Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.3 CrAccepted-AOC 858 SECTOR 23 127021 | BHIWANI | HARYANA | 127021 | ₹21.3 Cr | L1 | Accepted-AOC Awarded |
| 2 | L2₹23.8 CrRejected-AOC MITTAL FARM LOHARU ROAD CHARKHI DADRI 127306 | CHARKI DADRI | HARYANA | 127306 | ₹23.8 Cr | L2 | Rejected-AOC Refunded |
| 3 | L3₹28.5 CrRejected-AOC RGTPP KHEDAR HISAR HARYANA | HISAR | HARYANA | 125001 | ₹28.5 Cr | L3 | Rejected-AOC Refunded |
Tender Value
₹15.1 Cr
EMD Value
₹30.2 L
Closing Date
8 Jul 2020, 5:00 pmClosed
Executive Engineer
Executive Engineer,PH.Engg. Division No.3 Narnaul
AUGMENTATION OF WATER SUPPLY SCHEME CANAL BASED WATER WORKS AT BHALKI FOR 61 NO. VILLAGES TEHSIL ATELI MANDI, DISTRICT MOHINDERGARH. Construction of 3 MBS, 5 IBS and 38 Village
2020_HRY_122883_3
EIC Pkl No.23284 dt.25.02.2020
Open Tender
Civil Works
547 days
Narnaul Juriduction
Please refer Tender documents.
2 documents required · 2 mandatory
₹20,000
Executive Engineer
₹30.2 L
21 Sept 2020
18 Jun 2020
9 Jul 2020
18 Jun 2020
8 Jul 2020
18 Jun 2020
Amount
CLEAR WATER PUMPING MACHINERY Supply & Eraction of Horizontal spindle split casing type pumping sets of following duties directly coupled to AC squirrel cage induction type motor with accessories as described in Schedule No II complete in all respect with priming arrangement with complete base frame MBS 1 KATKAI 500 LPM X 25 M. Head
700 LPM X 30 M. Head
700 LPM X 40 M. Head
MBS 2 DHANUNDA 500 LPM X 25 M. Head
1500 LPM X 35 M. Head
MBS 3 KHOR 600 LPM X 30 M. Head
1300 LPM X 40 M. Head
4700 LPM X 60 M. Head
IBS - 1 Bhalkhi 600 LPM X 25 M. Head
600 LPM X 35 M. Head
IBS - 2 Kharani 500 LPM X 25 M. Head
600 LPM X 25 M. Head
IBS - 3 SAGARPUR 500 LPM X 30 M. Head
IBS - 4 KARYA 400 LPM X 25 M. Head
500 LPM X 25 M. Head
800 LPM X 45 M. Head
IBS - 5 MIRJAPUR 800 LPM X 35 M. Head
VBS (VILLAE BOOSTING STATIONS ) 400 LPM X 40 M. Head
500 LPM X 40 M. Head
600 LPM X 40 M. Head
700 LPM X 40 M. Head
800 LPM X 40 M. Head
900 LPM X 40 M. Head
PANEL BOARDS FOR MOTORS Supply, erection, testing & commissioning of wall mounted electrical L.T. Panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200 x 900 mm and 400 mm deep having follwing items For 2 no Pumping Sets of 500 LPM x 25 m Head a) Main switch 100 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 500 LPM x 25 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 1
For 2 no Pumping Sets of 700 LPM x 30 m Head a) Main switch 100 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 700 LPM x 30 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 2
For 2 no Pumping Sets of 700 LPM x 40 m Head a) Main switch 100 amp. 2 No. (L&T Siemens, ABB)b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T)c) Digital Multi function meter = 1 No.d) SPP = 1 No. of approved makee) Motor starter, Star delta for 700 LPM x 40 m Head = 2 Nos (L&T Siemens, ABB)f) VSS 1 No. & ASS 2 Nos. of approved make.g)Capacitor KVAR as per site requirement = 1 No.h) Indicating Lamp = One Seti) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no.3
For 2 no Pumping Sets of 500 LPM x 25 m Head a) Main switch 100 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 500 LPM x 25 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 4
For 3 no Pumping Sets of 1500LPM x 35 m Head a) Main switch 100 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 1500LPM x 35 m Head = 3 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 5
For 2 no Pumping Sets of 600 LPM x 30 m Head a) Main switch 100 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 600 LPM x 30 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 6
For 2 no Pumping Sets of 1300 LPM x 40 m Head a) Main switch 100 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 1300 LPM x 40 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 7
For 2 no Pumping Sets of 4700 LPM x 60 m Head a) Main switch 500 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 4700 LPM x 60 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 8
For 2 no Pumping Sets of 600 LPM x 25 m Head a) Main switch 100 amp. 2 No. (L&T Siemens, ABB)b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T)c) Digital Multi function meter = 1 No.d) SPP = 1 No. of approved makee) Motor starter, Star delta for 600 LPM x 25 m Head = 2 Nos (L&T Siemens, ABB)f) VSS 1 No. & ASS 2 Nos. of approved make.g)Capacitor KVAR as per site requirement = 1 No.h) Indicating Lamp = One Seti) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 9
For 2 no Pumping Sets of 600 LPM x 35 m Head a) Main switch 100 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 600 LPM x 35 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 10
For 2 no Pumping Sets of 500 LPM x 25 m Head a) Main switch 100 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 500 LPM x 25 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 11
For 2 no Pumping Sets of 600 LPM x 25 m Head a) Main switch 100 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 600 LPM x 25 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 12
For 2 no Pumping Sets of 500 LPM x 30 m Head a) Main switch 100 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 500 LPM x 30 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 13
For 2 no Pumping Sets of 400 LPM x 25 m Head a) Main switch100 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 400 LPM x 25 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 14
For 2 no Pumping Sets of 500 LPM x 25 m Head a) Main switch 100 amp. 2 No. (L&T Siemens, ABB)b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T)c) Digital Multi function meter = 1 No.d) SPP = 1 No. of approved makee) Motor starter, Star delta for 500 LPM x 25 m Head = 2 Nos (L&T Siemens, ABB)f) VSS 1 No. & ASS 2 Nos. of approved make.g)Capacitor KVAR as per site requirement = 1 No.h) Indicating Lamp = One Seti) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 15
For 2 no Pumping Sets of 800 LPM x 45 m Head a) Main switch 100 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 800 LPM x 45 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 16
For 2 no Pumping Sets of 800 LPM x 35 m Head a) Main switch 100 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 800 LPM x 35 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 17
For 2 no Pumping Sets of 400 LPM x 40 m Head a) Main switch100 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 400 LPM x 40 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 18
For 2 no Pumping Sets of 500 LPM x 40 m Head a) Main switch 100 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 500 LPM x 40 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 19
For 2 no Pumping Sets of 600 LPM x 40 m Head a) Main switch 100 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 600 LPM x 40 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 20
For 2 no Pumping Sets of 700 LPM x 40 m Head a) Main switch100 amp. 2 No. (L&T Siemens, ABB)b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T)c) Digital Multi function meter = 1 No.d) SPP = 1 No. of approved makee) Motor starter, Star delta for 700 LPM x 40 m Head = 2 Nos (L&T Siemens, ABB)f) VSS 1 No. & ASS 2 Nos. of approved make.g)Capacitor KVAR as per site requirement = 1 No.h) Indicating Lamp = One Seti) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 21
For 2 no Pumping Sets of 800 LPM x 40 m Head a) Main switch100 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 800 LPM x 40 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no.22
For 2 no Pumping Sets of 900 LPM x 40 m Head a) Main switch 100 amp. 2 No. (L&T Siemens, ABB) b) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta for 900 LPM x 40 m Head = 2 Nos (L&T Siemens, ABB) f) VSS 1 No. & ASS 2 Nos. of approved make. g)Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 23
Supply, erection, testing IS marked copper wire for various motors with underground system in PVC and flexible pipes copper wire 3 core complete in all respevts with accessories like thimble etc. i) 6mm2 3core
ii) 10mm2 3core
iii) 16mm2 3core
iv) 35mm2 3core
Sluice Valves / NRV & specials for Pumping Machinery Supplying, fixing, jointing, testing & commissioning of DI sluice valves resilient sheet P.N. 1.6 as per DNIT specification on the pumping machinery & head works including cost of jointing material (IVC / VAG make/ Kirloskar/ DVD) (MBS-32, IBS-36, VBS-180) 100 mm i/d
Supplying, fixing of DI swing check type reflux (non returned valve) PN 1.6 of IVC/VAG / Kirloskar/ DVD) (MBS-32, IBS-36, VBS-180) 100 mm i/d
Supply & Fixing of Mechanical Joints PN 1.6 alongwith ruber gaskit & galvanized nuts / bolts complete in all respect. (MBS-32, IBS-36, VBS-180) a) 100 mm i/d
a) 150 mm i/d
c) 250 mm i/d
d) 300 mm i/d
CI D/F Pipes. 100 mm i/d
Sluice Valves/ Specials For Rising Mains Supplying, fixing, jointing, testing & commissioning of DI sluice valves resilient sheet P.N. 1.6 as per DNIT specification on the pumping machinery & head works including cost of jointing material (IVC / VAG / Kirloskar/ DVD) For Rising main lines 150 mm i/d
Supply & Fixing of Mechanical Joints PN 1.6 alongwith ruber gaskit & galvanized nuts / bolts complete in all respect. 150 mm i/d
Providing & fixing of D.I. Kinetic Air Valve soft seated as confirming to I.S.I. complete in all respect. 80mm
Supply erection, testing of light fitting including wire in the pump chamber with material upto 10 points including switch, button, plug, PVC conduict pipe & copper wire etc. as per approved specifications. (for VBS)
Supply erection testing and commissioning of exhaust fans each having a capacity of 45 cubic meters per minutes, complete in all resct ( 9 at MBS-1 to 3 +15 at IBS-1 to 5 + 38 at Various VBS = 62 )
Supply erection & testing of Ceiling fan of size 48" i/d (1200 mm) of reputed ISI make complete in all respect for various Pump Chambers ( 6 at MBS-1 to 3 + 10 at IBS-1 to 5 + 38 at Various VBS = 54 )
Providing and fixing of insulated Rubber matting suitable for HKV installation 1 meter x 2 meter x 12 mm as per specification. (MBS-08, IBS-10, VBS-45)
Supply erection, and commissioning electric operated dewatering pump of 3 HP Kirlosker make complete from priming with wiring starters switches etc. also the required GI pipe (B Class) valves and sight glass etc. complete. ( 3 at MBS-1 to 3 + 9 at IBS-1 to 9 = 12 no.)
Supplying and fixing of Gantry with chain pulley block of following capacity with traveling trolley of appropriate lifting capacity for handling of pumping sets capable of moving along the girders to be provided in the pump house complete in all respects as per specifications approved by Engineer-in-Charge. 3 Ton Capacity at MBS -1 to 3
2 Ton Capacity at IBS 1 to 5
Supply erection testing and commissioning of Flow Meter (KRONE Make) with digital display of 150 mm i/d complete in all respect. (MBS-08, IBS-10, VBS-45)
Operation and maintenance for 6 Years. Operation and maintenance for the complete scope of work mention in the DNIT (Disinfection material supplied by the PHED) as per schedule-IV for a period of 5 year after 12 months during defect liability period 3 months trial run (will be charged to the A/Mtc. estimate). Operation and maintenance during defect liability period (operation only) after 3 month trial run period.
i)Operation and maintenance during 1st Year after defect liability period.
ii) Operation and maintenance during 2nd Year
iii) Operation and maintenance during 3rd Year
iv) Operation and maintenance during 4th Year
v) Operation and maintenance during 5th Year
Bidder Name
Amount
M/S SHREE BALAJI BUILDERS
NAFE SINGH CONTRACTOR
ANAND KUMAR CONT
ANAND KUMAR CONT
NAFE SINGH CONTRACTOR
M/S SHREE BALAJI BUILDERS
NAFE SINGH CONTRACTOR