Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.3 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹40.4 L+₹2.2 L (5.77%)Rejected-Finance 270 ADARSH NAGAR ROORKEE HARIDWAR 247667 | HARIDWAR | UTTARAKHAND | 247667 | L2 | Rejected-Finance Due to not lowest bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
31 Jan 2024, 6:00 pmClosed
GE (N) BIKANER
GE (N) BIKANER RAJASTHAN
REPAIR REPLACEMENT AND IMPROVEMENT TO WATER SUPPLY INSTALLATION UNDER GE N BIKANER
2024_MES_635797_1
GE (N) BKN-TOKEN/77/2023-24
Open Tender
Miscellaneous Works
Item Rate
335 days
GE (N) BIKANER
As per tender documents
6 documents required · 6 mandatory
₹500
GE (N) BIKANER
₹90,000
Yes
20 Mar 2024
4 Jan 2024
8 Feb 2024
4 Jan 2024
31 Jan 2024
19 Jan 2024
Amount
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size n. exc 1.5 Sqm each complete all as specified and as directed by Engineer-in-Charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size exc 1.5 Sqm but not exc 4.0 Sqm each complete all as specified and as directed by Engineer-in-Charge.
Taking down shutters of any description n exc 1.00 Sqm each complete all as specified and as directed by Engineer-in-Charge.
Taking down shutters of any description, area exc 1.00 sqm and n.exc 2.00 sqm each complete all as specified and as directed by Engineer-in-Charge.
S&F 1.25 mm thick Pressed steel frames of size 105mm x 60mm for single doors including necessary fixing lugs, hinges, lock strike plate, complete all as specified and as directed by Engineer-in-Charge.
S&F 1.25 mm thick Pressed steel frames of size 125mm x 60mm for single doors including necessary fixing lugs, hinges, lock strike plate, complete all as specified and as directed by Engineer-in-Charge.
M&L PCC 1:2:4 type B-1 using 12.5 mm graded stone aggregate as in filling in chowkats, hold fast block etc. complete all as specified and as directed by Engineer-in-Charge.
S&F Second class hard wood plain, framed, panelled shutters 30mm thick, (any number of panels) with panels of timber flat on both sides (feather edged) or of veneered partcile board medium density wood particle board with commercial faces venners supplied and fixed to chowkats complete all as specified and as directed by Engineer-in-Charge.
S&F Second class hard wood, glazed and skelleton shutters 30mm thick, open rebated and prepared to receive glass, gauze, etc without sash bar, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing gauze etc, size of members as directed supplied and fixed to chowkats complete all as specified and as directed by Engineer-in-Charge.
S & F Stainless steel wire mesh 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed by Engineer-in-Charge.
S & F in repair Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed by Engineer-in-Charge.
Preparation of New or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer complete all as specified and as directed by Engineer-in-Charge.
S&F 100 mm long,Butt hinges, medium weight, cold rolled mild steel,complete all as specified and as directed by Engineer-in-Charge.
S & F 150 mm long Mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified and as directed by Engineer-in-Charge.
S & F 150 mm long Mild steel pressed handles, oval type, stove enamelled black complete all as specified and as directed by Engineer-in-Charge.
S & F 250mm long Mild steel sliding door bolts,plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and as directed by Engineer-in-Charge.
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with head moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rain & bottom rail paneling of plain gap insert for top rail & bottom rail paneling of plain color PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement all as specified.
S&F Solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S. square tube suppling & fixing in opening all as specified and as directed.
S&F 100mm long butt hinges, extruded alu minium alloy with galvanised mild steel hinge pin, anodised and fixed, complete all as specified and as directed by Engineer-in-Charge.
S&F 150mm long Aluminium anodised,barrel tower bolts of ex truded section and fixed complete all as specified and directed
S&F 150mm long Aluminium handles, cast type,anodised complete all as specified and as directed by Engineer-in-Charge.
S&F aluminium frame powder coated of any colour as approved (Thickness of powder coating not less than 50 micron) for doors, windows, ventilators, partitions, with one or more rebates including joining cleat for fixing etc. complete all as specified & as directed. Note : Frame to walls etc shall be fixed with PVC rawl plugs and steel screws of length not less than 75mm at places as directed. Quoted rate shall deemed to include the same.
S&F aluminium doors, window and ventilator shutters, powder coated of any colour as approved (Thickness of powder coating not less than 50 micron), side hung type without sash bars, aluminium sections including necessary joining cleats, glazing clips, powder coated aluminium snap beading, screws, with aluminium grills complete all as specified & as directed. Note : Glass and rubber neoprene packing / rubber gasket shall be measured and paid for separately as “Supply only” under respective item of this Schedule.
S& F Neoprene/ EPDM rubber gasket for aluminiuim doors shutter and window complete all as specified and as directed by Engineer-in-Charge.
S&F 4.8mm thick sheet glass, ordinary quality and glazing with oil putty/rubber gasket in square of any thickness in each pane for metal frames complete all as specified and as directed by Engineer-in-Charge.
S & F in repairs of floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor with overall length of vover plate 140 mm complete all as specified and as directed by Engineer-in-Charge.
S&F in repair curtain rdrapery od 20 mm dia, mild steel, chromium plated, fancy type with fixing brackets and knobs at both ends as per site requirement complete all as directed by Engineer-in-Charge. Note:- The cost of brackets and knobs is deemed to be included in the quoted rate. Nothing extra shall be paid on this account.
S&F in repair, stainless steel tubular towel rail 20 mm dia D type, 600 mm long complete all as specified and as directed by Engineer-in-Charge.
S&F in repair CP soap dish, fancy type fixed to wall with CP brass screws , complete all as specified and as directed by Engineer-in-Charge.
Taking down old rusted and demaged steel window/vent incl. guard bar and grill where exist of size not exc 1.5 sqm each complete all as specified and as directed by Engineer-in-Charge.
S&F factory fabricated pressed steel frame/box windows, ventilators with glazed and fly proof shutters provided to size and dimension as specified & shown on drawing No BTD-888R Sheet No 1/5 to 5/5 & BTD-889 Sheet No 1/4 to 4/4 Or as directed by GE with & including MS grills, MS fillets, pintol hinges, tower bolts, MS handles, peg stays, MS lugs, locking arrangement, dash through bolt where required, etc complete all as specified and as directed. Notes: -(i) PCC for filling in frames, glass, wire gauge and painting shall be measured & paid in separately under respective items. Provision of all other items as shown & specified on drawings shall deemed to be include in provision of cutting holes of suitable depth in walls for inserting lugs etc and making good dismantled portion in PCC 1:2:4 type B-0 using 12.5 mm graded stone crushed stone aggregate and CM (1:3)
Hacking out old broken glass (any thickness, size, quality or description) from wooden/steel frames or stone or concrete or bricks surrounds glazesd with putty complete all as specified.
S&F Figured glass, pin head type, 4mm thick and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and as directed by Engineer-in-Charge.
S&F Sheet glass 3mm thick, ordinary quality & glazing with oil putty in squares n.exc 0.5 sqm in each pane complete all as specified. Note - scaffolding and security arrangement will be of contractor .
S&F Sheet glass 4mm thick, ordinary quality & glazing with oil putty in squares exc 0.5 sqm in each pane complete all as specified. Note - scaffolding and security arrangement will be of contractor .
Taking down or up, 15 mm bore galvanised steel tubing and connections including cleaning for refixing or removal complete all as specified.
S&F GI tubing medium grade with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 15 mm complete all as specified.
Refixing old GI tubing with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 15 mm complete all as specified.
Taking down or up, 20 mm bore galvanised steel tubing and connections including cleaning for refixing or removal complete all as specified.
S&F GI tubing medium grade with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 20 mm complete all as specified.
Refixing old GI tubing with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 20 mm complete all as specified.
Taking down or up, 25 mm bore galvanised steel tubing and connections including cleaning for refixing or removal complete all as specified.
S&F GI tubing medium grade with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 25 mm complete all as specified.
S&F in repairs Bib taps brass cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule for 15 mm bore GI pipe complete all as specified and as directed by Engineer-in-Charge.
S&F in repair Pillar taps, cast copper alloy, with capstan head, chromium plated, screwed down, high pressure with long screwed shank and fly nuts, screwed for 15mm bore dia iron pipe complete all as specified and as directed by Engineer-in-Charge.
S&F in repair grating 75mm dia of stainless steel with and without hole having minimum weight 75 gm complete all as specified.
S&F in repairs Stop valves/angle valves , cast copper alloy screwed down, high pressure, brass with crutch or butterfly handle, screwed both ends for iron pipe or for unions, for bore dia of pipe 15 mm bore complete.
S & F in repair Ball valves 15 mm bore, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of 15 mm dia (minimum weight 142 Gms) and fixed.
S&F in repair PVC connection 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs PVC valveless, syphonic action type flushing cistern, low level , white, with inlet ball valve, float and handle including brackets 10 litres capacity complete all as specified and as directed by Engineer-in-Charge.
M&L Vitreous china wash basin, white, flat back, size 580 x 440mm, including brackets and cutting for and pinning in ends of brackets, fixed in repairs including 32mm bore brass chromium plated waste fitting and 32mm bore PVC waste pipe of sufficient length complete.
S&F in repairs Vitreous china Squatting pan , 'Orissa pattern, size 580x440 mm white, with integral foot rest excluding flushing cistern and flush pipe including connection to trap, to flushing pipe, anti-syphonage pipe, etc complete including making good to floor .
Dismantling Rotational Moulded plyethyelene water strogr tank of capacity exc 250 lit but not exc 500 lit complete all as specified and as directed by Engineer-in-Charge.
S&F Rotational moulded polyethylene water storage tanks of capacity 500 litres, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc complete all as specified. Notes :- (i) The water storage tanks shall be 3 layers, HDPE tanks moulded to seem-less perfection of rotational moulding process. The tanks shall be manufactured only from FDA approved special grade of polyethylene and shall be certified fit for potable water. (ii) The tanks shall be white coloured and ISI marked. Also refer paras 18.60 and 18.60 A of MES Schedule Part-I. (iii) Payment for inlet, outlet and over flow pipes shall be made separately. However cost of providing necessary GI fittings such as nipples with check nuts for inlet and outlet pipes, GI plug with check nut for over flow pipe and 30 cm long wash out pipe, GI 20mm nominal bore, medium grade and check nut for wash out pipes of size as per actual requirements and ball valve as directed by the Engineer-in-Charge shall be deemed to be included in the unit rate of this item.
Cleaning of Rotational Moulded plyethyelene water storage tank of capacity 500 litre complete all as specified and as directed by Engineer-in-Charge.
S&F 32mm in repair waste coupling CP for wash hand basin complete all as specified.
S&F in repair PVC waste pipe 32 mm for wash hand basin complete all as specified.
S&F in repair PVC cover (lid only) for PVC water storage tank of capacity 500 Ltrs with locking arrangement & hinges complete all as specified.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories)
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed by Engineer-in-Charge.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed by Engineer-in-Charge.
S&F in repair PVC Pipe (SWR) floor trap with grating including jointing to waste pipe fixed in cement concrete type B-1 1:2:4, 75mm dia complete all as specified and as directed by Engineer-in-Charge.
S&F PVC Pipe (SWR) bends (any radius), disminishing pieces or tappers 110mm dia with access door complete all as specified and as directed by Engineer-in-Charge.
S&F in PVC Pipe (SWR) bends (any radius), disminishing pieces or tappers 75mm dia with access door complete all as specified and as directed by Engineer-in-Charge.
S&F in PVC Pipe (SWR) branch pieces ,Double (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches 110 mm dia complete all as specified and as directed by Engineer-in-Charge.
S&F in repair PVC vent cowls 110mm dia complete all as specified and as directed by Engineer-in-Charge.
M&L Taking down cement or cement lime plaster/ grit, terrazo finish of any description from brick or stone walls including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by Engineer-in-Charge.
M&L Rendering 5 mm thick in cement and sand mortar 1:3 on cement concrete surfaces as on ceiling including finishing the surface even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. (Note: Contractor shall have no claim on if plaster is carried out in patches irrespective of any height )
M&L Rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar 1:6 finished even & smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. (Note: Contractor shall have no claim on if plaster is carried out in patches irrespective of any height )
M&L Rendering 15mm thick on fair faces of brick in cement mortar 1:4 finished even & smooth without using extra cement with using liquid water proofing compound as per manufacturer instructions complete all as specified and as directed by Engineer-in-Charge. (Note :- Water proofing compound shall be measured and paid separately)
Supply only liquid integral water proofing compound ISI Marked complete all as specified and as directed by Engineer-in-Charge.
Preparation of newly plastered surfaces of wall including cornices, pillasters etc and applying two coats of cement based paint, white or tinted over a coat of alkali resistant priming paint complete all as specified.
Preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed by Engineer-in-Charge.
Preparing new surfaces (plastered or un-plastered ) of walls including cornices, pilasters etc and applying two coats of white wash complete all as specified.
M&L for preparation of newly plastered surfaces of wall & chajjas and applying two coats of Acrylic emulsion paint (Exterior grade) of approved shade/tint over a coat of suitable priming paint complete all as specified & as directed.
M&L for applying two coat of oil bond distemper on walls after preparation of newly plastered surfaces complete all as specified and as directed by Engineer-in-Charge.
M & L for preparation of old surfaces by complete removal of existing treatment of walls incl paillars etc. by mechanical equipment like electric wall sander and applying two coats of oil bound distemper using rollers over a coat of primer incl 3mm thick wall care putty complete all as specified and as directed by Engr-in-Charge.
M & L for preparation of old surfaces by complete removal of existing treatment of walls incl paillars etc. by mechanical equipment like electric wall sander and applying two coats of cement base paint, white or tinted over a primer , all as specified and directed
M & L for preparation of old surfaces by complete removal of existing treatment of walls incl paillars etc. by mechanical equipment like electric wall sander and applying two coats of oil bound distemper using rollers over a coat of primer incl 3mm thick wall care putty complete all as specified and as directed by Engr-in-Charge.
M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces and applying two coats of Acrylic emulsion paint (Exterior grade) /apex of approved shade/tint over a coat of suitable priming paint on walls complete all as specified and as directed. Note : Height of building to be deemed upto 18 m and rate be including necessary scafolding. all as specfied and directed
M & L for preparation of old surfaces of walls incl paillars etc. and applying a coats of cement base paint, white or tinted over a primer , all as specified and directed
Painting to old steel surfaces of any description not otherwise described over 10 cm in width or girth including preparation of surfaces, with one coats of synthetic enamel paint complete all as specified.
Painting to new steel surfaces of any description not otherwise described over 10 cm in width or girth including preparation of surfaces, with two coats of synthetic enamel paint over coat of primer red oxide .complete all as specified.
Demolition of cement concrete (un-reinforced) in ground floors and pavings n.exc 15 cm thickness (below or above GL) complete all as specified.
M&L 25 mm thick PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate in any position in floor/roof complete all as specified.
M&L 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) in plinth protections/hardstanding, finished even and smooth w/o using extra cement complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engineer-in-Charge.
M&L Non skid coloured ceramic tiles area exc 0.06 sqm but not exc 0.11 sqm 7 to 8 mm thick as in floor etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 15 mm thick screed bed in cement and sand mortar 1:6, complete all as specified and as directed by Engineer-in-Charge.
M&L Non skid coloured ceramic tiles area exc 0.11 sqm but not exc 0.18 sqm 7 to 8 mm thick as in floor etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 15 mm thick screed bed in cement and sand mortar 1:6, complete all as specified and as directed by Engineer-in-Charge.
Ditto all as per item No 90 above but on vertical surface over 10 mm thick rendering in CM (1:4) complete all as specified and as directed by Engineer-in-Charge.
M&L coloured Glazed ceramic tiles in vertical surfaces 350 x 250 x7 mm/ 450 x 300 x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over & incl.10 mm thick screed bed in CM 1:4.complete all as specified and as directed by Engineer-in-Charge.
M&L for 25mm thick sand filling under floors, cushning under interlocking tiles or in foundations incl watering and consolidations complete all as specified and as directed by Engineer-in-Charge.
M&L 60mm thick factory made coloured mixed with pigment precast concrete interlocking paver block of grade M-35 confirming to IS 15658-2006 manufactured by vibratory process laid over sand cushioning complete all as specified & directed.
Dismantling of Roof tiles of any description or thickness in floor, apron etc laid, bedded and pointed in cement mortar complete all as specified.
Demolition of lime concrete of any description over roof slab complete all as specified and as directed by Engineer-in-Charge.
M&L for 10mm thick Rendering in cement mortar 1: 4 on concrete surfaces, finished Fair & even including mixing water proofing compound as per manufacturer's instruction. (Note :- Water proofing compound shall be measured and paid separately)
M&L for Preparing surface and cleaning of concrete slab by wire brushing and applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.20 Kg per sq m including cleaning surfaces complete all as specified.
S&F 150 micron polyethylene sheet supplied and fixed complete all as specified and as directed by Engineer-in-Charge
M&L Lime concrete terracing as in roof complete all as specified and as directed by Engineer-in-Charge. NOTE:- For lime concrete, mudia kankar (source : NAL) and Kolayat coarse sand in lieu of brick aggregates and Surkhi respectively as specified in MES schedule Part-I shall be used.
M&L for 40 mm thick brick tiles bedded on 10mm thick CM 1:6 and joints grouted flush in cement and sand mortar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified.
Ditto all as per Srl item No 101 but except tiles complete all as specified and as directed by Engineer-in-Charge.
M& L for cement mortar for raking out joints/ pointing to brick tiles laid flat in roofs and flush pointing tiles 30 cm by 15 cm tiles laid flat in 1:3 cement mortar complete all as specified and as directed by Engineer-in-Charge.
S& F in repair Sheet glass self assembly consisting of 5.5 mm thick sheet glass self 12 cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and as directed by Engineer-in-Charge.
Demolition of Brickwork , built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed by Engineer-in-Charge.
M&L Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and as directed by Engineer-in-Charge.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings all as specified and directeed
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified all as specified and directed by Engr -in - Charge
Ditto all as above ser No108 but except sheets complete all as specified and as directed by Engineer-in-Charge.
S&F 1.25mm thick Steel rolling shutters, with out ball bearing, as specified including top cover, an choring rod, hasp and staple and one shop coat of primer; erected in position as indi cated, complete: push pull or manual type complete all as specified and as directed by Engineer-in-Charge.
Demolition of cement concrete (reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified.
M & L for design mix RCC M-25 (20 mm graded stone aggregate) in slab supported on walls, beams and coloums in roofs, floors, balconies, canopies desk slabs and in selves complete all as specified and as directed by Engineer-in-Charge.
M & L for form work in soffits of suspended slabs such as roofs slabs, landing,and similar work not exc 200mm thick flat finished rough to obtain plaster complete all as specified and as directed by Engineer-in-Charge.
M & L for form work to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide complete all as specified and as directed by Engineer-in-Charge.
M & L for Mild steel TMT bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality conforming to complete as specified.
Ditto as per item no 115 above ,but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed by Engineer-in-Charge.
Dismantling structural steel work including door gates etc complete all as specified as directed by Engr- in- charge.
M&L running welding in repairs with thickness of metal not exc 6 mm including provision for stopper of peg stay steel handle fitting complete all as specified and as directed by Engineer-in-Charge.
M&L welding in repairs not exc 2.5 cm in length and not exc 6 mm thick of metal complete all as specified and as directed by Engineer-in-Charge.
Dismantling Chain link fencing wire, any type complete all as specified and as directed by Engineer-in-Charge.
Fixing only chain link fencing including line wires 75x75 mm mesh size, 10 gauge galvinised mild steel to any type of standards, rail, straining bolts, complete all as specified and as directed by Engineer-in-Charge.
Supply only chain link fencing , galvinised mild steel of mesh any size and type complete all as specified and as directed by Engineer-in-Charge.
M&L mild steel round bars 10 mm dia or over, cut to length, bend to shape required, fixed independently to support chain link fencing complete all as specified. Fe 410-0 or Fe 310-0 . Gde E-250 Quality A
M&L for Mild steel work conforming to Fe-290 Gde E-165 in nosing to steps including embeding in concrete and screwing etc, wind ties for roof including securing bolts, posts & struts in fencing including cutting top to shape as directed, drilling holes, notching for wire, etc, flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc complete.
M&L Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, ladders etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing of GDE Fe410-0 or Fe 310-O complete.
Supply and Fixing mild steel work as in flats , ties, straps complete all as specified and as directed by Engineer-in-Charge.
S&F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm to 80mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins complete all as specified and as directed by Engineer-in-Charge.
S&F 450 mm bore Reinforced concrete pipes, class NP3, laid and jointed complete with collars all as specified and directed by Engineer -in-Charge
S & F Mild steel plates, plain or chequered, 5mm thick or over in thickness (Fe 410-W (Gde-E- 250) quality-A in available sizes all as specified and directed by engr in charge
Providing precast reinforced cement concrete 1:2:4 type B-1 using 12.5 mm graded stone aggregate in cover slabs (for manholes etc), shelves and similar articles with plain faces including necessary moulds and setting in cement mortar 1:4 complete (reinforcement to be measured separately)
M&L for Mild steel TMT bars 6 to 8mm dia and over as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by Engineer-in-Charge.
Taking down/out loose & damaged concrete/cement plaster from soffits of ceilings, floor/roof slabs, vertical surfaces of columns, beams etc., including exposing and removing rust fron the reinforcement by rubbing with wire brush and removal of debris to a distance n. exc. 100 mtr and depositing where directed
M&L for cleaning existing reinforcement bars with wire brush/rotary wire brush making the surface free from cement skin, loose particle, dirt etc and applying rust remover (Rustoff 100 of Sika/ '8832GM' pidilite or equivelent of Fosroc/ Dr Fixit) on the rebars and removing the loose rust particles after minimum 24 hours by wire brush, all as per manufacture's instructions, complete all as specified and as directed.
S&F hard drawn steel wire fabric, weight not exc 4 Kg per sqm , cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9 mm in dia, supplied and fixed in reinforcement , complete all as specified and as directed.
M&L for cement based polymer modified anti corrosive rebar coating system ('Sika Top Armatec-108 " of Sika or equivalent of Dr. Fixit/ Fosroc) to existing reinforcement all as per manufacture 's instructions, complete all as specified and as directed. Note: Mode of measurment shall be affected surface area of column, beam, slab etc.
M&L for one layer of 20 mm thick concrete (comprises composition 1:2:1 plain cement concrete i.e. One part of cement (43 Gde OPC), two part of fine aggregate and one part of 10 mm and down size trap stone aggregate) mixed with 'Sprayset SL' of Fosroc( Equivalent to Sika / Dr Fixit) 2 to 2.5% by weight of cement and 12.5 to 16.5 liter of water mixed as per manufacture's instuctions and guniting by pressure nozzle with a delivery capacity of 2.5 Kg per sqm over column , beam, roof , slab, etc complete all as specified and as directed.
Taking down carefully (aluminium) point wiring complete of any type (batten/ surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as spcified and directed.
Taking down submain wiring Aluminium/ copper of any size including earth continuity condutor on teak wood or conduit and removing from site and making good the disturbed surface of wall etc complete all as specified and directed.
Taking down old U/S existing DB TPN/SPN DBs any type & any way including MCB/MCCB of any capacity and any size and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed.
M & L for point wiring for one light/fan/bell/buzzer point controlled by one way switch with 1.5 sqmm single core PVC insulated and sheathed multi stranded copper conductor FRLSH cable 1100 volts grade (ISI Marked) including 1.5 sqmm single core PVC insulated and sheathed multi stranded copper conductor FRLSH cable 1100 volts grade (ISI Marked) as continues earth wire in green colour to coomon earth dolly laid/drawn into and including non metalic PVC concealed conduit (medium duty, ISI marked not less than 20 mm dia) with all fittings such as tee, bends etc all as per IS terminated in & including new modular metal flush boxes of requisite module concealed in wall for mounting fittings like modular Switches, sockets, regulators etc with and including modular cover plates with frame of requisite modules all as specified and as directed: Notes:- (i) Cost of cutting/leaving forming chases for conduit, sinking for metal flush boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item. (ii) The quoted rates of this item shall deemed for include for modular metal flush boxes of requisite module and modular cover plate with frame of requisite module of colour as approved by GE
(b)One pin 5 amps socket point on the same board with other switches complete
(c) One 3 pin 5 amps socket on independent board.
Ditto all as per item No 140 here -in- before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 4.0 sqmm single core PVC insulated and and sheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 4.0 Sqmm single core PVC insulated and sheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour complete all as specified and directed .
S&F switch Modular type, 6 Amp, 1 module single pole one way, 230 Volts, Modular type complete all as specified and as directed by Engr- in -charge.
S&F switch Modular type, 16 Amp, 1 module single pole one way, 230 Volts, Modular type complete all as specified and as directed by Engr- in -charge.
M&L socket outlet 3 Pin 6 Amps modular type, 2/3 pin combined 2 module 230 Volts complete all as specified and directed by Engr-in-Charge.
M&L socket outlet 3 Pin 6/16 Amps modular type, 2/3 pin combined 2 module 230 Volts complete all as specified and directed by Engr-in-Charge.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and as directed by engineer-in-charge.
S&F ceiling rose, surface backelite , three terminal AC, 230 volt complete all as specified.
Removing and Refixing LED tube light fitting, 1x 20-22 watts, 230 volt, basic all purpose surface and wall mounted led batten with polycarbonate housing & integrated electronic driver, pre-wired and fixed on walls with all fixing accessories such as screws, clips etc and connecting up with two core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge.
S&F LED tube light fitting, 1x 20-22 watts, 230 volt, basic all purpose surface and wall mounted led batten with polycarbonate housing & integrated electronic driver, pre-wired and fixed on walls with all fixing accessories such as screws, clips etc and connecting up with two core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge.
Supply and fixing LED mirror light fitting , type with high out put diffuser 2 feet, 5watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engr-in-charge
S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-charge.
M & L Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by Engineer-in-charge.
S&F LED Bulb 9W, operating voltage- 220-240 volts, starting time < 0.5s, color temperature-6500K, lumens: min 825 complete all as specified and directed by Engineer-in-charge.
Supply and fixing LED Bldg security/street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
S&F GI bracket made out of 40 mm bore GI pipe light grade /medume grade, ISI marked, medium grade 1.2m long bent to shape suitable for fixing of street light fitting including with 2 Nos MS clamps made with 40x3mm flat iron, bolts, nuts, washers etc including two coats of synthetic enamel paint over one coat of zinc chrome primer and fixing on electric pole complete all as specified and as directed by Engr-in-charge.
Taking down ceiling fan,sealing cable end, dismantling blades of any make, any sweep, and refixing after necessary repairing such as winding of motor, replacement of capacitor & ball bearing of ceiling fan, cleaning all dust & painting with existing colour synthetic enamel paint by spraying including filling cavities with filler,one coat including writing MES No. all as specified and directed by Engr-in-charge
supply and fixing fan step regulator modular type,120W -2 module electronic socket type five step controlled 230V AC 50 Hz for complete all as specified and directed by Engr-In-Charge.
Taking down exhaust fan,sealing cable end, dismantling blades of any make, any sweep, and refixing after necessary repairing such as winding of motor, replacement of capacitor & ball bearing of ceiling fan, cleaning all dust & painting with existing colour synthetic enamel paint by spraying including filling cavities with filler,one coat including writing MES No. all as specified and directed by Engr-in-charge
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm
Taking down and refixing water heater storage type of 25 ltrs capactiy and 1500 watts, BEE Star rated-5, with glass line inner shell with Hot & Cold pipe, water connection pipe, electric connection and necessary repairing/replacement of inner tank, siphon assembly, glass wool, thermostate switch, heating element including washers, 3 core PVC insulated copper conductor cable etc including fixing arrangement complete all as specified and directed.
S & F double door, sheet metal enclosure, powder coated for MCB DB SPN 12 way fitted with neutral link, earth bar , din rail and 200 amps rated bus bar 230 volt conforming to IS 13032-1991 complete all as specified and as directed by Engr-in-charge.
S & F double door, sheet metal enclosure, powder coated for MCB DB SPN 8 way fitted with neutral link, earth bar , din rail and 200 amps rated bus bar 230 volt conforming to IS 13032-1991 complete all as specified and as directed by Engr-in-charge.
S & F MCB SP, 5-32 Amps , 240 volts, breaking capacity 10KA complete all as specified and as dircted by Engr-in-charge.
S & F MCB SPN, 5-32 Amps, 240 volts, breaking capacity 10KA complete all as specified and as dircted by Engr-in-charge.
M&L for submain (Single Phase) wiring using 2 runs of single core FRLS PVC insulated, unsheathed stranded copper conductor cable of size 2runs of 6 Sqmm of voltage rating 1100V for Single phase & neutral, drawn in and including concealed PVC conduit of dia not less than 25 mm dia with standard acessories, along with two run of FRLS PVC insulated, unsheathed, stranded copper conductor of size 1 x 6.0 Sqmm as earth continuity conductor all as specified and directed. (Note-2 runs of single core FRLS PVC cable 6sqmm for Single phase & neutral with one run of earth conductor as earth and conduit shall be measured as one unit)
M&L for Earthing complete with galvanized steel earth plate electrode 60cm x60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level connecting to the galvanised earth lead wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanized iron and steel earth wire protected by provision of GI mediumgrade pipe 15mm bore including provision of concrete pit made with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4Kg/Sqm) and frame of angle iron 40x 40x6 mm and handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering perforated at bottom, 1.75meter long placed on top edge of earth plate, common salt & charcoal filling with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returing filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate No -5 of SSR 2009 Part-I and connecting to Lighting protection earth test points all as specifed and directed including testing on completion.
S&F Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size all as per specified and directed by Engr-in-Charge
All as per item No 169 but for HT, 25x20cm size.
Supplying and fixing SS board frame with square pipe (25mm x 25mm) of size 1200 x 900 x 150 mm made out of 2 mm thick box type, suitable for Flex fitting having Letter, Symbols, Borders as approved by Engr-in-charge. Board will be fixed to stainless steel 50mm tube, 2 to 4 mtr long welded to the frame with adequate anti-theft arrangment.Flex will be easy to fit and remove from frame. frame having arrangment for fixing required LED light fiting (min two nos) complete with all as per specified and directed by Engr-in-Charge. Note : (i) LED Light, Cable and connections accessories is include in quoted Rate. (ii) Flex design should be check before printing. (iii) Board shall be fixed in PCC foundation rate shall be deemed to be included in the quoted rate all as directed by Engr-in-Charge. (iv) for each board two no of flex will be provided.
S&F of warning Sign board of different size/shapes and design for water/electric installations. (Board size Min 300 x 300mm and Max 500 x 500 mm). Thecontent of board will be desribed by Engr-in-charge. Sign board will be fixed on Wall/fence/pole. Note : (i) Size and design should be approved by Engr-in-Charge. (ii) Rate for printing/Painting and fixing of board with proper manner incl in quoted rate.
A.S. CONSTRUCTION COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .