| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.7 LAccepted-AOC | L1 | Accepted-AOC BEING L1 AMONG BONAFIDE BIDS | |
| 2 | L2₹34.8 L+₹86,929 (2.56%)Rejected-Finance FLAT NO 93 POCKET 03 SECTOR 11 DWARKA NEW DELHI 110 075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L2 | Rejected-Finance REJECTED BEING L2 AMONG BONAFIDE TENDERS | |
| 3 | L3₹34.8 L+₹86,956.70 (2.56%)Rejected-Finance | L3 | Rejected-Finance REJECTED BEING L3 AMONG BONAFIDE TENDERS | |
| 4 | L4₹34.9 L+₹1.0 L (3.00%)Rejected-Finance | L4 | Rejected-Finance REJECTED BEING L4 AMONG BONAFIDE TENDERS | |
| 5 | L5₹35.1 L+₹1.2 L (3.65%)Rejected-Finance | L5 | Rejected-Finance REJECTED BEING L5 AMONG BONAFIDE TENDERS |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
26 Oct 2020, 6:00 pmClosed
GARRISON ENGINEER AF SUBROTO PARK
GARRISON ENGINEER AF SUBROTO PARK DELHI CANTT - 110010
REPAIRS TO ROOF TREATMENT STRUCTURAL MEMBERS LEAKAGE SEEPAGE AND CERTAIN MISC BR WORKS AT CAMERO COMPLEX AT SUBROTO PARK
2020_MES_381236_1
GE/SP/TOKEN-48/2020-2021
Open Tender
Civil Works
Item Rate
270 days
GARRISON ENGINEER AF SUBROTO PARK DELHI CANTT
AS PR TENDER
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER AF SUBROTO PARK
₹96,000
Yes
27 Dec 2020
26 Sept 2020
27 Oct 2020
26 Sept 2020
26 Oct 2020
6 Oct 2020
28 Sept 2020 - 5 Oct 2020
Amount
Taking down cement or cement lime plaster of any description on brick/stone or concrete surfaces etc including raking out joints,hacking for key and scrubbing down with water complete all as specified and directed by Engineer-in-Charge.
Taking down or up steel water tubing and connections of 15mm bore complete all as specified and directed by Engineer-in-Charge.
Taking down or up steel water tubing of connections 20mm bore complete all as specified and directed by Engineer-in-Charge.
Dismantling water tanks exc 250 but not exc 500 Litres, and removing to store complete all as specified and as directed by the Engineer-in-Charge
Dismantling water tanks exc 500 but not exc 1000 Litres, and removing to store complete all as specified and as directed by the Engineer-in-Charge.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed by Engr-In-Charge.
Demolition of cement concrete (unreinforced ) of any description and in any position not other wise specifically provided complete all as specified and directed by Engr-In-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specifeid and as directed by engr-in-charge.
Dismantling of plain or corrugated steel sheeting any gauge, thickness including Nainital or similar pattern roof covering complete all as specified and as directed by Engr-In-Charge.
Dismentling Structural steel work incl doors, gates complete all as specified and directed by Engr-In-Charge.
M&L, Rendering 15mm thick on fair faces of brick work in CM 1:4 mixed with water proofing compound As per manufacturer instruction finished even and smooth without using extra cement complete all as specifeid and directed by engr-in-charge. Note :- Water proofing compound shall be measure and paid separatelly.
Supply only water proofing compound ISI marked complete all as specified and as directed by Engineer-in-charge
M&L for rendering CM (1:6) 15 mm thick on other than fair faces of brick work or concrete surfaces etc including finished even and smooth without using extra cement complete all as specified and directed by Engr In Charge
M&L for rendering 5 mm thick cement plaster in CM 1 : 3 on concrete surfaces in ceiling including finishing surfaces even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. upto 4 storied building
Cutting & removing tree roots from any height of walls/roof incl removal of trees, roots & grass vegetables upto 50mtr away from bldg & making good to the damaged portion of walls in CM 1:4 or cement concrete1:2:4 type B-1 surface area exc 400 Sqcm & n exc 900Sqcm complete all as specified and directed by Engineer-in-charge.
M&L for preparing surfaces of new plaster on walls and applying two coats of cement base paint complete all as specified Over a coat of alkali resitant primer and as directed by Engineer-in-Charge.
M&L for preparation of new surface and applying two coat of distemper on wall complete all as specified and directed by Engineer-in-Charge.
M&L preparation of newly plastered or unplastered surface and applying three coats of white wash on ceiling / soffits over a coat of primer (alkalic resistance priming coat) complete all as specified and directed by Engr-In-Charge.
M&L preparation of new plastered surfaces and applying two coats of exterior acrylic emulsion paint premium quality over a coat of primer on walls/ceiling complete all as specified and directed by Engr-In-charge.
M&L complete removal existing treatment incl washing, rubbing down and stopping and applying one coats of exterior acrylic emulsion paint premium quality complete on walls/ ceiling all as specified and directed by Engr-In-Charge.
M&L complete removal of of old treated wall surfaces of any description and applying one coat of cement base paint, complete all as specifeid and directed by Engineer-in-Charge.
M&L for preparation of old surface and applying one coat of oil bound distemper white or tinted on wall complete all as directed and specified by Engineer-in-Charge.
M&L for preparation of old painted steel surface and applying one coat of synthetic enamel paint over surfaces of any description over 10cm girth or width, not otherwise described complete all as directed and specified by Engineer-in-Charge.
S&F steel water tubing, galvanised, medium grade, ISI marked with and including all fittings and fixed on walls and ceilings or in floor bore of pipe 15mm complete all as specified and directed by Engineer-in-Charge.
S&F steel water tubing, galvanised, medium grade, ISI marked with and including all fittings and fixed on walls and ceilings or in floor bore of pipe 20mm complete all as specified and directed by Engineer-in-Charge.
Cleaning and fixing only 15 mm bore steel water tubing of any grade to wall and ceiling or laying in floor complete all as specified and directed by Engineer-in-Charge.
Cleaning and fixing only 20mm bore steel water tubing of any grade to wall and ceiling or laying in floor complete all as specified and directed by Engineer-in-Charge.
Disconnecting existing tanks exc 500 but not exc 1000 Litres, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc.complete all as specified and as directed by Engr-In-Charge.
S/F rotational moulded polyethylene water tank 500 ltr capacity (cylindrical vertical with closed top) hoisted and fixed complete all as specified and as directed by Engr-In-Charge.
S/F rotational moulded polyethylene water tank 1000 ltr capacity (cylindrical vertical with closed top) hoisted and fixed complete all as specified and as directed by Engr-In-Charge.
S&F in repairs 20 mm bore ball valves high pressure of PTMT with epoxy coated aluminum rod & high-density plastic ball, screwed for iron pipe and fixed (minimum weight 210 gms) complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) pipes 110 mm single socketed, in any length with solvent cement joints fixed to walls/laid in floors incl stack clamps of stainless steel with bolts & nuts etc.complete all as specified and as directed by Engr-In-Charge.
S&F PVC (SWR) pipes 75 mm single socketed, in any length with solvent cement joints fixed to walls/laid in floors incl stack clamps of stainless steel with bolts & nuts etc.complete all as specified and as directed by Engr-In-Charge.
S&F PVC SWR floor trap with grating including jointing with solvent cement 75 mm dia.complete all as specified and as directed by Engr-In-Charge.
S&F PVC SWR bends 110 mm dia complete all as specified and as directed by Engr-In-Charge.
S&F PVC SWR bends 75 mm.complete all as specified and as directed by Engr-In-Charge.
S&F 110 mm PVC SWR Junction single (Single T) provided with access door.complete all as specified and as directed by Engr-In-Charge.
S&F PVC SWR vent cowl of size 110 mm.complete all as specified and as directed by Engr-In-Charge.
S&F PVC SWR vent cowl of size 75 mm. complete all as specified and as directed by Engr-In-Charge.
Dismantling to brick tiles or terracing tiles single layers laid bedded and pointed any mortar on roof including removing the debris including mortar out side defence land complete all as specified and directed by Engineer-in-charge
M&L for Cement Concrete 1:2:4 Type B-0 (using 12.5 mm graded stone aggregate) as in roof kerb or mud stops rounded of chamfered on edge complete all as specified and directed by Engineer-in-Charge.
M&L PCC 1:2:4, type B-1 using 12.5 mm graded stone aggregate laid as in padding complete all as specified and directed by Engineer-in-Charge.
Taking out of APP modified water proofing membrane complete on roof surface and surface properly cleaned by wire brush complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of plastered/concrete surfaces of roof and applying the under mentioned course of roof treatement complete all as specified and directed by Engineer-in-Charge.:- (a) Surface shall be throughly wire brushed, cleaned, washed, dried up properly and apply evenly a bituminuous primer coat conforming to IS @0.4 ltr /Sqm over concrete / plastered roof surface. (b) Applying evenly a tack coat of bitumen 85/25 grade @1.20 kg/ sqm. (c) Laying of 3mm thick APP membrane sheet (min weight 3 Kg/Sqm) consisting of a core of 160 gms/Sqm polyster non woven fabric mat protected on both sides with a high quality polymeric asphaltic mix again protected with thermo fusible HMHDPE FILM on dried primed surface by torch application method. APP membrane will normally be laid in length at right angle to the direction of slope. The over lap shall be minimum 100mm on longitudinal direction and 150mm on the transverse direction including cuttings, grooves etc. (d) Membrane bonded completely to the substrate & the over laps are then scaled/fused by flame. Note:- This treatement shall be done by the approved authorized applicators and guarantte of treatement shall be for 10 years.
M&L for guiniting work to RCC work in coloumn, chajjas, balconies, slabs, landings etc by removing loose, concrete, incl removing rust with short blasting and cleaning of surface with wire brush and applying epoxy treatment to rusted reinforcement and including S&F welded wire mess fabric or wire not less than 95x95x3mm adhesive plaster grade for concrete admixture and providing guniting pressure 2.00/2.50 Kg/Sq cm with admixture 1 part of cement and 3.50 part of sand and thickness 50mm average and making the surface even and smooth including necessary formwork and 10mm thick plaster over repaired surface complete all as specified and as directed by Engr-In-Charge.
S&F mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for coloumns, hooking ends and binding with and incl mild steel wire (anneealed) not less than 0.9mm dia complete all as specified and as directed by Engr-In-Charge.
_Ditto_ as above but 6 to 8mm dia, as in stirrups, binders.
M&L for 75mm thick cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base for floors finishes complete all as specified and directed by Engr-In-Charge.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engr-In-Charge.
M& L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006, 80 mm thick, M-40 grade fixing with grey cement and no pigment complete all as specified and directed by Engr-In-Charge.
M&L for Chequered cement concrete coloured tiles (300 X300) 20-25mm thick confirming to IS -1237 (rubber moulded) in floor setc, set, jointed & pointed with cement slurry 15mm thick bedding layer of cement sand mortar (1:6) complete all as specified by Engr-in-Charge.
S&F Colour coated galvalume aluminum zinc coating GI based corrugated/ style pattern steel sheet 0.50mm thick fixed to steel frame using L or J bots with washer in roofs including crumping of corrugated galvalume sheet and making good joint frame, complete all as specified and directed by Engr-in-charge.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as directed by Engr-In-Charge.
Excavating in post holes (or similar holes) each not exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance not exc 50m complete all as specified and as directed by Engr-In-Charge.
M&L for PCC 1:3:6 Type C2 using 40mm stone aggregate in foundations, filling and mass concrete all as specified and directed by Engineer-in-charge
S&F steel/work in tubular truses, purlins, rafters, struts, vertical members and similar work including special shape washers complete using ERW or induction butt welded tubes conforming to IS-1161-1979, grade St-240 complete all as specified and as directed by Engr-In-Charge.
M&L for preparation of untreated new steel surfaces exc. 10 cm width or girth of any description and applying two coat of synthetic enamel paint over one coat of red oxide zinc primer all as specified and directed by Engineer-in-charge
J D ENTERPRISES
M/S MG GROUP
Rishi Constructions
M/S PRADEEP ENTERPRISES
Hindustan Co.Co
Ashish Sehgal and Co.
deepankar trading co.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .