Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance NEAR PARDEEP MEDICAL HALL DEEP NAGAR JALANDHAR CANTT JALANDHAR PUNJAB 144005 | JALANDHAR | PUNJAB | 144005 | Admitted-Finance |
| 4 | Admitted-Finance 0000 UNNAMED ROAD GAJIYA KANTIT VINDHYACHAL MIRZAPUR UTTAR PRADESH 231307 | MIRZAPUR | UTTAR PRADESH | 231307 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹28,000
Closing Date
31 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Kapurthala
GE Kapurthala
Repair/Replacement/ Maintenance of street/ Security/ Perimeter lights at Mil Stn Kapurthala under GE, Kapurthala.
2021_MES_464761_1
GE KPT-41/2021-22
Open Tender
Civil Works
Item Rate
300 days
Kapurthala
As per Tender Documents
8 documents required · 8 mandatory
₹500
Yes
GE Kapurthala
₹28,000
Yes
2 Sept 2021
3 Aug 2021
2 Sept 2021
3 Aug 2021
31 Aug 2021
13 Aug 2021
60 days
Amount
Attending of day to day street/security/Gate light/Post top lantern/High mast light fixed at up to 16 mtr height (HPSV,MH,Flourescent tube light, T-5, LED , Flood light fittings etc. of any make) complaints received through telephone or in person and reactification of defects installed on street light poles 9/11 mtr long, building walls, roof by bringing down the fittings on grond or in position including replacement of lamp, ignitor, flexible wire, reflector etc including cleaning of glass/acrylic cover for clear reflection of light, replacement of old unserviceable street light fittings with new fittings etc as required to make the light fitting functional (Vehicle, ladder, tools and takes as required at site for repair/for making light fittings functional shall be provided by the contractor at his own cost and arrangement.Note : (i) Light fitting, ballast, starter, ignitor, diffuser, cable, flexible wire and LED drive if required to be replaced in repair shall be measured and paid separetely under relevant item of this BOQ for supply and fixing in replacement. however flourscent tube rod 36/40 watt where required to be replaced shall be issued under schedule 'B' but fixing of same shall be measured separetely. (ii) contractor shall be provide/deputed two electrician and two helper to attend and reactified within 24 hours of receipt of complaints. (iii) contractor manpower should be daily recieve a complaints at complaint cell at 9.00 AM by JE E/M and report after completion of complaints and handover a complaint slip as record of complaints with user signature.(iv) Flourscent tube rod 36/40 watt shall be issued under Sch 'B' free for fixing by the department. (v) Old retrived material shall be deposited in AGE E/M yard and will be given to contractor after completion of contract. (vi) Contractor will depposit new material to Engineer in charge for acceptance and then material will be issued by JE E/M daily based on assesment of complaints. Quantity of material by contractor shall be decided by Engineer in charge based on requirement.
Taking down old unserviceable any type fitting and Supply and fixing Energy saving 45 watts LED street light fitting with PDC Aluminium body and toughened glass visor fitted in frame, separately driver compartment provided, secondary optical lens for superior light distribution efficiency >95Lm/W, CCT 5700K, IP66, input voltage from 120-270 V power factor above 0.95 complete fitting including all accessories all as specified and directed by Engineer-in-Charge. Note : Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion.
Taking down old unserviceable any type fitting and Supply and fixing Energy saving 60 watts LED street light fitting with PDC Aluminium body and toughened glass visor fitted in frame, separately driver compartment provided, secondary optical lens for superior light distribution efficiency >95Lm/W, CCT 5700K, IP66, input voltage from 120-270 V power factor above 0.95 complete fitting including all accessories all as specified and directed by Engineer-in-Charge. Note : Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion.
Taking down old unserviceable any type fitting and Supply and fixing Energy saving 72 watts LED street light with PDC Aluminium body and toughened glass visor fitted in frame, secondary optical lens for superior light distribution, efficiency >90Lm/W, CCT 5700 K, IP 66 input voltage from 120-270 V power factor above 0.95 complete fitting including all accessories all as specified and directed by Engineer-in-Charge. Note : Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion.
Taking down old unserviceable any type fitting and Supply and fixing Energy saving LED flood light 30 watts suitable for high mast light with PDC Aluminium body and toughened glass visor fitted in frame, secondary optical lens for superior light distribution, efficiency >90Lm/W, CCT 5700 K, IP 66 input voltage from 120-270 V power factor above 0.95 complete fitting including all accessories all as specified and directed by Engineer-in-Charge. Note : Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion.
Taking down old unserviceable any type fitting and Supply and fixing Energy saving LED flood light 50 watts suitable for high mast light with PDC Aluminium body and toughened glass visor fitted in frame, secondary optical lens for superior light distribution, efficiency >90Lm/W, CCT 5700 K, IP 66 input voltage from 120-270 V power factor above 0.95 complete fitting including all accessories all as specified and directed by Engineer-in-Charge. Note : Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion.
Taking down old unserviceable any type fitting and Supply and fixing Energy saving LED flood light/ Highmast light 150 watts suitable for high mast light with PDC Aluminium body and toughened glass visor fitted in frame, secondary optical lens for superior light distribution, efficiency >90Lm/W, CCT 5700 K, IP 66 input voltage from 120-270 V power factor above 0.95 complete fitting including all accessories all as specified and directed by Engineer-in-Charge. Note : Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion.
Taking down old unserviceable any type of post top lantern fitting and supply and fixing decorative LED post top lantern 40 watt powder coated aluminium die cast and spun aluminium body with clear/opel diffuser suitable for Landscape lighting available in 5700K CCT IP65 input voltage from 120-270 V power factor above 0.95 complete fitting including all accessories all as specified and directed by Engineer-in-Charge. Note : Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion.
Taking down old unserviceable garden light and supply and fixing LED decorative Bollard garden lights suitable for 9-12 Watt B22 LED Lamp IP54 9w to 12 watt in inverted pyramid tropod type LED Bollard with soft 360 light, IP 65 protection, resistant to corrosion with better optic for uniform distribution complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of LED Driver sutable for LED security light Fittings 30 Watt complete all as specified and as directed.
Supply and fixing in replacement of LED Driver sutable for LED security light Fittings 45 Watt complete all as specified and as directed.
Supply and fixing in replacement of LED Driver sutable for LED security light Fittings 60 Watt complete all as specified and as directed.
S&F in replacement open construction ballast suitable for 240 volts 50 Hz 1 x 150 watt HPSV/MH Lamp. Make : Polycab /Havells/ Bajaj/CG/Philips/C&S electric
S&F in replacement open construction ballast suitable for 240 volts 50 Hz 1 x 250 watt HPSV/MH Lamp. Make : Polycab /Havells/ Bajaj/CG/Philips/C&S electric
S&F in replacement open construction ballast suitable for 240 volts 50 Hz 1 x 400 watt SON/MH Lamp. Make : Polycab /Havells/ Bajaj/CG/Philips/C&S electric
S&F in replacement electronic ballast 36/40 watt with wire suitable for 1 x 36 watt FTL sleek Make : Polycab /Havells/ Bajaj/CG/Philips/C&S electric
S&F in replacement electronic ballast 2 x 14 watt with wire suitable for 2 x 14 watt T5 FTL. Make : Polycab /Havells/ Bajaj/CG/Philips/C&S electric
S&F in replacement electronic ballast 2 x 24 watt with wire suitable for 2 x 24 watt T5 FTL Make : Polycab /Havells/ Bajaj/CG/Philips/C&S electric
S&F in replacement T-5 rod 14 watt 6500 K, suitable to operate on 240 volts. Make : Polycab /Havells/ Bajaj/CG/Philips/C&S electric
S&F in replacement T-5 rod 24 watt 6500 K, suitable to operate on 240 volts. Make : Polycab /Havells/ Bajaj/CG/Philips/C&S electric
Supply and fixing in replacement 1100 volt grade heavy duty cable 3 core 1.50 Sqmm PVC insulated copper stranded conductor passing through in 20 mm PVC pipe of cable size size 1.50 Sqmm for connection pupose of street light fitting from DB to street light fitting complete all as specified and directed by the Engineer-in-Charge. Note : Contractor should be quoted the rate including 20 mm PVC pipe and 3 core PVC insulated copper conductor cable including fixing accessories.
Supplying, laying, jointing and testing under ground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 vols grade cross sectional area 16 Sqmm 4 core laid in trences, in floor, in duct, through pipes or along the pole including taking down old one complete all as specified and directed by Engineer-in-Charge.
All As per item No 22 but cross sectional area 16 Sqmm 2 core.
All As per item No 22 but cross sectional area 10 Sqmm 4 core.
All As per item No 22 but cross sectional area 10 Sqmm 2 core.
Supplying, laying, jointing and testing PVC insulated armoured heavy duty electric cable aluminium conductor 1100 vols grade cross sectional area 25 Sqmm 2 core laid in trences, in floor, in duct, through pipes or along the pole complete all as specified and directed by Engineer-in-Charge.
All As per item No 26 but cross sectional area 25 Sqmm 3.5 core.
All As per item No 26 but cross sectional area 35 Sqmm 3.5 core.
All As per item No 26 but cross sectional area 50 Sqmm 3.5 core.
Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for foundation of poles/ stays/ laying of cables etc and getting out including trimming of sides of trenches complete all as specified and directed.
Returning, filling the soft / loose soil including spreading, leveling watering and well ramming in layers not exceeding 25 cms thick each layer complete all as specified and directed.
Removing of surplus excavated soil to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Material and labour for sand cushioning to under ground cable with a layer of sand 18 cm thick before laying of cable and 15 cm thick after laying of cable complete all as specified and directed. Note:- The thickness of 18 cm, after punning down shall be considered for recording & payment.
Material and labour for brick protection using old size sub class ‘B’ bricks, laid flat, dry adjacent to each other laid length wise perpendicular to the axis of cable complete all as specified and directed.
All as per ser item No 34 here-in-before but laying only (old serviceable bricks obtained from taking out of cable shall be reused).
M&L for preparation of old painted surface of PCC LT poles and applying two coats of synthetic enamel paint in alteranate black and white strips of 30 cm each up to 1.5 mtr height from top of PCC coping and numbering of poles complete all as specified and directed.
Labour only for cutting/pruning of tree branches 1.5 mtr all around the LT overhead lines of span n.exc 70 mtr and around the pole obstruction the overhead line & removing the branches to distance n.exc 50 mtr to be the entire satisfaction of Engineer-in-charge,
Supply & fixing GI pipe light grade 50 mm bore for cable protection fixed to pole/along wall/floor/under road etc complete all as specified and directed. Note : Clamps nuts & bolts etc shall be measured and paid for separately under appropriate items of sch 'A'
Supply & fixing GI pipe light grade 40 mm bore for cable protection fixed to pole/along wall/floor/under road etc complete all as specified and directed. Note : Clamps nuts & bolts etc shall be measured and paid for separately under appropriate items of sch 'A'
M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.
Supply and fix in replacement of Time light distribution board analog Time switch 230 volt three phase of 16 Amps rating with contactor fixed inside steel enclosure box and fixed to pole/LT Panel including clamps, nuts, bolts and washers etc complete all as specified and directed.Make Indo-Asian cat part No TL016ABO or equivalent in Legrand/Scheneider
S & F in replacment MCCB 250 Amp, 4 pole, 36 KA 415 Volt 50 Hz with adjustable thermal release and adjustable magnetic setting complete all as specified and directed. Make : Standard CAT Part No ISLCNF 0250 (Frame size SKB-3) or equivalent CAT part of make Havell's/ Siemen's/ Schnieder)
S & F in replacment MCCB 200 Amp, 4 pole, 35 KA 415 Volt 50 Hz with adjustable thermal release and adjustable magnetic setting complete all as specified and directed. Make : Standard CAT Part No ISLCNF 0250 (Frame size SKB-3) or equivalent CAT part of make Havell's/ Siemen's/ Schnieder)
GULSHAN SINGH GHAI AND SON
J.K & Company
AGGARWAL ENGINEERING CO
M/S ASHWANI SETHI
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .