Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 bidder. Amount shows after consider of Sch of Credit amount. | |
| 2 | L2₹19.1 L+₹1.9 L (10.9%)Rejected-AOC HOUSE NO 22 BHAGADUTTAPUR BELTOLA RUKMINIGAON ROAD GUWAHATI 781028 | KAMRUP METRO | ASSAM | 781028 | L2 | Rejected-AOC Rejected being higher than L1 bidder. | |
| 3 | L3₹19.6 L+₹2.4 L (14.2%)Rejected-AOC AZARA BHARALIPARA NEAR AZARA PUBLIC HALL GUWAHATI 781017 ASSAM | KAMRUP METRO | ASSAM | 781017 | L3 | Rejected-AOC Rejected being higher than L1 bidder. | |
| 4 | L4₹19.8 L+₹2.6 L (15.4%)Rejected-AOC BAID COMPLEX R K CHOUDHURY ROAD KUMAR PARA GUWAHATI 781001 ASSAM | GUWAHATI | KAMRUP METRO | ASSAM | 781001 | L4 | Rejected-AOC Rejected being higher than L1 bidder. | |
| 5 | L5₹20.1 L+₹2.9 L (17.1%)Rejected-AOC | L5 | Rejected-AOC Rejected being higher than L1 bidder. |
Tender Value
Refer Docs
EMD Value
₹35,200
Closing Date
18 Oct 2021, 6:00 pmClosed
AGE (I) AF Digaru
AGE (I) AF Digaru PO Digaru Dist Kamrup Assam 782401
SPECIAL REPAIR FOR REPLACEMENT OF ELECTRICAL FITTING WITH ALLIED WORKS SERVICE, PROVISION OF PARKING SHEDS AND ROOF TRUSS FOR STAGE AT AF STN DIGARU.
2021_MES_478092_1
8509/E8 of 2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
Digaru
MES contractor enlisted as class E cat a(i) and b(i) having deposited standing security of Rs 53,000/- with dept.
5 documents required · 5 mandatory
₹500
Yes
AGE (I) AF Digaru
₹35,200
Yes
29 Dec 2021
27 Sept 2021
20 Oct 2021
27 Sept 2021
18 Oct 2021
13 Oct 2021
Amount
JOB NO.: 51ASP/MR/02/2021-22
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 sqm on plan and and not exceeding 1.5m in depth and getting out in soft loose soil complete all as specified and directed.
M&L for PCC (1:4:8) type D2 using 40 mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
M&L brick work with sub-class 'B' bricks straight or curved on plan exceeding 6M mean radius built in CM 1:4 complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soft / loose soil complete all as specified and directed.
Removing excavated materials exceeding 1.50KM but not exceeding 5.00KM (outside MOD) from starting point and depositing where directed by Engr-in-Charge.
M&L for rendering in CM (1:4), 5 mm thick on brick / concrete surfaces finished even and fair without using extre cement complete all as specified and directed.
M&L for Reinforced cement concrete (nominal mix) type B1 (1:2:4) (using 20 mm graded aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for Reinforced cement concrete (nominal mix) type B1 (1:2:4) (using 20 mm graded aggregate) as in as in columns, pillars, piers, posts etc. complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for Mild steel TMT bars 06mm to 08mm dia cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for Framework to side of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces square, rectangular or polygonal complete all as specified & directed.
S&F for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161 - 1979 grade St.-240 or other cuting plates complete all as specified and directed.
M&L for two coats of synthetic enamel paint over a coat of red oxide primer on newly untreated surfaces of steel over 10cm in width or girth not otherwise described complete all as specified and directed.
JOB NO.: 51ASP/MR/01/2021-22
Excavation in post holes (or similar holes) each soft / loose soil not exceeding 0.5 CUM, getting out, returning, filling in and ramming earth or broken rubble mixed with earht around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance not exceeding 50m and making good surface complete all as specified and directed.
Surface excavation not exceeding 30cm deep and averaging 15cm and getting out soft /loose soil complete all as specified and directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft loose soil complete all as specified and directed.
M&L for PCC (1:4:8) type D2 using 40 mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
M&L brick work with sub-class 'B' bricks straight or curved on plan exceeding 6 M mean radius built in CM 1:6 complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soft / loose soil complete all as specified and directed.
Removing excavated materials exceeding 1.50 KM but not exceeding 5 KM (outside MOD) from starting point and depositing where directed by Engr-in-Charge.
Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM (1:4) complete all as specified and directed.
M&L for Hardcore of broken stone boulder of gauge not exceeding 63 mm deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for 100 MM thick PCC 1:4:8 type D2 using 40 mm graded aggregate as in floors complete all as specified and directed.
M&L for 100 MM thick PCC 1:2:4 type B-1 using 20 mm graded aggregate as in floors complete all as specified and directed.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 or other cuting plates complete all as specified and directed.
S&F Steel work such as wind ties for roof including securing bolts complete all as specified and directed.
M&L for two coats of synthetic enamel paint over a coat of red oxide primer on newly untreated surfaces of steel over 10cm in width or girth not otherwise described complete all as specified and directed.
M &L for preparation of new steel surfaces and applying two coats of black bituminious paint exceeding 10cm in width or girth complete all as specified and as directed.
S&F Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & directed.
JOB NO.: 51ASP/SR(E&M)/03/2021-22
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
Material and Labour for point wiring with FR PVC insulated unsheathed, stranded copper conductor cable single core 1.5 Sqmm for one light point controlled by one one way switch incl one PVC insulated, un sheathed Single core stranded/solid copper conductor cable of size 1.5 Sqmm for continues earth wire .drawn in and including PVC heavy duty casing capping 20/25 mm width complete with all accessories including sheet metal MS box of suitable size of 1.2mm thick or PVC rectangular switch board of suitable size incl 3.0 mm thick laminated sheet cover and fixed with brass screws, cap washers etc to be fixed flushed on wall including white washing/colour washing/distembering to match the disturbed surfaces complete all as directed by Engr -in Charge.
All as per item No- 3.02 above but for one fan point controlled by one way switch.
All as per item No- 3.02 above but for one 3 pin multi purpose 5 Amps socket outlet independent with 1.5 sqmm cable size.
All as per item No- 3.02 above but for one 3 pin socket outlet independent 15 Amps with cable 4 sqmm size.
Supply and fixing switch piano flush type, single pole, one way, 5 amps 230 volts complete all as specified & directed.
Supply and fixing switch socket combination 5 Amps 2/3 pin flush type complete all as specified & directed.
Supply and fixing switch socket combination 3 pin 16 A flush type complete all as specified & directed.
Supply and fixing ceiling rose, surface bakelite 65x50 mm three terminal complete all as specified & directed.
Supply and fixing stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required complete all as specified & directed.
S&F LED tube light fitting 1 x 18W, 220 V AC decorative box type with driver, holder including LED tube light connecting with 3 core flexible copper cable of suitable size from ceiling rose complete all as specified & directed.
S&F Flood light fittings complete,Pinnacle type 50 Watt LED new generation energy saving roadway luminaire IP-66 degree of protection complete all as specified and as directed.
S&FFlood light fittings complete, Pinnacle type 120 Watt LED new generation energy saving roadway luminaire IP-66 degree of protection complete all as specified and as directed.
Taking down old unserviceable switch fuse unit / MCB / MCCB DB with MCBs etc for necessary replacement complete all as specified & directed.
Supply and fixing of MCB SPN DB 8 way with Double door made of sheet steel phos phatised, powder painted with bus bar, neutral link, earth bar and Din rail, 230 Volts complete all as specified & directed.
Supply and fixing of MCB SPN DB 12 way with Double door made of sheet steel phos phatised, powder painted with bus bar, neutral link, earth bar and Din rail ,230 Volts complete all as specified & directed.
Supply fixing, connection and testing MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 32Amps complete all as specified & directed.
Supply fixing, connection and testing MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 40- 63Amps complete all as specified & directed.
Supply fixing, connection and testing MCB SP 6-32 Amps complete all as specified & directed.
Taking down Old U/S submain wiring of any size & any capacity from its existing position complete all as specified & directed.
M & L Sub main wiring with two single core multistranded copper cable of 4.0 Sqmm & one solid copper cable of 4.0 Sq.mm for contineuous earth wire both PVC insulated & un- sheathed drawn through and including PVC heavy duty casing capping 20/25 mm width complete with all accessories or to be fixed on wall respectively including white washing/colour washing/distembering to match the disturbed surfaces complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60cm x60cm x6.3mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised earth lead wire 4.0mm, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe light grade 32mm bore light grade from earthing test point or main controling switch as directed including providing funnel with 20mm bore GI pipe light grade, wire mesh,charcoal or coke and common salt in alternative layer of 15 cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 50mm thick cover of RCC (1:2:4) (re-inforced with 8mm dia TMT bar @15 cm C/C bothways and MS bar handle made of 10mm dia bar) including necessary earth work in excavation, returning in and removal of surplus soil to a distance not exceeding 50mtr, all as per electrical plate No 3 of MES Schedule Part-I including earthing pit cover etc. complete all as specified & directed.
Earth continuity conductor fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing as required 25 x 4mm GI strip complete all as specified & directed.
Supply, laying, jointing and testing XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with stranded aluminum conductor 1100 volts grade, laid in trenches / duct / on pole including all necessary fizing arrangement such as lugs, glands end termination etc of cross sectional area 35 Sqmm 3.5 core complete all as specified and directed.
Excavation in trenches, not exceeding 1.50m wide and not exeeding 1.50m in depth for foundations, trenches of cable or pipe lines etc or and getting out in soft / loose soil complete all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all specified and as directed.
Removing excavated materials (soil) to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meters above the starting point complete all as specified and directed.
M&L for sand cushioning with coarse sand in trenches for protection of underground electric cable, spread to uniform 23 cm thickness and punned down gently to 18 cm after Note:- Compacted thickness shall be measured and paid seperataly.
Supply and laying well burnt sub class B bricks old size bricks, laid flat dry, in trenches with width of the bricks laid to the axis of cable for cable protection complete all as specified and as directed.
M/S B.H. ENTERPRISE
Ms N D Enterpise
R.K.ENGINEERING ASSEMBLE
FRIENDS ENTERPRISE
M/s Dhruv Enterprises
M/S Vimal Enterprise
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .