| Sl No | Description | Qty | Unit | DHARMA TRANSFORMER AND CONTORL PANEL L1 | NIMA ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.00 | Supply of SPD 2 Pole single phase- Surge Protection Device. [Make- Schneider Electric / CNC/ Havells] | 50 | One Each | 1,250 ₹62,500 | 1,200 ₹60,000 |
| 2.00 | Supply of SPD 4 Pole single phase(Surge Protection Device) [Make- Schneider Electric / CNC/ Havells] | 50 | One Each | 1,810 ₹90,500 | 1,800 ₹90,000 |
| 3.00 | Supply of Voltage Monitoring relay with display
Model- SM-800(DMA-220) (Make -GIC India) | 50 | One Each | 3,525 ₹1.8 L | 3,500 ₹1.8 L |
| 4.01 | Providing and erecting AC-3 duty 3 pole power contactor with 2 NO & 2 NC aux contacts complete with 415V/220V operating coil suitable for (L&T, BCH,T.C., Siemens, C&S make).
(i) 25A 3-POLE | 20 | One Each | 3,450 ₹69,000 | 3,500 ₹70,000 |
| 4.02 | (ii) 25A 3-POLE NC | 20 | One Each | 3,450 ₹69,000 | 3,500 ₹70,000 |
| 4.03 | (iii) 25A 3-POLE NO | 20 | One Each | 3,450 ₹69,000 | 3,500 ₹70,000 |
| 4.04 | (iv) 40A | 20 | One Each | 5,120 ₹1.0 L | 5,500 ₹1.1 L |
| 4.05 | (v) 55A | 20 | One Each | 7,275 ₹1.5 L | 7,500 ₹1.5 L |
| 4.06 | (vi) 95A | 30 | One Each | 11,080 ₹3.3 L | 11,000 ₹3.3 L |
| 4.07 | (vii) 110A | 20 | One Each | 15,000 ₹3 L | 15,000 ₹3 L |
Tender Value
₹1.5 Cr
EMD Value
₹2.9 L
Closing Date
13 Jan 2026, 2:30 pmClosed
Executive Engineer III
Executive Engineer PWD Civil Division No.III (Irri), District Panchayat DNH Silvassa
Procurement of Electrical Materials/Equipment for upkeepment of Water Treatment Plant, W/S Scheme and L.I.Scheme in DNH area
2026_UTDNH_7871_1
E TENDER NOTICE NUMBER 42 OF 2025-2026
Open Tender
Miscellaneous Goods
365 days
DNH
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,000
Executive Engineer PWD Civil Div III DP Silvassa
₹2.9 L
9 Apr 2026
6 Jan 2026
13 Jan 2026
6 Jan 2026
13 Jan 2026
6 Jan 2026
Supply of SPD 2 Pole single phase- Surge Protection Device. [Make- Schneider Electric / CNC/ Havells]
Supply of SPD 4 Pole single phase(Surge Protection Device) [Make- Schneider Electric / CNC/ Havells]
Supply of Voltage Monitoring relay with display Model- SM-800(DMA-220) (Make -GIC India)
Providing and erecting AC-3 duty 3 pole power contactor with 2 NO & 2 NC aux contacts complete with 415V/220V operating coil suitable for (L&T, BCH,T.C., Siemens, C&S make). (i) 25A 3-POLE
(ii) 25A 3-POLE NC
(iii) 25A 3-POLE NO
(viii) 250A
Supply of RCBO Relay with including all asscessories material- 2 pole 6A [Make-ABB/Siemen]
Supply of RCBO Relay with including all asscessories material -Three pole 63A [Make-ABB/Siemen]
Supply of MN- 5 Relay (Make-Lauritz Knudsen) (i) 0-36A
Supply of Star Delta Timer - SD22. [Make-Multispan]
Supply of Auxiliary Contacts including all asscessories material (i) LK MNX-A2 ADD ON Block 1NO+1NC (Make-Lauritz Knudsen, Schneider Electric)
(ii) MNX-A6 1L Right & Left side block
(iii) ADD ON Block 1NO+1NC
(iv) Right & Left side block
Supply of LT Starter Contactor including all asscessories material - MK1( Air break 4 pole) (Make- L&T, Snieder)
Supply of Connector for Electrical Panel. (i) (DPBB50)1000 V / 150 A / 50 sq.mm / 3 Nm (Make- L&T, ABB, Siemen)
(ii) (DPBB185N) 1000 V / 353 A / 185 sq.mm / 14 Nm
(iii) DPBB250N)
(iv) 2 line ,3 line and 4 line Electrical cable screw lock wire connector 6-32A
Supply of Digital Time Switches Crono with all asscessories material - 67DDT0 (Crono) (Make-GIC India)
Supply of Lug pin type (RLPI - Insulated Pin Type Terminals) (Make-ABB, 3M, Schneider Electric) (i) 10-120 mm size, Hole size 10mm ring type, (10,16,25,35,70,95,120 cable size lug)
(ii) 2.5-6 mm size,Hole size 8mm,Pin cross sectional Round, Flat, Elliptical type
Supply of Lock Tie - 235x9 mm (Make- Surelock)
Supply of Nut-Bolt with ring vessel - SS 1.5x10 (As instructed by engineer-in-charge)
Supplying & erecting approved make motor control cubical panel [Star delta] made from 16G CRCA sheet duly epoxy powder painted inside and outside with hinged doors and locking with suitable size of ON - OFF isolator (AC 3 / 23 duty) main fuses. Digital volt and current meter (in a single unit) with micro controller based control unit and current sensing single phasing preventer electronic overload protection, over voltage (Programmable) protection and under voltage (Programmable) protection, prod less dry run protection programming facility for setting of all parameter like overload current, high voltage limit, low voltage limit, dry run limit with digital indication on seven segment LED display for any fault like over load, high voltage, low voltage, dry running single crimped, electronic star delta timer, feather touch start / stop push buttons to be erected on angle iron frame. Grouted on wall the contactors will be of L& T, Siemens , BCH make only) (i) 10 HP
Supply of Oil Starter- Star Delta (Make- Jyoti) (i) 7.5 HP to 15 HP
(ii) 15 HP to 25 HP
Supplying & erecting approved make motor control cubical panel [Star delta] made from 16G CRCA sheet duly epoxy powder painted inside and outside with hinged doors and locking with suitable size of ON - OFF isolator (AC 3 / 23 duty) main fuses. Digital volt and current meter (in a single unit) with micro controller based control unit and current sensing single phasing preventer electronic overload protection, over voltage (Programmable) protection and under voltage (Programmable) protection, prod less dry run protection programming facility for setting of all parameter like overload current, high voltage limit, low voltage limit, dry run limit with digital indication on seven segment LED display for any fault like over load, high voltage, low voltage, dry running single crimped, electronic star delta timer, feather touch start / stop push buttons to be erected on angle iron frame. Grouted on wall the contactors will be of L& T, Siemens, BCH make only) (i) 5 HP
Supplying & erecting approved make motor control cubical panel [Star delta] made from 16G CRCA sheet duly epoxy powder painted inside and outside with hinged doors and locking with suitable size of ON - OFF isolator (AC 3 / 23 duty) main fuses. Digital volt and current meter (in a single unit) with micro controller based control unit and current sensing single phasing preventer electronic overload protection, over voltage (Programmable) protection and under voltage (Programmable) protection, prod less dry run protection programming facility for setting of all parameter like overload current, high voltage limit, low voltage limit, dry run limit with digital indication on seven segment LED display for any fault like over load, high voltage, low voltage, dry running single crimped, electronic star delta timer, feather touch start / stop push buttons to be erected on angle iron frame. Grouted on wall the contactors will be of L& T, Siemens, BCH make only) (ii) 7.5 HP
Supply of Soft Starter (Make-Schneider Electric / L & K, ABB) (i) 300A
Supply of Panelbox 5x3 as directed by Engineer-in-charge.
Supply of CT Relay/Coil (Make-Siemens/Schneider Electric / Panasonic) (i) 100x5A
(iii) 200x5A
Supply of Chemical Earthing and normal earthing include all material (As directed by engineer-in-charge).
Supply of Earthing Channel or Patti with all asscessories (i) Material Copper , 25mm width, 6 mm thickness
(ii) Material Aluminmum25mm width, 6 mm thickness
Supplying Knife / Blade / DIN type HRC fuse link capable to withstand 80 K.A. confirms to I.S. 13703 for following current capacity (i) 150 A
Supply of Digital Meggar - Over-voltage detection and warning, High voltage warning indicator, Portability, Durability [Make-Meggar)
Supply of Drill machine - 2600RPM, Chuk capacity 1 to 13mm Spinder collar dia of 43mm. Multiple used- Heavy Duty [Make-Bosch, DEWALT, and Makita)
Supply of Hot gun machine- Temperature setting 60 to 550 C, Heat Setting verible - Multiple used- Heavy Duty (Make-Bosch, Stanley, BlackDecker, Weldy, and Dewalt]
Supply of Voltmeter, Ammeter and PF with display- Dual color LED display for DC, Refresh Rate 300MS per time. As per panel specification(Make- Schneider Electric, ABB, Siemens)
Supply of Indication lamp with socket R,Y & B - Set (Make-Schneider Electric, ABB, Siemens) 1) Often rated IP40 for the enclosure and IP65 for the front of the panel, providing protection against solid objects and water splashes. 2) Modern LED indicators often conform to IEC standards like IEC/EN 60947-5-1, which covers control circuit devices.
Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 50 K.A. and above at 415 V having normal current rating up to 630A. with variable thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing (As instructed by engineer-in-charge)
Pproviding and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 25 KA. at 415 V,having normal current rating up to 25 A to 100A. with Fixed thermal & magnetic release suitable to work on A.C. supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing. (As instructed by engineer-in-charge)
Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 V. having normal current rating 125A. with Fixed thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing. (As instructed by engineer-in-charge)
Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 V. having Normal current rating 200A.with variable Thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S.housing. (As instructed by engineer-in-charge)
Supply of MS Cable glande plate (As directed by Engineer-in-charge)
Supply of Cable tray FRP (As directed by Engineer-in-charge)
Supply of Cable glande (Make-Brass, PG & DC)
Supply of MS angle - 50mm dia (As directed by Engineer-in-charge)
Supply of Panel cooling Fan - PWM control, Alarms, Environmental resistance (As directed by Engineer-in-charge)
Supply of Panel filter (As directed by Engineer-in-charge)
Supply of Cable duck (As directed by Engineer-in-charge)
Supply of Basic Electrical tool kit incl. Tester,screw driver, cutter, etc. Complete Set (As directed by Engineer-in-charge)
Supply of Ratchet spanner set (Make-Taparia, Bosch, Stanley, Gear Wrench, Agrico Tata)
Supply of Hot Sleeve black color
Supply of Hydraulic Crimping Tool for Lugs (As directed by Engineer-in-charge)
Supply of Cutter & Grindre machine(As directed by Engineer-in-charge)
Supply of Hacksaw with frame (Make-Taparia, Bosch, Stanley)
Supply of Air Blower (Make-Bosch)
Supply of Screw fitting machine (Make-Bosch)
Supply of spiral sleeve - 3 to 25 mm (As directed by Engineer-in-charge)
Supply of Tree cutter machine (Make-Honda)
Supply of Portable Welding machine (As directed by Engineer-in-charge)
Supply of capacitor bank for controlling Power factor.(Make-ABB, DCH Electric ltd., Power logic) (i) 10 kvar
(ii) 12.5 Kvar
(iii) 15 kvar
(iv) 20 kvar
(v) 25 kvar
Design, Supplying, installing, testing of factory fabricated ready made Three phase APFC Panel Cubical Panel fabrication should be type tested as per IEC 61921, 61439:1&2 Capacitor Duty Contactor for switching as per following Steps Incomer Switch of MCCB type Icu=Ics=50KA at 400/440 Volts, with OC, SC, internal earth fault protection Incomer Switch of MCCB type Icu=Ics=50KA at 400/440 Volts, with OC, SC, internal earth fault protection,Copper tinned insulated Busbar,Cubical panel should be indoor type with IP 43 and IK 10,Metalized polypropylene film tye3-phase 550Volt Capacitor,De tuning Reactor for each capacitor,Panel having Short Circuit and Overload protection,Each step Capacitor having suitable MCB with Sc, OL, internal earth fault relay,Each stage having Stage Contactor (Capacitor load rating),PF regulator master controller having suitable steps with LCD display, Rs 485 Communication port, Indication LED Lamps for main incomer and ON-OFF for each capacitor bank,MS Chanel for Floor mounting, Cable entry as per site situation,Cooling fans for panel. (i) 25 HP
(iii) 40 to 55 HP
(iv) 60 to 80HP
Design, Supplying, installing, testing of factory fabricated ready made Three phase APFC Panel Cubical Panel fabrication should be type tested as per IEC 61921, 61439:1&2 Capacitor Duty Contactor for switching as per following Steps Incomer Switch of MCCB type Icu=Ics=50KA at 400/440 Volts, with OC, SC, internal earth fault protection Incomer Switch of MCCB type Icu=Ics=50KA at 400/440 Volts, with OC, SC, internal earth fault protection,Copper tinned insulated Busbar,Cubical panel should be indoor type with IP 43 and IK 10,Metalized polypropylene film tye3-phase 550Volt Capacitor,De tuning Reactor for each capacitor,Panel having Short Circuit and Overload protection,Each step Capacitor having suitable MCB with Sc, OL, internal earth fault relay,Each stage having Stage Contactor (Capacitor load rating),PF regulator master controller having suitable steps with LCD display, Rs 485 Communication port, Indication LED Lamps for main incomer and ON-OFF for each capacitor bank,MS Chanel for Floor mounting, Cable entry as per site situation,Cooling fans for panel. (v) 100 to 125 HP
(vi)150 to 175 HP
Supply of Soldering machine and Iron with solder wire. Suitable for all type of Soldering (As directed by Engineer-in-charge)
Supply of Digital/Anlog Electric fault Detector (Non - contact voltage magnetic field detector) [Make-Meggar)
Supply of Busbar panel (As directed by Engineer-in-charge) (i) 63A
Providing and erecting busbar chamber confirming to IS-375 fabricated from 16 G.M.S. sheet, dust & vermin proof having hinged door with rubber gasket and necessary busbar supports with COPPER busbar having current density not more than 1.6 Amp. / sq.mm (Rated current / cross section area) duly wrapped with colour insulation tape for phase sequence, three phase & neutral each suitable for following current capacity with necessary painting mounted on wall or pedestal frame of required size with necessary connections.(As directed by Engineer-in-charge) 300 Amp.
Supply of Highmast Panel (As directed by Engineer-in-charge)
Supply of Highmast 5 HP Motor with all accessaries for lifting of LED Socket. (As directed by Engineer-in-charge)
Supply of Spare parts for Oil starter (Make-Jyoti, ABB, Siemen) (i) Relay 1) 12-20A
(ii) Timer
(iii) Magnetic coil 2 contact
(iv) Magnetic coil 4 contact
(v) Base plate
(vi) ON/OFF switch
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
technical_8066.pdf
techsummary_8066.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.66 MB
BOQ_8066.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid