Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹58.4 LAccepted-AOC | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹69.8 L+₹9.5 L (15.8%)Rejected-Finance WARD NO 1 CALICUT PORT BLAIR SOUTH ANDAMAN 744105 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L2 | Rejected-Finance being highest | |
| 3 | L3₹73.5 L+₹13.2 L (21.9%)Rejected-Finance 183 MG ROAD JUNGLIGHAT PORT BLAIR 744103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN NICOBAR ISLANDS | 744103 | L3 | Rejected-Finance being highest |
Tender Value
₹73 L
EMD Value
₹1.3 L
Closing Date
9 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Arvind Bhakuni, CWE Port Blair
Commander Works Engineer Military Engineer Services Junlighat Post Minniebay Port Blair 744103
SEPCIAL REPAIRS TO BLDG NO T-1,T-1F,T-2,T-6,T-1FA,T-58,T-59 AND T-60 OF INS UTKROSH UNDER GE MINNIEBAY, PORT BLAIR
2024_MES_657660_1
81108 SEPCIAL REPAIRS TO BLDG NO T1T1FT2T6T1FAT58T59 AND T-60 OF INS UTKROSH UNDER GE M
Open Tender
Civil Works
Item Rate
270 days
Port Blair
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE Minniebay
₹1.3 L
Yes
18 Sept 2024
4 Jun 2024
16 Jul 2024
4 Jun 2024
9 Jul 2024
25 Jun 2024
Amount
Dismantling wrought iron or mild steel work of any description any position complete all as specified and directed by Enigneer-in-charge.
S&F Mild Steel Rolled sections as in Roof Trusees (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.
M&L for preparation of new or previously untreated steel surfaces of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
S&F in repairs pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed by Engineer-in-charge.
S&F in repairs pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed by Engineer-in-charge.
S&F aluminium flat as wind tie of any size fixed with 40/50mm aluminium self tapping screws with integral EPDM washer screwed in roof covering including all necessary drilling, bolting and riveting etc and similar work complete all as specified and directed by Engineer-in-charge.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc ) or insulation boards/slabs/blankets any thickness including cover fillets complete all as specified and directed.
S&F Aluminium anodised snap grid false ceiling of standard aluminium section such as wall angle of size 38mm x 25mm x 2.4mm weighing 0.36Kg/Rm, main/cross tees of size 36.5mmx25mmx1.4mm weighing 0.24Kg/Rm, grid size n. exc 610mmx610mm suspended with 4mm GI wire at interval n. exc. 600mm centre to centre for main and cross tees fixed to roof slab, roof truss fixed with suitable size MS hook and fastening bolts etc including 'Non-asbestos fibre cement building boards' 4mm thick oceanic sheet of size n. exc 610x610mm size fixed with clips to aluminium snap grid complete all as specified and directed.
S&F 605x605mm grid hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size of 60mm long complete all as specified and directed.
Demolition of precast Concrete work/ precast concrete block built in Cement Mortar including all quoins arches pillars etc complete all as specified and as directed.
M&L for Pre-cast cement concrete block masonry using PCC, type C-1 solid blocks, exceeding 10cm in width and setting in cement mortar 1:6, straight or curved on plan exceeding 6m mean radius complete all as specified and directed.
Taking down cement plaster on walls any description incl racking out joints hacking for key and scrubbing down with water etc. complete all as specified and directed by Engineer-in-charge.
M&L for rendering 10mm thick cement plaster in CM (1:6) on brick/block wall or concrete surfaces finished even & smooth without using extra cement plaster complete all as specified and directed.
M&L for rendering 15mm thick cement plaster on fair faces of concrete block masonry in two layers, base layer 10mm thick in CM (1:6) and top layer 5mm thick in CM (1:4) (with river sand) mixed with WPC as per manufacturer's instructions finished even & smooth without using extra cement plaster complete all as specified and directed by Engineer-in-charge. Note: The cost of necessary water proofing compound shall deemed to be included in the quoted rate.
M&L for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 Litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 Sqm over new surfaces, wall including preparation complete all as specifed and directed.
M&L for two coats of oil bound distemper over a coat of chalk whiting, on plastered surfaces, preparatory to distempering complete all as specified and directed.
M&L for applying one coat of acrylic emulsion weather coat premium quality antifungal exterior emulsion on old plastered surface of wall inculding preparation complete all as specified and directed by Engineer-in-charge.
M&L for complete removal of existing treatment on wall surfaces and applying two coats of oil bound distemper over a coat of chalk whiting, on plastered surfaces, preparatory to distempering complete all as specified and directed by Engineer-in-charge.
Taking down existing chowkhats exc 1.5 Sqm and n. exc. 4.00 Sqm each without taking off shutter from the frame complete all as specified and directed.
Taking down shutters of any description exc. 1.00 Sqm and n. exc. 2.00 Sqm each complete all as specified and directed.
S&F anodised aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F Anodised aluminium door shutters,aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips,ruber neoprene packing,handles 2 Nos in each door ,hinges ,anodised aluminium snap beading screws complete all as specified and directed.
S & F Anodised aluminium window and ventilator shutters, side hung type with or without sash bars, aluminium sections weighing 0.55 kg/m and thickness of section not less than 1.6 mm including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays, friction hinges 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1no.) complete all as specified and directed.
S&F for aluminium wire cloth, 0.45mm nominal dia of wire and average width of apeture 1.40mm and fixed with aluminium wire staples complete all as specified and directed.
S&F 5.5mm thick sheet glass ordinary quality in squares n. exc. 0.5 Sqm each pane complete all as specified and directed.
S&F ordinary quality sheet glass 4.00mm thick in square n. exc. 0.50 Sqm in each pane complete all as specified and directed.
M&L for 12mm thick prelaminated particle board, interior grade, prelaminted on both sides with decorative choice laminations, fixed with screws to aluminium frame work complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding(not backing), removing serviceable tiles to store and rubbished off the premises all as specified and directed.
Dismantling of stone slab of any description including cement mortar bedding but not backing complete all as specified and directed.
M&L for 25mm thick PCC (1:2:4) type B-0 (using 12.5mm graded stone aggregate) on floor as sub base or roof surface to bring uniform surfaces complete all as specified and directed.
M&L for 15mm thick screed bed or bedding layer in CM (1:6) for laying floor finishes complete all as specified and directed.
M&L for rendering 10mm thick in CM (1:4) on vertical surfaces as backing coat of wall ties etc, complete all as specified and directed.
M&L for vitrified double charged coloured ceramic tiles 10mm thick (Square/rectangular) area of each tiles n. exc 0.36Sqm in floors set and jointed in neat cement slurry and pointed in white/coloured cement to match complete all as specified and directed.
All as per Item No 33 here-in-above but on dado/skirting complete all as specified and directed.
M&L for non-skid ceramic coloured tiles 400x400mm and 8-10mm thick (square or rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors etc and jointed in neat cement slurry and pointed in white cement or coloured cement to match the shade of tiles complete all as specified and directed
All as per Item No 35 here-in-above but on vertical surfaces/skirting complete all as specified and directed.
S&F glazed ceramic coloured tiles in vertical surfaces 300x450x7 to 8-10mm thick set and jointed in neat cement slurry and pointed in white and coloured cement to match including cutting to reqd shape and size complete all as specified and directed.
M&L for Granite 20mm thick machine cut in skirting/ dado laid over cement screed and jointed in grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing complete all as specified and directed.
M&L for Granite 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing complete all as specified and directed.
M&L for cleaning the existing floor/ concrete surfaces/path by washing, rubbing etc to remove caked mud/ grease etc and applying high pressure wall jet of 120 PSI or move for obtaining a clean surfaces free from alge/organic particles and applying one coat of weather resistant floor paint complete all as specified and directed.
Demolition of cement concrete(unreinforced) of any description and in any position not otherwise specially provided for complete all as specified and directed.
M&L for 75mm thick cement concrete type D2, 1:4:8 (using 40mm graded stone aggregate) in sub base of flooring/hard standing, finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for coloured chequered cement concrete tiles 30cm x 30cm x 25mm thick, set and jointed neat cement slurry and pointed with coloured or grey cement match with pigment, over and including 15mm thick screed bed or bedding layer in CM (1:6) etc complete all as specified and directed.
M&L for vitrified ceramic tiles 10mm thick (square/rectangular) , polished, area of each tiles not exceeding 0.36Sqm, floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15mm thick in CM (1:6) complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks etc including cleaning or refixing or removal to Stores (measured overall as fixed along the centre line over fittings and accessories) PVC pipe of size 150mm, 110mm, 75mm from trenches and walls with all fittings incl necessary excavation, returning, filling and removal upto 250mtrs complete all as specified and directed.
M&L for 150mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches floor or wall and similar works complete all as specified and directed.
M&L for 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches floor or wall and similar works complete all as specified and directed.
M&L for 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches floor or wall and similar works complete all as specified and directed.
S&F 75mm dia PVC(SWR) bend with oval access door complete all as specified and directed.
S&F in repairs 75mm dia PVC (SWR) branch piece (Single Y) equal or unequal with oval access door complete all as specified and directed.
S&F 110mm PVC (SWR) bend with oval access door complete all as specified and directed
S&F in repair 110mm dia branch piece (single Y) equal or unequal with oval access door complete all as specified and directed.
Supply and laying in repairs CPVC pipes SDR11 and plain CPVC SDR 11 firrings on walls/ceiling or laying in floor with outer dia 20mm including taking down complete all as specified and directed.
Supply and laying in repairs CPVC pipes SDR11 and plain CPVC SDR 11 firrings on walls/ceiling or laying in floor with outer dia 25mm including taking down complete all as specified and directed.
Supply and laying in repairs CPVC pipes SDR11 and plain CPVC SDR 11 firrings on walls/ceiling or laying in floor with outer dia 32mm including taking down complete all as specified and directed.
S&F in repair 15mm bore GI water tubing, medium grade with all fittings and fixed to wall, floor and ceiling etc including taking down complete all as specified and directed.
S&F in repair 20mm bore GI water tubing, medium grade with all fittings and fixed to wall, floor and ceiling etc including taking down complete all as specified and directed.
S&F in repair 25mm bore GI water tubing, medium grade with all fittings and fixed to wall, floor and ceiling etc including taking down complete all as specified and directed.
M&L for Cutting chases in concrete block walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 for concealed water tubing etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
Fixing only in repairs Bib Cock/Stop Cock/Mixers including cleaning,removing of blockages etc of any type and size including replacement of brass spandle if required complete all as specified and directed. Note :- Brass spandle will be measured and paid seperately.
S&F in repairs vitreous china white heavy duty counter top wash hand basin of 520x440x180mm size including waste coupling and waste pipe complete all as specified and directed.
S&F in repairs 15mm bore fancy type CP centre hole wash basin mixture high quality without pop up waste with 450mm braided hoses complete all as specified and directed.
S&F in repairs, 15mm bore CP angular stop cock fancy type high quality with wall flange. Make : Jaquar Cat Part 5053N/ Johnson Cat Part No T1310C/ Somany Cat Part No 272210430041 as approved by GE
S&F in repairs, 15mm CP bib taps fancy type heavy duty with wall flange complete all as specified and directed.
S&F in repairs 15mm CP 2-way bib cock heavy duty complete all as specified and directed.
S&F in repairs CP health faucet high quality with 8mm dia flexible tube of length 1.2m and wall hook complete all as specified and directed.
S&F in repairs CP Towel rail fancy type high quality 600mm long complete all as specified and directed.
S&F in repairs CP Toilet paper holder fancy type high quality complete all as specified and directed.
S&F in repair Corner glass shelf high quality of 5mm thick glass ,12 cm wide & 60 cm long CP railing with bracket complete all as specified and directed.
S&F in repair high quality CP towel ring square wuth round flange fancy type complete all as specified and directed.
S&F in repairs sheet glass shelf consisting of 5.5mm thick sheet glass shelf assembly ,12 cm wide & 60 cm long CP railing with bracket complete all as specified and directed.
S&F in repair 15mm dia wall mixer cast copper alloy with capstan heads, chromium plated screwed down high, pressure with provision of overhead shower on upper side connecting legs and wall flanges high quality fancy type complete all as specified and directed.
S&F in repairs Vitreous China wash down water closet pan of size 'P' trap or 'S' Trap (pedestal pattern), with Plastic water closet seat, hinges, fixing accessories set, cistern fittings at overall size of 640x360x390 complete all as specified and directed
Supply and fix in repairs waste pipe of any dia complete all as specified and directed.
Supply only Brass spandles for bib cocks/stop cocks/wall/basin mixers etc complete all as specified and directed.
S&F in repairs sinks with drainage board made of stainless steel 1mm thick for kitchen with plug washers, waste pipe and coupling including bedding in cement mortar, two coar iron fixing bracket of required size and connecting union to pipe over all size 1040mmx510mm with bowl size 510mmx405mmx203mm complete all as specified and directed.
S&F in repairs Chromium plated waste coupling for sink/WHB complete all as specified and directed.
S&F in repairs vitreous china wash down water closet pan (pedestal pattern) coloured (including two Nos fixing bolts incl PVC seat cover but excluding flushing cistern and flush pipe complete inlcuding making good to floor with and including fixing P or S trap, complete all as specified and directed.
S&F in repairs PVC water closet seat cover white, closed pattern and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
Supply only PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
S&F in repair brass chromium plated overhead shower rose with arm 125mm size with long body with swivel joint including fixinfg to steel pipe or union complete all as specified and directed.
S&F in repair 10 litre capacity PVC low level valveless syphonic action type flushing cistern, white with intel, ball valve, float and handle including brackets and bends complete all as specified and directed.
M&L for repairs to existing PVC flushing cistern by replacing minor parts like flushing knob, float, screws, washers including connecting to existing water supply line and water closet pan complete all as specified and directed.
S&F in repairs 25mm dia alumimium powder coated best quality curtain rails with fixing brackets in both ends complete all as specified and directed.
S&F in repairs decorative globes for curtain rails to be fixed at both ends complete all as specified and directed.
S&F in repairs for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed.
Dismantling any type of boarding with wooden frame work as in kitchen cabinet,shutter, dawer and similar work including building hardware complete all as specified and directed.
M&L for 18mm thick MDF high quality boardings both side pre-laminated, one side (white) and other side coloured and pattern decorative lamintes as approved as in kitchen cabinet/shelves/ wardrobe/ wall panelling fixing with necessary small fitting as required as per manufacturer's instruction complete as specified and directed.
S&F stainless steel auto closing heavy duty modular hinges for cupboard shutters. Make :- Godrej or equivalent as approved by GE.
S&F 75mm long extruded brass handles, fabricated polished type complete all as specified and directed.
Dismantling posts and struts (wooden, steel or RCC ) any section including taking out embedded portion and making good disturbed ground concrete, brick work, masonry etc complete all as specified and directed.
Dismantling fencing wire mesh of any type complete all as specified and directed.
Excavating in post holes (or similar holes) each n. exc 0.5 Cu.m getting out, returning, filling in and ramming earth/broken rubble mixed with earth around, in layers n. exc 25cm, watering and removing surplus soil to a distance n. exc 50m and making good surface in soft/loose soil complete all as specified and directed.
M&L for PCC type D-2, 1:4:8 (using 40mm graded aggregate) as in foundations, fillings and mass concrete complete all as specified and directed.
S&F MS framed work such as fencing post including cutting tops to shape as directed, drilling holes, notching for wire etc flat iron fillets ( for securing wire mesh etc) including all necessary drilling bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
M&L for PVC coated GI chain link fencing 3.5mm dia with 50mmx50mm mesh including fixing of MS round bars, flat iron and machine made hexagonal or square head bolts to fencing posts complete all as specified and directed. Note :- MS Round bars and bolts will be measured and paid separately
Supply only MS screw bolts n exc 12mm dia machine made with hexagonal or square head at one end and screwed other or both ends screwed for fixing of chain link fencing complete all as specified and directed.
Supply only 10mm dia Round bars for support to chain link fencing conforming to Fe-290 (Gde E-165) complete all as specified and directed.
M&L for taking down carefully existing aluminium /copper point wiring, (light, fan socket or power) unscrewing from board/outlet boxes, fitting and fixtures such as switches, sockets, ceiling rose,lamp holder, tube/ceiling fittings, bulk head fittings, tube lights and regulators etc and making good disturbed surfaces on walls, floors , ceilings etc complete all as specified and directed.
M&L for taking down unserviceable submain wiring alongwith batten/PVC/steel conduits etc and making good disturbed surfaces of walls/ floors to match the existing surfaces complete all as specified and directed.
M&L for taking down unserviceable main switches, DBs, and making good disturbed surfaces of walls/ floors to match the existing surfaces complete all as specified and directed.
M&L for point wiring with two core single PVC insulated and unsheathed 1100 volts grade cable multistranded copper conductor of size 1.5 Sqmm nominal area (FRLSH) drawn through and including non-metallic rigid PVC Conduit, medium duty not less than 20mm dia concealed in wall/fixed on walls/ceiling with GI saddles, GI screws, rawl plugs with all fittings including tees, junction boxes including one green colour 1.5 Sqmm PVC insulated unsheathed multistranded copper conductor cable FRLSH grade as earth wire upto common earth and connected to earth dolly complete all as specified and directed. Note:- The quoted rate shall deemed to be include the cost of : 1. GI Metal flushboxes and modular cover plate with frame of any module complete. 2. Proper colour coding is to be followed as per IS specifications. 3. Wiring shall be concealed/ on surface with rigid PVC conduit medium grade/PVC casing caping as per site requirement. 4.Electric wiring test sheet before and after completion of wiring to be submitted before claiming the payment. 5.Cutting chases for conduit and sunking boxes, cutting and making holes in wall/floor passing in or through conduit making good of the disturbed surfaces matching with existing wall finish/colour complete.
One light point controlled by one way switch.
One bell/buzzer point controlled by one push button independent
One switch socket 3 pin 5 Amps flush type on independent board.
One switch socket 3 pin 5 Amps flush type on same board.
All as per Item No 102 here-in-before but with 2.5 Sqmm FRLSH cable for one socket 5 pin 15 Amps flush type/ Metal clad switch on independent board complete all as specified and directed.
M&L for submain wiring with two single core PVC insulated unsheathed multi-stranded copper conducter of Size 6.0 Sqmm (FRLSH) and one single core PVC unsheathed multistranded copper conductore cable green colour of size 6.0 Sqmm(FRLSH) as earth lead in and including concealed with concealed with PVC conduit medium grade of suitable size or surface wiring with PVC casing caping of suitable size and making good disturbed wall surfaces to match with existing specification including taking down unserviceable submain wiring complete all as specified and directed. Note : - (a) Three runs of single core cable with one run of PVC conduit/PVC casing and caping will be measured as one length. (b) Wiring shall be concealed/on surface with rigid PVC conduit medium grade/PVC casing caping as per site requirement. (c) Rates are deemed to be included for chases of conduit, cutting and making holes in wall/floor for passing in or through conduit making good disturbed surfaces with existing wall colour complete.
M&L for submain wiring with two single core PVC insulated unsheathed multi-stranded copper conducter of Size 4.0 Sqmm (FRLSH) and one single core PVC unsheathed multistranded copper conductore cable green colour of size 4.0 Sqmm(FRLSH) as earth lead in and including concealed with concealed with PVC conduit medium grade of suitable size or surface wiring with PVC casing caping of suitable size and making good disturbed wall surfaces to match with existing specification including taking down unserviceable submain wiring complete all as specified and directed. Note : - (a) Three runs of single core cable with one run of PVC conduit/PVC casing and caping will be measured as one length. (b) Wiring shall be concealed/on surface with rigid PVC conduit medium grade/PVC casing caping as per site requirement. (c) Rates are deemed to be included for chases of conduit, cutting and making holes in wall/floor for passing in or through conduit making good disturbed surfaces with existing wall colour complete.
M&L for submain wiring with two single core PVC insulated unsheathed multi-stranded copper conducter of Size 1.5 Sqmm (FRLSH) and one single core PVC unsheathed multistranded copper conductore cable green colour of size 1.5 Sqmm(FRLSH) as earth lead in and including concealed with concealed with PVC conduit medium grade of suitable size or surface wiring with PVC casing caping of suitable size and making good disturbed wall surfaces to match with existing specification including taking down unserviceable submain wiring complete all as specified and directed. Note : - (a) Three runs of single core cable with one run of PVC conduit/PVC casing and caping will be measured as one length. (b) Wiring shall be concealed/on surface with rigid PVC conduit medium grade/PVC casing caping as per site requirement. (c) Rates are deemed to be included for chases of conduit, cutting and making holes in wall/floor for passing in or through conduit making good disturbed surfaces with existing wall colour complete.
S&F modular switch one way, 6 Amps, 1 Module, 240 Volts complete all as specified and directed
S&F modular switch one way, 16 Amps, 1 Module, 240 Volts complete all as specified and directed
S&F modular bell push 6 A, 1 Module, 240 Volts complete all as specified and directed
S&F modular socket 2/3 pin, 6 Amps, 2 Module complete all as specified and directed
S&F modular socket 2/3 pin, 6/16 Amps, 2 Module complete all as specified and directed
S&F ceiling rose, 3 terminal polycarbonate isolated body complete all as specified and directed
S&F bell ding dong type 240 Volts complete all as specified and directed
S&F LED light fittings 20W, 2000lm, CDL , surge protection of 2Kv, 4 feet 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed
S&F LED light fittings 10W, 1000lm, CDL , surge protection of 2Kv, 2 feet 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed
S&F LED luminaire 600mmx600mm, 40Watt, 220V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders and LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor case of suitable size complete all as specified and directed
Notes for Item No 114 to 116 :- (i) Driver efficiency shall be more than 85% (Constant Current driver). (ii) Shall have Non-isolated type driver. (iii) THD shall beless than 20%. (iv) LED driver current shall be less than 60mA. (v) Efficiency of LED chip shall be more than 130lm/watt. (vi) Efficiency of LED chip shall be 100lm/watt. (vii) Surge Protection shall be 2.0 Kv & above as per IEC Standard. (viii) Working humidity shall be 95%RH. (ix) Life of the light fittings shall be 50000 Hrs at 70% lumes. (x) CRI shall be more than 80. (xi) Working temperature shall be -10°C to 50°C. (xii) Heat sink extruded aluminium (xiii) Junction temperature shall be 85°C. Contd.../-
Notes (Contd....):- (xiv) Body of fittings shall be extruded aluminium type. (xv) Impact code shall be min IK 03 or more. (xvi) Shall submit LM79 report from third party NABL Accredited laboratory( instead of Manufacturer's in-house Laboratory) (xvii) Shall submit LM80 report from LED manufacturer. (xviii) Low/high voltage, reverse polarity, overload and short circuit protection in-built fixture. (xix) Shall be of IP-20 rating. (xx) Test certificates shall be submitted before commencement of work/claiming for payment. (xxi) Shall submit warranty certificate for minimum 2 years from OEM.
Taking down ceiling fan and exhaust fan of any size, sealing cable end, dismantling blades and removing fan and blades to MES store complete all as specified and directed.
Supply & fixing ceiling fan 1200mm sweep with blades, suitable BLDC remote electronic regulator as per OEM design down rods and connected accessories, 230 V, 1200 mm sweep. Min air delivery 210 CMM, 5 star rated, equipped with brushless direct current motor (BLDC) including provision of cable from ceiling rose/connector to fan complete all as specified and as directed.
Fixing and hanging only ceiling fan/ exhaust fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed.
Supply & fixing exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 HZ, RPM 1200, Copper winding of sweep 250mm and exhaust fan shall be fixed with suitable size of buzzer bolt/hold fastner including making hole to the wall surface of any type/girth and at any height for fixing of exhaust fan including making good disturbed surface with existing wall colour and provision of cable from ceiling rose/connector to fan complete all as specified and as directed. Note :- Old unserviceable exhaust fan will be deposited to MES store yard.
M&L for taking down existing water cooler of any capacity carefully by disconnecting existing electrical connection, removing aside,servicing of water cooler by opening the machine on site removing the dust from body, cleaning condenser, cooling coil, fan/blower drum, water tank, oiling/greasing to fan motor, checking all the electrical connections necessary testing and commissioning at specified locations complete all as specified and directed.
M&L for taking down existing split unit AC unit 1.5/2 ton capacity carefully by disconnecting existing electrical connection, removing aside, servicing to ACs & refrigerator including taking down from the position, dismantling the sheet metal parts, blowing out the dust , carryout the chemical cleaning to choked cooling coil and condensor coil, by spraying dilated chemical cleaning agent till removal of complete choking, flushing across the coils, cleaning all the sheet metal parts, filter grill and fixing all the dismantled parts with sheet metal screw, lubricating the fan motor bush/bearing, checking all the electrical connections, renew any burned pitted lugs/clip and fixing back to position and testing and commissioning at specified location complete all as specified and directed. Note :- Gas Charging if required, shall be measured and paid seperately.
Supply and fixing of copper tubing of size 3/8" flare size conforming to relevant IS with foam insulation and wrapping tape including required copper brazing work complete all as specified and directed.
Supply and fixing of copper tubing of size 5/8" flare size conforming to relevant IS with foam insulation and wrapping tape including required copper brazing work complete all as specified and directed.
Supply only refrigerant gas R-32 in manufacturer's sealed cylinder complete all as specified and directed. Note:- (i) Empty cylinder shall be returned to the Contractor. (ii) Payment of the gas shall be made for net weight of gas
Supply and fixing as in repair of MCCB DB VTPN 8 way IP-54 made of sheet steel phos phatised, powder painted with 250 Amps copper bus bar for each phase, neutral link, earth bar and Din rail ,415 Volts with double door with Suitable for MCCB 4-Pole 100 Amps as incomer and MCB Single Pole outgoing complete all as specified and as directed.
S&F MCB DB TPN 4 way, IP-54, IK-09, double door sheet metal enclosure, 415V, 200Amps rated busbar including suitable size of copper ferrules for fixing of cable complete all as specified and directed
S&F MCB DB SPN 4 way, IP-54, IK-09, double door sheet metal enclosure, 240V, 100Amps rated busbar including suitable size of copper ferrules for fixing of cable complete all as specified and directed
S&F MCB DB SPN 8 way, IP-54, IK-09, double door sheet metal enclosure, 240V, 100Amps rated busbar including suitable size of copper ferrules for fixing of cable complete all as specified and directed
Notes for Item Nos 127 to 130 (i) MCCBs and MCBs will measured and paid separately. (ii) The cost for flushing of Distribution box in any type of wall and making good disturbed surfaces with existing colour shall be deemed to be included in the quoted rate.
S&F single pole and neutral enclosures with two pin and earth plug and socket with one single pole MCB 20 Amps 'C' curve, 10 kA complete all as specified and directed.
S&F MCCB 4 pole, thermal adjustable type, 100 Amps, 50 Hz, 415V with rupturing capacity 25 kA, lcs=100% lcu complete all as specified and as directed.
S&F MCB TPN 40-100 Amps, 10 kA, 'C' curve, 415 Volts, 50Hz complete all as specified and as directed.
S&F MCB TP 32-63 Amps, 10 kA, 'C' curve, 415 Volts, 50Hz complete all as specified and as directed.
S&F MCB SPN 40 Amps, 10 kA, 'C' curve, 230 Volts, 50Hz complete all as specified and as directed.
S&F MCB SPN 6-32 Amps, 10 kA, 'C' curve, 230 Volts, 50Hz complete all as specified and as directed.
S&F MCB SP 40 Amps, 10 kA, 'C' curve, 230 Volts, 50Hz complete all as specified and as directed.
Supply and fixing LED bldg security light fitting 25 watt not less than 2500lm, 230V AC, Cool white, outdoor type, pressure die cast housing with epoxy powder coated, dark graphite grey colour finish, poly carbonate cover with individual LED lenses with IP 65 protection including SPD 10KV complete all specified and as directed. Make:- Luker /Bajaj/Havells/Philips/Crompton
M&L for Fabricated mounting bracket for security light fitting made out of GI tubing 25mm dia light grade size 1.2m long, bend to shape including MS clamp/bracket made out of 25x3mm GI flat iron with necessary nut & bolts, washers complete all as specified and as directed.
Supply and laying in trenches, fixed on walls, passing through pipes, jointing and testing of electric LT cables 3.5 core 35 Sqmm, XLPE insulated, PVC sheathed, galvanised steel strip or wire armoured electric power cables with stranded aluminium conductors 1100 volts grade including taking down old unserviceable cable complete all as specified and directed. Note :- (i) The rates shall be inclusive of cable lugs at both ends of Cables. (ii) Joint kit if required shall be measured and paid separately.
Supply and laying in trenches, fixed on walls, passing through pipes, jointing and testing of electric LT cables 3.5 core 120 Sqmm, XLPE insulated, PVC sheathed, galvanised steel strip or wire armoured electric power cables with stranded aluminium conductors 1100 volts grade including taking down old unserviceable cable complete all as specified and directed. Note :- (i) The rates shall be inclusive of cable lugs at both ends of Cables. (ii) Joint kit if required shall be measured and paid separately.
Supply, install , testing and commissioning of CPRI approved LT panel factory made outdoor type, double door fabricated out of 3.15mm thick CRCA sheet, floor mounting, dust and vermin proof. The Panel shall be suitable for 415 V 3 phase 4 wire system, weather proof with IP-54 protection with separate hinge door for each compartment for incoming and outgoing switchgears/ACBs/MCCBs etc with locking arrangement, with back door openable (screwed), including painting with two coats of epoxy powder paint over a coat of primer after undergoing a rigorous metal treatment process involving alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with aluminium busbar (TPN), suitable double compression copper cable glands complete in all respect and including PCC foundation work and taking down unserviceable panel complete with comprising of following items :- (a) Aluminium Bus bar of rating 300 A mounted on porcelain insulator - 01 Set (Set of 4 Nos) with colour coded PVC sleeve insulation for TPN. (b) Incoming :-MCCB 4 Pole 200 Amps, 50Hz, 415V with minimum rupturing capacity 25 kA (Thermal magnetic release) lcs= 100% lcu and adjustable overload setting 80% to 100% and short circuit setting (5-10)- 01 No
Excavation in trenches any type of soil (soft/loose/hard/dense) n. exc. 1.5 mtr wide and n. exc 1.5m depth for foundation, pipe, laying of cable etc n. exc 10 Sqm on plan and n. exc. 1.5m depth and getting out complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and directed.
Removing excavated material (soil) to a distance not exceeding 50 meters and depositing where directed at a level not 1.5 metres above the starting point complete all as specified and directed.
Supply & Laying in repairs DWC (Double Wall Corrugated) HDPE pipe ISI marked of outer dia of 40 mm, polythylene confirming to IS 16205 part-24 including coupler & Bend with smooth internal and corrugated external surface for non pressue under ground cable complete all as specified and as directed by Engineer-in-Charge.
Supply & Laying in repairs DWC (Double Wall Corrugated) HDPE pipe ISI marked of outer dia of 63 mm, polythylene confirming to IS 16205 part-24 including coupler & Bend with smooth internal and corrugated external surface for non pressue under ground cable complete all as specified and as directed by Engineer-in-Charge.
Taking down old GI pipe of size 40-50mm dia complete all as specified and directed.
Supply & fixing GI pipe light grade 40mm dia with all fitting fixture with wall/road crossing etc complete all as specified and directed.
Taking down and relaying of serviceable power cable of XLPE/PVC insulated, PVC bedded, Galvanised steel strip or wire armoured underground heavy duty electric power cable with stranded aluminium conductor 1100 volts grade along with DWC pipe laid in trenches/duct with shadding/ on pole including all necessary fixing arrangement such as lugs and end termination etc of size 4 Core 16 Sqmm to 3.5 core 70 Sqmm complete all as specified and directed. Note :- Quoted rate shall deemed to be included for excavation and DWC pipe.
Taking down and relaying of serviceable power cable of XLPE/PVC insulated, PVC bedded, Galvanised steel strip or wire armoured underground heavy duty electric power cable with stranded aluminium conductor 1100 volts grade along with DWC pipe laid in trenches/duct with shadding/ on pole including all necessary fixing arrangement such as lugs and end termination etc of size 3.5 core 95 Sqmm to 3.5 core 240 Sqmm complete all as specified and directed. Note :- Quoted rate shall deemed to be included for excavation and DWC pipe.
S & F cable in repairs cable jointing kit for 1100Volt grade cable for straight through joint, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 4 Core 16 Sqmm to 3.5 Core 50 Sqmm as in repairs complete all as specified and as directed by Engineer-in -charge.
S & F cable in repairs cable jointing kit for 1100Volt grade cable for straight through joint, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 3.5 Core 70 ro 120 Sqmm as in repairs complete all as specified and as directed by Engineer-in -charge.
M&L for earthing complete with Galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised earth strip 32 x 6mm connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 40 mm dia GI pipe medium grade for protection of GI earth wire and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type C1 chamber, MS funnel, wire gauge, 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I. Note: (i) Cost of GI earth wire and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, PCC chamber pit, test point complete
SEVEN HILLS INDUSTRY
Hindustan Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .