Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.8 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹40.0 L+₹19,287.10 (0.48%)Rejected-Finance NEAR RANGE OFFICE CHOUBYANA TALBEHAT DISTT LALITPUR UP | TALBEHAT | LALITPUR | UP | L2 | Rejected-Finance not become lowest bidder | |
| 3 | L3₹40.3 L+₹46,581.70 (1.17%)Rejected-Finance 1001 1 AB CIVIL LINES JHANSI 284 001 UP | JHANSI | UTTAR PRADESH | 284001 | L3 | Rejected-Finance not become lowest bidder | |
| 4 | L4₹40.4 L+₹61,046.20 (1.53%)Rejected-Finance | L4 | Rejected-Finance not become lowest bidder | |
| 5 | L5₹40.5 L+₹72,214 (1.81%)Rejected-Finance WARD NO 4 NEAR MASZID BHATTAGAON DISTT JHANSI 284001 UTTAR PRADESH | JHANSI | UTTAR PRADESH | 284001 | L5 | Rejected-Finance not become lowest bidder |
Tender Value
₹41.9 L
EMD Value
₹83,720
Closing Date
20 Jul 2022, 6:00 pmClosed
Major Deepak Kumar
Garrison Engineer Jhansi
PROVN OF SHED FOR 06 X 50 TON TRAILER AT 21 CORPS ZONE WKSP AND CERTAIN OTHER SANCTIONED WORKS UNDER AGE B/R-II AT GE JHANSI
2022_MES_531466_1
GE/JHA/TOK/21 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
GE Jhansi
Please refer tender documents
7 documents required · 7 mandatory
₹500
Yes
GE Jhansi
₹83,720
Yes
6 Oct 2022
16 Jun 2022
22 Jul 2022
16 Jun 2022
20 Jul 2022
29 Jun 2022
Amount
Excavating in post holes (or similar holes) each n.exc 0.5cu m, getting out,returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding, 25cm watering and removing surplus soil to a distance n exc 50m and making good surface in soft/loose soil.
Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth for foundation, etc or for the shafts, well, cesspits, manholes, pier holes, etc n exc 10 Sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil.
M&L PCC 1:4:8, type D2, using 40 mm graded stone aggregate as in foundation filling and mass concrete for fixing Poles, posts complete all as specified and as directed
S & F mild steel work in tubular trusses (either circular or square)including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade Fe 410-W(Gde- E-250) complete all as specified and directed by Engineer-in-charge
S&F of Structural steel for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, Fe-410-W(Gde-E-250) quality-B, complete all as specified and directed.
M&L for preparation of newly steel or iron surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over and including a coat of red oxide primer complete all as specified and directed
M&L for MS work as in wind ties for roof including securing bolts necessary drilling , bolting etc complete all as specified and directed
S&F of pre-painted 0.50mm thick Gavalume Aluminium Zinc coating GI based corrugated / semi corrugated / trapezoidal steel sheet of any colour having tensile strength 550 MPa and AZ 150 grade as in roof covering/cladding to walls, fixed with self tapping screws, complete all as specified and directed. Make : Jindal / Tata / Everest
S&F pre-painted Galvalume Aluminium Zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength 550 MPa and AZ 150 grade as in ridge of roof covering, fixed with self tapping screws, complete all as specified and directed. Make : Jindal / Tata / Everest
M&L for MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment, Fe-410-W (Gde-E-250) quality-B, complete all as specified and directed.
M&L for brick work with Sub class B bricks, straight or curved on plan exc. 6 M mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for 15 mm thick rendering in CM (1:6) on fair/other than fair faces of brick work finished even and fair complete all as specified and directed.
M&L for preparation of new plastered surface and preparation of surfaces of walls by scrapping/sand preparing / rubbing and finally washing with watering and applying a coats of exterior emulsion acyrlic weather proof antifungal paint over a coat of cement base primer (Make -Asian Apex, Berger)
Surface exacavtion n. exc 30 cm deep and avg 15 cm deep and getting out in any type of soil complete all as spd
M&L providing RCC (Norminal Mix), type B1 1:2:4 (using 20mm graded aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns etc; basement slabs, under reamed piles and mass concrete.
Removing of excavated materials to a distance not exceeding 50 M and deposing where directed at a level not exceeding 1.5 M above the starting point
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil
M&L Hardcore (Broken stone) of guage exc 63mm but n exc. deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as spd
M& L 75 mm thick cement concrete type D-2 1:4:8 (using 40 mm garded stone agg) in sub base of flooring/ hard standing complete all as spd and directed by engr-in-charge
M&L 75 mm PCC type B-0, 1:2:4 (12.50 mm graded aggregate) as in floor hardstanding finished even and smooth without using extra cement complete all as spd and directed
M&L 20 mm for Wearproof topping as specified (incorporating an approved metallic floor hardner), laid on concrete floors and pavings, and finished even and smooth (incl metallic hardner) complete all as spd and directed
S/F framed work as in doors or gates of angle or other section with gusset plate, rails, braces etc and fixed complete conforming to Gde Fe 290(Gde-E-165).
S&F 1.25 mm thick Mild steel, plain black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required
S&F of 1.60 mm thick Mild steel, plain, black sheet in hearths; covering to door shutters; covering to door chowkats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required
M&L for cement concrete type B-1, 1:2:4 using 20 mm graded stone aggregate as in coping complete all as specified and as directed.
Formwork to sides of pillars, posts struts piers, columns and stanchions
Spreading and leveling of soft/loose soil in floor in layers n exc. 25 cm thick including well ramming watering as required.
M&L 25 mm thick cement concrete in flooring type Bo, 1:2:4 (12.5mm graded aggregate)
M&L for 75mm thick cement concrete (1:3:6) type C-2 using 40mm graded stone agg finished even & smooth without using extra cement as in plinth protection including forming joint to full depth of 3 mm thick at every 3.0 m interval complete all as specified and directed.
Form work to flat soffits of suspended slabs such as roof slabs, floor slabs and lintels, landingand similar work n exc 200mm thick.
Use & waste of form work to sides of concrete foundation, footings, bases of columns, rafts and raft beamsand similar work; vertical or to batter for rough finished surfaces of concrete, complete all as specified & directed.
M & L Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
Mild steel TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
M/L providing RCC (Nominal Mix) M-25 ( using 20 mm graeded aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like
M/L providing RCC (Nominal Mix) M-25 ( using 20 mm graeded aggregate as in columns, pillars, piers, post and struts
M/L providing RCC (Nominal Mix) M-25 ( using 20 mm graeded aggregate as in beams cantilevers, lintel etc
Rendering 10 mm thick on fair faces of concrete surfaces in cement mortar 1:6 for finished even and smooth without using extra cement
M&L Rendering in two layer on fair faces of brick work or concrete surfaces of wall 5 mm thick in CM 1:4 mixed with WPC @ 3% by wt of cement for finished even and smooth without using extra cement over 10 mm thick rendering in cement mortar 1:6 (WPC will be measured and paid separately). smooth without using extra cement.(WPC will be measured separately)
Supply only liquid water proofing compound
Preparing newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
Preparing newly plastered surfaces of ceilings and applying three coats of white wash complete all as specified and directed.
M&L for factory made PU coated, machine pressed precast concrete interlocking paver block of any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with coloured pigment, made of PVC moulded (or rubber mould) with vibrating system laid over 50 mm thick sand cushion, with and incl CM (1:3) in edges of pavers, complete all as specified and directed. Note : The cost of sand cushion is included in quoted rate
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels cantilevers shelves including supports, overhangs etc also splays between floors and beams etc
M&L for providing precast cement concrete louvres and jallies type B0 1:2:4 (12.5mm graded aggregate) 25mm thick (measured solid) including all mouldings but excluding frame set in cement mortar 1:4 complete all as specified and directed.
S&F 110mm PVC SWR pipe single socketed in any length with rubber ring joints laid in trenches or in floor
Supply and fix MCB distribution board, TPN, 4 way 415 Volt in sheet steel powder painted enclosure double door type with IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed. Note: MCBs shall be measured and paid separately.
Supply and fix MCB distribution board, SPN, 8 way 230 Volt in sheet steel powder painted enclosure double door type with IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge. Note: MCBs shall be measured and paid separetely.
Supply and fix MCB TPN 63 Amp, 10 KA, 'C' curve, 415 V, 50 Hz
S& F MCB TP 32 Amp, 10 KA, 'C' curve, 230 V, 50 Hz
S& F MCB SPN 32 Amp, 10 KA, 'C' curve, 230 V, 50 Hz
S& F MCB SP 6- 32 Amp, 10 KA, 'C' curve, 230 V, 50 Hz
Supply and fix Industrial wall mounted plug and socket 32 Amps rating 3P+N suitable for IP44 in sheet steel enclosure with 4 pole MCB 32A 415 V, 50 Hz complete all as specified and directed.
Supply and fix modular MCB protected plug and socket board in sheet steel enclosure with one number 20 A rated mini MCB TP and 20 A rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board and making good with cement plaster, putty and paint to match with the existing surface or fixing on structural steel surface all as specified and directed.
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and all as specified and directed by Engineer-in-Charge.
Supply and fix LED street/security light fitting 60 watts with high efficiency long life LEDs with In-built electronic driver complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP66 degree of protection including GI pipe bracket made up of 25mm dia medium grade GI pipe of length 1.50m bent to required shape and fixing on walls with suitable MS clamps(02Nos) made up of 25mmx4mm MS flat, nuts, bolts and washers and provision of 3 core twisted flexible copper cable of size 0.5 sqmm from ceiling rose to connector of fitting complete all as specified and as directed.
Supply & fix Air Circulator fans 230 volts single phase oscillating 600 mm sweep suitable for wall mounting incl taking down existing u/s ceiling fans and deposited to E&M store yard complete all as specified and directed.
M&L for Circuit/submain wiring alongwith earth wire 2 runs x 4 sqmm + 1 run x 4 sqmm with FRLS insulated copper conductor, single core cable drawn through and including in steel conduit and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ on floor etc complete all as specified and directed by Engineer-in-Charge. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length
All as per srl item no. 57.00 here-in-before but 2runsX2.5 Sqmm +1runX2.5Sqmm.
All as per srl item no. 57.00 here-in-before but 2runs1.5 Sqmm +1runX1.5 Sqmm.
Material and labour for earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to GI wire 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by 15mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion including removing of existing earthing complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth wire up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II.
Supply, laying, testing & commissioning of Power Cables, Aluminum Stranded Conductor 95 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V grade as per IS 7098(Part 1) 1988 complete laid in trenches / floors / fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings and testing on completion all as specified and directed. Note: Excavation, earth work and provn of cable covers / protection pipe etc shall be measured and paid separately under relevant items of BOQ.
All as per item No. 61 here-in-before but of size 50 sqmm, 3.5 core
All as per item No. 61 here-in-before but of size 25 sqmm, 4 core
All as per item No. 61 here-in-before but of size 16 sqmm, 4 core
All as per item No. 61 here-in-before but of size 16 sqmm, 2 core
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting out in any type of soil for laying of cables/ for erection of poles/ for stay assembly etc complete all as specified and directed.
Supply and spread M-sand in trenches for cushioning of cable / in the yard of outdoor substations complete all as specified and directed. (Note: Punned down thickness only shall be measured for the purpose of payment)
Returning, filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed.
Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point.
Supplying and laying in replacement of un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm for cable protection in trenches complete all as specified and directed.
M&L for cutting of existing road / hard standing up to 15 cm depth for laying of pipe lines and making good the disturbed surfaces by providing PCC 1:2:4 type B-1 (using 20mm graded aggregate) after laying of pipes lines / cables and returning filling of soil, complete all as specified and directed. Note:- Excavation and earth work below road / hard standing will be measured and paid under relevant items.
Supply and fixing of 80mm dia bore tubes, 'light grade' galvanized, with all fitting and fixed complete to walls/ poles or laid in trenches/ floors for cable protection complete all as specified and directed.
Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed by Engineer-in-Charge.
Design, Fabricate, Supply, Installation, Testing & Commissioning of intdoor type dust proof & vermin proof cubical panel board compartmentalized with separate bus bar and cable alley chambers suitable for 3 phase, 4 wire, 415 volts, 50 Hz, Ac supply system as per latest IS/IEC standards & regulations, factory fabricated in an approved factory (manufacturer possessing CPRI test report for equivalent ratings) having modern fabrication facilities, made out of CRCA sheet steel of 2.00mm thick for outer shell and 2mm thick for inner shell with front and rear openable double leaf doors with two point locking arrangement i.e. locking system with handle up & down arrangement & pad locking facility. Complete panel board shall be applied with powder coat painting of approved shade duly pretreated with seven tank process and suitable packing material for IP-54 degree of protection and including provision of 50mm x 50mm x 6mm angle iron base frame of suitable size for mounting the panel board with a minimum ground clearance of 450mm above GL to the bottom of panel including PCC foundation with PCC 1:3:6, type C2 using 40mm graded stone aggregate. Detachable gland plates including double compression stainless steel cable glands of suitable size shall be provided for all incoming and outgoing cables. Steel plate Danger Notice Boards (02 Nos) LT 415/440 Volts, and manufacturer's name plate shall be riveted on external doors of feeder pillar box. The size of panel board shall not be less than 1500mm x 1300mm x 450mm (outer dimensions) for accommodating and including provision of following switchgear, control gear and accessories including internal wiring using copper flexibles and lugs of suitable grade/capacity complete all as specified and directed :- (Near Prop Trailer Shed)
M&L for earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connecting to GI strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by 50mm dia GI pipe medium grade and connected to pole structure/ panel board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth strip up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II
Supply and erection of Hot dip galvanized tapered octagonal pole of height 7.0 mtrs in single or double section having top dia 70mm and bottom dia 130mm made up of 3mm thick sheet and welded with a base plate of size 200mm x 200mm x 12mm thick and provided with 1000mm long single arm bracket with 15 degree of angle for mounting street light fitting complete with provision of 04 Nos of ‘J’ type foundation bolts of size not less than 20mm dia, 600mm long embedded in RCC foundation concrete as per manufacturer’s recommendation including necessary earth work, RFR etc complete. A door should be provided at a height of 500mm from the base plate for accommodating and including provision of TPN aluminium bus bar system suitable for connecting up to 4 core, 16 sqmm aluminium cable and 01 No. of 6A SP MCB for street light protection inside the pole shaft including provision of 3 core, 1.50 sqmm PVC insulated PVC sheathed copper conductor cable 1100 volts grade confirming to IS:694 from pole junction box to street light fitting drawn through inside of pole . Radium reflector band / strips of 5cm wide in Green (02 Nos) & White (01 No.) colour shall be provided at a height of 1.25mtr from base plate. Numbering of pole shall be done in black colour on yellow background at suitable place on the pole complete as specified and directed. Note: The quoted rate shall deemed to be inclusive of RCC foundation concrete, necessary excavation, erth work & RFR etc complete as per manufacturer's recommendation. Contractor shall submit the pole drawing and foundation drawing as per manufacturer's recommendation for approval of GE before procurement.
M&L of cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
M&L for Shackle type, porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, insulator bolts, washers and nuts for working pressure 1100 Volts grade, height 75mm, dia 90mm complete all as specified and directed by Engineer-in-Charge.
M&L for Pin type, porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, insulator bolts, washers and nuts for working pressure 1100 Volts grade, height 100mm, dia 65mm complete all as specified and directed by Engineer-in-Charge.
Supply and fix of Loop type insulator, vitreous porcelain, white, brown or green Small size, with overall dimensions 65 x 90mm, clearance of hole 16mm complete all as specified and directed by Engineer-in-Charge.
Supply and fix of Stay assembly with 16mm dia stay rod and all accessories as shown in electrical plate No. 1 complete all as specified and directed by Engineer-in-Charge. Note: Loop type insulator, stay clamps, stay wire, excavation and concrete measured separately)
Supply and fix of Galvanized stay strand, 7/3.15mm including proper tightening to required tension complete all as specified and directed by Engineer-in-Charge.
Supply and fix of ACSR conductor for HT/LT overhead line and proper stringing to required tension and sag including binding with new aluminium binding wire of suitable size complete all as specified and directed by Engineer-in-Charge.
M&L for dismantling of steel poles/struts of any size complete all as specified and as directed.
M&L for dismantling of ACSR conductor or AAC conductors of any size complete all as specified and as directed.
M&L for dismantling of cross arms of MS channel or angle sections etc complete all as specified and as directed.
M&L for dismantling of insulators of any type and any size etc complete all as specified and as directed.
M/S RAJ CONSTRUCTION AND ELECTRICAL
M/S NASIM AND CO.
M/s P L Dixit
M/s JS Constructions
ARTISTIC BUILD CO
M/S S K AGARWAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .