Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 CrAccepted-AOC | ₹3.0 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹3.0 Cr+₹3.7 L (1.24%)Rejected-Finance MANSINGHDIH BENGABAD GIRIDIH JH 815312 | GIRIDIH | JHARKHAND | 815312 | ₹3.0 Cr+₹3.7 L (1.24%) | L2 | Rejected-Finance L2 |
| 3 | L3₹3.0 Cr+₹4.1 L (1.39%)Rejected-Finance BOKARO | JHARKHAND | 825102 | ₹3.0 Cr+₹4.1 L (1.39%) | L3 | Rejected-Finance L3 |
| 4 | L4₹3.3 Cr+₹29.6 L (9.99%)Rejected-Finance | ₹3.3 Cr+₹29.6 L (9.99%) | L4 | Rejected-Finance L4 |
| 5 | Rejected-Technical ASHIK NAGAR DHANBAD | DHANBAD | JHARKHAND | 818142 | - | - | Rejected-Technical NON RESPONSIVE |
Tender Value
Refer Docs
EMD Value
₹3.7 L
Closing Date
10 Jan 2024, 5:00 pmClosed
Nodal Officer
e-Procurement Cell, Jharkhand State Building Construction Corporation Ltd., Beside Jharkhand Mantralaya, Dhurwa, Ranchi-834004.
Construction of 50 Bedded Girls Hostel in Rajkiye Homeopathic Medical College and Hospital, Parspani under Godda District
2023_JSBCC_79183_1
JSBCCL/80/2023-24
Open Tender
Civil Works - Buildings
Item Rate
270 days
Godda
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
₹3.7 L
29 Nov 2024
20 Dec 2023
12 Jan 2024
20 Dec 2023
10 Jan 2024
20 Dec 2023
Amount
CIVIL WORK
EARTH WORK
Earth Work in excavation in Foundation Trenches in Ordinary soil (vide classification of soil item -B) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I
Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume).
Extra for each subsequent lead upto 25 M beyond the initial lead of 50 M (Maximum upto 150M lead by head load) as per specification and direction of E/l.
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer In charge (Mode of measurement compacted volume)
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diaMTR.er holes and plugging with cement mortar 1:2 (1 cement : 2 Coarse sand) to match the existing floor
With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
Providing P.C.C. M-75with nominal mix of (1:4:8) in foundation with approved quality of stone MTR.al grade - III (50 mm to 25mm size) clean coarse sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, taxes and royalty all complete all complete as per building specification and direction of Engineer-in-charge.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing 25 mm thick damp proof course with cement concrete M-150 with nominal mix of (1:2:4) with approved quality of stone chips of 20 mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including, screening, shuttering and mixing cement concrete in mixer with 5% cico or any other approved water proofing compound and placing in position, striking, curing, taxes and royalty all complete as per building specification and direction of E/l.
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using fly ash and cement content as per approved design mix, including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate / retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. NOTE- (1) Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately.
All works uptp plinth level
All works above plinth level upto floor V level
Add for using extra cement in the items of design mix over and above the specified cement content therein.
Foundations, footings, bases for columns, etc for mass concrete
Suspended floors, roof , landings , balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, abutments, Posts and struts
Stairs, ( excluding landings ) expept sprial staircase
Providing TMT steel reinforcement as per approved design & drawing
8mm (TMT Fe500)
10mm (TMT Fe500)
12mm (TMT Fe500)
16mm (TMT Fe500)
Providing Tor steel reinforcement of 20 mm, 25mm, 28mm, 32mm dia bar as per approved design and drawing
25 mm dia TMT bar Fe 500
Providing designation 75 B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.
Providing Designation 100A B/W with Fly Ash Lime Brick (FALB) conforming to IS 12894-1990 (9"x4.5"x3") in cement mortar (1:6) in Superstructure with clean coarse sand of F.M. 2 to 2.5 including 10mm thick mortar joints,cost of screening, raking out joints to 15 mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.
Providing Designation 100A 112 mm thick reinforced B/W with Fly Ash Lime Brick (FALB) conforming to IS 12894-1990 (9"x4.5"x3") in cement mortar (1:4) in Superstructure with clean coarse sand of F.M. 2 to 2.5 including the cost of screening, raking out joints to 15 mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.
Extra for providing & placing in position 2 no 6mm dia ms bar every 3rd corse of half brick masonary
Supplying, fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with one sides teak decorative and another side commercial veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with Aluminium fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/l.
Supplying, fitting and fixing 35mm thick solid core type decorative double leaf flush door shutter with one sides teak decorative and another side commercial veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with Aluminium fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/l.
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1mm thick
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete :
Providing, fitting and fixing oxidised iron fitting of approved quality and make to door and window all complete as per building specification and direction of E/I necessary screws etc. complete.
300 mm sliding door bolt
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Twin rubber stopper
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36KGto 80KGand door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.
With stainless steel cover plate minimum 1.25 mm thickness
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge
Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineerin- charge
Extruded section profile size 48x40 mm
24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws.
The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter).
Supplying, fitting and fixing oxidised iron fittings of approved quality and make to doors and windows all complete as per building specification and direction of E/l.
100mm door handle with plate.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately):
For fixed portion
Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 5.50 mm thickness
Filling the gap in between aluminium frame and adjacent RCC/Brickwork/ Stone Work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge
Upto 5mm depth and 5mm width
Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to be paid for separately).
Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately).
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of required thickness having 60 minutes of fire resistance both integrity & radiation control (EW60) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm.
Supplying, fitting and fixing M.S. grill with M.S. grills made of 20x6mm M.S. flats or 16mm square bars fitted on 25x25x6mm M.S Angle frame including cost of fabrication , providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/l. (where steel is not supplied by the deptt.)
Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 1.60 mm thickness,including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm,pressed mild steel welded or rigidly fixed together by mechanical means,including M.S. pressed butt hinges 2.5 mm thick with mortar guards,lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:
Fixing with adjustable lugs with split end tail to each jamb
Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately)
Supplying, fitting and fixing callapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2 mm at 100mm. centres and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40x40x6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangements, stoppers, handles, including applying a priming coat of red lead paint, carriage , hoisting and taxes all complete as per building specification and direction of E/l.
Providing and laylng Doublecharge vitrrfied floor tiles in diiierent sizes (thickness to be i specrfred by the manufacturer) with water absorption less than 0.08% and conforming to lS 15622 / ISO 13006 of approved make in all colours and shades laid on 20mrn thick cement mortar 1 4 (1 cement:4 coars sand) jointing with grey cement slurry @ 3.3 kg/ sqm including I grouting the joints with white cement and matching pigments etc complete Size of tile 600x600 mm
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and fixing granite 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for flooring, kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
Granite of any colour and shade Area of slab over 0.50 SQM
Providing edge moulding to 18 mm thick marble/granite stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
Granite work
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
Providing and laying 1st quality Ceramic glazed wall tiles thickness to be specified by the manufacturer) in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointed with white cement including rubbing polishing and cost of curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
In 75x75 mm deep chase
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Roof/Terrace Water proofing:
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:
(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Toilet/Kitchen Water proofing: Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.
(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry
Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
Providing 19 mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 SQM) over and including priming coat of exterior primer applied @ 2.20kg/10 SQM
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and m anufacture, including applying additional coats wherever required, to achieve even shade and colour.
Two coats
SAND (UPTO 10KM LEAD)
CHIPS (UPTO 22KM LEAD)
BRICKS (UPTO 1K+7P LEAD)
Local Sand (up to 3 km lead )
PLUMBING WORK
Supplying , fitting and fixing vitreous white glazed earthen ware I.W.C of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I 'p' trap 15 liters C.I.pull and let go flushing cistren of names or other I.S.S. equivalent make , complete with all fitting , C.I.or C.C. brackets 32mm alkathene/P.V.C telescopic flush , pipe about 2 M long with one brass coupling and clamps GI ,chain and pull including supplying and fixing a pair of vitreous white glazed earthenware ware footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weight not less thane 50grms. 15mm P.V.C. connection pipe 450 mm. long and the exposed pipe and cistern with two coats of approved paint over a coats of red oxide primer etc. all complete as per specification and direction of E/I.
(A) 580 mm. long
(C) With 10 lit. low level PVC Cistem
Supplying, fitting and fixing 40mm high vitreous white glazed earthen E.W.C. with ‘p’ trap of parry hindustan or any other approved I.S.S. make including supplying and fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I.handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450grams 15mm P.V.C. alkathene pipe 45cm. long with brass coupling at both ends and white/black plastic solid state seal and lead of commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide priming, all complete as per specification and direction of E/I.
(ii) E.W.C. with 'S' trap
(B) 12.5 lit. low level PVC Cistem
Supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on painted C.I. or R.S. brackets 32mm C.I.brass waste, 15 mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I.
Supplying fitting and fixing white glazed fire’s clay sink of approved make with overflow arrangements supported on C.I. or R.S. painted brackets 40mm. dia C.P.brass waste with C.P.brass chain and rubber plug 40 mm dia P.V.C. waste pipe about 750mm long with brass coupling at one endand 15mm C.I. body brass spindle bib cock of approved quality of weight not less than 450grams. including cutting wall and making good the same etc. all complete as per specification and direction of E/I.
(i) Kitchen sink 600 mm x 450 mm x 250 mm
Providing and fixing male ended 15mm dia brass bib cock of approved quality (Wt. not less than 350gms.) with extra socket all complete as per specification and direction of E/I.
Providing and fixing N.P/C.P. brass /P.V.C. porcelain shower rose of 15mm inlet etc. all complete as per specification and direction of Engineer - in -Charge.
(c) 125mm dia P.V.C shower
(b)Mirrors of 6mm thick plate glass bevelled edge mirror including C.P. brass revolving fittings 3mm ply wood board and C.P. hinges to fix with mirror.
(i) 600mm x 450mm size
(c) (i) C.P. brass towel rail 20mm x600mm with bracket container
(c)(iii) C.P. brass liquid soap container
Provinding and fixing wash basin wih C.I brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls whereever required :
White Vitreous China Wash basin size 550x400 mm with a 15mm CP Brass single hole basin mixer
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in charge.
Providing & fixing PVC waste pipe for sink including PVC waste fitting Complete
Flexible Pipe
32mm Dia
Providing and fixing toilet paper holder :
C.P. brass
Providing and fixing PTMT Bottle Trap for Wash basin.
Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms.
Providing & fixing PTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealed fittings arrangement of approved quality and colour weighing not less than 88 gms
Providing and fixing uplasticised PVC connection pipe with brass unions :
45 cm length
15 mm nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore.
15 mm nominal bore
Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms
Providing & fixing soap dish holder of approved design.
Providibng and fixing straight type Macfit single body push fit type WC pan connector with factory supplied spring loaded seal guard of McAlpine, UK with integral single mould sealing fins made of flexible EVA body, including bush/adaptor for use with C.I. Pipe as supplied with the pan connector.(supreme/Prince)
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing complete as required.
Providing and fixing C.P concealed four way diverter with thermostatic mixer with shut off valve and diverter, including cutting and making good the walls, wherever required. (Make:- Jaquar - Four way diverterKUB-35421, Thermostatic mixer 35671 or Equilent)
Providing,Fixing wall mounted Double Coat hook on door complete. ( MAKE-1: JAQUAR, MODEL NO. COAT HOOK : AKP-CHR-35761P ROCA MODEL NO : T6007A1.
Providing, Installing & fixing storage type water heater of approved shade with copper container, glasswool insulation,stove enamelled M.S jacket, thermostatically controlled inner heater with pilot neon lamps, 15mm inlet stop cock valve, on inlet connection, 15mm dia C.P flexible connection pipe in inlet & outlet suitable for working pressure of 8 kg/sqcm complete as required.
Capacity 25 litres
Capacity 35 litres
Providing, Fixing,testing and commissioning storage type water cooler of the following capacity, I.S.I marked, stainless steel front panel, CP brass push cock, inlet float valve with all plumbing and electrical accessories, inlet, outlet, overflow and PVC drain out connection to FD complete as required.
Cooling capacity 40 Lts./hr
Storage capacity 80 Lts.
Providing, Fixing, testing and commissioning of UPVC pipe SWR type 'B' conforms to IS : 13592-1992 with all fittings such as bends, tees, elbow, 'Y', offset, cleaning pipe door, clamps and steel structural supports etc. including cutting the floors, walls and making good the same in cement concrete 1:2:4 & cement mortar 1:4. The wall thickness of pipe and technical characteristic conforms to IS : 13592-1992 type 'B'. The fitting dimension conforming to IS : 14735-1999. The jointing to be completed with rubber ring joint/solvent weld joint.
75 mm diameter pipe
110 mm diameter pipe
Providing, Fixing, testing and commissioning of UPVC 'P' trap/floor trap/urinal trap of self cleansing design with or without horn conforming to IS : 14735-1999 including setting with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 hard stone ballast 20 mm nominal size) cutting and making good the walls & floors.
110 mm (OD) x 110 mm (OD)
Providing, fixing & testing uPVC pipes, conforming to IS 4985 class 3 (6 kg/cm2) including injection moulded fittings, jointing with solvent cement, cutting and making good the floors and walls and jointing to trap/waste pipe, complete of outer dia. (Indirect waste)
40 mm diameter pipe
50 mm diameter pipe
Providing, Fixing UPVC floor drain including all fitting and accessories fixed in cement mortar complete in all respect. 110 mm OD x 63 mm OD
Providing and fixing PTMT grating of approved quality and colour.
125 mm nominal dia with 25 mm waste hole
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand) including testing of joints etc. complete.
150 mm. dia. RCC Pipes
250 mm. dia. RCC Pipes
Construction brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand 4 graded stone aggregate 20mm nominal size) foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design.
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :
0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Providing and fixing square mouth SW gully trap class SP-1 complete CI grating brick masonry chamber and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.7 kg. as per standard design.
100x100mm size P type
With common burnt clay F.P.S (non modular) bricks of class designation 7.5.
Providing, fixing and testing of uPVC SWR inlet fittings with two or three saddle inlets of 40, 50 or 75 mm size, fabricated from 110 mm outer dia uPVC pipes and fixed to uPVC traps with solvent cement joint complete in all respect.
Providing & fixing uPVC clean out plug with suitable opening with threaded uPVC socket fixed to uPVC pipe joints as required complete in all respects.
110 mm dia
160 mm dia
Constructing Oil & Grease Chamber size 2400x1000mm internal size of 1000mm depth in brick work of class 75 with cement mortar (1:5) Inside 12mm thick with cement mortar 1:3 with floating coat of neat cement and rough plaster on outside, RCC top slab with 500mm dia medium duty manhole cover with frame (weight of cover 58 kg. & weight of frame 58 kg.), 150mm thick foundation concrete (1 :4 : 8), necessary excavation, dewatering, refilling, watering, ramming and removing the surplus excavated material and making good the same complete as required.
Providing and fixing Gun metal full way valve of approved qualtiy, all complete as per specification and direction of E/l
(a) 15 mm dia wt not less than 300 gms
(a) 20mm dia wt not less than 400 gms
(a) 25 mm dia wt not less than 500 gms
(a) 32 mm dia wt not less than 700 gms
(a) 40 mm dia wt not less than 1kg
(a) 50 mm dia wt not less than 1.5kg
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc.
15 mm nominal outer dia Pipes
20 mm nominal outer dia Pipes
25 mm nominal outer dia Pipes
32 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on Wall
15 mm nominal outer dia Pipes
20 mm nominal outer dia Pipes
25 mm nominal outer dia Pipes
32 mm nominal outer dia Pipes
40 mm nominal outer dia Pipes
50 mm nominal outer dia Pipes
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Butterfly Valves :: - Providing, fixing, testing & commissioning of wafer type cast iron butterfly valves conforming to BS 5155 & IS 13095 tested to 15 Kg/Sq.cm pressure for maximum working pressure of 10 bar (PN 10) including all fitting and accessories (Drain, water meter for OH Tank/Riser).
65 mm dia
80 mm dia
NON-RETURN VALVE with dual plate of CI body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating as specified.
65 mm dia
Providing and fixing insulation with thermaflex elastomeric nitrile rubber sheets complete with plastering of 20 mm thick insulation with thermaflex elastomeric nitrile rubber sheets for hot water & cold water pipes exposed and chased to sun complete with plastering.
15mm (9 mm thickness)
20mm (9 mm thickness)
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.
All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.
All types of soil
300 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.
200 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
200 mm nominal size dia
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineerin-charge.
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge.
200 mm nominal size dia having minimum wall thickness 5.40 mm
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:
200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.
200 mm dia
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).
200 mm dia
FIRE FIGHTING
PUMPS
1.NOC from fire authority shall be in the scope of Contractor . Only fee paid to the fire authority shall be reimbursed against the submission of the receipt and nothing shall be paid extra.
2. All the Fire Fighting works shall be done in compliance of Fire Fighting authority requirement.
Pump shall be capable of furnishing not less than 150% of rated capacity at a head not less than 65 % of rated head. The shut off head shall not exceed 120% of rated head.
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump).
Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520.
Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325.
M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.
Suitable cement concrete foundation duly plastered and with anti vibration pads.
900 lpm at 35 m Head
CONTROL PANELS Supplying,Installation,testing & commissioning of dust & vermin proof double door with canopy type taperd roof wall / floor mounted compartmentlised feeder piller type cubical control Panel for fire fighting terrace pump of front area not less than 1.0 Sqmtr. and depth not less than 300 mm, made out of 2mm thick CRCA sheet with 100 Amp. 4 strip aluminium bus bars with front openable door & locking arrangement, interconnection, control wiring, intrigation with pressure switch i/c suppying & fixing following switchgears & control gears/starters etc. as required.
Incomming
100 Amps. 16ka breaking capacity 4 pole MCCB-1 Nos.
Set of 3 phase indication lamp-1 Set
100 Amps. 4 strip insulated bus bars-1 Nos.
Outgoing
63 Amps. 10ka breaking capacity 3 pole MCCB--2 Nos.
Suitable HP fully automatic Star/Delta Starter with over load protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation.- 2 Set
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. It should be complete as per specifications & directions of Engineer-in-charge.
4 x 25 sqmm ( 28 mm )
3.5 x 50 sqmm ( 35 mm )
3 X 10 sq. mm (22mm)
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. 150 mm width x 50mm depth x 1.6 mm thickness.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supplying & laying one number XLPE insulated PVC sheathed Aluminium Conductor armoured UG cable of 1.1 KV grade Conforming to IS 7098/1988 with upto date ammendment of following size in the existing RCC/HUME/ METAL /GI /CI /Stoneware/DWC pipe/ masonary Open Duct/ cable tray/ open in air etc. as requred.
4 core, 25 sq.mm. Aluminium Armoured
3.5 core, 50 sq.mm. Aluminium Armoured
3 core, 10 sq.mm. Aluminium Armoured
Supply and fixing in position 1 m wide Insulation mat made of elastomeric polymers Material (Class -A) of 415V grade as per IS 15642-2006 . Thickness of insulation mat shall be not less than 2 mm to withstand 1.1 KV dielectric strength AS PER IS 15652 : 2006. It should be complete as per specifications & directions of Engineer-in-charge.
PIPES & ACCESSORIES Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. (PDowncomer/Floor)
25 mm dia
100 mm dia
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
65 mm dia
80 mm dia
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 100 mm dia
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 1258520 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 40 m
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Gun metal
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :
2 way-100 mm dia M.S. Pipe. (FOR FHC )
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
Providing and fixing standard fireman's axe with heavy insulated rubber handle conforming to IS: 926 complete.
Providing & Fixing of MS door made up of 16 gauge MS Sheet capable of accommodating fire hose reel, landing valve, hose pipes, fittings, 1 No. CO2 & 1 No. Dry podwer type portable fire extinguishers & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with one coat of primer & two coat of finished stove enamelled post office red colour paint & "FIRE HOSE" written on front. (Approx. size of door: 2100 mm HEIGHT, WIDTH OF DOOR AS PER SHAFT SIZE )
Providing, Fixing, testing and commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 deg. C temperature, working pressure 11 Kg/cm2 and test pressure 16 Kg/cm2 to provide relief from stresses at pipe flanges.
150 mm dia
80 mm dia
Supply, fixing, testing and commissioning of screwed type brass/bronze lever operated ball valve of full flow with stainless steel ball (AISI 304 & spindle AISI 410) with setting & gland of superior quality having minimum working pressure of 16 kg/sqcm. 25 mm Dia
FIRE EXTINGUSHER
Providing, storing, handling, shifting, installation, testing and commissioning of halon free portable fire Extinguishers as described below:Concealed work, including cutting chases and making good the walls etc.
Supply & Fixing of 6 Kg ABC MAP-50% Powder based Fire Extinguisher, Applicable Fire Class A, B & C, EPDM Rubber Hose, NRV Valve and Helium Leak Detection Tested, Internal Coating - Epoxy Powder and External Pure Polyester Powder Coated (UV resistant), IS 15683:2018 Marked. Location : Open General Area, Inside FHC,
Providing and Fixing of CO2 Portable 4.5 Kg Fire extinguisher, Carbon-Dioxide type Flat base Horn Including Valve, High Pressure Rubber Wire Braided Discharge Hose of not less than 10 mm dia. & complete in all respects including initial fill with CO2 Gas confirming to IS:15222. and IS 15683:2018 Marked. Location : Inside Electrical Room, Pump Room,
Providing and Fixing of Portable 4kg Clean Agent HFC-236fa Fire Extinguisher, Gas UL Listed under EPA SNAP, EPDM Rubber Hose, NRV Valve and Helium Leak Detection Tested, Internal Coating - Epoxy Powder and External Pure Polyester Powder Coated (UV resistant), Suitable for Class A,B and C & Electrically Started Fires, Conforming to IS 15683:2018 Marked. Location : General Office Area, Inside of Critical Rooms i.e. Server Room, UPS Near Rooms, Fire Control Room etc.
Main Building Signage :-Laser Cut Acrylic Letters with Stain less Steel sides along with Korean Led Lights, Letters will be directly fixed over the Main Facade. (20 Feet By 3 Feet
Reception : Back wall signgae ,Laser Cut 5 mm Acrylic Letters with Pasted over 5 mm Acrylic Sheet with 6 studs (4 Feet by 3 Feet
Reception ,Hanging Signge Double Sided :- Laser Cut 5 mm Acrylic in desired color with Plotter Cut Vinyl Letter Double Side as required ( 4 Feet by 2 Feet)
Room : Door Signage : Laser Cut 5 mm Acrylic Signage with Plotter Cut Vinyl letters pasted above & Desired color vinyl pasted on Back ( 4 Inch18 Inch by
Waiting Area ; Hanging Signge Double Sided : -Laser Cut 5 mm Acrylic in desired color with Plotter Cut Vinyl Letter Double Side as required (4 Feet by 2 Feet
Toilet ,Door Signage :- Laser Cut 5 mm Acrylic Signage with Plotter Cut Vinyl letters pasted above & Desired color vinyl pasted on Back ( 4 Inch18 Inch by
Staircase:,Door Signage ; Laser Cut 5 mm Acrylic Signage with Plotter Cut Vinyl letters pasted above & Desired color vinyl pasted on Back (4 Inch18 Inch by)
Electrical Room;Door Signage,Laser Cut 5 mm Acrylic Signage with Plotter Cut Vinyl letters pasted above & Desired color vinyl pasted on Back ( 4 Inch18 Inch by
Toilet Female,Door Signage ;Laser Cut 5 mm Acrylic Signage with Plotter Cut Vinyl letters pasted above & Desired color vinyl pasted on Back ( 4 Inch18 Inch by)
Store Room,Door Signage :Laser Cut 5 mm Acrylic Signage with Plotter Cut Vinyl letters pasted above & Desired color vinyl pasted on Back : 4 Inch18 Inch by
ELECTRICAL WORK
SUB-HEAD I : 415V MAIN DISTRIBUTION BOARDS
Design, fabrication, assembling, wiring & supply, installation, testing & commissioning of Distribution Panels fabricated out of 2mm thick for structural members (Load bearing members) and 1.6mm thick for door and covers (Non load bearing members) CRCA painted sheet steel in cubicle formation with reinforcement of suitable size angle iron, channels, T irons, flats wherever necessary for large meter boards. Cable gland plates shall be provided at top and bottom both and windows for meter reading, locking arrangement (pad-lock & seal) with wiring upto KWH meter & meter to MCB shall be done by using adequately rated flexible single core copper wire. The boards shall be treated with all anticorrosive process before painting as per standards with final approved shade of powder coated as approved, 2 nos. earthing terminals shall be provided for all panels. The boards shall be suitable for 415 V, 3 phase, 4 wire, 50 Hz supply system. Boards shall be fabricated in length, height, depth etc to match with site conditions.
An approval shall be taken for each panel before manufacturing. Galvanised hardwares with zinc passivation shall be used in fabrication of boards.
Note: The following provisions shall be required to be made in the switchboard detailed below
The Switchboard shall have provision for entry of all PVCA cables from the top/bottom as required.
All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The busbar insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used.
Suitable tinned copper extension links for incoming/outgoing cables shall be provided wherever required
Positive isolation of all breakers.
All fault level breaking capacity indicates shall be IC.S value at 415 volts (ICS = ICU = ICW = 100%).
Space Heater/ light/air filter shall be provided for each vertical compartment
Padlocking facility shall be provided on all outgoing feeders.
All ACB’s/MCCB's shall have all standard accessories such as CT’s, Arc Chute, Safety Shutters etc.
Link and drops from ACB/MCCB shall be designed for full rated current of ACB/MCCB ratings at same current density as of Main Bus Bar
2 nos. GI earth strip throughout the panel.
MDB-1 LIGHTING & POWER
Incoming #1
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
250 Amp, 35 KA
MDB-1 Panel body enclosure
Metering, Indication & Protection:
Digital Volt Meter 0-500 Volt 3 Phase class 0.5
Digital Amp. Meter 0-500 Amp. 3 Phase class 0.5
1 Sets supply available indicating lamps with control MCBs.
R-Y-B and ON/OFF indication lamps for incomer
Bus Bar:
400A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 35 kA. Neutral busbar shall be of 100% capacity.
Outgoings
12 Nos. 25-100A, 4 Pole MCCB 16KA with fixed thermal magnetic setting.
MDB -1 LIGHTING & POWER as described above as per SLD
SDB-1 KITCHEN
Incoming #1
80A, 4 Pole MCCB 16KA with fixed thermal magnetic setting.
SDB-1 KITCHEN Panel body enclosure
Metering, Indication & Protection:
Digital Volt Meter 0-500 Volt 3 Phase class 0.5
Digital Amp. Meter 0-500 Amp. 3 Phase class 0.5
1 Sets supply available indicating lamps with control MCBs.
Bus Bar:
100A, Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 10 kA. Neutral busbar shall be of 100% capacity.
Outgoings
6/32Amp. Rating DP, MCB C Series,10ka breaking capacity.
50/63Amp. Rating DP, MCB C Series,10ka breaking capacity.
6/32Amp. Rating TPN, MCB C Series,10ka breaking capacity.
SDB -1 Kitchen (Power) as described above as per SLD
LT CABLES
Supplying of following 1100 volt grade XLPE insulated PVC sheathed aluminium conductor armoured cables as per specification as required.
3.5c x 50sq. mm.
3.5c x 35sq. mm.
3.5c x 25sq. mm.
4c x 16sq. mm.
4c x 10sq. mm.
4c x 6 Sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ STONE WARE / METAL pipe/ Cable Trays as required.
Upto 35 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3.5 core 50 sq. mm.
3.5 core 35 sq. mm.
3.5 core 25sq. mm.
4c x 16sq. mm.
4c x 10sq. mm.
3c x 6sq. mm.
Wiring for Light point / Fan point / Exhaust Fan point / Call Bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit , with modular switch ,modular plate ,suitable GI box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as required.
a) Group - C
Wiring for twin controlled light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit , with 2 way modular switch ,modular plate ,suitable GI box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as required.
Wiring with 2 x 2.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 1 No. 2.5 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.( For 5A primary Socket)
Wiring with 2 x 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 1 No. 1.5 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.( For 5A Secondary Points)
Wiring for light / power plug point with 2 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 1 No. 4 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.( For 16A Socket)
Supplying and fixing suitable size GI box with modular plate and cover in Front on surface or in recess ,including providing and fixing 3 pin 5 / 6 amps modular socket outlet and 5 / 6 amps modular switch,connection,painting etc.as required.
Supplying and fixing suitable size GI box with modular plate and cover in Front on surface or in recess ,including providing and fixing 6 pin 15 / 16 modular socket outlet and 15 / 16 amps modular switch,connection,painting etc.as required.
Supplying and fixing modular type 20 amps A.C. unit box with ON/OFF MCB on surface or in recess complete with connections, testing and commissioning etc as required
Geyser/ Toilet Inline Fan point consisting of following :- - 1 No. 6 pin No 6/16A Modular Socket in 2 Module Box with modular Plate near Geyser - 1 No 6/16A Modular Switch in 2 Module Box with Modular plate near entry at switch board level - Wiring between Socket and Switch board with 3 Nos. 4.0 Sq. mm Cu Wire in conduit including connections at both ends. Breakup of said item is as follow:-
S/F 2 Module modular GI Box base and cover plate.
S/F 2 Module modular base and cover plate.
S/F 2 16A modular type switch.
S/F 2 16A modular type 6 pin socket.
FINAL DISTIRIBUTION BOARD
Supplying installation, testing and commissioning of surface-recess mounting horizental type three pole and neutral,prewired, sheet steel, MCB distribution board 415 volt, dust protected and powder painted ,inclusive of 200 amps tinned copper busbar, common netrul link, earth bar, din bar for mounting MCB detachable gland /knock out plate, and with built in loose wire box, and superior make terminal connectiors for all adequate size of FR PVC insulated copper conductor upto the terminal of following way with double door as required
A. TP&N D.B ( HORIZONTAL TYPE)
i)6 way (4+18), double door , Horizontal type
63 Amps 4P MCB Isolator
63 Amps DP RCCB
6-32 Amps SP MCBs as outgoing
B. TP&N D.B ( VERTICAL TYPE)
8 way (8+24), double door , vertical type
63 Amps 4P MCB Isolator
63 Amps DP RCCB
6-32 Amps SP MCBs as outgoing
Supplying and fixing following way prewired SP&N MCB distribution board of steel sheet for 240 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.
SP&N D.B (Double Door)
40 Amps 2P MCB -1Nos
40 Amps 2P RCCB -1Nos
6-32 Amps SP MCBs as outgoing
Exhaust fans
Supply and installation of 300 mm, 230 v A.C. exhaust fan in the existing opening including making good the damage, connection testing, commissioning etc as required.
Extra for fixing the louvers/ shutters complete with Frame for a exhaust fan of all sizes
S.I.T.C of floowing rating reccess/surface mounted LED round/square shape Down light luminarie with pressure die cast housing for single phase supply voltage. Luminarie shall be confirm to IS:10322 part-5/section-2 or IEC:62722with all neccssary acc$sories as required
12W LED Round Down Light
2'x2' 36W LED Panel Light
LED Batten (20/22W)
4 to 6Watt LED Foot lamp/ LED step light cast aluminium body and IP:54 protection
LED Batten (10/12W)
Supply and fixing of stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 1 Or 2 Module size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
Supplying and fixing 1200MM Dia sweep ceiling etc. as required. BLDC
Earthing with G.I. Earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. (With charcoal or coke and salt) complete as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Providing, fixing, connecting and testing of following pair solderless telephonetag block, with powder coated box (Krone make ) of required size box with hinged lockable cover and clamps for dressing of wires etc as required.
20 Pair box
Supply and laying of following 0.61mm dia annealed tinned copper conductor PVC insulated and PVC sheathed unarmoured telephone cable in existing conduit in concealed/ surface system complete as required
20 pair Cable
2 pair Cable
Providing, fixing, connecting, testing and commisssioning of zinc passivated box with moulded plate in recess or on surface moulded type with following including all necessary materials etc. as required.
48 Port layer-2 Switch
2 Pair telephone cord outlet (RJ-11)
telephone socket outlet
TV antina Socket outlet
TV antina Socket outlet
Supply and fixing 1 or 2 module ( 78mm X 78mm X 45mm) GI Box along with modular base and cover plate for modular switches in recess etc as required
Supply and fixing of Computer terminal (RJ-45) outlet in existing box with modular plate
Supplying and fixing of following size medium class PVC conduit alongwith the accessories in surface / recess including painting in case of surface conduit or cutting and making good the same in case of recessed conduit as required as per specification.
25mm dia
Providing and fixing of UTP CAT 6 Computer LAN Cable With Star Separator and for Telephone in existing conduits .
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of steel conduit alongwith the accessories in surface / recess including painting in case of surface conduit or cutting and making good the same in case of recessed conduit as required as per specification.
25mm dia M.S. conduit.16 SWG M.S. conduit
32mm dia M.S. conduit.16 SWG M.S. conduit
Supplying and laying of following sizes FRLSLS PVC insulated single core copper wire in existing conduit complete as required.
2x1.5 sq mm
2x2.5 sq mm
Supplying, installing, testing and commissioning of the following as per specification complete with junction box, as and where required.
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
Analogue addressable rate of rise cum fixed temperature thermistor type heat detector with mounting base, address switch complete as required.
Addressable type Manual Call Point complete as required.
Addressable Hooter cum strobe complete as required.
Analogue addressable Fault Isolators for isolating shorted, de-wired and loose circuits between two successive Fault isolators with automatic resetting arrangement. (max. 20 devices for one fault isolators).
Analogue addressable, automatic commandable Control Switches for switching on/off various ventilation fans, pressurisation fans, zones of speakers etc. and other Fire operation related devices and complete as required.
Addressable Input Card/monitor module for connecting to Flow Switch etc.
Panel shall have programmable switch plates for controlling horn strobe zones/AHU shut off etc. from panel itself. Panel shall have inbuilt autodialer with minimum 6 line output. Panel shall have its own master fire fighting telephone/audio control/command centre.
The Panel shall also have Logic hardware and software built into it for initiating specific AHU tripping, time delay operation of strobe, subsequent operation of electronic speakers, and finally hooters.
2 loop panel
PUBLIC ADDRESS SYSTEM :
Supplying, installation, testing & commissioning of 6 inches dia, 2 watts, 70/100 volts ceiling speaker complete as required.
Fire Fighter Telephone System :
Portable UL listed fire phone handsets in a suitable enclosure.
CENTRAL CONTROL STATIONS :
Supplying, installing, testing and commissioning of the Central Control Stations consisting of the following:
Intel Core-i7 machine.
Colour Monitor 24 inch.
Laser Printer
Mouse, Keyboard etc.
Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.
Running meters (RM) for the cable/conduit is approximate. The contractor shall measure the running meter (RM) and procurement order shall be placed accordingly. The quantities shall be confirmed before start of work to the engineer-in charge.
Indoor and Outdoor Cameras:
Supply, Installation, Testing & Commissioning of Pure IP CCTV-Indoor Dome Type Camera 1/2.8" or better progressive CMOS Sensor, Varifocal Lens of 3mm to 10mm, 1920 x 1080 resolution at 25 FPS, P-IRIS ,WDR, BLC, Day Night, minimum Illumination at 50 IRE - 0.1 Lux in color and 0.001 lux B/W, Triple Streaming or better, adjustable resolution and bit rate, H.264 and MJPEG, motiom detection, AGC with ONVIF support, POE base. With all accessories IP-55 weather proof Housing, brackets, tamper proof screws, clamps, wiring etc. complete as required and as per tender specification. (CE, FCC, UL Listed).
Supply, installation, testing and commissioning of Video Management Software (VMS) and video recording software for control/monitor of the actual no. of camera quantity. Software shall be open platform and shall support Mobile client licenses and WAN connectivity. Software shall support Network Attached storage with 30 days recording at 720p /30fps in motion mode .System shall be server/Client architect as per specification. System shall support RAID-5 configuration and shall be fully redundant by using less no. of external components. The software should have failover feature.
IP Camera License for Video Management software
Surveillance HDD Storage in NVR:- NVR storage as required and the storage capable of storing 30 days recording at 20 fps, minimum 1.3 MP resolution at 80% Motion, the storage should be easily scalable w/o obstructing the functionality of system or loosing the data. Full redundancy is required on NVR's and Storage,Note:-Bidders to provide complete calculation of the storage to show that total storage is able to provide 30 days recording at above parameters.
Supply, installation, testing & commissioning of client work station having Processor Intel ® i7 8th gen, with 16 GB RAM with 1 TB HDD .Operating system Windows® 10 Professional 64-bit. Dual or compatible pair of NICs, 1 Gbps. NVIDIA 2 GB dedicated Graphic Card .
Supply, installation, testing & commissioning of 55" Flat LED 4K Color Monitors.
Supply,installation, testing & commissioning of; 10/100/1000 POE L2 Ethernet Managed Switch 12 port with 2 Nos of Fibre Slot and as per specification complete as required.
Supply,installation, testing & commissioning of; '6U Network Rack (wall mounted).
Supply,installation, testing & commissioning of; 42 U Network Rack (Floor mounted).
Supply,installation, testing & commissioning of 3C X 1.5 sq. mm power supply cable.
Supply, installation, testing and commissioning of Optical fibre cable in existing PVC/MS Conduit .
Underground / Over ground Laying of 40 mm HDPE Pipe for OFC/ Power/ Data/ Coaxial cables
Supply, installation Testing and commissioning of compatible media converter for the interconnection of Layer two switches on optical Fiber cable backbone , complete with patch cord, LIU units as required for integration as per specification complete as required.
Supplying, installing and jointing of PVC/MS conduits on surface or concealed complete with PVC/MS junction boxes, cover plates, PVC bends, PVC saddles, base and other accessories all made in PVC/MS with screws as required to complete the job. Exposed conduiting shall be painted with red enamel paint for identification.
25 mm dia*
Misc. Items:
LIU's for splicing of fiber.
RJ-45 conectors
CAT 6 Patch Cord (3 MTR)
OFC Patch Cord (3MTR)
Splicing of fiber.
Connecting accessories for Switches, Media Converters, LIUs, cameras etc.
Supplying installation testing and commissioning of Grid interactive roof top solar photo voltaic power generation system including all the required accessories like Solar PV module, Grid Tie invertor, arrey junction box, cabling & wiring, earthing, surge protection device, FRLSame structure for mounting of solar panel. The cell shall be poly crystaline silicon cells of 6 inch each and module efficiency shall be more than 17%. Solar module shall have linear output warranty with degradation not exceeding 0.7% FRLSom 2nd Year onwards. Minimum 80% power output must be assured at end of 25 years. The FRLSont glass of solar module shall be low iron tempered glass ARC type. Termination box shall be Thermo-plastic, IP 67 or better, UV resistant with built-in-bypass. The nominal power of a single PV module shall be minimum 325 Wp or higher. Positive power tolerance modules only to be used. RF identification tag for each solar module shall be provided inside the module and must be able to withstand environmental conditions. The solar panel shall be complience of IEC 61215, IEC 61730 certified by TUV Rheinland / UL. The solar panel shall be installed as per BOQ & detailed technical specification.
MS perforated cable tray painted with powder coating 150 X 50 X 1.6 mm
MS perforated cable tray Connector 150 X 50 X 1.6 mm
MS perforated cable tray Bend 150 X 50 X 1.6 mm
Supply, Installation, testing & commissioning of 230V, 2.5 KVA Inverter complete with Over-load protection relay, battery charger, 12V, 180 AH Lead Acid battery, Moulded Plastic Cabinet/rack for Battery & Inverter including interconnection wiring with suitable size of PVC insulated Copper wire from battery to Inverter.
Add 18% GST
Add 1% Labour cess 1%
Manish Kumar Singh
Santosh Kumar Singh
M/s Himalaya Construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .