Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.1 LAccepted-Finance 12 1 FERRIGHAT ROAD P O BHATPARA DIST NORTH 24 PGS WEST BENGAL PIN 743123 | BHATPARA | NORTH 24 PARGANAS | WEST BENGAL | 743123 | L1 | Accepted-Finance This bidder is L1 | |
| 2 | L2₹16.8 L+₹73,320 (4.56%)Rejected-Finance 19B PANKAJINI CHATTERJEE ROAD CHARU MARKET KOLKATA WEST BENGAL 700033 UDYAM WB 10 0047115 | KOLKATA | WEST BENGAL | 700033 | L2 | Rejected-Finance This bidder is not L1 | |
| 3 | L3₹17.0 L+₹90,680 (5.64%)Rejected-Finance | L3 | Rejected-Finance This bidder is not L1 |
Tender Value
Refer Docs
EMD Value
₹34,000
Closing Date
4 Jan 2025, 5:00 pmClosed
EE
OFFICE OF THE EXECUTIVE ENGINEER JHARGRAM ELECTRICAL DIVISION, P.W.Dte. Panch Matha More, PWD Building, Opposite Rabindra Park, Dist. Jhargram, Pin- 721507
Supply, Installation, Testing and Commisssioning of Fire Detection and Alarm system for academic building and hostel building of GNM Training School, Jhargram Govt. MCH
2024_WBPWD_768548_2
WBPWD/EE/JED/eNIQ29/2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
Jhargram
Please refer Tender documents.
3 documents required · 3 mandatory
₹34,000
24 Jan 2025
11 Dec 2024
6 Jan 2025
11 Dec 2024
4 Jan 2025
11 Dec 2024
Amount
Supply, Installation, Testing and Commissioning of VDS/UL approved Addressable Multi Sensor - Smoke cum Heat detector with ROR features to raise an alarm when the temperature reaches 11.1°per Minute with inbuilt fault isolator with base with Binary coded address setting. Dual LED’s for 360° visibility. Polarity free, Sleek low-profile housing design. Regular 100mm base. IP Rating : IP - 42. as required. (Note: Detector without inbuilt fault isolator is also acceptable provided the vendor provides one independent fault isolator module for every group of addressable devices, no. of addressable devices in a group will be as per latest recommended India/international standards) (Approved Make: Honeywell-Esser/ Honeywell-Notifire/ Siemens-Cerberus Pro/ Ravel/ Secutron/ Bosch/ Edwards/ GST/ Jhonson Control/ Securiton)
Supply, Installation, Testing and Commissioning of VDS/UL approved Addressable Heat detector with Fixed temperature of 59°C and ROR feature to raise an alarm when the temperatures raises 11.1°per Minute with inbuilt fault isolator with Binary coded address setting. Dual LED’s for 360° visibility. Non-Polarized, Sleek low-profile housing design. Regular 100mm base. IP Rating: IP - 42 as required. (Note: Detector without inbuilt fault isolator is also acceptable provided the vendor provides one independent fault isolator module for every group of addressable devices, no. of addressable devices in a group will be as per latest recommended India/international standards) (Approved Make: Honeywell-Esser/ Honeywell-Notifire/ Siemens-Cerberus Pro/ Ravel/ Secutron/ Bosch/ Edwards/ GST/ Jhonson Control/ Securiton)
Supply ,Installation, Testing and Commissioning of VDS/UL approved addressable Manual Pull Station -Single Action with back box and Break Glass Rod, shall be resettable by Align key to avoid unauthenticated restorations with extra acceesories as required. (Approved Make: Honeywell-Esser/ Honeywell-Notifire/ Siemens-Cerberus Pro/ Ravel/ Secutron/ Bosch/ Edwards/ GST/ Jhonson Control/ Securiton)
Supply, Installation, Testing and Commissioning VDS/UL approved of addressable type loop sounder wall mounted type rated at 100 ± 5 DBA @ 1m for Audible annunciation, Fire Sires Sound, Indoor type IP40, ABS plastic (Note: Cnventional type sounder is also acceptable provided the vender providas addressable Control Module) with extra acceesories as required. (Approved Make: Honeywell-Esser/ Honeywell-Notifire/ Siemens-Cerberus Pro/ Ravel/ Secutron/ Bosch/ Edwards/ GST/ Jhonson Control/ Securiton)
Supply, Installation, Testing and Commissioning of Addressable Control Module for activating the Notification application devices. Shall have supervisory facility to supervise the auxiliary power Supply as well as the Notification Appliance Circuits.. Shall have Binary Coding Setting dip switches, Shall have an LED indication for normal working and active Modes with extra acceesories as required. (Approved Make: Honeywell-Esser/ Honeywell-Notifire/ Siemens-Cerberus Pro/ Ravel/ Secutron/ Bosch/ Edwards/ GST/ Jhonson Control/ Securiton)
Supply ,Installation, Testing and Commissioning of Addressable Relay Module with Non Supervised Dual potential free contacts. Shall have Binary Coded Dip Switch address settings, Shall have an LED indication for normal and active modes with extra acceesories as required. (Approved Make: Honeywell-Esser/ Honeywell-Notifire/ Siemens-Cerberus Pro/ Ravel/ Secutron/ Bosch/ Edwards/ GST/ Jhonson Control/ Securiton)
Supply, installation, Testing and commissioning of Response Indicator Alarm status is indicated By Red color LED, Operates on 12 VDC, Dual LED’s for 360deg visibility, Flush / Ceiling wall mount, Operating Voltage : 12 VD.C, Operating Current : 10mA, Alarm Indication : RED LED with extra acceesories as required. (Approved Make: Honeywell-Esser/ Honeywell-Notifire/ Siemens-Cerberus Pro/ Ravel/ Secutron/ Bosch/ Edwards/ GST/ Jhonson Control/ Securiton)
Supply ,Installation, Testing and Commissioning of Addressable fully networkable fire alarm control Panel VDS/UL approved suitable for the devices as stated in the previous item of this BOQ along with 20% spear capacity with each loop loading exceeding 80% of the capacity of detectors and devicestaken together, loop card wich will have 125 / 254 devices of both detectors and modules in a single line circuit on any combination, SLC should supports both Class A and Class B wiring. Shall have an LED indication for FIRE, Normal and Redundancy conditions which consists of display board which will have 160 Character Display with Touch key pad, Mother board which will have ARM CORTEX M3 32 Bit Processor, Inbuilt RS-485 Networking Circuit for peer to peer networking, Inbuilt USB 2.0 Port for upload and download the Configuration tools, Two inbuilt programmable inputs, Two inbuilt NAC's, and Three Programmable Relays. power Supply Board, having minimum 1000 event memory, which will have SMPS fully protected board, which its operates on 120 to 220V AC ± 10% with 50/60 Hz, battery backup 24V DC with built-in charger. the panel have IP-50 rating complete as required and as per specification. (Approved Make: Honeywell-Esser/ Honeywell-Notifire/ Siemens-Cerberus Pro/ Ravel/ Secutron/ Bosch/ Edwards/ GST/ Jhonson Control/ Securiton)
Supply & Laying of 2 Core 1.5 sq.mm FRLS copper Cable (For Loop). (Make. Finolex /Polycab /RR Keble /KEI)
Supply & Laying of 20 mm NB PVC rigid conduit pipe on the surface of the wall. (Make: Precisson-Medium/ Ploycab-Medium) .
BALAJI FIRE PROTECTION SYSTEMS (BID ID -5951357)
Fire Shield Engineering & Equipments (BID ID -5949089)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .