Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.8 LAccepted-AOC | L1 | Accepted-AOC 1st lowest | |
| 2 | L2₹20.0 L+₹18,347 (0.93%)Rejected-Finance METHOPARA GANGANAGAR KOLKATA 700132 | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700132 | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹20.0 L+₹16,097 (0.81%)Rejected-Finance GR 8 ADDA BUILDING 1ST FLOOR CITY CENTRE DURGAPUR 16 | DURGAPUR | PASCHIM BARDHAMAN | WEST BENGAL | L3 | Rejected-Finance 3rd lowest | |
| 4 | L4₹20.0 L+₹20,647 (1.04%)Rejected-Finance | L4 | Rejected-Finance 4th lowest |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
5 Oct 2021, 12:30 pmClosed
EE/BED/PWDTE
PWD Compound, Kenduadihi, Near Bhairabsthan,Bankura-722102
HT Cable and allied Electrical works incl. Lightning Arrester work at BSMCandH, Bankura for Liquid Oxygen Plant for strenghtening COVID19 patient care at BSMCandH
2021_WBPWD_344792_1
WBPWDTE/EE/BED/NIQ_62/Q of 2021-22-3rd Call Tende
Open Tender
ELECTRICAL WORKS ORG
Item Wise
30 days
BANKURA
Please refer Tender documents.
3 documents required · 3 mandatory
₹40,000
28 Oct 2021
21 Sept 2021
7 Oct 2021
21 Sept 2021
5 Oct 2021
21 Sept 2021
Amount
Constructing Inspection Providing massonery chamber /box type 250 mm thick 1st class brick work (1:4) in all sides over a layer of jhama brick soling and 150 mm thick cement concrete with stone chips (1:3:6) including necessary earth work, fitting and fixing approved type S.W. master trap, constructing masonry invert with cement concrete (1:1.5:3) with stone chips, plastering inside and outside (outside upto 300mm below G.L.) with 20 mm thick cement plastering (1:4) and neat cement punning,including with R.C.C. slab of 100 mm thick with cement concrete (1:1.5:3) withstone chips including necessary reinforcement (upto 1%) and shuttering and necessary corbelling brick work (1:4) with suitable size appx 1200 mm X 1200 mm (inside) chamber and appx 1200 mm depth (below the Ground level ) as per requirement at the condition of site & to complete the same direction of EIC as because HT cable also run in future nearer to the of approved make With Pakur variety at the time of construction the Inspection chamber with the arrangement of fixing the above Hume/GI pipe on both side wall of the chamber for easy laying of various cables in future from Sub Station to Hospital and fill up the chamber with loose sand as per direction of EIC
Supply & Fixing and placing special type RCC concreate slab of size 1800 mm x 1800 mm x 100 mm thick made with 8 mm dia TMT Rod with sand ,cement & stone chips motter by casting arrangement incl necessary matching & lifting arrangement as per direction of E.I.C
Supply & Laying of following sizes Hume pipe PWD appvd make with appx 25 mm thk reinforced cement concrete pipe NP3/NP2 with with coller etc spigot socket for culverts on first class bedding of granular material in single row including fixing with cement mortar 1:2 to comp the job 300 mm (12" ) dia from HT Gear Room of WBSEDCL to HT Gear Room of PMSSY-III via existing HT inspection chamber as per requirement & direction of EIC
300 mm (12" ) dia from inspection chamber to the inspection chamber incl. cross the road for future provision as per requirement & direction of EIC
250 mm (10" ) dia from inspection chamber to the inspection chamber incl. cross the road for future provision as per requirement & direction of EIC
Charges for metal road cutting incl. refilling and mending the dameges as per direction of E.I.C.
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required 150 mm dia
50 mm dia
Supply & Fabrication and placeing special type MS cheeaker plate made of 6 mm thick incl 30 mm x 30 mm x 6 mm MS angle iron structure welded at 4 sides in cable trench top with 2 nos 3/8" TMT handle rod incl gas cutting, grinding & drilling with one coat of red laid primer and one coats of synthetic enamel paint as per direction of EIC.
Supply & laying 11 KV grade 3 core 240 sq.mm. XLPE(E) HT armoured cable laying as follows..as per direction of EIC on Masonary trench.
Through prelaid GI pipe.
Supply & Fixing of Heat Shrinkbale Indoor Type Cable End jointing kits suitable for 11KV(E), 3C X 240 Sq mm XLPE ( E) HT cable incl S & F jointing Kits , with epoxy / polyurethane resin based kits, tapes, push on kits, multiconductor construciton etc. (make Raycham RPG/ PWD appvd ) by expert HT cable jointer with Co's own tools & tackles as per direction of EIC
Supply & Fixing of suitable angle/flat iron bracket for holding the HT jointing unit with all necy. Materials at the HT Gear end. as per direction of EIC
Excavation of soil for installation of Earth Electrode and filling & ramming as to GS. For morrum soil
Earthing with 80 mm dia GI pipe (TATA-Medium)x 3.0 Mts.long and 1 No. 65 mm x 8 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 80 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts (for WBSEDCL HT Gear - 2 nos, Existing Sub Station- Tr-1- 4 nos, Existing Sub Station- Tr-2- 4 nos, LT Room-2 nos ).
Extra for treatment of soil by using salt & charcoal or coke for pipe electrode neutral earth.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe as to GS.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 65 mm x 8 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as requiredr as to GS.
Connecting the equipment body to earth bus-bar incl.S & F galvanized (Hot-Dip) MS flat 50 x 6 mm on wall/floor with GI saddle incl. nuts, bolts, washers & spacing insulator as to GS.
S & F 9 Ltrs. Capacity round botton fire bucket (make Fire shield) with iron hook incl. filling sand.
Supply & Delivery of Rubber mats upto 11KV grade (CLASS-C), 1.0 Mtr x 2.0 Mtr x 2.5 mm thickness and confirm IS:15652:2006.as per direction of EIC
Supply & Delivery of 11 KV grade rubber hand gloves.
Supply & Fixing of shock treatment chart.
Supply & Fixing of best quality First Aid Box on wall as to GS.
Supply & Fixing of Danger Board for High voltage, 11KV/415V (250 mm x 200 mm.) as per IS both in English & Bengali
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Make-Legrand/ Siemens/ LT/ Havells as to GS. 8 way Enclosure
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Make-Legrand/ Siemens/ LT/ Havells as to GS 2+ 8 way Enclosure
Supplying and fixing 240/415 V Isolator on din rail of existing DBs and necessary connection Make-Legrand/ Siemens/ LT/ Havells as to GS. 415 V, 63A FP
Supplying and fixing 240/415V, MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Make-Legrand/ Siemens/ LT/ Havells as to GS. 6A - 32A SP MCB
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single corestranded 'FRLS' PVC insulated & unsheathed copper wire ( Finolex / Havells/ KEI / Gloster /approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make),and drop Concealed type if reqd as per direction of EIC with 1x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire for ECC, to light/ fan/ call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish Average run 10 mtr
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire ( Finolex / Havells/ KEI / Gloster /approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box andmending good the damages to original finish On Board
Supply & Fixing 240 V, 2 x 6A, plug socket with separate 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 200 x 150 x 65 mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 240 V, 2 nos. 6A, & 2 nos. 20A plug socket with separate 2 nos. 6 A & 2 nos. 20A Piano key type switch, indicator & 16A kit-kat flush type fuse (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240 x 20 0x 65mm MS (16SWG) switch board and bakelite / perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Distribution wiring in 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Finolex / Havells/ KEI / Gloster /approved by EIC) in suitable size ( 20 mm ) PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 2 x 1.5 sqmm + 1 x 1.5sqmm (for Separate Plug)
2 x 2.5 sqmm + 1 x 1.5sqmm (for Power plug)
2 x 4 sqmm + 1 x 2.5sqmm (for Security Light )
2 x 6 sqmm + 1 x 4 sqmm ( from TPN MCB DB to SPN MCB DB s )
Supplying of following sizes Al. armoured PVC/XLPE (Havells/ Glostar/ KEI/ approved ) as per direction of EIC 4 core 35sqmm ( from VTPN to MCBPBDB )
Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core
Laying of 3.5 /4 core 35 sqmm Al. armoured PVC/XLPE cable surface on wall / on wall by clamp / concealed as reqd. as per direction of EIC
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 4 core 35 sq mm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials 4 core 35 sq mm
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as per G S 1.5 sq mm
Supply of 250 V 50 HZ high flo oscillating type metal body Wall Bracket( Tornedo - 2 ) fan operated by pull cord switch with inbuilt regulator ( Make -CG/Orient/Approved) 18" (450 mm)
Fixing of high flo oscillating type metal body Wall Bracket on wall with necessaryS&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length etc to complete the installation and mending good the damages as per direction of EIC
Supplying & Fixing angular holder (Anchor) on 3" wooden double round block incl. S&F 9 Watt LED lamp Philips make.as per direction of EIC
Supplying & Fixing 4 feet single commercial LED type fluorescent light fittings complete with all accessories with 1 x 20 Wt.Master LED Tube lamp similar to Havelles make cat No. REGALBATTENT8 1x22WSSBSWH (With 5 years warranty)corresponding to Wipro / Bajaj / Crompton suspended bellow the false ceiling with necy fixing arrangement by spl. tppe clamp etc and if the fittings fixing on wall then necy fixing arrangement by spl. tppe clamp on wall are necessary to complete the same with supports & MS clamp etc incl painting and mending good the damages to original finish as per direction of EIC
Supply & Fixing exhaust fan (Make -- EPC, Heavy duty) of following sizes after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of dia incl. Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) as per GS 12" (30 cm) 1420 RPM
Supplying and fixing of 250 V AC timers fixed on wall with flat iron frame as per direction of EIC and the Box shuld be comprising with the following accessorise --- i) Double-door SPN MCB Distribution Board with IP-42/43 protection 10 / 12 way Enclosureas reqd . ( Make - Legrand / L & T ) – 1 no ii) 230 V , 50 Hz ,16 Amp Single dial 1 x 24 Hrs.Timer ( Microrex QT31 ) of quartz driven running reserve Day dial back up by nickle cadmium battery (Make - GEC / Legrand ) – 1 no iii) 250 V, 50 Hz , 40 Amp DP Conctractor with ( 2 NO or 1 NO + 1 NC Aux. Contract ) ( Make - Legrand / L & T ) – 1 no iv) 250 V, 50 HZ , 40 Amp , DP MCB Isolator ( Make - Legrand / L & T ) – 1 no v) Auto / Manual By pass Toggle Switch arrangement – 1 no. vi) 250 V , Diode type neon Indicator lamp ( Make - Legrand / L & T ) – 1 no vii) Bakelite base with FP bolt type stud / Terminal block incl S & F Neutral Bar etc with this box for termination of power . viii) The complete arrangement must be wiring by 2.5 Sq mm PVC insulated Cu wire with suitable length incl socketing /lugs etc as per requirement & direction of EIC (Make - Legrand /L & T / Crabtree ) ( controlling the Exhaust Fan)
Connecting the equipments to earth busbar including S & F No. 10 SWG GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages as to GS.( for PBDB earthing )
Supply & Fixing of 74 W LED outdoor street light fitting ( Philips make cat No. BRP 409 LED 074 CW HE MR FG SI PSU GR ) compl. with all accessories to be fixed / Projected from the wall of the building incl. making holes to the building .S & F 40 mm dia / suitable size GI pipe 1.5 m average length (ISI-M)Arm Bracket with GI socket at one end & thread at other end with suitable bend to house fitting and making necy. connections with S& F necy. length of Copper coductor and mending goods to wall incl. painting as per direction of E.I.C.
Supplying & Fixing of PVC water proof type Loop box (Make-Sintex) of size 8"X10" comprising of 4 way 100 Amp. Capacity brass stud/terminal make- AC /DC.,having hinged PVC top cover & 4 mm thick with rubber gasket lining,railway type mechanical locking arrangement,comprising of one 250V,15A kit-kat fuse unit,one NL on porcelain insulator etc. conceal in wall as per direction of EIC
Inter connection between Loop Box to fittings by 1.1 KV 3 x 2.5 sqmm single core stranded 'FRLS' PVC insulated & unsheathed copper wire (make-Finolex/Havells/KEI) through 20mm size PVC pipe incl. necy. fittings as required as per direction of EIC
Supply & Fixing Lightning conductor Air-terminals made of 15 mm dia1500 mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar (4:2:1)
Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection as below and mending good damages to the building works: Length upto 0.5 Mtr
Length above 0.5 Mtr
Making soldered joints between conductors, conductors and air terminals for 4 SWG GI (Hot Dip) wire incl. supply of jointing materials and painting with 2 (two) coats of bituminous paint
Making soldered joints between conductors and down pipes/ other metallic objects for 14 SWG GI (Hot Dip) wire including supply of necessary 4 SWG GI (Hot Dip) wire, jointing materials and painting with 2 (two) coats of bituminous paint
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run
Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet/Roof/ Wall with GI Saddles 1100 mm apart incl. mending good the damages to building works
Supply & fixing of GI (Hot Dip) strips 20 mm x 3 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000 mm apart incl. mending good damages to building work
Supply & Fixing of Testing Joints by 20 mm x 3 mm thick GI (Hot Dip) strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S & F thimbles, GI bolts, nuts, check-nuts, spring washers etc. as required
Excavation of soil for installation of Earth Electrode and filling & ramming as to GS. For morrum soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long),13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed (For Morrum Soil ISI-Medium GI pipe as toGS.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required as to GS.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe as to GS.
Arrange the tempurary Electrical Power for the HT related work from HT Gear Room of WBSEDCL to HT Gear Room of PMSSY-III building by running the DG set and to complete the work with the help of DG and Cost of fuel (HSD) to be reimbursed as per the prevaling market rate as per direction of EIC
Top Up / Pouring of Diesel oil for the DG sets, as per requirement time to time including transportation charges from nearest petrol pump to Hospital & direction of EIC
DURGAPUR POWER
R K ENTERPRISE
TARUN KUMAR BARUA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .