Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.7 CrAccepted-AOC | ₹13.7 Cr | L1 | Accepted-AOC Being the lowest tenderer (L1) and reasonable |
| 2 | L2₹15.1 CrRejected-Finance | ₹15.1 Cr | L2 | Rejected-Finance Not being the lowest |
| 3 | L3₹15.3 CrRejected-Finance | ₹15.3 Cr | L3 | Rejected-Finance Not being the lowest |
| 4 | L4₹16.2 CrRejected-Finance NOT SPECIFIED | ₹16.2 Cr | L4 | Rejected-Finance Not being the lowest |
| 5 | Rejected-Technical | - | - | Rejected-Technical The firm is two class below eligible class |
Tender Value
₹12 Cr
EMD Value
₹9.3 L
Closing Date
27 Mar 2021, 6:00 pmClosed
Chief Engineer NAVY Mumbai
HQ Chief Engineer NAVY Mumbai 26 Assaye Building Colaba Mumbai 400005
PROVISION OF 50 METRE SWIMMING POOL AT INS HAMLA
2020_MES_403178_1
87852
Open Tender
Civil Works
720 days
GE Project Bhandup
As Per Tender documents
8 documents required · 8 mandatory
₹3,000
GE (P) Bhandup
₹9.3 L
Yes
Colaba Mumbai 05
15 Apr 2021
14 Dec 2020
30 Mar 2021
14 Dec 2020
27 Mar 2021
12 Mar 2021
23 Dec 2020
Amount
Total amount of Sch 'A' Part-I (BUILDINGS & STRUCTURES) brought forward from Serial Page No. 27(R)
Total amount of Sch 'A' Part-II (SITE CLEARANCE, EXCAVATION AND EARTH WORK) brought forward from Serial Page No. 29(R)
Total amount of Sch 'A' Part-III (INTERNAL WATER SUPPLY) brought forward from Serial Page No. 31
Total amount of Sch 'A' Part-IV (INTERNAL ELECTRIFICATION) brought forward from Serial Page No. 37(R)
Total amount of Sch 'A' Part-V (ROAD, PATH AND CULVERTS) brought forward from Serial Page No. 41
Total amount of Sch 'A' Part-VI (SEWAGE DISPOSAL) brought forward from Serial Page No. 44
Total amount of Sch 'A' Part-VII (AREA DRAINAGE) brought forward from Serial Page No. 37
Total amount of Sch 'A' Part-VIII (COMPOUND WALL AND GATE) brought forward from Serial Page No. 49(R)
Total amount of Sch 'A' Part-IX (EXTERNAL ELECTRIFICATION) brought forward from Serial Page No. 54
Total amount of Sch 'A' Part-X (DEMOLITION AND DISMANTLING) brought forward from Serial Page No. 57
TO BE QUOTED ITEMS IN PROVISIONAL SCHEDULES
Sch 'A' Part-II (SITE CLEARANCE, EXCAVATION AND EARTH WORK)-
Removing excavated material out side MD land. Note: (i) Before quoting the tender, the tenderers are advised to ascertain the distance out side MD and, at which the debris is to be disposed off. No extra claim what-so-ever shall be entertained on this account. (ii) This item shall be considered as per the requirement at site.
Sch 'A' Part-III (INTERNAL WATER SUPPLY)
S&F 15 mm dia Angular stop cock, quarter turn with wall flange. Make - Jaquar Model No CQT-23053 or equivalent in Crab Tree/ Kohler brand as approved.
S&F 20mm dia concealed stop cock, regular body with adjustable wall flange. Make - Jaquar Model No CQT-23089 or equivalent in Crab Tree/ Kohler brand as approved.
S&F overhead shower 120 mm dia round shape single flow (ABS body crome plated with gray face plate) with rubit cleaning system. Make - Jaquar Model No OHS -1789 or eqivalent in Crab Tree/ Kohler brandas approved.
S&F two way bib cock 15 mm dia. Make - Jaquar Model No CQT-23041 or equivalent in Crab Tree/ Kohler brand as appproved.
S&F Health faucet (ABS body) with 01 meter long PVC tube & wall hook. Make - Jaquar Model No ALD-CHR- 583 or equivalent in Crab Tree/ Kohler brand as approved
S&F PVC connections 600 mm long braided hose with M10X1 Nipple, 15 mm nut , O-Ring & Rubber washer. Make - Jaquar Model No ALD-803AB or equivalent in Crab Tree/ Kohler brand as approved
Sch 'A' Part-IV (INTERNAL ELECTRIFICATION)
S&F modular type 1 module RJ 11 telephone socket with shutter Make: Legrand: 5734 26 or equivalent in Anchor as approved
S&F modular type 1 module TV socket Make: Legrand: 5734 25 or equivalent in Anchor as approved.
S&F 20W surface/wall mounted LED batten tubelight, including LED tube/module, with PC diffuser and extruded aluminium anodised housing with LEDs as light source having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.98, CCT 6500K, THD < 10%, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the LED batten fitting complete all as specified and directed. [Make: Wipro/ Philips / Osram]
All as per Item No 24 above but 10 watts and 2 feet long
Supply, Installation, Testing and Commissioning of integral driver LED streetlight 36 watts with a nominal system lumen output of 3300 lumens and a minimum system efficacy of 90 lumen/watt. The luminaire shall have rated system lifetime of 50,000 burning hours at L70. The luminaire should have cool white colour temperature (CCT>5000K) and a CRI>70. The luminaire shall meet IP66 rating & IK05 cool white colour temperature (CCT>5000K) and a CRI>70. The luminaire shall meet IP66 rating & IK05 rating with THD<20% & Pf>0.9. The luminaire housing should be made of pressure die cast aluminium with a polycarbonate optical cover complete with GI Pipe 40 mm dia light grade ISI marked 1.5 mtr long bent to sgape and fixed with suitable clamps . The total power consumption should not exceed 36W (including driver). Similar to Philips Make GREENLINE "BRP409 LED CW 033 NR PC S1 PSU GR" or equivalent in Wipro / Osram
Supply & fix fans ceiling complete with down rod blades canopies and accessories, 230 V, 1200 mm sweep. BEE 5 star rated.
S&F engery efficient non-metalic fresh air fan having blade sweep 250 mm, speed not greater than 1760 RPM, air delivery not less than 860 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. [Make: Usha/ Havells /Crompton]
Supply & fix metal body exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louver make GEC/Almonard/ Havells
S&F ISI marked MCB for AC applications till 63 A, having breaking capacity Icn = 10 kA, conforming to IS/IEC 60898-1-2002, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters
6- 32 A, SP MCB C- curve ( For light and fans)
6- 32 A, SPN MCB C- curve ( DC light driver panels-2 + SPN DB I/C -2)
6- 32 A, TPN MCB C- curve ( For suction sweeper connection)
Supply and fix 3 phase metal plug and socket with MCB TP , 20 Amps 415V, incl metal plug top 3 phase 20 Amps
Supply and fix Mid bay Luminaires 70 watts complete with its fixing arrangemnt as per manufacturers instructions robust and reliable IP-66 and IK 08 protectd LED light fitting,with PDC housing and toughend glass ceiling mounted and available on wide beam make Philips model Endura ELD Midbay cat no. BY150P LED 76 S CW PSU HE SY 120FG GR LILO or equivalent in Wipro/ Osram ( For Plant Room)
Supply, Installation, Testing and Commissioning of LED integral driver flood light 104 Watts with a nominal system lumen output of 11000 lumens and a minimum system efficacy of 105 lumen/watt. The luminaire shall have rated system lifetime of 50,000 burning hours at L70. The luminaire should have cool white colour temperature and a CRI>70. The luminaire shall meet IP66 rating with THD<20% & Pf>0.9. The luminaire housing should be made of pressure die cast aluminium. The total power consumption should not exceed 104W (including driver). Similar to Philips Make UNIFLOOD "BVP122 LED 110 CW NB FG XTFC" or equivalent in Wipro/ Osram ( Spectator gallery)
Supply, Installation, Testing and Commissioning of LED Surface mounted Troffer Luminaire 40 watts capacity with a nomial system lumen output of 3200 lumens and a minimum system efficacy of 80 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a color temperature of 5000K and CRI>70. The luminaire shall meet IP20 rating with THD<10% and PF >0.9. The luminaire housing should made of powder coated metallic CRCA with high efficiency opal diffuser with a flat cover. The total power consumption should not exceed 40W (including driver). Philips Make CIRRUS SURFACE "SM366 LED32 6500 PSU OD GR" or equivalent in Wipro / Osram ( for Porch, entrance verandah and entrance hall)
Sch 'A' Part-IX (EXTERNAL ELECTRIFICATION)
Supply, installing, testing and commissioning step down Transformer, outdoor type, HT -11 KV, 3 Phase, LT- 433 Volts, 50 Hz, 3 phase 4 wire Oil cooled, and naturally air cooled, with electrolyte grade copper wound in accordance with vector group DYN 11 with neutral brought out on LV side with tapping on HV side to vary secondary voltage upto ± 7.5 % in steps of 2.5% with off load type tap changing switch, locking arrangement complete with all standard fittings all as specified and of capacity 500 KVA and confirming following technical specifications:- (Make: Siemens/ Alsthom/ ABB/ Areva/ GE/ Voltamp/ Indian transformers) a) Rating: HV-11 KV, LV-433 Volts
b) Winding connections: HV-Delta, LV-Star c) Tappings on HV: ± 2.5%, total = 7.5%, OFF Circuit links d) Insulation class - 'H' e) Applicable Standards - IS: 1180 f) Conservator and breather with silica gel container g) Termination: (i) HV & LV cable box on outside for easy connection (ii) HV & LV cable glands of standard rating h) Duty: Distribution transformer j) Explosion vent k) Full load losses: within the permisible as per latest IS-1180 l) No load losses: within the permisible as per latest IS-1180 m) Cooling: ANON
n) Protection Device: (i) Protection relay against temperature rise to trip VCB and alarm be also provided (ii) Surge protection (iii) Protection against over current and earth fault. o) Contractor shall submit the technical drawing, Constructional drawings, safety features drawing and data sheet etc. for approval of Garrison Engineer.
Supply, install, testing and commissioning of indoor 11 KV HT switch gear, extendible type, vertical isolation and horizontal draw out, vacuum circuit breaker (VCB), rupturing capacity 350 MVA, 630 Amps, with DC tripping arrangement mounted on structural steel frame outdoor type with separate indoor control panel with over current and earth fault relays of suitable rating and each fitted with following :- a) 3 Nos vacuum interrupters of rating 11 KV, 3 phase, 50 Hz, 350 MVA, 630 Amps mounted on common base segregated epoxy body for higher electrical insulation and to maintain pole discrepancy as per IEC 56 and self aligned type isolating contacts, manual and motor operating (230 volt AC), spring charged mechanism, manual closing and tripping push buttons, mechanical operation counter 8 NO+8NC breaker operating auxiliary switch, spring charged /discharged indication, circuit breaker service /test position indication all as directed - 1 No.
h) 1No. AC static, HT, Tri vector meter. Meter should be supplied with Backlit LCD/LED display of measured value (s) shall be displayed on seven segment, seven digit liquid crystal display (LCD/LED) Display unit / register. Make- L&T / Secure / C&S / AE j) Cast resin current transformer 11 KV dual ratio 100-50/5/Amp, 15 VA / 5P 10 for protection - 3 Nos. k) Cast resin potential transformer dry type having minimum 200 VA burden ratio 11 KV /110 V with HT and LT fuses -set of three-01 No l) Power pack equipment with backup for 15 minutes including maintenance free m) Set of LED indicating lamp operating at 110 V single phase as below :- (i) RED/GREEN :- VCB ON-OFF indication (ii) AMBER :- Trip indication (iii) White :- Trip circuit healthy indication with push button (iv) BLUE :- VCB mechanism spring charged indication
n) One set of heat shrinkable PVC sleeved, 400 amps copper busbar -1 Set o) 1 No. Strip heater -100 watt (continuously rated) with thermostat control for breaker / CT compartment with manual ON-OFF switch -1 set p) Structural steel frame including PCC fdn and earth work as per manufacturer specification. q) 1 No 3 way breaker control switch with positions TRIP- NEUTRAL -CLOSE r) Manual charging /operating arrangement. s) Fuses for metering and protection system. t) (i) Auto trip (ii) Motor /manual charged spring operating /closing mechanism. (iii) Fault alarm (iv) Manual tripping
u) Complete control panel wiring with suitable size copper wire. v) Test Terminal Block (TTB) to test meters and relays with sealing arrangement. Note :- (i) The HT panel comprising of VCB to be manufactured by OEM and not from their feeder supplier / vender and contractor has to arrange factory inspection for routine test as per IS at OEM factory in presence of rep nominated by accepting officer before despatch from OEM's factory. (ii) Contractor shall produce manufacturers test certificate for all routine and type test of VCB's. (iii) Civil work for foundation as per manual of manufacturer.
Supply, install, testing and commissioning of outdoor 11 KV HT switch gear, , extendible type, vertical isolation and horizontal draw out, vacuum circuit breaker (VCB), rupturing capacity 350 MVA, 630 Amps, with DC tripping arrangement mounted on structural steel frame outdoor type with separate indoor control panel with over current and earth fault relays of suitable rating and each fitted with following (3 Nos - one as incomer & two as outgoing) :- a) 3 Nos vacuum interrupters of rating 11 KV, 3 phase, 50 Hz, 350 MVA, 630 Amps mounted on common base segregated epoxy body for higher electrical insulation and to maintain pole discrepancy as per IEC 56 and self aligned type isolating contacts, manual and motor operating (230 volt AC ), spring charged mechanism, manual closing and tripping push buttons, mechanical operation counter 8 NO+8NC breaker operating auxiliary switch, spring charged /discharged indication, circuit breaker service /test position indication all as directed - 1 No.
h) 1No. AC static, HT, Tri vector meter. Meter should be supplied with Backlit LCD/LED display of measured value (s) shall be displayed on seven segment, seven digit liquid crystal display (LCD/LED) Display unit / register. Make- L&T / Secure / C&S / AE j) Cast resin current transformer 11 KV dual ratio 100-50/5/Amp, 15 VA / 5P 10 for protection - 3 Nos. k) Cast resin potential transformer dry type having minimum 200 VA burden ratio 11 KV /110 V with HT and LT fuses -set of three-01 No l) Power pack equipment with backup for 15 minutes including suitable maintenance free batteries m) Set of LED indicating lamp operating at 110 V single phase as below :- (i) RED/GREEN :- VCB ON-OFF indication (ii) AMBER :- Trip indication (iii) White :- Trip circuit healthy indication with push button (iv) BLUE :- VCB mechanism spring charged indication
n) One set of heat shrinkable PVC sleeved, 400 amps copper busbar -1 Set o) 1 No. Strip heater -100 watt (continuously rated) with thermostat control for breaker / CT compartment with manual ON-OFF switch -1 set p) Structural steel frame including PCC fdn and earth work as per manufacturer specification. q) 1 No 3 way breaker control switch with positions TRIP- NEUTRAL -CLOSE r) Manual charging /operating arrangement. s) Fuses for metering and protection system. t) (i) Auto trip (ii) Motor /manual charged spring operating /closing mechanism. (iii) Fault alarm (iv) Manual tripping
u) Complete control panel wiring with suitable size copper wire. v) Test Terminal Block (TTB) to test meters and relays with sealing arrangement. Note :- (i) The HT panel comprising of VCB to be manufactured by OEM and not from their feeder supplier / vendor and contractor has to arrange factory inspection for routine test as per IS at OEM factory in presence of rep nominated by accepting officer before despatch from OEM's factory. (ii) Contractor shall produce manufacturers test certificate for all routine and type test of VCB's. (iii) Civil work for foundation as per manual of manufacturer.
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, indoor type, APFC capacitor bank Panel Board of size as recommended by manufacturer 120 KVAR with 5 Steps (2x10+ 2x12.5 + 3x25) suitable for Auto and manual operation with MD-XL capacitor,480 V, 3 Ph and MCCB as incomer, Automatic Power Factor Correction panel , made out of 2 mm thick CRCA Sheet Dust and Vermin Proof, single door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, prewired complete,suitable for manual and automatic operations facilities, with Intelligent switching APFC relay 8 stages, with suitable capacitor duty contactors, The enclosure shall be pre-treated as per 11 tanks process and finished with powder coating of shade RAL 7032. , including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 300 mm above the Normal Ground Level and 300 mm below ground complete
with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Testing after Installation complete all as specified .The panel shall be factory fabricated comprising of following: INCOMER i) MCCB 160-400 A 35 KA,4 POLE ,thermal magnetic release, Ics=100% Icu - 1 no.(Thermal Magnetic Release) ii) Suitable rated Aluminim Bus bars -04 nos mounted on epoxy insulators. OUTGOING CAPACITOR FEEDERS : - 10 KVAr Capacitor feeder comprising of:- (2 Nos) Ultra heavy duty capacior LTXL , box type oil Filled Capacitor bank 10 kVAr, suitable for 480V -2 NOS Push Button ON/OFF -4nos Indicating lamps 4 NOS Suitable rating MCB TP of D curve for capacitor-02Nos Suitable rating Contactors capacitor duty for capacitor-02Nos
12.5 KVAr Capacitor feeder comprising of:- (2 Nos) Ultra heavy duty capacitor LTXL , BOX type oil Filled Capacitor bank 12.5 kVAr ,suitable for 480V , - 2 NOS Push Button ON/OFF - 4 nos Indicating lamps 4NOS Suitable rating MCB TP of D curve for capacitor-02Nos Suitable rating Contactors capacitor duty for capacitor-02Nos 25 KVAr Capacitor feeder comprising of:- (3 Nos) Suitable rating MCB TP of D curve for capacitor-03 Nos Ultra heavy duty capacitor LTXL , BOX type oil Filled Capacitor bank 25 kVAr, suitable for 480V Qty-3 Push Button ON/OFF - 6 nos Suitable rating Contactors capacitor duty for capacitor-03Nos ii) Voltmeter, Digital type - 01 set iii) R-Y-B phase indicating lamp- 03 Nos iv) APFC relay intelligent switching 8 stage-01 No.
Supply,install, test and commission, outdoor type ,CPRI approved ,LT panel box ,cubicle type, factory fabricated, panel board made with 2 mm thick CRCA Sheet , weather and vermin proof ,with suitable MS angle iron stand , IP-52 protection Class 11 tank process ,powder coated in siemens gray colour inside and outside, 3 phase, 4 wire system copper bus bar mounted on hygroscopic insulator housed in separate bus bar chamber covered with R-Y-B and black PVC heat shrinkable sleeve, with 50mmx50mmx6mm angle iron frame with and including PCC 1:3:6 type C2 foundation and covering front and back opening hinged door along with suitable locking arrengement including necessry bus bar tappings, copper control wiring of required size, connecting cable with necessary cable glands, lugs etc, independent chamber to accomodate the MCCBs MCBs,measuring instruments,Bus bar and cable gallary chember ,proper arrangements for ventilation complete with provn for connecting earthing at both sides of panel board and comprises as following:- (Main Panel) (Near transformer)
INCOMER i)MCCB MP based 300-800 Amps 50 KA 4 Pole Suitable for 440 V 50 Hz AC Supply (Incommer from transformer) ii) Bus Bar Aluminium with Sleeves of rating 1000 amps -04 Nos.mounted on suitable epoxy insulators and supports OUTGOING i)MCCB 4 Pole, 415 V, 160-400 Amps 36 KA - 01 No.(Outgoing to AMF) ii)MCCB 4 Pole, 415 V, 100-250 Amps 36 KA - 01 No.(Outgoing to Catering School) iii)MCCB 4 Pole, 415 V, 63-160 Amps 25 KA - 01 No.(Outgoing to Gymnasium)
Supply,install, test and commission, outdoor type ,LT panel box ,cubicle type, factory fabricated, CPRI approved (any company from list of make), panel board made with 2 mm thick CRCA Sheet , weather and vermin proof ,floor mounted , IP-52 protection Class 7 tank process ,powder coated in siemens gray colour inside and outside, 3 phase, 4 wire system copper bus bar mounted on hygroscopic insulator housed in separate bus bar chamber covered with R-Y-B and black PVC heat shrinkable sleeve, with 50mmx50mmx6mm angle iron frame with and including PCC 1:3:6 type C2 foundation and covering front and back opening hinged door along with suitable locking arrengement including necessry bus bar tappings, copper control wiring of required size, connecting cable with necessary cable glands, lugs etc, independent chamber to accomodate the MCCBs MCBs,measuring instruments,Bus bar and cable gallary chember ,proper arrangements for ventilation complete with provn for connecting earthing at both sides of panel board and comprises as following:- (swimming pool panel)
INCOMER i)MCCB 4 Pole, 415 V, 320-400 Amps 36 KA - 01 No. OUTGOING i)MCCB 4 Pole, 415 V, 63-160 Amps 36 KA - 01 No.(Filtration plant) ii)MCCB 4 Pole, 415 V, 60-160 Amps 36 KA - 02 No.(STP & SPARE) iii)MCCB 4 Pole, 415 V, 40-100 Amps 25 KA - 01 No.(Swimming pool load) iv)MCCB 4 Pole, 415 V, 16-40 Amps 25 KA - 01 No.(Perimeter lights) v)MCCB 4 Pole, 415 V, 16-40 Amps 25 KA - 01 No.(Flood Light Panel) vi) Astronomical time switch for street light-01 No(Perimeter Light Control) METERING & INDICATION i) Ammeter, Digital type, with suitable CTs - 01 set ii) Voltmeter, Digital type - 01 set iii) R-Y-B phase indicating lamp- 03 Nos
Supply & Fix HT Cable route indicator made out of cast iron 10 cm dia duly engraved with letters 'HT CABLE 11000 Volts" fixed in 20mm X 20 mm equal angle 0.5 mtr long icluding provision of PCC block of 20 cm X 20 Cm X 20 cm complete all as specified and directed.
M&L for Earthing complete with galvanised earth plate electrode 60 cm x 60cmx 6.00 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level, connected to GI strip 32 x 6 mm as earthing lead by means bolts and nuts check nuts and washers of galvanized iron and connected to main switch board including 20 mm bore medium grade GI Pipe with MS funnel with wire mesh,.watering arrangement and 40 mm bore light grade GI pipe for earth lead protection from earth plate to test point or pannel connceting point, PCC chamber, CI cover with frame etc including necessary excavation in any type of strata, returning, filling , removal of soil outside MD land ,filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part - I, connected to Earthing test point all as specified and directed and testing on completion.
S&F for road lighting luminaire LED lights 72 watt IP66 Powder coated pressure die cast aluminium compact High Power LED Street light with heat resistant toughened glass with lens. complete with GI pipe bracket made out of 40 mm dia Light grade GI pipe 1.5 mtr long all as directed and complete with Nut bolts clamps etc suitable for octagonal poles , Make BAJAJ Cat No. 169698 BARFEG 72 W LE/Philips cat No.BRP410 LED CW 066 NR PC S1 PSU GR or equivalent in Wipro/Jaquar
M&L for 7 meter long hot dipped galvanised octagonal poles with top A/F 70 mm bottom A/F 155 mm made out of 3mm thick HT sheet along with base plate of size 260X260 X16 mm including 1500 mm long single arm bracket made out of 48 mm dia GI pipe and M20 x700 m long 'J' type EN8 grade foundation bolts along with template including the following: (a) MCB SP 6A 230 V,10 kA mounted on 3 mm thick Hylam Sheet -1 No. (b) 4 Way connector bolt along with locking arrangement, weather proof and water proof control space. Note: (a) The Rate quoted deemed to include the cost of 50 mm PVC pipe from cable trench to center of the pole concrete and 'J' type EN8 grade foundation bolts. (b) The rate quoted deemed to include the cost of connecting of incoming and outgoing cable in new octagonal poles through PVC pipe including taking out loop extending up to junction box connecting complete all as specified and directed.
Supply and fix 2.5 sqmm 3 core PVC copper cable multi stranded drawn through inside octagonal pole from bottom connector to fitting including providing necessary lugs complete all as specified and directed.
S & F for Flood lighting luminaire LED lights 240 watt IP 66 Powder coated pressure die cast aluminium compact High Power LED flood light with heat resistant toughened glass with lens. complete on GI bracket all as directed and complete with Nut bolts clamps etc, Make Philips cat No. BVP 410 LED 252 CW HE AK55 FG S3 XTFC or equivalent in Wipro/ Jaquar
M&L for 12 metre long hot dipped galvanised octagonal poles made out of 3.0 mm thick HT sheet along with base plate of size 320 mm x 20 mm thick, including 7 feet long Angle iron - 03 nos, made out of GI of size 50x50x5 mm thick suitable brackets, nuts bolts GI , with M24 x800 m long 'J' type EN8 grade foundation bolt-04 nos along with Nameplate, suitable to take load of 06 LED Flood light fittings per pole all as directed and complete model No. JIL 12010 C of Jindal or equivalent in Philips/Bajaj/Crompton. Note: 1) Mast and Pole shaft shall be BSEN-10025, ASTM A 752, and IS-5986. Foundation as per IS-2062/E250A, Base plate as per IS-2062, and galvanisation as per IS-4759/2629 and ASTM A123 2) Rate Quoted shall be inclusive of foundation as per manufacturers recommendations
Sch 'A' Part-XI (FILTRATION PLANT)
Supply install test and commisioning of Factory made Vertical cylindrical type multigrade pressure white quartz sand filter capacity minimum 175 m3/ hour made from MS sheet suitable for working pressure 3.5 Kg/cm2 duly painted (inner & outer) with red oxide primer and two coats epoxy paint complete with suitable size of inlet, outlet valves, NRVs, control valves for for operation, back wash system incl valve manifold, drain out facilities complete including frontal piping of UPVC/ MS suitable sizes pipes for discharge of 175 M3 /hour / pressure rating 10 Kgf/cm2, fittings and filteration rate of less than 10 litres/ sec/ sq mtr, filter media etc as required for smooth functioing and operation all as per manufacturer designed discharge capacity.
Note: 1. Rate quoted is deemed to be included for all type & size of UPVC/ HDPE/ MS frontal piping, control valves connected to the pressure filter and PCC foundation. 2. Piping up to pressure filter inlet & beyond out let of pressure filter and drain pipe shall be measured and paid separately- Make: Ion Exchange India Ltd /Thermax / UV rich
Supply install test and commisioning of Air Blower with suitable 3 Phase motor IE-2 rated , ISI marked required for filtration unit back wash process of suitable capacity but not less than 200 Cum /Hr , or as recommended by OEM for swimming pool and Diving pool as given in schedules Make: Ion Exchange / Everest/ Astral pools/ Khosla
Supply install test and commisioning of Water circulation, Horizontal split casing end suction pump 415 V, 50 Hz, 1450 RPM suitable for pressure filter designed discharge capacity 160 m3/ hour @ 25 Mtr head having pump efficiency 65-75%, and suitable for filteration plant as per Sl No 1 (a) for ensuring turnover period 7.0 to 8.0 hour with suitable capacity prime mover. The pump shall be of cast iron body, bronze impellar, with mechanical seals, TEFC squirrel cage IE-2 induction motor, M.S. Fabricated base plate, mounting channel frame, accessories and fitting i.e. pressure gauges, Air release valve, drains, coupling, coupling guard, PCC foundation, vibration isolation arrangement complete all as specified in the particular specification. Make Kirloskar or equivalent (02 Working+02 Standby for swimming pool , and 01 working +01 stand by for diving pool)
Supply install test and commisioning of Alum/Chlorine, Dosing pump (venturi drive pump) 0 - 16 LPH with PP/PVC dozing tank capacity 200 Ltr - 01 Nos and piping for in let & out let connection complete with control valves, NRV, metering, electric cabling & copper wiring through PVC concealed conduit from Main control panel to booster pump. Make: Ion Exchange/ Thermax / UV rich/ Astral pools/ Procopi S A
Supply install test and commisioning of Acid/ alkali Dosing pump (venturi drive pump) 0 - 16 LPH with PP/PVC dozing tank capacity 200 Ltr with high speed stirrer and piping for in let & out let connection complete with control valves, NRV, electric cabling & copper wiring through PVCconduit from Main control panel to booster pump. Make: Ion Exchange / Thermax/ UV Rich/ Astral pools/ Procopi S A
Supply install test and commisioning of Pool drains (drain out sump) - 500 MM X 500 MM – MOC SS 316 Make: Ion exchange/ Thermax/ UV Rich/ Astral pools/ Procopi S A
Supply and install Stainless steel ladders of Swimming pool made out of model stainless steel AISI-304 of width 500 mm with handrails and shall be 40 mm dia of stainless steel with non-slip all as shown on drg and all as dircted by E-in-Charge Make: Ion Exchange/ Astral pools/ Procopi S A
Pool ladder 3 steps
Pool ladder 4 steps
Pool ladder 5 steps ( 2 for S/pool and 04 for diving pool)
Supply and install Over flow grating 300 mm x 300 mm wide shall be provided as shown in drawing with slope 1:200, towards shall be provided as shown in drawing with slope 1:200, towards balancing tank including Gratings and support profiles made in white UV stabilized PP of size wide. Make. Make:IonExchange/ Thermax / UV rich/ Astral pools/ Procopi S A
Supply install test and commisioning of Trolley mounted suction sweeper with self priming electric driven pump set suitable for cleaning swimming pool capacity , complete with PVC braided vacuum hose pipe of length minimum 30 Metre, 900 mm size Aluminum / bronze vacuum head, flexible copper cable from Main, PVC floats, wire rope and all connected accessories complete. Make: Ion Exchange (pump & motor:Kirloskar) / Astral pools/ Procopi S A
S&F 18 inch long Nylon brush Make : Ion Exchange/ Astral pools/ Procopi S A
M & L for Telescopic pole 4.8 Mtr long with extendible up 9 Mtr made of aluminum tubing complete Make : Ion Exchange/ Astral pools/ Procopi S A
S&F Test Kit for PH & Residual chlorine Make : Ion Exchange/ Astral pools/ Procopi S A
TCCA 90 - 100 kgs or Hypo liquid for commissioning
M&L for Leaf rack made out of aluminium frame all as per sample. Make : Ion Exchange / Astral pools/ Procopi S A
M&L for Leaf skimmer made out of aluminium frame all as per sample. Make : Ion Exchange / Astral pools/ Procopi S A
Supply install test and commisioning of Ozonator for pool (capacity 31 lakh litre ) disinfection by production of Ozone from atmospheric air with capacity 150 gm/hour comprising with Ozone generating unit, Venture for injection of Ozone in to water main - 02 nos( Main pool and diving pool) including their control valves, venture drive / booster pump, air compressor Ozone control unit complete , and all as mentioned in PS clause and as per manufacturer designed capacity. Make : Ion exchange / Thermax/ UV rich/ Nectar solutions/ OZ-Air
Supply install test and commisioning of Pool under water integral LED model 14.4 Watt, wall mounted type working on 12 V DC, IP68 complete with built-in driver, including push in connector in 4 pole, flexible conduit and all fixing arrangement in swimming pool wall including and flexible conduit accommodate pool light Make : Ion Exchange/ Thermax/ U V Rich/ Astral pools/ Procopi S A
Supply install test and commisioning of Junction box of suitable size round/square type with water proof covering made of ABS plastic material. Make: Sintex/ Hensel or equivalent as approved by GE
Supply install test and commisioning of Pool floor inlets (pool jets) 63 mm dia including tail piece of 63 mm dia 20cm long with pool floor inlets made out of plastic white colour with SS screws suitable for flow rate of 6000 ltr/hr top of floor tiles provided in swimming pool all as per insturction of manufactures and swimming pool designer complete all as specified and directed. Make- Ion Exchange/ Thermax/ U V rich
All as per item no. 68.00 above but suitable for capacity 9000 litres per hour for diving pool
Supply and install lint hair catcher of size 500x700 mm complete all as directed. Make- Ion Exchange/ Thermax / U V rich by GE
Supply installation and testing of Diving board with wooden with FRP covering & Fulcrum with supports of 5.0 metre long and 0.5 metre width, Model ION 500 Make : Ion Exchange or equivalent as approved by GE
S&F Racing lane holding hooks - SS 304 - 60 MM ID, 10 MM thick rod with bracket Make : Ion Exchange or equivalent as approved by GE
S&F Racing lane 50 metre with float – 100 mm of polyster Material. Make : Ion Exchange or equivalent as approved by GE
M&L for Starting block in SS 304 Material Size of platform - 500 MM X 500 MM with sturdy base and handle bar for back stroke start-ups, numbered 1 TO 8 and grouted firmly in position in PCC 1:3:6 as directed, wood, laminated in FRP body using Isothelic resin, non skid surface and thickness 2.5 inch to 1.5 inch tappered from one end to other size - 0.5 metre wide. Make : Ion Exchange or equivalent as approved by GE
Lifebuoy 500 MM Dia - SS Bracket for holding lifebuoy Make : Ion Exchange or equivalent as approved by GE
Supply install test and commisioning of piping and valve system as shown in drg and as required essentially for swimming and diving pool concealed/ open type with UPVC/MS pipes & fittings - 80 schedule UPVC pipes and MS pipes Heavy grade Epoxy coated for suction and delivery pipes of pumps upto common headers consisting of the following:-
i) PIPING - UPVC Pipes & fittings -150mm, 200mm, 250mm and 300 mm int dia - 80 schedule,with suitable size Butterfly / sluice valves as applicable - ISI marked
ii) Piping MS epoxy coated heavy grade, ISI marked of dia 250 and 350 mm mm for suction lines of 06 pumps separately with suitable 250 mm dia Foot valve Make: Normex with CI body and synthetic metal ball, strainer etc complete or as approved by GE
iii) MS delivery pipes from pump sets 150 mm dia MS epoxy coated heavy duty complete with suitable tailor made special and connected to commn header and 300 mm dia NRV ISI marked -06 nos and PN 1.6 rating sluice valve IS-14846 -06 Nos complete
iv) MS epoxy coated heavy duty common header 300 mm dia for delivery and suction header of suitable length including required MS specials
v) MS pipe heavy duty epoxy coated of 200 mm dia with specials complete from common header to pressure filters incl necessary butterfly valves
vi) Out let UPVC pipes 250 mm dia from pressure filters to swimming pool and diving pool incl suitable MS butterfly valves 250 mm dia of suitable pressure rating of suitable lengths complete-02 nos. ( One for swimming pool + Diving pool)
vii) Concealed UPVC pipes 150 mm dia 80 schedule for outlet nozzles complete with suitable fixing arrangements inside diving pool complete
viii) Concealed UPVC pipes 150 mm dia 80 schedule for outlet nozzles complete with suitable fixing arrangements inside swimming pool complete
ix) Concealed UPVC pipes 150/ 200/ 250/ 300 mm dia 80 schedule for Overflow from Diving pool and Swimming pool (2 Runs each) complete upto Balancing tank through lint catcher
x) Concealed UPVC pipes 2500 mm dia 80 schedule for drain complete with suitable fixing arrangements inside diving pool and swimming pool and upto common point and 300 mm dia UPVC pipe 10 Kg pressure upto balancing tank with 300 mm dia sluice valve with SS spindle PN 1.6 rating IS-14846 Make: Kirloskar with Suitable operating rod from Balancing tank top complete all as specified and directed or as approved by GE
xi) MSEP wash out pipe 250 mm dia heavy duty from Pump delivery common header till out side rain / Storm water drain including 300 mm dia sluice valve IS-14846,PN1.0 rating Long body with wheel on top for operation complete.
xii) MSEP wash out pipe 200 mm dia heavy duty-02 nos from pressure filters till out side rain / Storm water drain including 200 mm dia butterfly valve ISI marked with complete.
xiii) Hair strainers - 06 nos Make : Ion Exchange or equivalent as approved by GE capacity 160 Cum /Hr 'T' type with strainer mesh made out of SS 304 grade xiv) Set of valve manifold for each filter for operation mode in Filter/ Bypass / rinse/back wash/drain mode of 200 mm dia MS butterfly valves of Make- Kartar / Kirlokar/ Upadhaya or as approvee by GE Notes for Sr Item No 75.00 to 75.13:- (a) All UPVC pipe & fittings shall be as per UPVC schedule 80 (b) All MS pipe & fittings shall be heavy grade & epoxy painted.
Supply install test and commisioning of Electrical cablling for dosing system, starters of blowers & pumps under water lights consisting of the following
i) Copper wiring of suitable size with Suitable GI Protection pipe for Pump set (approx capacity 30 HP) from starter panel to Motor (6 runs of Copper wire for star delta starters) - 06 Jobs
ii)Copper wiring of suitable size for Air blower from starter panel to Motor with Suitable GI protection pipe
iii) FRLS Copper wiring of suitable size with PVC conduits deck level junction boxesmade out of white ABS for under water lights 12 V, DC capacity -50 Nos.incl submain for circuits of suitable sizes from main Panel Room.
iv) Copper wiring of suitable size for dosing pumps from starter panel to dosing Motor with Suitable GI protection pipe
v) Suitable DB's with MCB's and RCBO for under water pool lights
vi) Copper wiring of suitable size from main filteration plant panel to Ozonator panel
vi) Any Internal wiring related to swimming pool and diving pool which is left out but required technically at Site will be provided by the contractor without any extra cost
Fabricate, Supply install test and commissioning of CPRI approved factory fabricated indoor type LT panel board suitable for 440 Volt, 3 phase & Neutral , 50Hz supply , floor mounted weather and vermin proof fabricated from MS angle of size 50x50x5 mm as base frame,with 2 mm thick CRCA sheet (Make -Tata/ sail) ( load bearing members 2 mm thick and non load bearing members such as doors partitions etc of thick ness 1.6 mm thick ), with gland plates at bottom with suitable Brass chromium plated glands, with cadmium plated high tensile nut and bolts washers, suitable barrel copper lugs for cable terminations complete, with locking arrangements complete ,sheets bend, folded, cut with CNC machine for the accuracy of dimensions +/-0.5%, duly powder coated (after minimum 9 tank porecess of pre chemical treatement) with siemens grey colour, with suitable ventilation, including LED RYB indicators -06 nos on incoming side and ON/OFF/TRIP indications on outgoing side of Incomer, interconnections from bus bars to MCCB's with suitable
size copper bus bars, all internal ckt / protection wiring with FRHR 1100 V grade wiring with MCB protection, including terminal adapters, spreader links on incoming and out going sides of ACB's/ MCCB's complete all as specified and directed and comprising of the following (for Fileration plant Pump house) (a) Bus bar Aluminum -300 A capacity- 04 Nos a , high conductivity, suitable for 415 V, 50 Hz supply including interconnection from incoming, and out going feeders with suitable mounting insulators, heat shrinkable colour sleeves. .
(b) MCCB four pole 440 V, 200 Amp, 36 KA , Cat No. DN1-250C, range 160-200 Amps, with thermal and magnetic settings - 01 No ( Incomer)
(c) MCCB three pole 440 V, 50-63 Amp,36 KA , Cat No. DNO100D, range 50-63 Amps, with thermal and magnetic settings - 06 No ( For swimming pool and diving pool motors)
(d) MCCB three pole 440 V, 100 Amp,36 KA , Cat No. DNO125D, range 100-125 Amps, with thermal and magnetic settings - 01No ( For APFC Panel)
(e) MCB three pole 440 V, 6-32 Amp,10 KA - 02 No (For blower motors)
(e1) MCB TPN 6-32 Amps, 10 KA C series -03 Nos. ( for dosing pumps)
(f) FASD starter Suitable for centrifugal pump sets -06 No. Each of capacity 25 HP with adjustable over load relay, electronic timer , single phase preventor incl all mounting arrangements. Make : L&T or equivalent as approved by GE
(g) FASD starter Suitable for Blower motor -02 No. Each of suitable capacity with adjustable over load relay, electronic timer , single phase preventor incl all mounting arrangements. Make : L&T or equivalent as approved by GE
h) Motor protection relay for thermal overoad earth fault locked rotor, single phasing current unbalance phase sequence reversal, under current protection for 25HP pump set -06 Nos Make : L&T or equivalent as approved by GE
j) Digital Ammeter 0-200 amps, accuracy class 1.0 including CTs and - 07 No Make : L&T model Vega or equivalent as approved by GE
(k) Digital Voltmeter(0-500V) accuracy class-1.0 - 01 No Make : L&T or equivalent as approved by GE
(l) MCB SPN 20 Amps capacity, 240 V 10 KA , C series -02 No.
(m) MCB SP 06 Amps capacity 240 V 10 KA , C series-03 No.
(n) Multifunction meter 96x96 mm 4410 series, cat No. WL 44100000 make L & T or equivalent make in ABB / siemens-01 no.
Fabricate, Supply install test and commissioning of CPRI approved factory fabricated outdoor type LT panel board suitable for 440 Volt, 3 phase & Neutral , 50Hz supply , floor mounted weather and vermin proof fabricated from MS angle of size 50x50x5 mm as base frame,with 2 mm thick CRCA sheet (Make -Tata/ sail) ( load bearing members 2 mm thick and non load bearing members such as doors partitions etc of thick ness 1.6 mm thick ), with gland plates at bottom with suitable Brass chromium plated glands, with cadmium plated high tensile nut and bolts washers, suitable barrel copper lugs for cable terminations complete, with locking arrangements complete ,sheets bend, folded, cut with CNC machine for the accuracy of diamensions +/-0.5%, duly powder coated ( after minimum 9 tank porecess of pre chemical treatement)with siemens grey colour , with suitable ventilation ,including LED RYB indicators -06 nos on incoming side and ON/OFF/TRIP indications on outgoing side of Incomer, interconnections from bus bars to MCCB's with suitable size copper bus bars, all internal ckt / protection wiring with FRHR 1100 V grade wiring with MCB protection, including terminal adapters, spreader links on incoming
and out going sides of ACB's/ MCCB's complete all as specified and directed and comprising of the following: (for swimming pool under water lights and Flood lights, suction sweeper etc) (a) Bus bar Aluminum -200 A capacity- 04 Nos a , high conductivity, suitable for 415 V, 50 Hz supply including interconnection from incoming, and out going feeders with suitable mounting insulators, heat shrinkable colour sleeves. .
(b) MCCB four pole 440 V, 100 Amp,25 KA , Cat No. DNO-100C, range 80-100 Amps, with thermal and magnetic settings - 01 No ( Incomer)
(c) MCCB 4 pole 440 V, 32-40 Amp,25KA , Cat No. DNO100C, range 32-40 Amps, with thermal and magnetic settings - 02 No ( For Flood light light 2 Ckts)
(d) MCB TPN 440 V, 32 Amp,10 KA - 02 No
(e) MCB SPN 240 V, 20 Amp,10 KA - 02 No
(f) MCB SP 240 V, 10 Amp,10 KA - 02 No
(g) Industial socket 3 phase 32 amps suitable for 415V, 50 Hz supply-02 nos ( for suction sweeper)
(j) Fabrictae, Supply install test and commissioning of CPRI approved indoor type APFC panel board, suitable for 440 Volt, 3 phase & Neutral, 50 Hz supply, IP-42 Deg of protection, floor mounted weather and vermin proof, factory fabrictaed with 2 mm thick CRCA sheet (Make- Tata/sail) ( load bearing members 2 mm thick and non load bearing memebrs such as Doors partitions etc of thickness 1.6 mm thick), with gland plates at bottom with suitable Brass chromium plated glands, with cadmium plated high tensile nut and bolts washers, suitable barrel copper lugs for cable terminations complete, with locking arrangements, sheets bend, folded, cut with CNC machine for the accuracy of diamensions +/-0.5%, duly powder coated with siemens grey colour after chemical treatment with not less than 09 tank process, with suitable ventilation fan at the top, including LED RYB indicators - 06 nos on incoming side and for ON/OFF/TRIP indications on outgoing side of breaker, interconnections from bus bars, all internal ckt/ protection wiring with suitable size FRHR 1100 V grade wiring with 2.5 sqmm and MCB protection with suitable rating and 10 KA breaking capacity
including terminal adapters, spreader links on incoming and out going sides of ACB's/ MCCB's, complete, operations incl Auto manual facility for each bank, with bank ON/OFF indication for each bank incl all internal wiring, CT's , Protection devices, MCBs protection for metering, CT's, PT's Relays contactors, HRC fuses , indication lamp ckts etc with Capacitors of capacity 25 KVAR ( 5,5,5,10,), all as specified and directed and comprising of the following (APFC Panel ) (a) MCCB four pole 440 V, 100-100 Amp 25 KA with thermal and magnetic settings, ,all as per IS-/IEC-60947-2, -01 No ( As Incomer)
(b) Copper Bus Bar of rating 200 amps -04 Nos. on Epoxy insulators incl colour coded heat shrinkable sleeves.
(e) Microproccessor controlled intelligent APFC relay 4 stage,
f) Capacitor duty contactors of suitable capacities for switching capacitors Make : L&T or equivalent as approved by GE
g) capacitors heavy duty of capacity 5 KVAR-03, 10 KVAR-01
Note- i) All CT's PT's meters etc of Accuracy class - I
ii) All signalling shall be microprocessor controlled digital processing logic capable of measurements of KVAR of every cycle of the main wave form.
iii) Current input 1A/5A for load and capacitor feed back with measurement accuracy +/-1%
iv)Capacitors MPP heavy duty suitable for 3 ph 440 Volts supply,Box resin filled IS-13585/ IEC-60931 suiatble for 50 Hz , total watt loss less than or equial to 0.35 w / KVAr,suiatble for switching operations more than or equal to 8000 per year, operating life-150000 hrs.with suitable earthing terminals on both sides.
v) Full load testing of each step,and total operation loss shall be less than 15W / KVAr.
Sch 'A' Part-XII (STAND BY DG SET)
Supply installation, test & commissioning of factory assembled Diesel Engine driven generating set coupled with alternator AC to give output of 250 KVA at a power factor of 0.8 lagging, 415 volts, AC, 3 phase, 4 wire, 50 HZ, 1500 RPM, diesel engine liquid cooled, mounted on common base frame complete with in built fuel tank of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturer's instructions, vibration damper pads, micro processor based relay panel for automatic starting on mains failure, control panel showing all parameters of engine & alternator, sound proof canopy & other accessories etc. and confirming to the under mentioned technical specifications as per specified & directed.
(A) DIESEL ENGINE : Water cooled, turbo charged,06 cylinders in line, 1500 RPM under NTP conditions conforming to IS -4722, BS-5000, IEC-34/1, ISO 8528, BS-5514, ISO-3046 with an overload capacity of 10% for 12 Hrs of continuous operation complete with the following accessories. (a) Radiator with blower fan with guard (b) Pipe coupling for cooling system (c) Corrosion inhibitor coolant (d) Filters for fuel/lube oil (e) Fly wheel housing and fly wheel suitable for alternator with suitable gaurd (f) Engine bearing mechanism in fly wheel housing (g) Shut off coil protection with safety for LLOP /HWT/ Over speed/high and low DC voltage. (h) Dry type heavy duty replaceable paper element air cleaner with restriction indicator and vacuum indicators
(j) Residential silencer. (k) Stainless steel exhaust flexible bellows. (l) Motor driven priming pump. (m) Electric starter motor (n) Battery charging alternator. (o) Exhaust piping made out of 'C' class MS Pipe inclusive of all accessories and hardware, necessary support as per manufacturer’s recommendations to sustain back pressure with rain cap. (p) Mineral wool insulation covered with aluminum sheets for the entire length of exhaust pipe as per manufacturer's recommendations.
(q) First fill of oil, coolant and diesel during commissioning. (r) Interconnecting copper cabling of adequate capacity between batteries and controller. (s) Fuel pipe. C class (t) Self starter 24 volts DC.
(u) Metering equipment for recording (i) Battery voltage and charging rate (ii) Coolant temperature (iii) Lubricating oil pressure (iv) Engine speed (RPM) (v) Engine hours run (vi) Balance of fuel.
(v) Safety as protection control (Trip and indication) (i) High water temperature (ii) Low Lube oil pressure (iii) Low and high speed trip (iv) High and low DC voltage (v) over speed Stop
(w) Base frame : Sturdy fabricated welded construction, channel iron base frame (duly painted ) for mounting engine and alternator as per manufacturer’s design alongwith AVM pads (x) Battery: 02 Nos , 12 Volt, 180 AH maintenance free with leads and terminals (y) Fuel Tank : Built in diesel storage capacity not less than 12 Hrs running of DG set or as per manufacturers recommendations
(B) ALTRERNATOR :250 KVA at 0.8 PF lagging, 415 volts, 3 Phase, 4 wire, 50 Hz at 1500 RPM self excited and self regulated with AVR brushless excitation band of voltage ± 1% of rated voltage from no load to full load insulation class H, self ventilated and conforming to IS4722, BS5000, IEC 34/1, IS0 8528, BS5514, I503046, suitable for above mentioned diesel engine.
(C) ACOUSTIC ENCLOSURE : Factory made acoustic enclosure (canopy) having size as per OEM all as CPCB latest norms
(D) CONTORL PANEL : Control panel made out of 2mm thick CRCA sheets in suitable compartments front openable duly powder coated, weather proof and long lasting finishing including the followings :-
(i) Set of 525 Amps electrolytic copper bus bar for3 phases and neutral mounted over the hygroscopic SMC insulator. (ii) MCCB ,160-400 A, 4 Pole microprocessor based, rupturing capacity 36 KA, 415 volt, 50 Hz with over load and short circuit protections as per approved make – 01 No. (iii) Set of phase indicating lamps showing DG 'ON' and load 'ON'
(iv) Voltmeter digital type 0 to 500 volts range : 01 No (v) Amp meter digital type 0 to 500 Amps range complete with suitable CT”s- 01 No. (vi) MF meter digital type incl recording total and running Hrs complete (vii) Instrument fuses (HRC type) (viii) Bottom gland plates for incoming and outing cable (ix) Circuit diagram plate
(E) Automatic Main Failure (AMF) control panel:- Indoor type, factory fabricated cubical type, free standing, floor mounted, AMF control panel, provided with removable rear door & hinged front door for easy accessibility, fabricated out of not less than 2.0 mm thick CRCA Sheet powder coated CPRI approved comprising of :-
(i) AMF control circuit with 4 pole, MCCB 160-400 Amps-02Nos, micro processor based rupturing capacity 36 KA two Nos. each one for commercial and DG set incoming supply with HRC back up fuse and Contactors heavy duty 500 amps capacity -02 Nos complete with all DC control relays/line voltage monitor (LVM) as per OEM specifications incorporating engine start and stop complete as specified and directed.
Supply, install, test and commission, outdoor type ,LT panel box ,cubicle type, factory fabricated, panel board made with 2 mm thick CRCA Sheet , weather and vermin proof ,floor mounted , IP-52 protection Class 11 tank process ,powder coated in siemens gray colour inside and outside, 3 phase, 4 wire system copper bus bar mounted on hygroscopic insulator housed in separate bus bar chamber covered with R-Y-B and black PVC heat shrinkable sleeve, with 50mmx50mmx6mm angle iron frame with and including PCC 1:3:6 type C2 foundation and covering front and back opening hinged door along with suitable locking arrengement including necessry bus bar tappings, copper control wiring of required size, connecting cable with necessary cable glands, lugs etc, independent chamber to accomodate the MCCBs MCBs,measuring instruments,Bus bar and cable gallary chember ,proper arrangements for ventilation complete with provn for connecting earthing at both sides of panel board and comprises as following:- (DG Panel)
INCOMER i)MCCB 160-400 Amps microprocessor base, 4 Pole, 36 KA -01 No (Incomer from AMF panel) OUTGOING i)MCCB 4 Pole, 415 V, 100-125 Amps 36 KA microprocessor base - 01 No.(Outgoing to filtration plant) ii)MCCB 4 Pole, 415 V, 63 Amps 36 KA thermal magnetic - 02 Nos.(Outgoing to STP & MES office) iii)MCCB 4 Pole, 415 V, 80-100 Amps 36 KA thermal magnetic - 01 No.(Outgoing to swimming pool panel) iv)MCCB 4 Pole, 415 V, 25-32 Amps 25 KA - 02 No.(Flood light panel & Street light panel)
METERING & INDICATION i) Ammeter, Digital type, with suitable CTs - 01 set ii) Voltmeter, Digital type - 01 set iii) R-Y-B phase indicating lamp- 03 Nos Note 1- in front of LT indoor panels provision of insulating mat confirming to IS- 15652-2006 with class A 2.0 mm thick shall be provided and rate of the same shall be deemed to be included in the quotes rates of respective items.
Sch 'A' Part - XIII ( Pile Founation)
Erecting pile equipment of any type complete with all accessories centering in position and removing on completion of each pile and MS liner.
Boring/drilling into any type of soil for 600 mm dia cast-in-situ piles using DMC method (Direct mud circulation) using Betonies slurry all as required getting out and disposal of soil to a distance outside MD land and depositing at a place all as specified and directed by Engr-in-Charge
Boring/Drilling into Soft//disintegrated rock for 600 mm dia cast-in-situ piles using DMC (Direct mud circulation) using Betonies slurry all as getting out and disposal of soil to a distance outside MD land and depositing at a place all as specified and directed by the Engr-in-
Boring/drilling into Hard Rock for 600 mm dia cast-in-situ piles using DMC method (Direct mud circulation) using Betonies slurry all as required getting out and disposal of soil to a distance outside MD land and depositing at a place all as specified and directed by Engr-in-charge
Note for 2 to 4 (a) Reinforced controlled cement concrete, reinforcement will be measured and paid separately (b) Soil mixed with betonies slurry (obtained from boring) shall be disposed off outside MD land and depositing at a place as directed by Engr-in-charge. The unit rate quoted against item 2 to 4 shall interalia be deemed to include this operation and no extra payment shall be admissible on this account (c) Boring of piles shall be measured and paid from marked average ground level to bottom pile.
M & L for RMC M30 design mix concrete as per IS 456 of 2000 using 20 mm graded stone aggregate in pile cap and piles of any length/size including cutting and knocking down waste concrete complete all as shown on drg Note : RCC will be measured and paid from cut off level and rate quoted shall be inclusive of cutting and knocking of RCC waste above cut off level.
S & F CRS steel bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as specified & as directed.
S & F CRS steel bars as in stirrups 5 to 10 mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as specified & as directed.
Mild steel liner 6 mm thick for bored cast-in-situ concrete piles as required including applying 140 micron DFT coal tar epoxy protective coating all as shown on drawing and as specified and directed by Engr-in charge.
M & L Testing of pile (initial load test) all as specified and indicated on drawing incl bringing at site all testing materials & equipments complete & removing of the same after completion of satisfactory testing for 600 mm dia pile.
M & L Testing of pile (routine load test) all as specified and indicated on drawing incl bringing at site all testing materials & equipments complete & removing of the same after completion of satisfactory testing for 600 mm dia pile.
M & L Testing of pile (Integrity test) all as specified and indicated on drawing incl bringing at site all testing materials & equipments complete & removing of the same after completion of satisfactory testing for 600 mm dia pile.
Mukund Enterprises Private Limited
Hariom Projects Pvt Ltd
United Sales Corporation
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid