Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.2 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹33.3 L+₹3.3 L (11.0%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹35.8 L+₹5.8 L (19.5%)Rejected-Finance SCHEME NO 07 BLOCK NO 22 FLAT NO 03 NEW GURDASPUR DISTT GURDASPUR PB 143521 | GURDASPUR | PUNJAB | 143521 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹37.7 L+₹7.7 L (25.7%)Rejected-Finance 99 MODEL TOWN PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹43.3 L+₹13.3 L (44.5%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
4 Jun 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer, Gurdaspur.
Garrison Engineer, Gurdaspur (Tibri)
Repair/ replacement of LT over head and under ground cable and connected items at outstation and amenities under GE Gurdaspur.
2025_MES_706859_1
GE GSR-24/2024-2025
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
Garison Engineer
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE Gurdaspur
₹96,000
2 Aug 2025
6 May 2025
11 Jun 2025
6 May 2025
4 Jun 2025
21 May 2025
Amount
Excavation in trenches in soft loose soil including cutting road surfaces n.exc 1.5 mtr wide and n.exc. 1.5 mtr in depth for poles, stay, cable, pipe etc getting out complete all as specified and directed.
All as per item No 1 here-in-before but depth excd 1.5 mtr and n. exc 3 mtr all as specified and direted.
Removal of excavated soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Returning, filling in, including spreading, leveling,watering and well ramming in layers n.exc 25 cm thick in soft loose soil all as specified.
Supply and lay brick common burnt sub class "B" old size (compressive strength not less than 75 kg per sqcm) for protection of cable laid in trenches for under ground cable all as specified.
M&L for sand cushioning in trenches using fine sand to under ground cable, laid in two layers 15cm before laying the cable & 8cm after laying the cable complete all as specified and directed.
S&F in repair for cable protection GI tubing light grade fixed along the pole/wall/under road of size 100 mm bore with necessary clamps, nut and bolts all as specified and directed by Engineer -in-Charge. (Note : Clamps,nut and bolt will be measured and paid separately).
All as per Srl item No 7 here-in-before but size 80mm.
All as per Srl item No 7 here-in-before but size 50mm.
All as per Srl item No 7 here-in-before but size 40mm.
M&L for cross arms in repair , bracing, supports, clamps and brick plates, fabricated from staructural steel section including nut bolts washers, welding, bending , cold or hot drilling holes for bolts of any shape or size as indicated in drawings or as directed, including two coats of aluminium paint over a coat of red oxide all specified.
M&L for aluminium conductor steel reinforced (ACSR) over size of ferret, weasels, mink, beaver etc fixing stretching and jumppering joining with aluminium wire complete all as specified.
Supply and laying in replacement XLPE insulated armoured (under ground) heavy duty electic cable with stranded aluminim conductor 1100 volts grade of crossectional area 300 Sqmm 3.5 core laid in trenches/ducts/through pipes/in floor road/along the pole etc all as specified and directed by Engr-in-charge. (Note : Excavation earth work, brick protection and cushioning shall be measured & paid separately).
All as per srl item No. 13 here-in-before but size 240 Sqmm 3.5 core.
All as per srl item No. 13 here-in-before but size 185 Sqmm 3.5 core
All as per srl item No. 13 here-in-before but Size 150 Sqmm 3.5 core
All as per srl item No. 13 here-in-before but size 120 Sqmm 3.5 core
All as per srl item No. 13 here-in-before but size 95 Sqmm 3.5 core.
All as per srl item No. 13 here-in-before but size 70 Sqmm 3.5 core.
All as per srl item No. 13 here-in-before but size 50 Sqmm 3.5 core.
All as per srl item No. 13 here-in-before but size 35 Sqmm 3.5 core.
All as per srl item No. 13 here-in-before but size 25 Sqmm 4 core.
All as per srl item No. 13 here-in-before but size 16 Sqmm 4 core.
M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation for pole/stay assembly foundation etc all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:3:6 type D-2 (using 40mm graded crushed stone aggregate) as in foundation for pole/stay assembly etc all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) as in coping of poles including necessary form work and fair finish to exposed surfaces complete all as specified and directed.
M&L for stay assembly comprising of 7/3.15 galvanised stranded stay wire of required length, fixed to pole with and including flat iron clamps 50x6mm, bolt, nuts washers, GI stay rod 20 mm dia and 1800 mm long stay bow 400x14 mm, GI steel plate 300x300x6mm, loop insulator of size 90x140mm clearance hole 16 mm including two coats of aluminium paint over a coat of red oxide primer on exposed mild steel work all as shown in Electrical Plate no 1 of SSR part-I 2009 on page No 495 complete all as specified and directed. ( Note : Excavation & PCC works shall be measured and paid separately).
Supply and erecting steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9 metres long).
Supply and erecting vertically prestressed concrete LT pole 9.0 mtr long 102 x 172mm at top and 102mm x 279mm at bottom class 10 all as specified and directed.
S&F shackle type insulator porcelain vitrous white, brown or green insulator incl galvanised mild steel straps washers insulators bolts washers of size 75x90 mm all as specified and directed by Engineer-in-Charge.
M&L for synthetic chequered insulated mat, ISI marked of size 2mx1mx19mm Conforming to IS- 15652 / 2006 all as directed by Engineer-in-Charge.
M&L for earthing complete with galvanised steel earth plate electrode 60cm×60cm×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 25×4mm as earthing lead galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.
M&L for re-stringing/ stretching of existing ACSR conductor of any size any type as required sag fixed on OH line incl unwinding the conductor and insulators/cross arms on poles properly binding with alumminum wire all as specified and directed.
M&L for road cutting including excavation, returning filling in, spreading leveling, well ramming in layers, soiling with broken boudders/ stones, WBM 7.5cm thick coarse aggregate received from dismentling the existing WBM of road, watering and ramming, 40mm thick PCC 1:2:4 (using 20mm graded crushed stone aggregate) for road patch repair work, section/ cross section area of cutting shall be as specified and as directed by Engineer-in-Charge.
S&F cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat Shrink type and accessories suitable for 3½ core XLPE, armoured, aluminium conductor cable of size 240 to 300 sqmm, Indoor/ outdoor type complete all as specified and directed.
All as per Srl item No 35 here-in-before but of size 150 to 185 sqmm.
All as per Srl item No 35 here-in-before but of size 70 to 120 sqmm.
All as per Srl item No 35 here-in-before but of size 25 to 50 sqmm.
S&F LT heat shrinkable type indoor/outdoor end termination cable jointing kit with jointing material and accessories suitable for 1100 volt (Earthed) grade 3½ core XLPE, armoured, Al conductor cable of size 240 to 300 sqmm complete all as specified and directed.
All as per Srl item No 39 here-in-before but of size 150 to 185 sqmm.
S&F alluminium lugs, eye type, suitable for cable size 16 to 25 sqmm including necessary crimping tool complete all as specified and directed .
All as per Srl item No 41 here-in-before but of size 35 sqmm.
All as per Srl item No 41 here-in-before but of size 50 sqmm.
All as per Srl item No 41 here-in-before but of size 70 sqmm.
All as per Srl item No 41 here-in-before but of size 95 sqmm to 120 sqmm.
All as per Srl item No 41 here-in-before but of size 150 sqmm to 185 Sqmm.
All as per Srl item No 41 here-in-before but of size 240 Sqmm.
All as per Srl item No 41 here-in-before but of size 300 Sqmm.
Cutting/trimming of tree branches of any width/ girth up to 3 mtr distance of LT over load lines including collection and depositing the retrived timber at a place as directed by Engr-in-Charge. (Note :- (i) Each span is having a distance 35 mtr approximately. (ii) All cutting branches of tree shall be thrown away at approximately 500-700 mtr away as directed).
M&L for painting to LT steel tublar pole with one coat of aluminium paint complete above ground level including all MS fitting street light brackets of MS flat angle iron GI pipe etc and numbering of poles as marked by existing number with correct size including removing and cleaning of old painted surface all as specified and directed
M&L for painting the PCC pole of 05 Nos bands/ strips of 30cm wide each with two coats of synthetic enamel paint (black and yellow) at a distance of 30cm from the plinth block upto 1500mm height and marking / sign writing of pole number and feeders locations of pole with thick synthetic enamel paint (white) including all MS fitting street light brackets MS flat angle iron GI pipe etc complete all as specified and directed to match the existing poles.
S&F in repair heavy duty PVC spacer for LT 1100 Volt grade suitable for 5 ACSR conductor of size required at site complete all as specified and directed.
S&F in repair heavy duty PVC spacer for LT 1100 Volt grade suitable for 5 ACSR conductor of size required at site complete all as specified and directed.
S&F in repair heavy duty PVC spacer for LT 1100 Volt grade suitable for 3 ACSR conductor of size required at site complete all as specified and directed.
M&L for purning the branches of broken tree any grith on the ACSR conductor LT/HT due to strom or any situation and shal be thrown away approximately 500 mtr away after that jointing and restreching the broken ACSR conductor all as specified and directed by Engineer-in-Charge.
A Schedule of Credit for old/unserviceable demolished/ dismantled items has been catered for in the tender. The Schedule of Credit is pre-priced by MES. The final amount of the tender shall be arrived at after deducting the total amount of Rs. 2,72,821/- Schedule of Credit from the total amount of BoQ as per General Summary sheet catered for after Schedule of Credit.
kailu construction co (BID ID -3307275)
HARPAL ENGINEERS AND BUILDERS (BID ID -3313290)
satpal and brothers (BID ID -3310213)
AGGARWAL ASSOCIATES (BID ID -3306750)
JCC ENGINEERS PRIVATE LIMITED (BID ID -3302045)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .