Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹49.9 L+₹1.4 L (2.83%)Rejected-AOC C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L2 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 3 | L3₹53.3 L+₹4.7 L (9.78%)Rejected-AOC | L3 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 4 | Rejected-Technical NEAR PUNJAB NATIONAL BANK KANDOLI NAGROTA JAMMU J K 181221 | JAMMU | JAMMU | JAMMU AND KASHMIR | 181221 | - | Rejected-Technical NOT ENLISTED IN APPROPRIATE CATEGORY |
Tender Value
₹49.9 L
EMD Value
₹98,800
Closing Date
6 Jul 2023, 6:00 pmClosed
GE NAGROTA
GE NAGROTA
SHIFTING OF UTILITIES KM 15.661 OVER BALINI RIVER ON JAMMU SRINAGAR ROAD PROVN OF GUARDROOM AND SPECIAL REPAIRS TO BUILDING NO B 7 UNDER GE NAGROTA
2023_MES_588935_3
GEN-04/2023-24
Open Tender
Electrical and Maintenance Works
Works
180 days
GE NAGROTA
REFER NOTICE OF TENDER
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹98,800
Yes
24 Aug 2023
17 Jun 2023
8 Jul 2023
17 Jun 2023
6 Jul 2023
24 Jun 2023
Amount
SCHEDULE ‘A’ PART-I Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in Soft/ loose soil complete all as specified and directed
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in any type of soil complete all as specified and directed
Excavation in trenches, not exceeding 1.5 M wide and exceeding 1.5 M but not exceeding 3 M depth for foundation, etc., and getting out in Soft/ loose soil complete all as specified and directed
Surface excavation n.exc 30cm deep and avg 15 cm deep and getting out any type of soil complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soilscomplete all as specified and directed.
Removing Excavated soils not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed
Spreading and levelling & filling in layers n exc. 25 cm thick incl well ramming including watering as required complete all as specified and directed Note : Soil obtained from excavation shall be used for filling
M & L Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed
M&L for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed.
M & L Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed
M&L for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed.
M & L for Plain Cement Concrete Type D-2 1:4:8 (using 40 mm graded granite stone aggregate) in foundations, filling and mass concrete complete all as specified and directed
M & L for 75 mm thick Cement concrete type D 2, 1:4:8 (using 40 mm graded granite stone aggregate) in sub base of flooring/ hard standing.
M & L for Brick work with sub-class `B' old size bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and directed
M & L for Brickwork with sub-class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed
M & L for Reinforced cement concretetc M-25 (design Mix) using 20mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed
M & L for Reinforced cement concretetc M-25 (design Mix) using 20mm graded stone aggregate as in Columns, pillars, piers, posts and struts complete all as specified and directed
M & L for Reinforced cement concretetc M-25 (design Mix) using 20mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed
M & L for Reinforced Cement Concrete Type B1 1:2:4 (using 20 mm graded stone aggregate) as in slab suspended on walls, beams and columns, in floors, roofs, landings and in shelves and the like complete all as specified and directed.
M & L Precast cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in cover slab , set in CM 1:4 incl necessary formwork complete all as specified and directed
M & L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces complete all as specified and directed
M/L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
M/L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces complete all as specified and directed
M & L for Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail- ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similarwork exc 10cm but n exc 20cm wide for rough finished surfaces complete all as specified and directed
M & L for TMT bar 10mm dia and over cut to length bend to shape required indd cranking bending spirally for column, hooking ends & binding with and incld mild steel wire (annealed) not less than 0.90mm dia or securing with chipscomplete all as specified and directed
M & L for Mild steel TMT bars 8 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, beams,hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed.
M & L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups,spacers and binders complete all as specified and directed
M & L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished fair and even without using extra cement.complete all as specified and directed
M&L for plain cement concrete type B1 1:2:4 (20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , hold fast block , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete all as specified and directed.
M&L for Machine cut kota stone slab as in flooring 20-25mm thick over and including 20 mm thick in cement mortar 1:6 screed bed , laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror finish polishing complete all as specified and directed
M&L for Machine cut kota stone slab as in dado / skirting 20-25mm thick over and including 20 mm thick in cement mortar 1:6 screed bed , laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror finish polishing complete all as specified and directed
M&L for Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15 mm thick in cement mortar 1:6 screed bed or bedding layer of mortar for laying floor finishes complete all as specified and directed
M&L for Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in dado / skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 10 mm thick in cement mortar 1:4 screed bed or bedding layer of mortar for laying floor finishes complete all as specified and directed
M&L for non skid cereamic coloured tiles 7 to 8mm thick (square/ rectangle) area of each tiles exceeding 0.11 sqm but n. exc.0.18 sqm, in floor etc set and joined in neat cement slurry and pointed in white or .coloured cement to match including 15 mm thick in cement mortar 1:6 screed bed or bedding layer of mortar for laying floor finishes complete all as specified and directed
S & F solid PVC door frames of sizes 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube complete all as specified and as directed.
S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawingcomplete all as specified and directed .
S & F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed .
S & F Box type Steel window side hung double shutters with provision for desert cooler/AC(inside for wire mesh & out side for glass), including guard bar,hinges, steel handle, tower bolt and steel peg stay complete with glazing bar dovetailed or welded and fixed, steel window shall be conforming to relevant IS complete all as shown on drawing No CEUZ/TD/1302/09, Sh 1/3 to 3/3 complete all as specified and directed Note:- Wire mesh and sheet glass shall be measured and paid separately complete all as specified and directed
S & F Box type Steel ventilators top hung double shutters (inside for wire mesh & out side for glass), including hinges, steel handle, tower bolt and steel peg stay complete with glazing bar dovetailed or welded including a coat of red oxide after preparation of surface before fixing.Steel window shall be conforming to relevant IS all as specified. Note:- Wire mesh and sheet glass shall be measured and paid separately complete all as specified and directed
S & F 200 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed
S & F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed
Supply and fix 300mm long aluminium alloy, anodized sliding door bolt with hasp stapple ( bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed .
S & F Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and directed
S & F Small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary' labours; articles n exc 200 cu. cm each using 2nd class hard wood incl 50 mm MS butt hinge complete all as specified and directed
S & F 300 mm long 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete complete all as specified and directed
S & F 100 mm long medium weight, cold rolled mild steel Butt hinges complete all as specified and directed
S & F 100 mm long Butt hinges, extruded alu- minium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and directed
S & F 150mm size extruded aluminium handle cast type anodised complete all as specified and directed
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes, single socketed in any length with rubber ring joints laid in floors or trenches, etc including necessary excavation & earth work whenever required complete all as specified and directed
S & F 110mm bore PVC (SWR) Soil, waste and vent pipes, single socketed in any length with rubber ring joints fixeed to walls with suitable size of clamps , nuts-bolts complete all as specified and directed
S & F 110 mm bore PVC (SWR) bends any radius. complete all as specified and directed
S & F 75/110 mm bore PVC (SWR) reducer complete all as specified and directed
S & F 100 mm bore Bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed
S & F 75 mm bore Bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed
S & F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed
S & F Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed
S & F stop valve 15 mm bore cast copper alloy chromonium plated screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed
S & F stop valve 20 mm bore cast copper alloy chromonium plated screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions. complete all as specified and directed
S & F PVC connection pipe 15mm size with PTMT nuts of 600 length including fixed complete all as specified and directed .
S&F 1000 ltr capacity Rotational moulded polythylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position with & incl 20 mm bore Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed
M&L for Rendering 15mm thick in in cement mortar (1:4)] with water proofing compound in on brick work or concrete surfaces of wall, surfaces finished even and smooth using extra cement complete all as specified & directed. Note : WPC shall be measured and paid separately.
M&L for Rendering 15mm thick in two layers [base layer 10mm in CM 1:4 & finishing layer 5mm thick in cement mortar (1:4)] using water proofing compound in 2nd layer only on brick work or concrete surfaces of wall, surfaces finished even and smooth using extra cement complete all as specified & directed. Note : WPC shall be measured and paid separately.
M&L For extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including form moulds mitred/stopped ends etc. complete all as specified and directed
M/L 100 mm thick Cement concrete Type C-2 1:2:4 (using 40 mm graded stone aggregate) in sub base of floor complete all as specified and directed
M&L plain cement concrete 1:4:8, type D2( using 40mm graded stone aggregate) 40mm thick as in floor complete all as specified and directed .
M&L for 60mm thick machine pressed precast concrete interlocking paver block (glossy finish) of M-35 Gde of approved shape, size and colour conferming to IS 15658-2006 and laid over and including 25 mm thick sand cushion complete all as specified and directed.
M&L PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate as in damp proof course mixed with water proofing compound complete all as specified & directed.
M&L Hard core of gauze n.exc 63mm deposited spreaded and leveled in layers n.exc 15cm thick, watered and rolled/rammed to a true surface complete all as specified and directed .
Supply and fix 75 mm bore Cast iron cowls complete all as specified and directed.
Supply and fix Tubular towel rail, 20mm dia, D type, 60cm long between flanges fixed in repairs complete all as specified and directed.
Supply and fix Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) fixed in repairs complete all as specified and directed.
Supply and fix Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed.
Supply and fix Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long fixed in repairs complete all as specified and directed. Make Cat Part No CAN 1173of Jaquar or equivalent
S&F of 125 mm dia Fancy type Chromiun plated shower rose shower rose type fixed to 15mm dia pipe complete all as specified and directed.
Supply and fixing Vitreous China Urinal, full stall type, white with PTMT waste fitting, PVC waste pipe, brass CP urinal spreader including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc 1.50 sqm each and removing from site complete all as specified and directed. .
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc 1.50 sqm eachand n exc 4 sqm and removing from site complete all as specified and directed. .
Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing), and rubbish off the premises complete all as specified and directed.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets, etc complete all as specified & directed.
Demolition of brick work built in cement mortar including all quions, arches, pillars etc but excluding ashlar facings dressed stone work and precast concrete articles complete all as specified and directed. .
Demolition of cement concrete (unreinforced) in ground floors and paving not exc 15cm thickness complete all as specified and directed
Taking down cement plaster on brick or stone wall etc including racking out joints, hacking for key scrubbing down with water etc to receive new plaster complete all as specified and directed.
Supply and fix Pressed steel frames of size 125 mm X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc including two coats of synthetic enamel paint over one coat of red oxide complete all as specified and directed
Supply and fix Pressed steel frames of size 105 mm X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc including two coats of synthetic enamel paint over one coat of red oxide complete all as specified and directed
Supply and fix 35 mm thick Factory made, 2nd class hard wood, plain framed, Double/Single paneled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both sides, the size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and directed
Supply and fix 30 mm thick second class hardwood glazed and skeleton shutters for ventilator/windows, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars,. fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (b); supplied and fitted to chowkats complete all as specified.
Supply and fix 3 mm thick Sheet glass,ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed.
Supply and fix Galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm dia and fixed with tinned tacks or galvanised mild steel staples complete all as specified and directed
M&L for 75mm thick cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection finished even and smooth without using extra cement laid in panels and joints filled with bituminous mastic filling with 1 part of bitumen and 3 part of sand complete all as specified and directed.
M&L for 20mm thick Granite (of any type) tiles machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing, complete all as specified and directed.
M & L for Glazed ceramic colored tiles 300mmx600mmx 6 to 7mm thick,as in patches in vertical surfaces such as dado, skirting, wall etc set & jointed in neat cement slurry and pointed with coloured cement to match with tiles in over and including 10mm thick cement plaster in cement mortar 1:4. including dismantaling/demolation/Taking down Note:- Rates also includes in this item for necessary raking, circular cutting or notching and waste on tiles complete all as specified and directed
M&L for Rendering 5 mm thick in CM (1:3) on ceiling finished even and smooth without using extra cement including three coat of white wash on ceiling including preparation of surface complete all as specified and directed .
Supply only Liquid water proofing compound complete all as specified and directed .
M & L for Rendering 10 mm thick on fair faces of concrete surfaces as on roof in cement mortar 1:6 and finished fair and even without using extra cement.complete all as specified and directed
M&L Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces complete all as specified and directed.
M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application over & after applying evenly a tack coat of in dustrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces complete all as specified.
S & F 1/19 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and as directed.
M& L for two coat of synthetic enamel paint over a coat of red oxide primer on new / untreated steel surfaces of any description, not otherwise described over 10 cm width or girth including preparation of surfaces complete all as specified and directed.
M& L for two coat of synthetic enamel paint over a coat of pink primer on new wooden surfaces of any description, not otherwise described over 10 cm width or girth including preparation of surfaces complete all as specified and directed.
M& L forThree coat of white wash on newly plastered surface on wall including preparation of surface complete all as specified and directed.
Preparation of newly plastered surfces of walls and applying two coats of oil bound distemper over & incl one coat of primer complete all as specified and directed
Material and labour for preparation of newly plastered or un plastered surfaces of walls and applying two coats of cement base paint over one coat of primer complete all as specified and directed.
Demolition of stone slabs of any description or thickness in kitchen platform, floors,aprons laid, bedded,pointing in any mortar etc complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning for refixing or removal to store upto 25mm bore complete all as specified and directed .
Supply, lay and fix 15 mm bore galvanised iron water tube medium grade with all fitting and laid in trenches or floor or wall, complete all as specified and directed.
Supply, lay and fix 20 mm bore galvanised iron water tube medium grade with all fitting and laid in trenches or floor or wall, complete all as specified and directed.
Cuttings chases for concealed water tubing of concealed conduit (cutting n.exc 10 cms girth) and making good in CM ( 1:3) in brick walls complete all as specified and directed..
S&F 20 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed..
Cutting and screwing existing G.I tubing of 20 to 50 mm for alterations or additions on pipe for connectors of 20 mm bore (Each cut measured) complete all as specified and directed.
Supply and laying 40 mm bore galvanised iron tubing, light grade conforming to IS -1239 with all fittings for passing of cables along pole with clamps of size 50 x 6 mm made o shape required with 12 mm dia nuts bolts , or under road including cutting of road & making good with PCC 1:2:4 type B-2 complete all as specified as directed
M & L for 15mm bore fancy type bib tap brass CP (Long body) with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and as directed.
M & L for 15mm bore fancy type CP brass Mixer, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and as directed.
S&F Cast copper alloy CP angle / stop Valve fancy type screwed both ends for iron pipe 15mm dia/ bore of pipe complete all as specified and directed
S&F for CP Pillar taps, 15mm fancy type cast copper alloy, with capstan heads, screwed down high pressure, without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed .
S&F for Vitreous china squatting pan “ORISSA” pattern size 630x450mm white with integral foot rests all as fixed in repairs including cast iron ‘P’ or ‘S’ trap 100mm bore , flushing pipe complete fixed in repair complete all as specified and directed
S & F Vitreous china wash down closet pan (Pedestal pattern) white with ‘S’&'P' trap plastic seat cover white including connection to out going pipe & to flushing pipe, anti syphonage pipe etc including making good to floor and fixing in repairs complete all as specified and directed
S & F PVC valve less symphonic action type, flushing cistern, low level, white of capacity 10 ltrs with inlet , ball valve, float and and fixing arrangement including making good to floor and fixing in repairs
S & F Chromium plated health faucet with 1 mtr long easy flex tube for fixing with 15mm pipe alongwith wall hook complete all as specified and directed. Make: Hindware Cat Part No. F160027 or equivalent make of Jaquar(Continental)/Marc/ Parryware
Supply and fix Toilet paper holder with flap recessed type of stainless steel fixed in repairs ,complete all as spcified & directed Make Cat Part No AHS-1553 of Jaquar or equivalent
M&L for Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as spcified & directed .
Supply and fix vitreous china wash basin, white flat back size 550 x 400 mm, excluding taps, waste chain, plug and porcelain stopper but including brackets, cutting for and pinning in ends of bracket complete all as specified.
S & F in repairs sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes;including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed .
S&F for 10 users LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc, complete complete all as specified and directed
M&L for Soakage wells excavation in any type of soil, foundation PCC 1:3:6 walls of honey combed masonry with top ring of M25 concrete inclding intercepting chamber and screen chember made of Bricks measonary I CM, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.2m dia X 3. m effective depth complete all as specified and directed
S&F 75mm bore CI floor trap with grating including jointing CI pipe in run lead, cutting holes in walls and making good surface in cement concrete surface type B-1 (1:2:4) complete all as specified and directed .
S&F 110mm bore PVC ( (SWR) gully / Nahani trap with grating including jointing CI pipe in run lead, cutting holes in walls and making good surface in cement concrete surface type B-1 (1:2:4) complete all as specified and directed .
S&F 75 mm bore PVC ( (SWR) gully / Nahani trap with grating including jointing CI pipe in run lead, cutting holes in walls and making good surface in cement concrete surface type B-1 (1:2:4) complete all as specified and directed .
M & L for 100mm dia/ bore Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed.
M & L for Cutting holes in brick walls exc. half brick but not exc. brick built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required,complete all as spcified & directed
Demolition and breaking up 150mm dia drain pipes (Salt glazed ware, AC or reinforced concrete ) and set in cement mortar ,complete all as spcified & directed
M & L for Concrete bed to drain pipes laid in trenches including packing under and haunching against the sides of pipes aftaer they are laid and tested in cement concrete 1:4:8 type D-2, using 40mm graded crushed stone aggregate for 150mm bore pipe, ,complete all as spcified & directed
M&L for 150 mm bore / inner dia double wall , corrugated HDPE ppes ( SNB) ( ISI marked) with intergrall socket & necessary fittings jointed as directed & laid in trenches complete all as specified & directed.
SCHEDULE ‘A’ PART-II Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.complete all as specified and directed.
Taking down Ceiling fan of any size/sweep for replacing bearing, bush including rewinding after disconnecting the wire from existing ceiling rose and refixing the same after rewinding with super enamelled winding wire ,(minimum winding wire 300 grame / fan) cleaning dust, oiling greasing, servicing and replacing bearing, gun metal bush, rubber reel with clamp and nut-bolt, washer, lock pin, excellation gear sytem, boby painting etc as existing including connecting flexible 3 core cable from ceiling rose to connector of fan complete all as specified and directed.
M&L for Point wiring using FRLS PVC insulated unsheathed multi strand copper conductor cable 1100 volt garde 1.5 sqmm including 1.5 Sqmm FRLS PVC insulated unsheathed multi strand copper conductor earth wire drawn through and including PVC casing capping of suitable size with all fitting and fixture accessories on roof, wall, celling etc terminated in and incl concealed pressed steel sunken box readily available ( having wall thickness not less than 1.22 mm upto 200 x 300 mm box size & having wall thickness not less than 1.63 mm beyond 200 x 300 mm ) duly covered with 3 mm thick bakelite sheet cover for fixing switches , sockets , fan regulators etc incl testing and making good to disturbed surface to match existing surface for one light/fan/bell point complete all as specified and directed.
All as per item No. 136 above above but for one 3 pin socket outlet point, 5 Amps control by one switch on same board with other swithes complete all as specified and directed.
All as per item No. 136 above above but for one 3 pin socket outlet point, 5 Amps control by one switch on independent board complete all as specified and directed.
All as per item 136 above before but point wiring with 2.5 sqmm FRLS multi stranded copper conductor cable for main circuit and 2.5 sqmm cable as earth continuity conductor for one 15 Amp socket out let controlled by one 15 Amp switch on independat board.
All as per item 136 above before but point wiring with 4 sqmm FRLS multi stranded copper conductor cable for main circuit and 4 sqmm cable as earth continuity conductor for one 15 Amp socket out let controlled by two pin with earth plug on independat board.
S&F switch piano flush type 5 Amps single pole one way complete all as specified and directed.
S&F Switch -Socket outlet 2 in 1, 3 pin, 6 and 16 amp flush type complete all as specified and directed.
S&F socket 2 in 1, 3 pin, 5 Amp flush type complete all as specified and directed.
Supply and fix Ceiling rose, 3 phase/PVC/ polycarbonate, isolated body complete all as specified & directed.
S & F Angular Lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings with 10 watt LED lamp complete all as specified and directed.
S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd.complete all as specified and directed.
Supply and fix plastic body exhaust fan, AC single phase, 240 V of size 300 mm sweep with louvers including necessary connection and replacement of flexible copper cable from ceiling rose and taking down of old unserviceable fan complete all as specified and as directed.
Supply and fix ceiling fans complete with blades, down rods, compatible with electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE, 5 star rated with brushless direct current motor BLDC with copper flexible wire from ceiling rose to fan complete all as specified and as directed. Make : Orient hector or equivalent make as specified in PS
S&F Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size ,complete all as spcified & directed
S&F LED linear light fittings 18 Watt basic all purpose surface and wall mounted and LED batten with polycarbonate housing and intrigated electronic driver and connecting with 3 core flexible copper cable PVC insulated of size 16/0.20 mm etc complete all as specified and directed. Make : Orient Cat part no LBLN-18-C-SQAL or equivalent make as specified in PS
Supply and fix LED Bulkhead luminaire 10 W Environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit LED luminaire comprising of high brightness LEDs complete all as specified and directed. Make : Orient Cat part no LIBHP-10-C-V1 or equivalent make as specified in PS
Supply and fix sheet metal enclosure powder coated single phase DB for fixing of MCBs, 12 ways double door with bus bar including grouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed.
S & F MCB SPN 40 -63 Amps C CURVE 10 KA 240 Volts complete all as specified and directed.
S & F MCB SP 6 to 32 Amps C CURVE 10 KA 240 Volts complete all as specified and directed.
Supply and fix street /bldg security light LED luminaire 25 watt IP 66 LED lamp, driver etc, including wall bracket 1.5 mtr long made out of 40 mm bore GI light grade pipe with suitable siz of clamps nuts bolts & all accessories & making connection with FRLS PVC insulated unsheathed multi strand copper conductor cable 1100 volt garde complete all as specified and directed. Make : Havells Endura SUNDOWN SL 25 W LED 765 PA SYBOPCIHD or equivalent make as specified in PS
M & L for circuit /submain wiring along with earth wire 2 x 10 Sqmm PVC FRLS insulated unsheathed cable multi-strand copper conductor including 1 x 10 Sqmm PVC insulated unsheathed multi strand copper conductor earth wire drawn through and including concealed PVC conduit of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bends, junctions box , connecting earth including cutting groove for concealed wiring, making good to disturbed surface of wall/floor with cement mortar and finishes to match existing incl taking down old unserviceable submain wiring complete all as specified and directed. Note: Two run of single core cable and one run of earth wire will be mearsured as one length
S & F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to fe 290 Gde E-165 complete all as specified and as directed.
M & L for sand cushioning with a layer of sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed.
S & L brick covering with width equal to length of brick as the mechanical protection to cable with well burnt sub class 'B' bricks laid in trenches flat complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and directed.
Material and labour for earthing with galvanised steel earth plate electrode 60cmX60cmX 6mm thick burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to GI strip 25 x 4 mm with mild steel nuts bolts checknuts & washers and connected to equipment as directed incl funnel with Gi medium grade watering pipe 20 mm bore , wire mesh , charcoal or coke and commn salt in alternate layers of 15 cm compacted thickness all around the earth electrode with concrete pit in PCC 1:3:6 type C-1 with 50 mm thick precast RCC cover in PCC 1:2:4 type B-1 cover slab reinforced with 8 mm dia deformed bars @ 15 cm c/c with suitable handle of 10 mm dia round bar , 40mm bore medium grade pipe for earth strip protection incl necessary excavation and earth wok in soft / loose soil and disposal of spoil to a distance n exc 50 m and necessary testing complete all as shown in electrical plate No 3 of MES SSR Part-I complete all as specified and directed.
Material and labour for earthing with galvanised steel earth plate electrode 60cmX60cmX 6mm thick burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to earth wire 4 mm dia GI wire with mild steel nuts bolts checknuts & washers and connected to equipment as directed incl funnel with Gi medium grade watering pipe 20 mm bore , wire mesh , charcoal or coke and commn salt in alternate layers of 15 cm compacted thickness all around the earth electrode with concrete pit in PCC 1:3:6 type C-1 with 50 mm thick precast RCC cover in PCC 1:2:4 type B-1 cover slab reinforced with 8 mm dia deformed bars @ 15 cm c/c with suitable handle of 10 mm dia round bar , 15 mm bore medium grade pipe for earth lead protection incl necessary excavation and earth wok in soft / loose soil and disposal of spoil to a distance n exc 50 m and necessary testing complete all as shown in electrical plate No 3 of MES SSR Part-I complete all as specified and directed.
Dismantling concrete poles/ struts, any size incl dismantling PCC and earthwork in any type of soil complete all as specified and directed.
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside complete all as specified and directed.
Dismantling insulators any type, any size. complete all as specified and directed.
Dismantling air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism for repair/ replacement of broken/worn out components and insulators etc. complete all as specified and directed.
Dismantling stay assembly complete all as specified and directed. Note : The rate includes for demolition of concrete, etc. and earthwork
M & L for Plain Cement Concrete Type C-2 1:3:6 (using 40 mm graded granite stone aggregate) in foundations, filling and mass concrete complete all as specified and directed
M & L for Plain Cement Concrete Type B-2 1:2:4 (using 40 mm graded granite stone aggregate) in coping to pole complete all as specified and directed
Supply, laying and testing of XLPE insulated earhehed , screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 95 sqmm 3 core laid in trenhes / etc. complete all as specified and directed.
Supply, laying and testing of Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm . complete all as specified and directed.
Supply, laying and testing of Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed.
Material and labour for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 (Over all length 11 metres long) confirming to IS-2713. Pole shall be painted with two coats of black bituminious paint throughout internally and externally up to planting depth, length from bottom and the remaining external protion shall be painted with two coats of aluminium paint over a coat of red oxide primer and numbering the pole with white paint alfa numaric letters on black patch fixed in repairs complete all as specified and directed. Note: Earthwork and PCC shall be measured and paid for separatly
Supply & fixing Aluminium conductor, steel reinforced of any size on HT poles incl strainng , binding with insulators with aluminium / copper binding wire complete all as specified and directed.
Supply, & fixing of switches Air break, gang operate Triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps , 11000 volts conforming to IS 1818 of 1972 , ( mounted on insulator and steel frame ( 15 Insulator) complete all as specified and directed.
M&L for cross arms bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts,washers,welding, bending cold or hot, drilling holes for bolts, in any shape or sizes as indicated or directed and inclusive of two coats of aluminium paint over a coat of zinc chrome primer, complete all as specified and directed.
Supply, & fixing of Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp , 11000 volts complete all as specified and directed.
Supply, & fixing of 11000 volts Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 50mm height, 65mm dia for 550 volts grade complete all as specified and directed.
Supply, & fixing of 11000 volts Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green: ' with tension clamps for conductors,working pressure 11000 volts Single disc assembly for complete all as specified and directed.
S & F 25 x 4mm GI strip as in Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. complete all as specified and directed.
Supply & fix Stay assembly complete with accessories as shown in electrical plate No. 1 (loop type insulator, stay clamps, excavation and concrete measured separately) Diameter of (excluding) stay rod 18 mm , 180 mm long with 02 nuts , stay bow 14 mm dia & 38 cm long with tay plate 300 x 300 x 6 mm , MS stay thimble Of requiredlength . complete all as specified and directed.
Supply & fix Expanded metal, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members complete all as specified and directed.
Supply & fix Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT of size , 25x20cm . complete all as specified and directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strips or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 16 sqmm 2 core, complete all as specified and directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strips or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 16 sqmm 4 core, complete all as specified and directed.
Supply, laying fixing and testing in replacemnt of 150 mm bore galvanised iron water tube medium grade with all fitting and laid in trenches or floor or wall, complete all as specified and directed.
Supply, installation and testing of Cast Iron Sluice valve, class PN 1.6, ISI marked conforming to IS-14846 / 2000, complete suitable for 150 mm bore pipe with flanges ends duly drilled, brass spindle, CI gate with brass rings and iron wheel head , complete all as specified and directed.
Material and labour for construction of valve pit of brick masonry of size (1 x 1 x 1 m) , internal dimension, built in CM 1:4 complete with Angle Iron frame of size 40 x 40 x 6 mm , 3.15mm thick MS sheet cover and locking arrangement including excavation and earth work and P.C.C 1:3:6 type with provision of two coat of synthetic enamal paint over one coat of red oxide primer, complete all as specified and directed.
M& L for cutting to road upto 1.5 meter in depth & making good in PCC 1:2:4 type B-2 complete all as specified and directed.
M & L for Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') complete all as specified and directed.
M & L for Cutting of 150 / 200 mm bore cast iron / DI pipes and & inserting wew Tee / reducers etc for taking new coonection incl earthwork complete all as specified and directed.
MAMTA ENTERPRISES
Kalsi Engineers and contractors
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .