| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.9 LAccepted-AOC 15 CP COLONY MORAR GWALIOR MP 474 006 | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹14.9 L+₹39,718 (2.74%)Rejected-Finance 15 15 KHERIYA BHAN PURANI CHAWANI GWALIOR GWALIOR GWALIOR MADHYA PRADESH 474010 | GWALIOR | MADHYA PRADESH | 474010 | L2 | Rejected-Finance Not being lowest tender | |
| 3 | L3₹15.0 L+₹47,566 (3.28%)Rejected-Finance | L3 | Rejected-Finance Not being lowest tender | |
| 4 | L4₹15.3 L+₹82,588 (5.69%)Rejected-Finance | L4 | Rejected-Finance Not being lowest tender | |
| 5 | L5₹18.4 L+₹3.9 L (26.6%)Rejected-Finance 227 NEW GANESH VIHAR ADARSH MILL ROAD GHOSIPURA LASHKAR GWALIOR 474012 M P | GWALIOR | MADHYA PRADESH | 474012 | L5 | Rejected-Finance Not being lowest tender |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
12 Jun 2023, 6:00 pmClosed
GE (AF) ADM AREA GWALIOR
GE (AF) ADM AREA GWALIOR
REPAIR REPLACEMENT OF LT PANEL BOARDS AND ALLIED WORKS AT AF STN GWALIOR
2023_MES_594819_1
8314/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
AF STN GWALIOR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (AF) ADM AREA GWALIOR
₹40,000
Yes
30 Jun 2023
12 May 2023
20 Jun 2023
12 May 2023
12 Jun 2023
29 May 2023
Amount
~Ditto~ all as per srl Item No 2 above but for Ammeter of upto (0- 800) amps complete all as specified and directed.
M&L in replacement of current transformers of ratio 100/5 to 400/5 Amps in existing LT feeder pillar panel and making connections of secondary terminals to ammeter with using 1.5 Sqmm PVC insulated and sheathed copper conductor cable including, testing and commissioning complete all as specified and directed.
~Ditto~ all as per srl Item No 4 above but for current transformers of 500/5 to 800/5 amps ratio complete all as specified and directed.
M&L in replacement of indication lamps LED type with showing red, yellow and green colours of 22.5mm dia fixed to monitor on LT panel board suitable for 240 Volts AC supply and making connections with using 1.5 Sqmm PVC insulated and sheathed copper conductor cable complete all as specified and directed.
Dismantling, taking out of unserviceable bus bar of any size and capacity in any position for re-use from the dismantled/taken from feeder pillar box/panel board all as directed.
Dismantling, taking out/removing unserviceable fittings/fixtures/ accessories like MCCB/change over switch/switch fuses unit etc. of any description & in any position from feeder pillar box/panel board all as directed.
Fixing only including necessary connection and commissioning of the following fittings / fixtures/accessories in the existing or newly fabricated panel board/feeder pillar box all as specified and directed
Aluminium bus bars of any shape and size .
Fixing only MCCB/change over switch/switch fuses unit etc of any description, and current rating upto 400 Amps. (Note : Old serviceable retrieved / taken out / removed fittings etc. from the existing /taken down feeder pillar box / panel board shall be re-used in the work).
Supply and Fixing new Aluminium bus bars of size 25x4mm and 400amps of any shape and size as directed.
S&F in replacement of Porcelain Bus bar insulator in existing LT feeder pillar box including nuts, bolts and washers complete all as specified and directed.
Taking down MS door of LT feeder pillar boxes with complete fitting/ fixtures and refixing the same, mild steel sliding door assembly 200 mm size clip & bolt type, stove enameled black, with bright bolt not less than 12mm dia with and including welding the sliding bolt & staple plate including nut, bolts and washers complete all as specified and directed
Supply and fixing in replacement MS Hinge plate in existing feeder pillar boxes/ panel boards with necessary spot welding etc including making necessary adjustment for free and smooth movement of panel and locking arrangements complete all as specified and directed.
Supply and fixing in replacement 2 mm thick CRCA MS Sheet duly febricated in existing panel, required shape and size with and all jointing material such as nuts bolts or washer and welding etc. complete all as specified and directed.
NOTE FOR ITEM NO 12, 13 & 14 :- (i). The panel board repaired shall be made totally enclosed, weather proof, wermin proof for installing incoming / outgoing MCCB / Switch fuses/ cable etc. complete all as directed (ii) The rates quoted by the contractor are deemed to be included necessary cutting, welding, leveling and jointing etc. as directed to match & accommodate with the existing feeder pillar box / panel board . (iii) The replaced portion shall be painted with two coat of synthetic enameled paint over a coat of red oxide primer.
Preparation of the old decorated existing external and internal steel surfaces of feeder pillar boxes/panels/ boards of any description and in any position including removal of disintegrated & deteriorated paint either by hand scrapping or by blow lamps, applying necessary filler coat and stopping as required and applying two coats of synthetic enameled paint (grey in color) with using spray machine on old prepared surfaces complete all as specified and directed .
Excavation in trenches in soft/loose soil not exceeding 1.5 m deep and not exceeding 1.5 mtr wide and getting out including forming bottom surface to required levels/gradients/slopes for foundations/laying of cable etc. including taking out existing cable protection brick cover etc.complete all as specified and directed
Returning, filling in, including spreading leveling, watering and well ramming the excavated soil in layers not exceeding 25 cm thick complete all as specified and directed
Removal of surplus excavated soil to a distance not exceeding 50 Mtr distance and depositing as directed at a level not exceeding 1.5 mtr above starting point complete all as specified and directed
M & L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed. Note: Punned thickness shall be measured and paid.
Laying only servicable Sub Class `B’ bricks, old size, kiln burnt, laid with axis of brick perpendicular to the axis of the cable, for protection of cable all as specified and directed. Note:- old brick shall be used retrived from intem No. 16 above.
Supplying & Laying Sub Class `B’ bricks, old size, kiln burnt, laid with axis of brick perpendicular to the axis of the cable, for protection of cable all as specified and directed.
Disconnecting, taking out and removing old existing unserviceable underground, LT cable of any description and in any position complete including taking down unserviceable protection pipe, earth work to take out the loop where required etc, stacking the cables properly for reuse, include cutting out the defective portion of cables and its removal from site all as specified and directed by the Engineer-in-Charge for the following sizes from ducts/ trenches / poles /pipes etc :-
LT aluminium conductor cable of size upto 50 Sqmm, 3 ½ core
LT aluminium conductor cable of size upto 70 Sqmm, 3 ½ core
LT aluminium conductor cable of size over 95 Sqmm, 3 ½ core
LT aluminium conductor cable of size over 120 Sqmm , 3 ½ core.
LT aluminium conductor cable of size over 185 Sqmm, 3 ½ core
LT aluminium conductor cable of size over 240 Sqmm, 3 ½ core
Laying, jointing and testing XLPE / PVC LT Cable PVC insulated, armoured, heavy duty electric cable with aluminum conductor 1100 volts grade of any description and any make laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed by the Engineer-in-charge for the following sizes :- NOTE- Old cable shall be re-used obtained from item No 22 above ).
LT aluminium conductor cable of size upto 50 Sqmm, 3 ½ core
LT aluminium conductor cable of size upto 70 Sqmm, 3 ½ core
LT aluminium conductor cable of size over 95 Sqmm, 3 ½ core
LT aluminium conductor cable of size over 120 Sqmm , 3 ½ core.
LT aluminium conductor cable of size over 185 Sqmm, 3 ½ core
LT aluminium conductor cable of size over 240 Sqmm, 3 ½ core
M&L for surface excavation around the poles/feeder pillar boxes/ Panels/ sub stations not exceeding 15 cm depth including cleaning the bushes and vegetation and leveling incl removal of surplus soil in to a distance n.exc. 50m complete all as specified and directed.
Supply, fabrication and fixing mild steel structural steel such as cross arms, bracing, supports, clamps and back plate fabricated from structural steel sections including nuts & bolts, washers of any description on LT over head line poles/ street light poles complete all as specified & directed.
Disconnecting existing LT over heated or burnt cable terminal at existing panel/ board/feeder pillar box etc., cutting out over heated / burnt / unserviceable portion of cable, stretching of cable end of required length from available rings etc. and fixing and connecting the cable in position properly by providing suitable aluminium lugs and GI nuts, bolts & washers etc. including neccessary excavation and earth work for following size of cable complete all as specified a
25 Sqmm to 95 Sqmm cable of any core
120 Sqmm to 185 Sqmm cable of any core
240 Sqmm to 400 Sqmm cable of any core
Disconnecting & taking down old existing unserviceable MCCB of any description and in any position complete all as specified and directed.
Supply, fixing, testing and commissioning in replacement MCCB, 630 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 35/36 KA with thermal setting 70% to 100% adjustable setting complete all as specified and directed.
Supply, fixing, testing and commissioning in replacement MCCB, 400 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 35/36 KA with adjustable load setting complete all as specified and directed.
Supply, fixing, testing and commissioning in replacement MCCB, 315 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 35/36 KA with adjustable load setting complete all as specified and directed.
Supply, fixing, testing and commissioning in replacement MCCB, 250 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 35/36 KA with adjustable load setting complete all as specified and directed.
Supply, fixing, testing and commissioning in replacement MCCB, 200 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 35/36 KA with adjustable load setting complete all as specified and directed.
Supply, fixing, testing and commissioning in replacement MCCB, 160 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 35/36 KA with adjustable load setting complete all as specified and directed.
Supply, fixing, testing and commissioning in replacement MCCB, 125 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 16 KA with adjustable load setting complete all as specified and directed.
Supply, fixing, testing and commissioning in replacement MCCB, 100 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 16 KA with adjustable load setting complete all as specified and directed.
Disconnecting / Dismantling Taking out old Spreader Terminals and Supply & Fixing new Spreader MCCB Terminals Current Rating 75/100/125 Amps all as specified and direcetd.
Disconnecting / Dismantling Taking out old Spreader Terminals and Supply & Fixing new Spreader MCCB Terminals Current Rating 150/175/200/250 Amps all as specified and direcetd.
Disconnecting / Dismantling Taking out old Spreader Terminals and Supply & Fixing new Spreader MCCB Terminals Current Rating 500/630/700/800 all as specified and direcetd.
Material and labour for earthing complete with Galvanised steel earth plate electrode 600mm X 600mm X 6mm thick buried directly in ground vertically earth pit not less than 2.25 meter deep below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI earth strip of size 25x4 mm as earthing lead by means of bolts, nuts and washers all as shown in electrical plate No 5 of MES Scedule part I (1991) with conected to eath test point including excavation and earthwork adequate quantity of charcoal dust and commen salt. PCC (1: 3 : 6) type C-1 chamber and for earth pit with 40x40x6mm mild steel angle iron frame for cover. precast RCC cover 40mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia round bars both ways with MS handle 12 mm dia. PGI funnel and wire mesh 20 mm dia GI pipe light grade for watering and 40mm dia light earth lead protection pipe. complete all as specified and directed. Note: Earth strip and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth strip/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of BOQ
Supplying and fixing earth continuity conductor or main earthing lead 32mm x 6mm, GI strip/earth lead, laid in pipe/fixed on walls or any other position including jointing by tinned copper/brass nuts, bolts and washers and saddling, welding at every joint complete all as specified & directed.
Disconnecting & taking out non functional ACB of any description and any make of rating 11 KV, 400 Amps to 1000 Amps dismantling/opening of the ACB for servicing/over hauling taking out and removing unserviceable/defective parts including cleaning and servicing greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the ACB after over hauling /servicing and its testing complete all as specified and directed (Note: - The quoted rates of the contractor includes for replacment of unserviceable parts with new parts. The new replaced parts shall be measured and paid for separately under appropriate item of Sch 'A' as supply only).
Supply only following spare parts for 11 KV ACB 400 to 1000 Amps capacity conforming to the respective cat part given as under : (Note (i) fixing and testing element of following item is deemed to be included under sch 'a' here-in-before(ii) Quantity of under mentioned items is tentative and contractor shall have no claim on account of variation of quantity or non execution of any of the item)
Supply only Arc Chutes for LT air circuit breakers
Supply only Arcing Contacts (Set of 1 No. Fixed 1No. Moving ) for LT ACB
Supply only Vertical Terminal Adapter for AH/AHA Fixed type ACB of 630/800 amps ACB
Supply only Auxiliary Isolating contacts Blocks Assembly (set of one contact block on ACB side & two blocks on cradele side for 630/800 Amp ACB
Supply only of Single Phase Resin Cast CTS for " AA/AHA" ACB for Thermal release for LT air circuit breakers of 630/800 Amp.
Supply only of Auxiliary Isolating Contact Assembly (Set of one contact block on ACB side & two blocks on cradle side)for LT air circuit breakers .
Supply only of Auxiliary Isolating Contact Assembly (Set of one contact block on ACB side & four blocks on cradle side)for LT air circuit breakers.
Supply onlyt of Main Isolating Contacts (Jaw Contacts) for LT air circuit breakers of
Supply only of Lower terminals with fitting plates .
Supply only of Main Fixed Contacts (Upper Terminals) for LT air circuit breakers of
Disconnectiong / Dismantling and Taking Out Old Earthing strip any type and any size from point of equipment, making the strip straight , removing all bends . Removal of deshaped portion and making the strip straight and in proper shap , Relaying the same in ground, on floor, wall etc with proper saddling/ Clampning and connecting with equipment and with necessary welding , Nut-bolts washers (Tinned copper) at all joints all as specified and directed.
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed.
Demolition/Dismantling of existing PCC platform of Transformer Sub Station of any capacity and M& L for PCC 1:3:6 type C1 using 20 mm graded stone aggregate, repairing the cable duct after disconnecting the LT/HT cable from transformer to LT panel and relaying the same after repair of duct and laying the existing GI plate for covering of cable tray complete all as specified dircetd.
AUTOMATION AND SWITCHGEAR PANELS
Achal Construction
M/s Sagar Construction
M/s KKPARASHAR
Kumar Sales Corporation
m/s anil traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .