Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹14.3 L+₹35,038 (2.51%)Rejected-Finance | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹14.5 L+₹52,521 (3.76%)Rejected-Finance | L3 | Rejected-Finance L1 being accepted | |
| 4 | L4₹14.7 L+₹68,246.50 (4.88%)Rejected-Finance 10TH MILE RISHI ROAD KALIMPONG DISTRICT DARJEELING PIN 734301 | KALIMPONG | DARJEELING | WEST BENGAL | 734301 | L4 | Rejected-Finance L1 being accepted | |
| 5 | L5₹14.8 L+₹78,886 (5.64%)Rejected-Finance 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400 708 | THANE | MAHARASHTRA | 400708 | L5 | Rejected-Finance L1 being accepted |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
18 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 867 EWS
GE 867 EWS C/O 99 APO PIN 913867
SPL REPAIRS TO EXTERNAL ELECTRIC SUPPLY SYSTEM AND ALLIED WORKS AT RHENOCK UNDER GE 867 EWS
2021_MES_464362_4
CA NO GE / 867 / TOKEN / 35 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Rhenock
Refer tender documents
8 documents required · 8 mandatory
₹500
GE 867 EWS
₹28,000
Yes
27 Oct 2021
4 Oct 2021
19 Oct 2021
4 Oct 2021
18 Oct 2021
13 Oct 2021
4 Oct 2021 - 9 Oct 2021
60 days
Amount
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, laying of pipe, cable etc., or for shafts, wells, cesspits, manholes, pier holes, etc., not exceeding 10 sqm on plan and getting out in soft/loose soil all as specified and directed by Engineer-in-charge.
Excavating in trenches, not exceeding 1.5m wide and exceeding 1.5m and not exceeding 3.0 m in depth; for foundation, laying of pipe, cable etc., or for shafts, wells, cesspits, manholes, pier holes, etc., not exceeding 10 sqm on plan and getting out in soft/loose soil all as specified and directed by Engineer-in-charge.
Supply and spreading of dry sand in trenches for cable coushioning and punned down complete all as specified and directed by Engineer-in-Charge. Note:- Punned thickness only shall be measured for payment purpose.
M&L for common burnt bricks, sub class 'B', of size 250 x 125 x 75 mm laid in trenches for cable protection complete all as specified and directed by Engineer-in-charge.
Returning, filling in soil, including spreading leveling, watering and wall ramming in laying not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil to a distance n.exe 50m and depositing where directed at alevel n.exe 1.5m above the starting point complete all as directed by Engineer - in -Charge.
M&L for Plain cement concrete 1:3:6 mix type C2 (using 40 mm graded stone aggregate) in foundations, filling and mass-concrete etc., all as specified and directed by Engineer-in-Charge.
M & L Plain cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in coping including necessary formwork, weathering, slightly rounded or chamfered angles, finishing of exposed surfaces of concrete to even and smooth without using extra cement all as specified and directed by Engr-in-charge.
Earhing complete with galvanized steel earth plate electrode 600X600X6 mm buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to GI earth strip of size 32x6mm, by means of galvanized iron or steel bolts, nuts, check nuts and washers, and conneced to equipments as directed, including funnel with GI med grade watering pipe 20 mm bore, wire mesh charcoal or coke and common salt in alternate layers, of 15 cm compacted thickness all around the earth electrode, with concrete pit in PCC 1:3:6 type C-1 , 50 mm thick pre cast RCC 1:2:4 type B1 cover slab reinforced with 8 mm dia reinforced bar 15 cm C/C and suitable handle of 10 mm dia round bar, 40 mm GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I including taking out existing earth plate etc., complete all as specified and as directed by Engineer-in-Charge. NOTE: Rate quoted shall be deemed to include for earth lead and protection pipe upto 7.5m.
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6.3 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI earth lead wire 4 mm dia. by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI medium grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC 1:3:6 type C-1 , 50 mm thick pre cast RCC 1 : 2 : 4 type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar, 15 mm GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I including taking out existing earth plate etc., complete all as specified and as directed by Engineer-in-Charge. NOTE: Rate quoted shall be deemed to include for earth lead and protection pipe upto 7.5m.
S&F aluminium strip 25 x 3.15 mm thick saddle/mounted on porcelain/wooden insulator etc. for roof conductors and down conductors above ground including removing unserviceable conductor complete all as directed by Engineer-in-Charge.
Taking down existing cross arms , bracings, supports, clamps and back plate fabricated from structural sections including nuts, bolts, and washer and refixing in same location or in new location and painting with one coat of aluminum paint including preparation of surfaces, complete all as specified and directed by the Enginee-in-Charge.
Supply & fixing LED street Light in aluminum PDC housing toughened glass cover with IP 66 protection of 60 Watt including lamp fixed toexisting bracket including electrical connection complete with 2 runs of 2.5 Sqmm single core copper cable ISI marked stranded to LT terminal box to fitting fixed with and including GI pipe bracket made out of 40mm dia GI pipe (light grade of length 1.5 meter) bent to the required shape for holding the fitting with proper angle including providing two pair of MS flat iron clamps of size 40mm x 6mm of required length duly drilled for bolt holes with required nuts, bolts and washers of suitable size, including applying two coats of aluminium paint over a coat of red oxide primer to clamps after perparation of surfaces complete including taking down existing fitting all as specified and as directed. Make: SURYA cat part No. SLE UL 60W IP66 LXN or equivalent make of Havells/Philips/CG as approved by GE.
Dismantling of insulators any type any size from existing poles complete all as specified and directed by Engineer-in-Charge.
Dismantling of unserviceable ACSR conductor of any type and size from existing poles at various locations complete all as specified and directed by Engineer-in-Charge.
Dismantling of cross arms (Clamp, nut bolts ) from existing poles at various locations complete all as specified and directed by Engineer-in-Charge.
Taking out stay assembly at various locations complete all as specified and directed by Engineer-in-Charge.
Supply and laying in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sqmm 3.5 core and connecting with necessary lugs complete all as specified and directed by Engineer-in-Charge.
Supply and laying in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core and connecting with necessary lugs complete all as specified and directed by Engineer-in-Charge.
Supply and laying in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core and connecting with necessary lugs complete all as specified and directed by Engineer-in-Charge.
Supply and laying in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 4 core and connecting with necessary lugs complete all as specified and directed by Engineer-in-Charge.
Supply and laying in trenches, fixed to wall or drawn through pipe etc., XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 2 core and connecting with necessary lugs complete all as specified and directed by Engineer-in-Charge. Note for Item No. 18 to 22:- Excavation, earth work, brick protection, protection pipe and sand coushioning shall be measured and paid separately. Make of cable shall be CCI / Gloster / ICC / Unistar / NICCO / Asian (RPG) / Havells / Polycab/PRG/Universal/Plaza/Crystal cables/Terracom/ Rallison/Mescab/Jeypore/KEI
Supply, installing, testing and commissioning factory made LT feeder pillar box (KIOSK) outdoor type platform mounted, CPRI approved suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 mm CRCA steel sheet with double door shutter and locking arrangement, openable from front & back both including powder coated on both outer and inner surfaces for panel. The TPN copper bus bar of rating not less than the 1.5 times the rated capacity of the incommer MCCB including 50 x 50 x 6mm thick angle iron frame workupto height of 0.9mtr above ground level (duly painted with one coat red oxide and one coat of bitumen paint on exposed surfaces) with and including following spares and including dismantling of old unserviceable existing panel all as specified and as directed by Engr-in-Charge. (i) MCCB 4 pole 25 kA 160 Amp - 01 No (Incommer) (ii) MCCB 4 pole 16 kA 63 Amp - 03 Nos. (Out going) (iii) Phase indiacting lamps (R-Y-B) - 01 set (iv) Internal wiring with PVC insulated, multi stranded copper conductor cable, 1100 V grade. (v) Multifunctioning meter with necessary CTs (vi) Spare compartment for MCCB for future expansion - 01 No Make of MCCB: LEGRAND/SIEMENS/SCHNEIDER/L&T
Supply, installing, testing and commissioning busbar box outdoor type of size (L=0.6m, W-0.4m, H- 0.8m) platform mounted, CPRI approved suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 mm CRCA steel sheet with double door shutter and locking arrangement, openable from front & back both including powder coated on both outer and inner surfaces for panel. The TPN copper bus bar of rating not less than the 1.5 times the rated capacity of the incommer MCCB including 50 x 50 x 6mm thick angle iron frame workupto height of 0.9mtr above ground level (duly painted with one coat red oxide and one coat of bitumen paint on exposed surfaces) with and including following spares and including dismantling of old unserviceable existing panel all as specified and as directed by Engr-in-Charge. (i) MCCB 4 pole 16 kA 63 Amp - 01No. (ii) Phase indiacting lamps (R-Y-B) - 01 set Make of MCCB: LEGRAND/SIEMENS/SCHNEIDER/L&T
Material and labour for 40 mm dia bore GI tubing Light grade, laid under roads/ floor, or fixed to wall or along the pole with suitable size M.S.flat iron clamps, nuts, bolts and washers for cable protection including taking down/out existing pipe complete all as specified and directed by Egineer-in-Charge.
Material and labour for 25 mm dia bore GI tubing Light grade, laid under roads/ floor, or fixed to wall or along the pole with suitable size M.S.flat iron clamps, nuts, bolts and washers for cable protection including taking down/out existing pipe complete all as specified and directed by Egineer-in-Charge. Make for iItem No. 25&26: TATA/ZENITH/JINDAL
S&F Busbar Chambers 8 way 200 Amps outdoor type (IP 65/66) including provision of fixing on 50 x 50 x 6mm thick angle iron frame work upto height of 0.9mtr above ground level (duly painted with one coat red oxide and one coat of bitumen paint on exposed surfaces) by means of suitable size of clamps with nut and bolts including necessary PCC Work and connection including taking down existing chamber complete all as specified and as directed. Make Havells cat part No IHBC020008 or equivalent make of SMC/Hencel
M & L for DK Thermoplastic cable junction boxes IP 65 of size 185x165x60mm of metric knockouts for cable entry, weather proof for indoor/outdoor installation with and including glands and with 4 terminals for terminating one incoming and outgoing UG cable of size 10/16 sqmm 2/4 core and fixed to wall/Steel Poles by means of suitable size of clamps with nut and bolts complete including taking down existing existing junction box all as specified and directed by Engineer-in-Charge. Make: Junction box shall be Sintex/Hensel or equivalent as approved by GE
Sub Total of Schedule 'A'
Schedule of Credit (Minus) Rs. 62,660.00 B/F from Ser page No. 26 NOTE: Bidder shall insert credit amount as rate Rs. 62,660.00 in Green field under Col-M. If bidder does not insert the amount the same will be deducted from total amount of Schedule 'A' and accordingly total amount of tender will be considered in deciding the lowest tender.
Sub Total of Schedule of Credit
SANJAY SAW MILL
DEEP CHANDRA JOSHI
GARGO TRADERS
S K ENTERPRISES
JAYSHREE CONCERN
HEM RAJ GURUNG
SANJAY MITTAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .