Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹38.6 L+₹6.2 L (19.3%)Rejected-AOC | L2 | Rejected-AOC OTHER THAN LOWEST | |
| 3 | L3₹41.0 L+₹8.6 L (26.5%)Rejected-AOC 17 KARAMCHARY COLONY UIT ROAD SRI GANGANAGAR RAJASTHAN 335001 | GANGANAGAR | RAJASTHAN | 335001 | L3 | Rejected-AOC OTHER THAN LOWEST | |
| 4 | L4₹42.6 L+₹10.2 L (31.5%)Rejected-AOC | L4 | Rejected-AOC OTHER THAN LOWEST | |
| 5 | L5₹44.7 L+₹12.3 L (38.0%)Rejected-AOC 411 STREET NO 4 PANCHVATI NAGAR BATHINDA 151001 | BATHINDA | PUNJAB | 151001 | L5 | Rejected-AOC OTHER THAN LOWEST |
Tender Value
₹45.4 L
EMD Value
₹90.8 L
Closing Date
12 Jun 2025, 6:00 pmClosed
GE CHANDIGARH
GE CHANDIGARH N AREA OLD AIRPORT CHOWK CHANDIGARH 160003
GE/CHD/T-06/2025-26 SPECIAL REPAIRS TO BLDG NO T-16 AND T-17 AT K AREA UNDER GE CHANDIGARH
2025_MES_706697_1
GE/CHD/T-06/2025-26
Open Tender
Civil Works
Item Rate
180 days
ZIRAKHPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE CHANDIGARH
₹90.8 L
Yes
1 Aug 2025
5 May 2025
14 Jun 2025
5 May 2025
12 Jun 2025
31 May 2025
6 May 2025 - 12 May 2025
Amount
Taking down Cement plaster or cement lime plaster on brick or stone walls including raking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (reinforced) (reinforcement cut as required to facilitate demolition) as in roofs, floors (other than ground floors) beams, slabs, staircases, landing, chajjas and similar suspended work complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames n.exc 1.5 sqm each (without taking off shutter from the frame) and removing from the site including dismantling brick work of hold fasts complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames exc 1.5 sqm but n.exc 4 sqm each (without taking off shutter from the frame) and removing from the site including dismantling brick work of hold fasts etc complete all as specified and directed by Engineer-in-Charge.
Dismantling timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work or stone/boulder masonary built in cement mortar incl all quions arches, pillar or any other descrption etc complete all as specified and directed by Engineer-in-Charge.
Demolition of entire steel (corrugated or plain) sheets in roof coverings etc complete all as specified and directed.
Dismantling wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete, all as specified and as directed by Engr-in-charge.
Demolition of cement concrete of any description and in any position including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge.
Installation of rebar by using Hilti hammer drill with carbide drill bit,chemical dispensing gun for inserting and using injection mortar chemical Fischer 585 s or equivalent upto minimum depth of (10 x dia of bar ) as in chajja,beam,lintel,column slab and parapet at any height before inserting an anchor bar.Hole must be free from dust debris,water,oil grease complete all as per manufacturers instructions. Note :- (i) Reinforcement shall be measured and paid separately. (ii) Rates are inclusive of form work and safety measures. (iii) Dia of bar 10/12 mm (iv) Rates are inclusive of injection mortar chemical
100 mm thick Cement concrete M-25 (Design mix) using 20 mm graded mechanically crushed stone aggregate as in wear resistance tremix flooring by using Vaccum Dewatering method .The floor shall be provided with and inclusive of non metallic floor hardener @ 5 kg per sqm complete all as specified and directed by Engineer-in-Charge.
75 mm thick, cement concrete type C-1, 1:3:6 using 40 mm graded stone aggregate, finished even & smooth without using extra cement, as in plinth protection, complete all as specified.Plinth protection shall be laid in 1:20 slope and joint filling sealed with bituminous sealing compound grade "A" .
75 mm thick cement concrete 1:4:8 type D 2 (40 mm graded mechanically crushed stone aggregate) as in subbase/path finishing concrete surface even and fair complete all as specified and directed.
Reinforced Cement Concrete Design Mix M-25 using 20mm graded mechanically crushed stone aggregate as in Chajjas and the like complete all as specified and directed by Engineer-in-Charge..
Use & waste of formwork to to chullah hoods, chajjas,troughs and similar items including edges etc. (rough finished flat surfaces of concrete), complete all as specified and directed by Engineer-in-Charge.
Use & waste of form work for rough finished surface to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete, all as specified and directed by Engineer-in-Charge.
TMT steel bars 10mm dia and over, of grade Fe-500D cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge.
First quality Non - skid coloured Ceramic tiles 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors etc. set and jointed with 4 mm spacer and grouting the joint of flooring with epoxy grout mix of organic coated filler of desired shade,hardener ,resin in the ratio of 8:1:2 laid over and inculding 15 mm thick screed in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Brick work with sub class 'B' bricks, class designation 100, old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
Rendering 15 mm thick in cement mortar 1:6, on fair faces of brick or concrete surfaces , trowelled to even and smooth surface without using extra cement, complete all as specified and directed by Engineer-in-Charge.
Rendering 15 mm thick in cement mortar 1:4, on other than fair faces of brick or concrete surfaces in two layers (10+ 5) mm mixed with water proofing compound on top layer , trowelled to even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. NOTE: Water proofing compound shall be measured and paid separately.
Preparation of new external surfaces of walls brooming down, applying two coats of cement based paint white or tinted over a coat of primer including properly filling the cracks with putty, etc complete all as specified and directed by Engineer-in-Charge.
Preparation of new plastered surfaces of wall and applying two coats of oil bound distemper on walls over and including a coat of primer and 1 mm wall care puty including preparation of surface complete all as specified and directed.
Preparation of old Plastered of walls etc by brooming down or steel wire brushing, scrapping down smoke soot moulds, moss, efflorescence salts treating oil and greasy spots etc and applying two coats of cement base paint including properly filling the cracks with putty complete all as specified and directed by Engineer-in-Charge.
Preparation of old Plastered of walls etc by brooming down or steel wire brushing, scrapping down smoke soot moulds, moss, efflorescence salts treating oil and greasy spots etc and applying two coats of oil bound distemper on walls complete all as specified and directed by Engineer-in-Charge.
Mortice lock, vertical type, aluminium size 100 mml with 2 levers complete all as specified and directed by Engineer-in-Charge.
Powder coated aluminium (minimum thickness of powder coating 50 micron) aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified as specified and directed by Engineer-in-Charge.
Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per drawings and the directions of Engineer-in-Charge
Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge.
Rolled mild Steel as in Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment etc conforming to Fe 410-W (Gde E- 250) quality A and fixing complete all as as specified and directed by Engineer-in-Charge.
Rolled mild Steel as in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 and fixing complete all as as specified and directed by Engineer-in-Charge.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws,hooks etc complete all as specified and as directed by Engr-in-charge.Colour to be decided by GE
Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws,hooks etc complete all as specified and as directed by Engr-in-charge.Colour to be decided by GE
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with stainless steel wire staples complete all as specified and directed by Engineer-in-Charge.
Sheet glass 4.8 mm thick, ordinary quality and glazing with linseed oil pane putty & spring glazing clips using Silicon for fixing of glass in addition to glazing putty, in squares not exceeding 0.5 Sq. mtr in each pane, complete all as specified and directed by Engineer-in-Charge.
Preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair Mineral Fiber Ceiling Tile 16mm thick with 15mm Grid system interlocking T15 Pro T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’.The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450mm centre to centre & 40 mm long dry wall S.S. screws.Then 16mm thick Impression or equivalent Mineral fiber ceiling panel having FLB edge of size 595x595 shall be placed into the above grid of size 600x600mm. This ceiling panel confirms to ASTM E84 surface burning characteristics (Class A, Flame Spread: 25 & Smoke developed: 50). The Ceiling panel provides NRC: 0.6, CAC minimum: 33, minimum Light Reflectance: 84%, minimum Recycled Content - 45%, Reaction to fire Class 0/Class 1 as per BS 476 Pt - 6 & 7 & can withstand Relative Humidity up to RH 99% (limiting conditions –Max 49°C/99%RH). Contains a broad-spectrum antimicrobial additive on the face and back of the panel that provides resistance against the growth of mold and mild confirming to ASTM D3273 Approved complete all as specified and directed. complete all as specified and as directed by Engr-in-charge.Colour to be decided by GE
INTERNAL ELECTRIC SUPPLY WORKS
Taking down Copper/Aluminium point wiring (light, fan, socket or power) complete, any type / size complete with removing all connection and accessories, fittings and fixtures such as switches , sockets, ceiling rose,pendent holder,fan regulator any type , all type of tube light fitting , batten , steel or PVC conduit , casing caping etc compele and making good the disturbed surface of wall , floor etc. complete all as specified and directed by Engineer-in-Charge. Note :-- Rates for cutting/chases in walls and making good disturbed area deemed to be included in the quoted rate
Taking down existing unserviceable sub main wiring with 2 Runs/4 Runs of 2.5/4/6/10 Sqmm aluminum/copper cable all as directed by Engr-in-charge.
Point wiring using approved colour coding as per IS ,with stranded copper conductor 1.5 sqmm (nominal area ) single core , flame retardant low smoke and low halogen FRLSH PVC insulated unsheathed , 1100 V grade conforming to IS 694 ,marked TEC and FIA approved in and including PVC conduit medium grade ISI marked 20mm dia with all fittings and accessories, concealed type/ surface type (surface type only on ceiling), PVC junction boxes, modular metal sunken/flush boxes of any modules from 2 to 18 Modules with Inner and outer modular cover plates, including FRLSH flame retardant low smoke and low halogen rigid PVC insulated unsheathed stranded copper conductor 1.5 Sqmm (nominal area )single core cable as earth continuity conductor to common earth and connected to earth dolly complete all as specified and directed by Engr-in-charge. Note :- 1. Cutting/chasing of wall etc. deemed to be included in the quoted rate of this item. 2. Modular metal flush/sunken Box along with modular switch/socket cover plate & sheet are inclusive in the item rate quoted. 3. Only switch socket and fan regulators to be measured and paid separately
(a) One light point controlled by one switch or one (Ceiling/ Wall/ Exhaust) fan point controlled by one switch and regulator
(b) One 3 pin 5 Amps socket outlet on independent board
(c ) One 3 pin 5 Amps socket outlet on same board with other switches
Point wiring using approved colour coding as per IS ,with stranded copper conductor 2.5 sqmm (nominal area ) single core , FRLSH flame retardant low smoke and low halogen PVC insulated unsheathed , 1100 V grade conforming to IS 694 ,marked TEC and FIA approved in and including PVC conduit medium grade ISI marked 20mm dia with all fittings and accessories, concealed type/ surface type (surface type only on ceiling), PVC junction boxes, modular metal sunkun/ flush boxs of any modules from 2 to 18 Modules with Inner and outer modular cover plates, including FRLSH flame retardant low smoke and low halogen rigid PVC insulated unsheathed stranded copper conductor 2.5 Sqmm (nominal area )single core cable as earth continuity conductor to common earth and connected to earth dolly complete all as specified and directed by Engr-in-charge. Note :- 1. Cutting/chasing of wall etc. deemed to be included in the quoted rate of this item. 2. Modular metal flush/sunken Box along with modular switch/socket cover plate & sheet are inclusive in the item rate quoted. 3. Only switch, socket and fan regulators to be measured and paid separately
Point wiring using approved colour coding as per IS ,with stranded copper conductor 4 sqmm (nominal area ) single core , FRLSH flame retardant low smoke and low halogen PVC insulated unsheathed , 1100 V grade conforming to IS 694 ,marked TEC and FIA approved in and including PVC conduit medium grade ISI marked 20mm dia with all fittings and accessories, concealed type/ surface type (surface type only on ceiling), PVC junction boxes, modular metal sunkun/ flush boxs of any modules from 2 to 18 Modules with Inner and outer modular cover plates, including FRLSH flame retardant low smoke and low halogen rigid PVC insulated unsheathed stranded copper conductor 4 Sqmm (nominal area )single core cable as earth continuity conductor to common earth and connected to earth dolly complete all as specified and directed by Engr-in-charge. Note :- 1. Cutting/chasing of wall etc. deemed to be included in the quoted rate of this item. 2. Modular metal flush/sunken Box along with modular switch/socket cover plate & sheet are inclusive in the item rate quoted. 3. Only switch, socket and fan regulators to be measured and paid separately
Modular snap Switch one way 6 Amps one module complete all as specified and directed.
Modular snap Switch one way 16 Amps one module complete all as specified and directed.
Modular Socket 6 Amps 5 Pin 2 Module complete all as specified and directed.
Modular Socket 6/16Amps 5 Pin 2 Module complete all as specified and directed.
Modular blanking plate suitable for 1 Module complete all as specified and directed
Modular fan Regulator step electronic type 2 module complete all as specified and directed.
Ceiling rose surface backlite 65 x 20mm size three terminalcomplete all as specified and directed.
Lamp holder, PVC/ Polycarbonate type with back plate with and including one no of LED bulb 15 watt Base-22 retrofit type complete all as specified & directed.
LED lights fitting 1x 20 Watt, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose including 20 watt LED tube rod complete all as specified and directed.
Surface mounted wall mirror LED light 2 feet Compact & sturdy 10 watt LED decorative fixture with anti glare polycarbonate diffuser, multi purpose lighting solution & applications .all accessories & fixtures, internally prewired and connecting by providing copper flexible wire 23/.0076 mm twin core upto fitting, complete all as specified and directed.
10W Bulk head LED luminaries Die cast aluminium alloy body ,heat resistent prismatic glass cover ,with specially designed gasket incl all accessories & fixtures, internally prewired and connecting by provding copper flexible wire 23/.0076 mm twin core upto fitting, complete in all respects complete all as specified and directed by Engineer-in-Charge.
40 watt recessed mounting downlight 2 x2 ft decorative type incl all accessories & fixtures, internally prewired and connecting by provding copper flexible wire 23/.0076 mm twin core upto fitting, complete in all respects complete all as specified and directed by Engineer-in-Charge.
Security Light LED 45 Watt made up of pressure dia cast Alumunium housing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including sevice bracket of GI pipe 32mm bore medium grade of length 0.9 mtr with MS clamps, bolts, nuts, and washers and suitable reducer for connecting fitting to GI pipe as required as site and making electrical connection, complete all as specified and directed.
Sub main wiring using approved colour coding as per IS with two runs of 6 sqmm PVC insulated, unsheathed cable FRLSH, flame retardant low smoke and low halogen 1100 volts grade , ISI marked with multistranded copper conductor with one run of 4 sqmm (green colour) PVC insulated, unsheathed cable FRLSH, flame retardant low smoke and low halogen 1100 volts grade , ISI marked with multistranded copper conductor as earth wire connected to common earth dolly with thimbles,including cutting chases, drawing into & including PVC Concealed conduit ISI marked with all accessories on walls and making good of disturbed surfaces including all conduit fittings, clamps, gutties etc all as specified and directed. Note: (i) Two runs ( main ) of 6.00 sqmm cable together with one run ( earth ) of 4.00 sqmm cable with conduit shall be considered as 1 running meter for payment purpose.
Sub main wiring using approved colour coding as per IS with four runs of 10 sqmm PVC insulated, unsheathed cable FRLSH, flame retardant low smoke and low halogen 1100 volts grade , ISI marked with multistranded copper conductor with two run of 6 sqmm (green colour) PVC insulated, unsheathed cable FRLSH, flame retardant low smoke and low halogen 1100 volts grade , ISI marked with multistranded copper conductor as earth wire connected to common earth dolly with thimbles,cutting chases, drawing into & including PVC Concealed conduit ISI marked with all accessories on walls and making good of disturbed surfaces including all conduit fittings, clamps, gutties etc all as specified and directed. Note: (i) Four runs ( main ) of 10.00 sqmm cable together with two runs ( earth ) of 6.00 sqmm cable with conduit shall be considered as 1 running meter for payment purpose
Vertical Distribution Board iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/S 4 way, complete with appropriate size copper bus bar and neutral link complete with one MCCB 3 pole 415 Volts 100 Amps rating with rupturing cap 16 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge.
Distribution Board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, 8 way SPN, 415 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc flushed on the existing wall , to match with existing surface and making all necessary connections complete all as specified and directed.
SPN AFDD 40A-63A offering protections for overload, short circuit, Residual current characterisitics TYPE A, Over Voltage protection above 270 AC plus minus 5% & series parallel arc fault. AFDD must be dual test button for AFDD and Earth leakage functions along with single diagnostic LED with blinking patterns for continuous ON, Series Arc, Parallel arc and overvoltage protection complete all as specified and directed.
Portable current residual device (PRCD) 16 A 30mA Euro II all as specified and as directed by Engr in charge.
MCB TPN 63 Amp,415 volts,50Hz, 10KA, 'C' series ISI marked as incoming and outgoing controlling circuit all as specified and directed.
MCB SPN 40-63 Amp,240 volts,50Hz, 10KA, 'C' series ISI marked as incoming and outgoing controlling circuit all as specified and directed.
MCB SP 6- 32 Amps, 220 volts , 50 Hzs, 10 KA , "C" series, ISI marked all as specified and directed.
Exhaust fan 300 mm sweep metal body, heavy duty, Single phase AC 230/240V, with energy efficient motor, pre lubricated double ball bearing, speed 900 rpm complete with louvers for wall mounting including grouting,making hole in the wall (Square/Round) as feasible grouting and holding down bolts, nuts, washers and provision of flexible copper conductor cable 3 core from ceiling rose to exhaust fan incl cutting of hole of required size for fixing of the exhaust fan complete all as specified and directed
Dismantling of ceiling fans,scrapping of old paint,Painting of ceiling fans complete, in situ with two coats of synthetic enamel paint over a coat of anti- corrosive zinc red oxide by spraying including filling cavities with filler, one coat after cleaning all dust etc,replacement of rubber bush,nuts,bolts,washers,split pin,down rod,copper flexible cable all as specified and directed.
Earthing complete with and including galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected with and including galvanised iron or steel earth wire, 4mm dia (No. 8 SWG) by means bolts, nuts, check nuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25(Design mix) reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SSR Part-I (2009) complete all as shown on drawings and as specified and directed by Engineer-in-Charge. Note : The unit rate includes for protecton pipe 15mm and GI earth strip 4mm from top of earth plate upto 7.50 metre above ground level.
Note: For the purpose of arriving at net contract sum, the amount of credit schedule i.e Sch 'A' section II (i.e Rs 114043.00 shall be deducted from the total amount arrived.
Total of Schedule 'A' Rs.
N.N.CONSTRUCTION (BID ID -3321185)
JK ENGINEERS (BID ID -3314483)
GURU NANAK CONSTRUCTION CO. (BID ID -3313140)
M/s Super Trading Corporation (BID ID -3321186)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
BOQ.xls
BOQ • 7.87 MB
Tenderdocument.pdf
Tender Documents • 2.71 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .