Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹17.5 LAccepted-AOC | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹17.5 L+₹5,804.10 (0.33%)Rejected-Finance | L-2 | Rejected-Finance other than L-1 | |
| 3 | L-3₹17.9 L+₹49,032.45 (2.81%)Rejected-Finance | L-3 | Rejected-Finance other than L-1 | |
| 4 | L-4₹18.1 L+₹61,815.90 (3.54%)Rejected-Finance B1 DAYA NAGAR SHAMSHABAD ROAD RAJPUR CHUNGI AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | L-4 | Rejected-Finance other than L-1 | |
| 5 | L-5₹18.3 L+₹80,404.45 (4.61%)Rejected-Finance | L-5 | Rejected-Finance other than L-1 |
Tender Value
Refer Docs
EMD Value
₹37,600
Closing Date
9 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh A K Dubey, IDSE , SE CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
SPL REPAIR TO BLDG NO NP-08 AND P-68 AT NCCIU UNDER GE (NORTH) UDHAMPUR
2020_MES_390845_1
CWE/U(N)-78/2020-21
Open Tender
Civil Works
Item Rate
180 days
Udhampur
AS PER TENDER
7 documents required · 7 mandatory
₹500
GE (North) Udhampur
₹37,600
Yes
13 Jan 2021
29 Oct 2020
11 Dec 2020
29 Oct 2020
9 Dec 2020
27 Nov 2020
60 days
Amount
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, removing all type of vegetation (like peeple tree etc) scrubbing down with water complete, all as specified and as directed by Engr-in-Charge.
10mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:6, finished even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
15 mm thick rendering in two layer (10mm + 5mm) on fair faces of brick /concrete on wall including facia chhajja etc.surfaces in cement mortar 1:4 and finished even and smooth without using extra cement including mixing Liquid water proofing compund in the proportion as mentioned in manufacturer's instructions complete all as specified and as directed by Engr-in-Charge. Note : Water proofing compund to be measured and paid for separately as supply only.
5mm thick rendering on brick or concrete surfaces as in ceiling in cement mortar 1:3, and finish the surface even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), complete all as specified and directed by Engineer-in Charge.
Description all as per item No 5 above but area exceeding 1.50 square metre and not exceeding 4 square metre each.
Taking down shutters of any description exceeding 1.00 square metre and not exceeding 2.00 square metre each complete, all as specified and directed by Engineer-in charge.
Pressed steel frames for doors, made out of 1.25 mm thick MS sheet, with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete, of frame size 125 mm x 60 mm, including one shop coat of red oxide zinc chrome primer, complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 8 above but of frame size 105 mm x 60 mm.
35 mm thick, factory made, 2nd class hard wood, plain framed, paneled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces, the size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, complete all as specified and directed by Engr in Charge.
Description all as per item No 10 above but glazed and skeleton shutter with sash bar for glass/wire gauge.
Providing cement concrete 1:3:6 type C-0 using 12.5mm graded crushed stone aggregates for, filling as in the pressed steel door frame/hold fast complete all as specified.
Dismantling of steel windows/ventilators any description and fixed in any position including grill etc, complete all as specified and as directed by Engr-in- Charge.
Factory made mild steel ventilators box type with upper top hung shutters and bottom fixed type shutters including pintol hinges, steel peg stay and one shop coat of red oxide primer complete all specified. Note : i) The window shall be fabricated as per Drg No CEUZ/TD/1517/15 Sheet 1/3 to 3/3. ii) MS fillets, glazing, wire gauge shall be measured and paid for separately
Factory made mild steel window box type glazed and gauzed shutters with side hung including pintol hinges, steel peg stay , locking arrangement with glazing & gazing bars dovetailed or welded and one shop coat of red oxide primer complete all specified. Note : i) The window shall be fabricated as per Drg No CEUZ/TD/1517/15 Sheet 1/3 to 3/3. ii) MS fillets, glazing, wire gauge shall be measured and paid for separately
Description all as per item No 15 here in before but without glazing bar complete all as specified and as directed. Note : i) The window shall be fabricated as per Drg No CEUZ/TD/1517/15 Sheet 1/3 to 3/3 ii) MS fillets, glazing, wire gauge shall be measured and paid for separately
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar, barred iron doors; ladder, framed balusters; railing; frame work for water tanks, cooler stand etc and similar work conforming to FE 290-0 or Gde-E-165, complete all as specified and as directed.
S&F Aluminium window air tight of powder coated frame made of size 100mm x 45mm of section thickness- 1.50mm thick and shutter stiles made of section 80mm x 45mm x 1.5mm thick with or without rebates, with 5.5mm thick tinted glass fixed with aluminium beads, including GAUZED AND GLACED SHUTTER, necessary jointing cleats/anodised aluminium fillets/aluminium glazing clips with rubber gasket, with aluminium fittings such as aluminium butt hinges 100mm long 03 Nos, aluminium anodised tower bolt 100mm long 02 Nos, aluminium anodised bow handles 100mm 01 No, aluminium hook and eye 150mm 01 No, in each shutter including aluminium grill of 5 to 6 dia, size of mesh not exc 7.5cm in either direction, as approved by GE, complete all as specified. Note:- All fitting shall be of ISI marked except cleats ) sizes of each shutter shall be as per site requirement all as directed and specified
S&F powder coated door air tight of anodised frame made of size 100 mm x 45mm of section thickness -1.50 mm thick with one or more rebates including jointing cleats etc for fixing aluminium anodised door shutter fully panelled (two no of panels on each shutter) with 5.5 mm thick tinted glass as in panels shutter rail made of 80mm x45 mm of sheet thickness 1.50 mm (Top and bottom rails and stiles) single /double leaf side hung type including necessary jointing cleats anodised aluminium fillets/ glazing clips with rubber gasket with aluminium fittings such as aluminium anodised tower bolt 200mm long 03 No for each door, aluminium anodised bow handles 150 mm 'D type 02 nos for each shutter, mortice locks 6 lever make harrison one on each door, door shutter mounted on bottom double action floor spring hydrailically regulated made up of 1.25mm thick aluminium alloy sheet foundation box , main body with stainless steel cover, governing mild steel heavy duty and door shutter top mounted on aluminium alloy pivot. -01 No on each shutter, bottom and floor stoppers, Complete all as specified. Note : All fitting shall be of ISI marked except cleats) sizes of each door shall be as per site requirement all as directed and specified.
Floor door spring for aliuminium doors including fixig , cutting, drilling and making good all damaged portion, complete all as specified and as directed by Engr-in-Charge and all as per manufacuturer's instructions.
Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, with particle board core, supplying & fixing in frame at site as per specification & drawing as per specification & drawing, complete all as specified and as directed by Engr-in-Charge.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube in opening as per specification & drawing, complete all as specified and as directed by Engr-in-Charge.
4mm thick Sheet glass, ordinary quality and glazing with oil putty in square or rectangle, area n exc 0.5 sqm in each pane complete all as specified and as directed by Engr-in-Charge.
4 mm thick figured glass (frosted) ,pin head type and glazing with oil putty not exc 0.50 Sqm in each pane fixing to window/ventilator complete all as specified and as directed.
Preparation of new wooden or wood based surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over and including a coat of pink primer, complete all as specified and as directed by Engr-in-Charge.
Preparation of new steel and iron surfaces exceeding 10cm width or girth and applying two coats of synthetic enamel paint over preprimed surfaces, complete all as specified and as directed by Engr-in-Charge.
100mm butt hinges ,medium weight ,stainless steel all as complete all as specified and directed.
150 mm aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. (ISI Mark)
150 mm aluminium handles, extruded aluminium alloy handles, fcast type, anodised complete all as specified and directed. (ISI Mark)
150mm long, mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed, complete all as specified and directed by Engr-in- Charge.
125 mm long, mild steel pressed handles, oval type, stove enamelled black complete all as specified and directed by Engr-in- Charge.
300mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified and as directed by Engr-in-Charge.
Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and as directed by Engr-in-Charge.
Mild steel, 150 mm, ordinary pattern helical door spring including roller and roller plate fixed to wooden or steel frames with welding/fitted with screws etc., complete all as specified.
Vitreous china water closet, 'Orissa pattern, including lime concrete bedding, size 580 x 440 mm white with integral foot rests excluding flushing cistern and flush pipe but including connection to trap, anti syphonage pipe etc. complete fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
10 ltr capacity PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with twin flush provision, complete all as specified and as directed by Engr-in-Charge.
Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for, complete all as specified and as directed by Engr-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engr-in-Charge.
Providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified.
25 mm thick, Plain cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in sub base for laying floor finishes including finishing the surfaces even and rough without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Machine cut kota stone slab flooring 18-20 mm thick over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including Screed bed or bedding layer of mortar 20mm thick in cement mortar 1:3, complete all as specified.
Machine cut kota stone slab flooring 18-20 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 10 mm thick CM 1:3 mortar backing for fixing the stone slab, complete all as specified.
150mm wide strip of makrana white marble 18-20 mm thick machine cut, bedded jointed and pointed with grey cement slurry including cutting and polishing over and including 20 mm thick CM 1:3 mortar backing for fixing the stone slab, complete all as specified.
Glazed coloured ceramic tiles 350x250mm or 450 x 350 mm and 6 to 7mm thick in vertical surfaces like dado/skirting, etc., set and jointed in neat cement slurry and pointed in coloured cement to match, including 10mm thick backing layer of cement mortar in 1:3 to receive tiles in verticle surfaces, complete all as specified and as directed by Engr-in-Charge.
Virified Ceramic tiles light shade 10 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the existing surfaces over and including 15 mm thick screed bedding/ backing layer in CM 1:4, complete all as specified and as directed by Engr-in-Charge.
Non skid, light coloured, white printed ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in white cement to match, including 10 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes , complete all as specified and as directed by Engr-in-Charge.
18-20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including cutting and polishing over and including 15 mm thick screed bedding/ backing layer in CM 1:3, complete all as specified and as directed by Engineer-in-Charge.
Dismantling of cast iron or reinforced concrete drain pipes, any size jointed in cement mortar and taking out of trenches or fixed to wall, if required complete all as specified and as directed by Engr-in-Charge.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints fixed to wall or in floors of 100mm bore, complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 49 above but fixing only.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints fixed to wall or in floors of 75mm bore, complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 51 above but fixing only.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints laid in trenches or in floors of 50mm bore, complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 53 above but fixing only.
75mm Cast iron floor traps with grating including jointing to waste pipe fixed cncrete type B1 (1:2:4). complete all as specified and as directed.(ISI Mark)
Stack clamps made out of 50 x 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 110 mm bore pipe, complete all as specified and as directed by Engr-in-Charge.
100 mm bore cast iron bends (any radius), with duck's foot or heel rest, suitable for spun pipes, ISI marked, complete all as specified.
75 mm bore cast iron bends (any radius), with duck's foot or heel rest, suitable for spun pipes, ISI marked, complete all as specified.
Vitreous china urinal, half stall type white incl CP Spray Nozzale including PVC waste pipe, providing and fixing plugs bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement ,(Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe), fixed in repair, complete all as specified.
Dismantling wall and ceiling boards (fibre pulp, insulation etc) or insulation boards / slabs / blankets, any thickness, including cover fillets, complete all as specified and as directed by Engr-in-Charge.
False ceiling with Everest Fibre Cement Designer tile Ivory/white painted (High Pressure Steam Cured) of 4mm thickness (as per IS-14862) of size 595mmx595mm and any one of the design (occeanic , lake & hill, cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanised @120 gms, both sides inclusive) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0.30mm thick sheet and cross T of size 15x32mm made of 0.30mm sheet spaced between main T at 600mm c/c from a grid of 600x600mm and wall angle of size 15x20mm made of 0.30mm thick sheet and laying false ceiling tiles in the grid including required cutting/making opening for services like diffusers grills, light suspended from ceiling using GI soffit cleats fixed to existing rafters, purlin etc with dash fastners Gl adjustable rods of 3mm dia with galvanised butterfy level clips, spaced at 1200mm c/c along main T, bottom exposed width of 15mm of all T-sections shall be centre black pre-painted with polyester paint and having a load bearing capacity of 12 kg/sqm and refixed all existing electric wiring and fixture including dismantling of existing false ceiling, complete at all heights as directed by Engr-in-Charge.
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings including ridges, complete all as specified and directed.
Pre-painted coloured corrugated profiled Galvalume/Zincalume sheet with min 0.50mm TCT with BTM of 0.45mm thick conforming to IS -513(AZ-150 GSM,Al Zn alloy metallic coating 550MPA yield stress as per AS-1397),as in roof covering/clading to wall fixed with self taping screws, colour/exterior coat of silicon modified polyster/ BHP x RW paint system 20 micron top coat applied over 5 micron primer and a micron polyster back coat applied over 5 micron primer,all fixed with galvanised self drilling self tapping fastener(12-14x55 with EPDM seals), complete all as specified and directed
Pre-painted coloured plain steel profiled Galvalume/Zincalume sheet with Min 0.50 mm TCT with BTM of 0.45mm thick conforming to IS-513(AZ-150 GSM, Al Zn alloy metallic coating 550 MPA yield stress as per AS-1397) as roof ridge colour/exterior coat of silicon modified polyster/BHPxRW paint system 20 micron top coat applied over 5 micron primer and a 5 micron polyster back coat applied over 5 micron primer ,all fixed with Galvanised self drilling self-tapping fastener (12-14x55 with EPDM seals) complete all as specified and directed.
Preparing plastered or unplastered new surfaces of walls and applying two coats of cement base paint over and including one coat of primer, complete all as specified and as directed by Engr-in-Charge.
Description all as Srl item No 66 above but removal of existing treatment including preparation of old plastered surfaces of wall.
Preparation old surfaces including complete removal of existing treatment ( white wash) and applying one coat of white wash on ceiling all as specified
Applying two coats of oil bound distemper over and including a coat of primer including preparation of new plastered/ unplastered surfaces of wall, complete all as specified & directed by Engr-in-Charge.
Preparing old plastered or unplastered surfaces of wall and applying two coats of weather proof exterior emulsion paint including preparation of surface by brooming down or steel wire brushing, scrapping down vegetation growth, efflorscent salts and trading with oil greasy spot , complete all as specified and as directed by Engr-in-Charge.
Preparation new surfaces plastered or unplastered and applying three coats of white wash on ceiling all as specified
Complete removal of old decorated surfaces of wall, chajjas, etc. including brooming down or steel wire brushing, scrapping down smoke soots, moulds, efflorescence salt, treading oil, greasy spots or washing rubbing down and applying two coats of oil bound distemper, complete all as specified and as directed by Engr-in-Charge.
TMT mild steel bars, 10mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed by Engr-in-Charge.
Precast RCC M-25 Design mix,, using 20mm graded crushed stone aggregates landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves, fins and similar articles with plain faces including all mouldings but excluding frame, set in cement mortar 1:4 complete all as specified.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc to obtain rough flat finished surface of concrete complete all as specified and as directed.
Viterous china wash basin, white flat back size 550 x 400mm incl waste couping CP 32mm dia chain and plug and porcelan stopper and CI brackets of iron 65 x 65 x 6mm embedded in PCC block with PCC 1:2:4 type B-1 incl PVC waste pipe 32mm dia & CP grating with holes with pedestal of china ware fixed in repairs complete, all as specified and as directed by Engr-in-Charge.
PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified.
Pillar taps, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe of bore 15 mm, fixing in repair, complete all as specified and as direceted by Engr-in-Charge.
Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed by Engr-in-Charge
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, but except brick complete all as specified and as directed by Engr-in-Charge.
Description all as per Srl iotem No 80 above but except bricks.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius in half brick thick built in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 82 above but except brick.
Supply and fixing stainless steel wall mounted cloth hanger with 6 peg set, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Taking up or down steel tubing of 15 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed by Engr-in-Charge.
Taking up or down steel tubing of 20 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed by Engr-in-Charge.
Rotational moulded polyethylene water storage tank , two layers, ISI marked (cylinderical vertical with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 1000 litres each including all accessories (i.e GI nipples and Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of bore 20mm/25mm (Minimum weight 210 gram) etc), incl dismantling existing water tanks, complete all as specified and as directed by Engr-in-Charge.
20 mm bore steel water tubing medium grade galvanised with and including all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings( such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and as directed by Engr-in-Charge.
15 mm bore steel water tubing medium grade galvanised with and including all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings( such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and as directed by Engr-in-Charge.
Stop valves, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm fixing in repair , all as specified.
Bib taps , cast copper alloy, chromium plated, fancy type, screwed down for iron pipe or for brass ferrule for bore of pipe 15 mm fixing in repair, complete all as specified and as directed by Engr-in-Charge.
Brass Chromium plated over head shower rose of dia 125mm with swivel joint fixed to pipe or union of 15mm bore, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Rolled mild steel work of angle iron as in frames of doors & Cup Board etc conforming to grade Fe 290 (E-165) complete all as specified.
25 mm thick flush shutters,solid core construction,with block board core and ply wood face pannels and one face is covered with decorative face veneer with lipping/frame to match all as specified.
18/19mm thick Prelaminated particle board, termit proof, chemically well pressed, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, as in kitchen cabinet, cub boards, etc including 6mm thick teak wood beading all around complete all as specified and as directed by Engr-in-Charge.
100mm size hasp and staple safty type aluminum anodized with mild steel hinges pin including bolt to hinge plate and fixed with screw complete all as specified.
150 mm aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. (ISI Mark)
Continuous ( piano) hinges mild steel ,bright finish or electrogalvanised , width of flap (when open ) 30mm , complete all as specified.
Aluminium drapory rods of 25 mm dia decorative type with wooden finish alongwith holding for brakets & end caps fix in repairs complete all as specified.
Tubular towel rails brass chromium plated, 20 mm dia, D type, 60 cm long between flanges, fixed with rawl plugs fixed in repairs complete alll as specified and as directed,
Soap dish holder, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for such as existing roof padding incl plaster etc. on roof , complete all as specified and as directed by Engr-in-Charge.
Roughening surfaces of old concrete surfaces by picking up, sweeping, cleaning and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @ 3 kg/Sqm including 15 mm thick screeding in CM (1:4) finished even and smooth mixed with water proofing compound (WPC shall be measured and paid separately). Applying bituminous primer conforming to IS-3384 @ 0.30kg/sqm, after drying of primer applying a coat of hot blown bitumen conforming to IS-702 @ 1.20 kg/sqm and layin polymeric water proofing membrane, five layerd with centre core of 90 micron high molecular density polythelene film (min weight 3kg per sqm) with end over laps not less than 150mm and side lap 75 mm and applying a coat of semi hot blown bitumen 85/25 grade @ 0.50kg/sqm and dusted over the bitumen coat and including two coats of bituminious aluminium paint complete all as specified and as directed by Engr-in- Charge.
25 mm thick, Plain cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in roof surface, complete all as specified and as directed by Engr-in-Charge.
Dismantling wrought iron or mild steel structural steel work including doors, gates but excluding framed truss etc. complete all as specified and as directed by Engr-in-Charge.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50m and making good surface as in any type of soil, complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregates as in foundation, filling and mass concrete, complete all as specified and as directed by Engr-in-Charge.
Mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240, complete all as specified and as directed by Engr-in-Charge.
Mild steel Rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails guides for sliding doors, and vertical posts of pipes sections fixed with angle cleats or other connecting plates, Fe-410-W (Gde - E -250) complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregates as in foundation, filling and mass concrete, complete all as specified and as directed by Engr-in-Charge.
Machine pressed / vibro mechenically floated coloured interlocking cement paver block ISI marked, any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 Grade, with topping of cement with imported pigment including 25 mm thick sand cushioning bed including spreading levelling watering if required, Shape shall be approved by Engr-in-Charge.
Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling, floors etc, complete all as specified and as directed by Engr-in-Charge.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLS) cable with multi stranded copper conductor wiring in and including PVC concealed conduit medium grade (ISI marked) 20mm dia and over, wall thickness not less than 2.00 mm thick , and all accessories for one light /fan/ bell controlled by one switch with 1.25mm thick pressed steel terminal anodized box concealed on walls, 3mm laminated plastic sheet cover for mounting of switches, socket outlet, regulator etc or suitable for modular type switches, socket outlet, regulator etc , fixed by suitable size of 4 Nos cadmium screws along with PVC insulated and unsheathed FRLS 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified and as directed by Engr-in-Charge.
All as per description of Serial item No 113 here-in-before but one 3 pin 5 Amp socket outlet point controlled by one push button on the same board , complete all as specified and as directed by Engr-in-Charge.
All as per description of Serial item No 113 here-in-before but one 3/5 pin 5 Amp socket outlet on independent board , complete all as specified and as directed by Engr-in-Charge.
All as per description of Serial item No 113 here-in-before but one 3/5 pin 15 Amp socket outlet on independent board with PVC insulated, unsheathed FRLS cable 2.5 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLS 2.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed by Engr-in-Charge.
Switch socket combination, 2 in 1, 3/5 pin, 5/6 Amp flush type, complete all as specified and as directed by Engr-in-Charge.
Switch socket combination, 2 in 1, 3/5 pin, 5/6 & 15/16 Amp flush type, complete all as specified and as directed by Engr-in-Charge.
Socket outlet, 2 in 1, 3/5 pin, 5/6 Amp flush type, complete all as specified and as directed by Engr-in-Charge.
Switch piano type 5 Amps single pole one way 240 volts complete all as specified and as directed by Engr-in-Charge.
Fan regulator 120W, 230V 50 C/S, flush type electronic, step type hum free suitable control speed of fan from 0 to 100 % and connecting electrically complete all as specified and as directed by Engr-in-Charge.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, complete all as specified and as directed by Engr-in-Charge.
Sub main wiring with two runs of 6 Sqmm ( 2x6 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC rigid conduit 25 mm dia ISI marked with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 6 Sqmm (1x6sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, fixed in repairs, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 6 Sqmm (2x6sqmm ) ,one run of 6 Sqmm (1x6 sqmm ) cable and one metre of conduit will be measured as one unit.
Sub main wiring with two runs of 4 Sqmm ( 2x4 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid concealed conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 4 Sqmm (1x4sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, fixed in repair, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 4 Sqmm (2x4sqmm ) ,one run of 4 Sqmm (1x4 sqmm ) cable and one metre of conduit will be measured as one unit.
Sheet metal enclosures for distribution board when MCB to be used SPN 12 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications ,fixing in repairs complete all as specified and as directed.
MCB SPN, 40 to 63 Amps, 240 Volts, rupturing capacity 10 KA including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge.
MCB SP, 6 to 32 Amps,240 Volts, rupturing capacity 10 KA including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge.
Sheet metal enclosure Single pole & neutral with 2 pin and earth plug and socket 20Amps, 240V complete with one single pole MCB of any cap from 5 to 32 Amps of breaking capacity 10KA, complete all as specified and as directed by Engr-in-Charge.
Slim linear LED lighting fixture 5 Watt LED Batten, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, CRI ≥ 70, PF ≥ 0.9, Surge protection upto 2.0 kV, shatter proof opal sheet of polycarbonate diffuser with system efficacy ≥ 100 Lm/watt, operating voltage 170-240 volts, colour temp 6500K, Low heat generating LED, complete making all connections using 1.5 Sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting complete all as per the directions of Engr-in-Charge.
Slim linear LED lighting fixture 20 Watt LED Batten, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, CRI ≥ 70, PF ≥ 0.9, Surge protection upto 2.0 kV, shatter proof opal sheet of polycarbonate diffuser with system efficacy ≥ 100 Lm/watt, operating voltage 170-240 volts, colour temp 6500K, Low heat generating LED, complete making all connections using 1.5 Sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting complete all as per the directions of Engr-in-Charge.
S&F in replacement E-Lite LED Curve lighting fixture 10/12 watt LED batten, with full base of extruded polycarbonate body environmental friendly, energy efficient ready to use pack with isolated driver, complete making all connection using 1.5 sqmm copper conductor multistrandard PVC insulated 2 core flexible cable with flexible PVC pipe from ceiling rose to fittings complete all as per the directions of Engr-in-Charge.
Supply and fixing LED Street Light fitting 25 Watt, New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 with acrylic, powder coated, pressure die cast aluminium compact high power LED tube light with heat resistant toughened Glass, Corrosion resistant, isolated driver low heat generating LED including nuts, bolts, washers with suitable size/dia 40mm GI pipe bracket for fixing of street light including making all connection, complete all as per the direction of Engg-in-Charge.
Note for Srl item No 129 to 132: (i) A certificate from the manufactures for warranty minimum upto 2 years shall be obtained and submitted to the AGE/GE (ii) Any touch up of the wall surface due to changing of fittings shall be done by contractor with similar surface finish without extra cost to the department.
XLPE insulated sheathed armored heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 16 sqmm 2 core including taking up/down old unserviceable cables. complete all as specified and as directed by Engr-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth in any type of soil, complete all as specified and as directed by Engr-in-Charge.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed by Engr-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed by Engr-in-Charge.
Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed. NOTE Only punned thickness shall be measured for payment purpose.
Brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat of size 230mmx115mmx75mm complete all as specified and as directed by Engr-in-Charge.
GI tubing light grade 40mm bore along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles complete all as specified and as directed by Engr-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4 mm dia galvanised earth lead wire by means of bolts, nuts, check nuts and washers of galvanised standard iron or steel all as specified or indicated in electrical plate no 3 of MES Part-I, including testing on completion including the material and labour of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm.
Contd Srl item No 141...... (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 15 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : (a) On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Earth continuity conductor or main earthing lead fixed wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to pole or any other indicated situation for loop earthing as required 4mm dia galvanised iron steel wire complete all as specified and as directed by Engr-in-Charge.
Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store, and applying two coats painting with synthetic enamel to ceiling fans complete, in situ by spraying including filling cavities with filler, one coat after cleaning all dust etc., making all connection using 1.5 sqmm copper conductor multi strand PVC insulated 3 core flexible cable from ceiling rose to fitting including rapair ceiling fan 1200mm sweep, oiling, greasing cleaning slot, over hauling & replacement of defective nut bolts washer etc, and rehanging all as per the directions of Engg-in-Charge.
paras ram pachiala
s l sharma and sons
MAHAJAN TRADING CO
M/S JANDIAL ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .