Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹3.2 LQualified Make: ceasefire
Model: CF-000061 602 DOLI CHAMBERS 06TH FLOOR BRAHMAKUMARIS MARG NEAR STRAND CINEMA COLABA MUMBAI CITY 2829 400058 INDIA | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | Make: ceasefire
Model: CF-000061 | L1 | Qualified | |
| 2 | Disqualified Make: LIGHTEX
Model: LIGHTEX MAKE WATER CARTRIDGE TYPE 9 LTR PIPELINE ROAD AHMEDNAGAR MAHARASHTRA 414003 | AHMEDNAGAR | MAHARASHTRA | 414003 | Make: LIGHTEX
Model: LIGHTEX MAKE WATER CARTRIDGE TYPE 9 LTR | - | Disqualified | |
| 3 | Disqualified Make: Firestop
Model: FEW9 20 AMARNATH INDUSTRIAL ESTATE ASARWA CHAKLA S O AHMEDABAD ASARWA AHMEDABAD GUJARAT 380016 UDYAM GJ 01 0114231 | AHMADABAD | GUJARAT | 380016 | Make: Firestop
Model: FEW9 | - | Disqualified | |
| 4 | Disqualified Make: NA
Model: SafetyOne9ltrWtrSP 16 1ST FLOOR CHUNAWALA BUILDING NEAR AL SADIQ HOSPITAL MOHAMMAD ALI ROAD MANDVI MUMBAI MAHARASHTRA 400003 | MUMBAI | MAHARASHTRA | 400003 | Make: NA
Model: SafetyOne9ltrWtrSP | - | Disqualified | |
| 5 | Disqualified Make: intime
Model: STW9 21 A GHANSHYAM INDL ESTATE VEERA DESAI ROAD ANDHERI MUMBAI MAHARASHTRA 400053 | MUMBAI SUBURBAN | MAHARASHTRA | 400053 | Make: intime
Model: STW9 | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
23 Jul 2018, 2:00 pmClosed
Portable Fire Extinguishers IS 15683 Experience with Gov. Required 5 Year (s) Portable Fire Extinguishers IS 15683 ( 51 ) Technical Specifications Specification Specification Name Values Allowed Values Generic Conformity to Standard IS:15683:2006 With Latest Amdmnt. - Type Stored Pressure Stored Pressure
Gas Cartridge Type Extinguishing Media Water Based Water Based
Foam Based
Powder Based
Carbon Dioxide Based
Clean Agent Expellant Medium N2 Based (Stored Pressure) CO2 Cartridge Based
N2 Based (Stored Pressure)
CO2 Extinguishing Medium Constructional Foam Based Extinguishing Media NA - Powder Based Extinguishing Media NA - Clean Agents Based Extinguishing Media NA - Foam Based Fire Extinguisher Capacity(Ltrs) NA 2
4
6
9
NA Powder Based Fire NA 1
2
NA 1/3 Extinguisher Capacity (Kg) Carbon Dioxide Based Fire Extinguisher Capacity (Kg) NA 2
3
4.5
NA Water Based Fire Extinguisher Capacity 9 2
NA Clean Agents Fire Extinguisher Capacity (Kg) NA 2
NA Weight of Filled Portable Fire Extinghuisher (Kg) 14.7 Rechargebale true - Color Coding Red - Fire Extinguisher Suitable for Class -A Fire true - Fire Extinguisher Suitable for Class -B Fire false - Fire Extinguisher Suitable for Class -C Fire false - Fire Extinguisher Suitable for Class -D Fire false - Fire Extinguisher Suitable for electrical Fire false - Performance Operating Temperature (° C) +5° C to + 55° C - Test pressure/Burst Pressurire Extinguisher except CO2 for water/Foam/Powder type fire extinguisher Test Pressure >=20 Bar
Burst Pressure >=55 Bar - Test pressure/Burst pressure for CO2 type Extinguisher (write NA if not applicable) NA - Discharge Range for Extinguisher (Meters) >=2 for Class-A - Effective Discharge Time for Fire Extinguisher
Min (Seconds) 65.5 2/3 Fire Rating for Class -A Fire Extinguisher 3A - Fire Rating for Class -B Fire Extinguisher NA - Certification BIS Marking Yes - CM/L No.* with Validity Period - - Availability of Test Report from Central Govt./NABL/ILAC accredited lab to prove conformity to specification YES - Test Report No - - Test Report Date - - Name of the Lab - - Address of the Lab - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Awadhesh Kumar Singh 411015
RDEE DIGHI ALANDI ROAD 51 15
358607
GEM/2018/B/50803
Portable Fire Extinguishers IS 15683
15 days
Maharashtra; Pune
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Portable Fire Extinguishers IS 15683 Experience with Gov. Required 5 Year (s) Portable Fire Extinguishers IS 15683 ( 51 ) Technical Specifications Specification Specification Name Values Allowed Values Generic Conformity to Standard IS:15683:2006 With Latest Amdmnt. - Type Stored Pressure Stored Pressure | - | - | - |
| Gas Cartridge Type Extinguishing Media Water Based Water Based | - | - | - |
| Foam Based | - | - | - |
| Powder Based | - | - | - |
| Carbon Dioxide Based | - | - | - |
| Clean Agent Expellant Medium N2 Based (Stored Pressure) CO2 Cartridge Based | - | - | - |
| N2 Based (Stored Pressure) | - | - | - |
| CO2 Extinguishing Medium Constructional Foam Based Extinguishing Media NA - Powder Based Extinguishing Media NA - Clean Agents Based Extinguishing Media NA - Foam Based Fire Extinguisher Capacity(Ltrs) NA 2 | - | - | - |
| 4 | - | - | - |
| 6 | - | - | - |
| 9 | - | - | - |
| NA Powder Based Fire NA 1 | - | - | - |
| 2 | - | - | - |
| NA 1/3 Extinguisher Capacity (Kg) Carbon Dioxide Based Fire Extinguisher Capacity (Kg) NA 2 | - | - | - |
| 3 | - | - | - |
| 4.5 | - | - | - |
| NA Water Based Fire Extinguisher Capacity 9 2 | - | - | - |
| NA Clean Agents Fire Extinguisher Capacity (Kg) NA 2 | - | - | - |
| NA Weight of Filled Portable Fire Extinghuisher (Kg) 14.7 Rechargebale true - Color Coding Red - Fire Extinguisher Suitable for Class -A Fire true - Fire Extinguisher Suitable for Class -B Fire false - Fire Extinguisher Suitable for Class -C Fire false - Fire Extinguisher Suitable for Class -D Fire false - Fire Extinguisher Suitable for electrical Fire false - Performance Operating Temperature (° C) +5° C to + 55° C - Test pressure/Burst Pressurire Extinguisher except CO2 for water/Foam/Powder type fire extinguisher Test Pressure >=20 Bar | - | - | - |
| Burst Pressure >=55 Bar - Test pressure/Burst pressure for CO2 type Extinguisher (write NA if not applicable) NA - Discharge Range for Extinguisher (Meters) >=2 for Class-A - Effective Discharge Time for Fire Extinguisher | - | - | - |
| Min (Seconds) 65.5 2/3 Fire Rating for Class -A Fire Extinguisher 3A - Fire Rating for Class -B Fire Extinguisher NA - Certification BIS Marking Yes - CM/L No.* with Validity Period - - Availability of Test Report from Central Govt./NABL/ILAC accredited lab to prove conformity to specification YES - Test Report No - - Test Report Date - - Name of the Lab - - Address of the Lab - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Awadhesh Kumar Singh 411015 | - | - | - |
| RDEE DIGHI ALANDI ROAD 51 15 | - | - | - |
Exempted
23 Jul 2018
20 Jul 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_358607.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .