED lamp complete all as specified and directed.
S&F submain two single core 4 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable PVC insulated unsheathed 1100 volts grade drawing in and suitable size PVC conduit (ISI Marked) concealed including 4 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 volts grade earth wire complete all as specified and directed. (Note: (i) Three runs cable and PVC conduit will be measured as a single unit. (ii) Quoted rate shall be included for necessary chasing, cutting and making good as per existing specification)
S&F wall LED security light fittings 35 watt, 230 volts, minimum lumn output 100 lumen/watt, made up of pressure dia cast housing with prismatic polycarbonate difuser and industrial LED with secondary optic and IP-65/66 including necessary connection complete with all accessories including connected with 3 core copper cable of suitable 1.5 sqmm size complete allas specified and directed.
S&F LED light fitting 1 x 20 watt box type with same make LED tube rod side connection AC decorative box type 4' long with driver, holder including LED tube connecting up with complete all accessories and connection from ceiling rose with twin core twisted flexible copper conductor cable with suitable size and earthing complete all as specified and directed.
S&F recessed mounted 2' x 2' LED lminaire 36 watt for grid ceiling minimum lumen output 100 lumen/watt pre-treated CRCA frame powder coated with difused profiled including necessary connection complete all as specified and directed.
S&F epoxy powder coated sheet metal enclosure for TPN DBs, 4 ways, double with mounting fitted with bus bar, DIN channel, neutral link and incoming contact, IP-43 complete all as specified and directed. Make: ABB/L&T/legrand/Hager/Schneider
S&F epoxy powder coated sheet metal enclosure for DBs, single door, Single pole and neutral, 8 ways, with mounting fitted with 200 Amps rated bus bar, DIN channel , neutral link and incoming contact complete all as specified and directed. Make: ABB/L&T/legrand/Hager/Schneider
S&F MCB TPN 40-100 Amps, 'C' series 10 KA, 415 Volts and to be housed in DBs complete including necessary connection complete all as specified and directed. Make: ABB/L&T/legrand/Hager/Schneider
S&F MCB SPN 6-32 Amps, 'C' series 10KA, 240 Volts and to be housed in DBs complete including necessary connection complete all as specified and directed. Make: ABB/L&T/legrand/Hager/Schneider
S&F MCB SP 6-32 Amps, 'C' series 10KA, 240 Volts and to be housed in DBs complete including necessary connection complete all as specified and directed. Make: ABB/L&T/legrand/Hager/Schneider
M&L for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 15 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion.
S&F D clamp of strip size 25x6 mm with suitable washer, nuts, bolts in any shape or size as indicated or directed including making hook for hanging ceiling fan and inclusive of one primer coat ,one under coat, one finish coat of paint complete for hanging of ceiling fan all as specified and as directed.
Taking down old unserviceable ceiling fan carefully from ceiling and deposite to E/M store yard complete all as specified and directed.
S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Supply, laying, connecting, testing and commissioning of LT under ground cable XLPE insulated, armored heavy duty electric cable with aluminium conductor , 1100 volts grade , cross sectional area 35 sqmm 3½ core complete all as specified and directed.Make: Havells/Polycab/KEI. Note:- (i) Excavation, sand cushioning, brick will be measured and paid separately.
M&L for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and leveling complete all as specified and directed. Note :- Punned thickness 18 cm shall only be considered for payment
Supply and lay in trenches fly ash bricks, for cable protection all as specified and directed by the Engr-in-Charge.
S&F Pipes galvanized, 50mm bore “light grade”, supplied and laid complete including necessary fittings such as tees, bends, elbows, sockets, reducers etc as per site requirement or specified complete all as specified and directed.
M&L for wiring for socket outlet 3 pin, 15 amps on independent Boards controlled by one, one way switch using 4.0 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 4.0 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLSH cable earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
S&F LED light fitting 1x9W/1x10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable complete all as specified and directed.
S&F 10 W LED light fitting mirror type 2', 220 volt AC lighting fixture with complete all accessories and connection from ceiling rose with twin core twisted flexible copper conductor cable with suitable size and earthing complete, complete all as specified and directed
S&F LED luminaire Colour (CW) 600x600mm 40 watt 220 volt AC recessed type with high efficency PMMA diffuser soft glare free light complete with driver, holder & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size all as specified and directed by Engr-in-charge.
S&F exhaust ventilation fan with louvers of sweep 450mm,230 volts, with blade and frame and loures steel body complete all as directed by Engr-in-Charge.
S&F in repairs epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 12 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and directed Make: ABB/L&T/legrand/Hager/Schneider
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmmx2core laying properly in treanche all as directed by Engr-in-charge Make: Havells/Polycab/KEI.
M&L for earthing complete using copper plate 60cmx60cmx3.15mm electrode and burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate with 20x3mm copper strip as earh lead plate at one end and connected to equipments at another end, copper strip encased in and including 25 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
ANSH CONSTRUCTION
MS ROYAL CONSTRUCTION INDEX NO 158 2010 BKP
S.P.S. SUPPLIERS
SARASWATI ENTERPRISE (INDEX NO CEEC D-81)
subash chander bahl
SANJAY KUMAR SUPAN
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .