Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC NA | NA | NA | 121004 | ₹1.2 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹1.2 Cr+₹4.5 L (3.86%)Rejected-AOC URBAN ESTATE URBAN ESTATE JIND 126102 | JIND | JIND | HARYANA | 126102 | ₹1.2 Cr+₹4.5 L (3.86%) | L2 | Rejected-AOC Higher side |
| 3 | L3₹1.2 Cr+₹8.1 L (6.97%)Rejected-AOC HOUSE NO 280 4 RAJ NAGAR COLONY KAITHAL ROAD JIND 126102 | JIND | HARYANA | 126102 | ₹1.2 Cr+₹8.1 L (6.97%) | L3 | Rejected-AOC Higher side |
| 4 | L4₹1.3 Cr+₹9.3 L (8.03%)Rejected-AOC | ₹1.3 Cr+₹9.3 L (8.03%) | L4 | Rejected-AOC Higher side |
| 5 | L5₹1.3 Cr+₹11.5 L (9.85%)Rejected-AOC | ₹1.3 Cr+₹11.5 L (9.85%) | L5 | Rejected-AOC Higher side |
Tender Value
₹1.2 Cr
EMD Value
₹2.4 L
Closing Date
14 Sept 2020, 4:00 pmClosed
Rohit Kumar
EE PHED Hansi Near Jind Chungi Pin-125033 Distt.Hisar
Prov. and laying of 350mm i d RCC NP-2 Pipe Inlet Channel Const. Open channel water works 1 No. S S Tank 2 Nos. RCC SS Well 3 Nos. RCC F.Beds 1 No. RCC CWT 1 No. Pump Chamber Boundary Wall CC Path O and M etc.
2020_HRY_142298_1
SE HSR No.12924 dt.20.08.2020 PHED Hansi
Open Tender
Civil Works
Works
365 days
PHED Hansi
Please refer Tender documents.
5 documents required · 5 mandatory
₹15,000
EE PHED Hansi
₹2.4 L
6 Nov 2020
2 Sept 2020
14 Sept 2020
2 Sept 2020
14 Sept 2020
2 Sept 2020
Amount
Supply and erection of Horizontal spindle spilit casing type pumping sets of minimum Four (4) star rating duties directly coupled to Ac squirrel cage induction type motor with 1440 RPM, 3 phase, 50 Hz and accessories as described in Schedule No. II complete in all respect with priming arrangement with complete base frame. "A) Raw Water Pump ( For W/W ) 700 LPM, 12 Mtrs. Head
B) Clear Water Pump ( For W/W ) 700 LPM, 40 Mtrs. Head 5.00 BHP
C) Cleaar Water Pump ( for B/S ) 400 LPM, 25 Mtrs. Head 3.00 BHP
D) Clear Water Pump ( for B/S ) 300 LPM, 30 Mtrs. Head 5.00 BHP
Supply and Fixing following CI D/F pipe and specials/Bell Mouth including cost of joining materials, laying, jointing, refilling inckuding making adequate support of masonry/ concrete for delivery and suction pipe from bell mouth in the collecting tank upto the rising main laid by the Department as per plan shown from the foundation wall of pump chamber for all the raw water and clear water puping sets at water works in position, as per specification given in schedule No. II. C) CI D/F pipes I. 100 mm i/d
II 150mm i/d
D) Bell Mouth a) 150mm i/d
a) Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 500X1200mm and 400mm deep having following accessories:- 1. Incomer switch 200 Amp. 2. Aluminum bus bar chamber of 300 Amp. Capacity. 3. Volt meter 100X100mm range 0 to 500 V (AE/KAPPA/L & T ) 4. Indicating lamp-one set.
b) Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200X900mm and 400mm deep having following items:-A) For Raw water pump sets for 700 LPM x 12 M head (a) Main switch 63 Amp. 2 Nos.. (L & T Siemens, ABB).(b) Volt meter 100X100 mm range 0 to 500 volt 1 No. (AE/KAPPA/L&T)(c) Amp. meter 100X100 mm range 0 to100 Amp. 2 Nos. (AE/KAPPA/ L&T)(d) CT 100/3 Nos. (AE/KAPPA/ L&T)(e) VSS 1 & ASS 1 No. each of approved make (f) SPP 2 Nos. of approved make(g) Motor starter, star delta 1 Nos. for 700 LPM x 12 M Head Motor (L&T Simens, AAB)(h) Capacity KVAR as per site requirement - 2 Nos.(i) Indicating Lamp-One Set( j) Change over switch 63 Amp. = 1 No.
c) Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200X900mm and 400mm deep having following items:- A) For Clear water pump sets for 700 LPM x 40 M head (a) Main switch 63 Amp. 2 Nos.. (L & T Siemens, ABB) (b) Volt meter 100X100 mm range 0 to 500 volt 1 No. (AE/KAPPA/L&T) (c) Amp. meter 100X100 mm range 0 to100 Amp. 2 Nos.(AE/KAPPA/ L&T) (d) CT 100/3 Nos. (AE/KAPPA/ L&T) (e) VSS 1 & ASS 1 No. each of approved make (f) SPP 2 Nos. of approved make (g) Motor starter, star delta 1 Nos. for 700 LPM x 40 M Head Motor (L&T Simens, AAB) (h) Capacity KVAR as per site requirement - 2 Nos. (i) Indicating Lamp-One Set ( j) Change over switch 63 Amp. = 1 No.
d) Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200X900mm and 400mm deep having following items:- A) For Clear water pump sets for 400 LPM x 25 M head = 2 Nos. (a) Main switch 63 Amp. 2 Nos.. (L & T Siemens, ABB) (b) Volt meter 100X100 mm range 0 to 500 volt 1 No. (AE/KAPPA/L&T) (c) Amp. meter 100X100 mm range 0 to100 Amp. 2 Nos. (AE/KAPPA/ L&T) (d) CT 100/3 Nos. (AE/KAPPA/ L&T) (e) VSS 1 & ASS 2 Nos. each of approved make (f) SPP 1 No. of approved make (g) Motor starter, star delta 1 Nos. for 400 LPM x 25 M Head Motor (L&T Simens, AAB) (h) Capacitor of suitable capacity = 2 Nos (i) Indicating Lamp-One Set (j) MCCB Suitable capacity for each set (k) Wiring of suitable size inside the panal board (l) Suitable capacity change over switch for raw water & clear water set
e) Supply, erection, testing and commissioning of wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200X900mm and 400mm deep having following items:-B) For Clear water pump sets for 400 LPM x 30 M head = 2 Nos. (a) Main switch 63 Amp. 2 Nos.. (L & T Siemens, ABB).(b) Volt meter 100X100 mm range 0 to 500 volt 1 No. (AE/KAPPA/L&T)(c) Amp. meter 100X100 mm range 0 to100 Amp. 2 Nos. (AE/KAPPA/ L&T) (d) CT 100/3 Nos. (AE/KAPPA/ L&T)(e) VSS 1 & ASS 2 Nos. each of approved make (f) SPP 1 No. of approved make(g) Motor starter, star delta 1 Nos. for 400 LPM x 30 M Head Motor (L&T Simens, AAB)(h) Capacitor of suitable capacity = 2 Nos. (i) Indicating Lamp-One Set(j) MCCB Suitable capacity for each set (k) Wiring of suitable size inside the panal board (l) Suitable capacity change over switch for raw water & clear water set
Supply, erection, testing of standard make wiring of 4 nos. motors with underground system in PVC and flexible pipes copper wire size 6 Sq mm complete in all respects with accessories like thimble etc. complete in respects.
Supply, erection, testing of ISI marked copper wire for 3 Nos. panel boards from main switch to panel and wiring of panel with size 10 Sq. mm copper wire ISI marked complete in all respect with accessories like thimble etc. complete in respects.
Supply, erection, testing of light fittings including wire in the Pump Chamber with material up to 10 points including switch, button, plug, PVC conduct pipe and Copper wire etc. as per approved specifications complete in respects.
Providing and fixing ceiling fan 1400 mm (56") with speed adjuster of reputed make (make Crompton, Usha, Bajaj, Orient) complete in respect..
Supply erection testing and commissioning of exhaust fans each having a capacity of 45 cubic meters per minutes complete in all respect
Providing, laying, jointing and fixing of cast iron "V" notch with dully makred with beam including embedding in 1:2 cement and grouting, levelling up to finishing complete in respects.
Supply, erection, testing of reputed make LED light 100 watts with fitting and accessories complete in respects.
Supply erection of "Wall Mounting type, solenoid driven, motor-less, electro-magnetic disphragm Dozing Metering pump working on single -phase 220/240 V. / 50 Hz, electric supply with standerd electronic controls, suitable for minimum dozing capacity 0-5 LPH, at 8 bar back pressur"e complete with necessary accessories. Make Fontus or any other standard make along with supply & erection of supply & erection of 1 No. voltage stablizer with each dozing pump alongwith 1 No. 300 ltrs. capacity ISI marked HDPE storage tank, with each dozing pump of "Sintex" other reputed & approved make.
Providing & fixing floating arm 8"i/d complete in all respect
Operation and maintenance for the complete scope of work mentioned in the DNIT (Disinfection material supplied by the PHED) as per Schedule IV for a period of 5 years after 12 months during defect liability period 3 months trial run (will be charged to the A/Mtc. estimate) Operation and maintenance during defect liability period operation only
(i) Operation and maintenance during the 1st year after defect liability period
(ii) Operation and maintenance during the 2nd year
(iii) Operation and maintenance during the 3rd year
(iv) Operation and maintenance during the 4th year
(v) Operation and maintenance during the5th year
Bidder Name
Amount
Parbhu Dayal Contractor
Messers Balaji Construction
Karambir Contractor
HARIKESH DHANDA CONTRACTOR
SURENDER CONT
SANJAY KHARB CONTRCATOR
SANJAY KHARB CONTRCATOR
SURENDER CONT
Karambir Contractor
Messers Balaji Construction
Parbhu Dayal Contractor
Parbhu Dayal Contractor
Karambir Contractor
SANJAY KHARB CONTRCATOR
Messers Balaji Construction
HARIKESH DHANDA CONTRACTOR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .