| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.1 LAccepted-AOC | L1 | Accepted-AOC OK | |
| 2 | L2₹5.5 L+₹38,020 (7.43%)Rejected-Finance 99 MODEL TOWN PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹6.8 L+₹1.6 L (31.9%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹7.4 L+₹2.3 L (45.0%)Rejected-Finance 1ST FLOOR GURJEET MARKET DHANGU ROAD | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹8.2 L+₹3.1 L (61.0%)Rejected-Finance | L5 | Rejected-Finance Not being L1 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
3 Jun 2020, 6:00 pmClosed
CWE Pathankot
HQ CWE Pathankot
REPAIR / MAINT OF CENTRALISED AC PLANT FOR MSL STORAGE SHEDS AT UNCHIBASSI UNDER GE(SOUTH) PATHANKOT
2020_MES_333526_1
CWE/P-69/19-20
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Unchibassi
Class E Category c i
9 documents required · 9 mandatory
₹500
Yes
GE(South) Pathankot
₹20,000
Yes
22 Jun 2020
12 Mar 2020
5 Jun 2020
12 Mar 2020
3 Jun 2020
26 Mar 2020
Amount
M & L for detaching the compressor of central AC plant , Make ACCEL SABROC model SMC 6/100 of capacity 50 ton from foundation and strip opening of compressor including cylinder head and rear cover for top over hauling and taking out sleeves, piston assy , valve plate assy , suction and discharge reeds , shaft seal assy, connecting rods, oil pump, oil filter for cleaning, oiling, greasing etc as required and Re-assembling the same complete after over hauling by supply and fixing packing gasket, big end bearing, main bearing bush, CR bush, thrust washer, gudgen pin, o ring and other minor spares as required and pressure testing the complete plants for any leakage of gas/oil , plugging the leakage and & charging to refrigerant gas R-22 and compressor oil N-68, up to adequate level and pressure. including testing , complete and all as specified. (Note : Spare parts, refrigerant R-22 and Compresser oil N-68 (Non freezing) for replacement shall be measured and paid separately as supply only) as below:-
Supply only piston complete with pin and ring set, gudgeon pin and circlip lock complete all as specified and directed.
Supply only small end bearing of connecting rod complete all as specified and directed.
Supply only big end bearing and connected rod complete all as specified and directed.
Supply only main bearing (front and rear) complete all as specified and directed.
Supply only suction and discharge reads including tension springs complete all as specified and directed.
Supply only Neoprene O ring complete all as specified and directed.
Supply only gear wheel set complete all as specified and directed.
Supply only compressor gasket set complete all as specified and directed.
Supply only cylinder liner with suction valve complete all as specified and directed.
Supply only discharge valve read assembly all as specified and directed
M&L Dismantling of AHU and repair the leakage of cooling coil tray, removing of up to 50 TR chilled water cooling coil de-scaling of copper tubes cleaning washing of tubes and all as required and repair of rotating drum sand welding if required and replacing the worn out bracket bearing N 207/206 as required at site or directed by Engr-in-Charge.
S & F in replcement of angle valves (Brass) size 1/4 inch. Make : Pim / Sew / Brassomatic and all as specified and directed by Engr-in-Charge.
S & F in replcement of capacity control 3 way solenoid valve suitable for Model SMC 6/100 ACCEL SABROC compressor. And all as specified and directed by Engr-in-Charge.
S & F Oil pressure safety switch suitable for 50 TR AC plant Make : Indfoss / Denfoss and all as specified and directed by Engr-in-Charge.
S&F in replacement of CI body butterfly valve disc regulating type 100mm dia. Make : CASTLE/ ADVICE complete all as specified and directed.
S&F in replacement of oil pump assembly of compressor of make Accel-Sabroc Model SMC6/100 complete all as specified and directed.
S&F pressure testing of refrigerant circuit with dry nitrogen and testing for leakages and vacuum complete all as specified and directed.
Opening of condenser (50 TR capacities) and end covers de-scaling of condenser copper tubes with acid and cleaning tubes of scale with brushing etc as required for 50 TR capacity all accessories required at site complete all as specified and directed by Engr-in-Charge.
S&F in replacement of pressure gauge for water 0-10 Kg/Cmsq including necessary fitting complete all as specified and directed. Make : Gluck/Fibig/Ramco
M&L in replacement of non freezing compressor oil complete all as specified and directed.Make Servo/HPCL/BPCL
M&L for charging R-22 gas of make Mafron or equivalent as approved complete all as specified and directed. by GE/Engr-in-Charge.
S&F in replacement of heavy duty V belts of No B-72 or as required at site complete all as specified and directed. Make : Fenner/Alaska
S&F in replacement of heavy duty V fan belts of No C-96 or as required at site complete all as specified and directed.Make : Fenner/Alaska
S&F in replacement of high/low pressure cut out switch MP-15 complete all as specified and directed. make Indofoss/Denfoss.
S&F in replacement of thermostatic expansion valve for Central AC plant of Make ACCEL SABROC model SMC 6/100 of capacity as per sample complete all as specified and directed. by Engr-in-Charge.
S&F water flow switch suitable for for Central AC plant of Make ACCEL SABROC model SMC 6/100 as per sample complete all as specified and directed. by Engr-in-Charge. 50 TR AC plant make : Indfoss/Denfoss
Supply and fixing in replacement of cooling tower fins suitable for cooling tower of capacity of 150 Ton AC Plant including removing cleaning spreading brushing inside of the tower and fixing with new cooling fins complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement of MCCB 4 Pole 415 Volts 3 phase 630 Amps 36 KA, thermal magnetic release S1 -01 No (incoming) complete all as specified and directed. Make : L&T/ Legrand /Siemens
All as per item No 29 here-in-before but for MCCB 3 Pole 415 Volts 3 phase 125 Amps 25 KA thermal magnetic release complete all as specified and directed.
All as per item No 29 here-in-before but for MCCB 4 Pole 415 Volts 3 phase 100 Amps 25 KA complete all as specified and directed.
Supply & fix in replacement of contactor ML 6, 110 Amps, 3 phase, 50 Hz with 2 NO + 2 NC as per sample complete all as specified and directed by Engr-in-Charge.
All as per item No 32 here-in-before but for contactor ML 2, 32 Amps, 3 phase, 50 Hz with 2 NO + 2 NC complete all as specified and directed.
All as per item No 32 here-in-before but for contactor ML 1.5, 25 Amps complete all as specified and directed.
M&L in replacement of MCB TP 32 amps, with rupturing capacity 10 KA using thimbles of required size complete all as specified and directed. Make : Legrand/Havells/L&T
All as per item No 35 here-in-before but for MCB TP 40 amps complete all as specified and directed.
All as per item No 35 here-in-before but for MCB FP 63 amps complete all as specified and directed.
S&F in replacement of star delta timer electronic type 230/240 Volt as per sample complete all as specified and directed by Engr-in-Charge.
S&F in replacement of over load relay with single phase protection 14-23 Amps as per sample complete all as specified and directed. by Engr-in-Charge.
All as per item No 39 here-in-before but for over load relay 4.5-7.5 Amps complete all as specified and directed.
All as per item No 39 here-in-before but for over load relay 66-110 Amps complete all as specified and directed.
M & L for LT underground Cable XLPE insulated, heavy duty armoured sheathed 1100 volts grade 35 Sq mm, 3.5 core, with aluminium conductor, ISI marked as per IS : 7098(Part-1) complete all as specified and directed.
M&L Excavation in trenches not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide in any type of soil for laying and taking out of GI/CI pipes all as specified and directed by Engr-in-Charge
M&L Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25m thick complete all as specified and directed.
M&L Removing excavated material from site to a distance not exc 50mtr away and depositing where directed not exc 1.5mtr from the starting point complete all as specified and directed.
M & L Dry sand cushioning to UG cable 8 cm thick before laying and 15cm thick after laying complete all as specified and directed. Note:- 1.Dry fine sand of best available quality shall be used. 2.Punned thickness shall be made and paid.
M & L Sub class 'B' bricks well burnt perpendicular to the axis for the cable in trenches for protection to cable complete all as specified and directed.
Supply and fixing of copper tube of required size connect from Pressure/Oil guage to compressor of central AC plant ,Make ACCEL SABROC model SMC 6/100 of capacity 50 ton testing and commessioning complete all as specified and directed by Engr - in - Charge
M&L Cleaning of cooling Tower with MEC/MAC solution, rubbing and cleaning with nylon brush and removing dirt from coil fan complete all as specified and directed by Engr-in-Charge.
S&F Disconnecting electrically, dismentling and rewinding of cooling tower motor with all unsv parts of 3 phase 415 volts any type, make and capacity 5 to 7.5 HP cutting and removing existing burnt/short circuited winding wire complete, cleaning of core grooves and surfaces, re-winding the motor with superior quality enamelled copper winding wire duly ISI marked of suitable gauge for same Nos of coils and turns including insulation material such as sleeves, lathorised fiber glass, cotton/PVC tape, varnish etc reassembling the motor complete and refixing at site and making connection electrically all as specified and directed
All as per item No 50 here-in-before but of capacity 10 HP complete all as specified and directed.
All as per item No 50 here-in-before but of capacity 60 HP complete all as specified and directed.
S & F in Replacement of Oil filter and stainer assembly suitable for capacity 110 TR, compressor model SMC 6 / 100 complete all as specified and directed.
S & F In replacement of Discharge valve ring for suitable cap SMC 6/100 Make : ACCEL SABROC compressor all as specified and directed by Engr-in-Charge.
S & F In replacement of suction pipe for oil pump suitable cap SMC 6/100 Make : ACCEL SABROC compressor complete all as specified and directed by Engr-in-Charge.
S & F In replacement of suction carbon ring suitable for cap SMC 6/100 Make : ACCEL SABROC compressor complete all as specified and directed. by Engr-in-Charge.
Notes : The Schedule of Credit amount shall be deducted from the total of this schedule(BoQ) to arrive at Contract Sum.
satpal and brothers
M/S J N TRADERS
Vijay Kumar Contractor and Engineers
KULBHUSHAN AGGARWAL
shivrefrigeration
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .