Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.3 LAccepted-AOC DAIRY FARM JUNCTION VIJAY BAUGH ROAD SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹43.3 L+₹77,222.50 (1.82%)Rejected-Finance OLD PAHARGAON POLY TECHNIC ROAD DOLLYGUNJ SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹43.4 L+₹87,319 (2.05%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹44.3 L+₹1.8 L (4.17%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹44.9 L+₹2.3 L (5.46%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
23 Feb 2022, 6:00 pmClosed
Garrison Engineer Haddo
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
ADDITION/ ALTERATION AND SPECIAL REPAIRS TO BLDG NO. T-25 AT JAL VIHAR AND PROVISION OF 02 X WATCH TOWERS AT NAVY PARK AREA UNDER GE HADDO, PORT BLAIR
2022_MES_505937_1
8606/GE/H/PB
Open Tender
Civil Works
Item Rate
180 days
GE Haddo Port Blair
Class D Category a (i)
9 documents required · 9 mandatory
₹500
GE Haddo
₹90,000
10 Mar 2022
4 Feb 2022
28 Feb 2022
4 Feb 2022
23 Feb 2022
18 Feb 2022
4 Feb 2022 - 14 Feb 2022
Amount
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m in depth, for foundation etc., or for shafts, wells, cess pits, manholes, pier holes etc not exc. 10 Sqm on plan and n.exc. 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
Excavating in post holes (or similar holes) in hard/dense soil each not exceeding 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm and removing surplus soil to a distance not exceeding 50 metres and making good disturbed surfaces complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each as in soils complete all as specified and as directed.
Removing excavated material (soils) to a distance not exceeding 50 metres and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M&L for hardcore using broken stone or boulders of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M&L for PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M&L for 100mm thick PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in sub base complete all as specified and as directed.
M&L for 100mm thick plain cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in levelling course, sub-floors and pavings complete all as specified and as directed.
M&L for 70mm thick plain cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in levelling course, sub-floors and pavings complete all as specified and as directed.
M&L for reinforced cement concrete (1:1½:3) type A1 (using 20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc., basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L for reinforced cement concrete (1:1½:3) type A1 (using 20mm graded stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and as directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter for rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for use and waste of formwork to sides of sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces of concrete flat complete all as specified and as directed.
M&L for pre-cast cement concrete block masonry with solid blocks made up of (1:3:6) type C1 (using 20mm graded stone aggregate), masonry exceeding 10cm in width and setting in cement mortar (1:6) complete all as specified and directed.
Taking down cement plaster of any description on brick or stone walls etc., including raking out joints, hacking for key, scrubbing down with water etc., and removal of debris to outside MD land complete all as specified and as directed.
M&L for rendering 15mm thick in CM (1:4) on fair faces of brick work or concrete, surfaces finished fair and even complete all as specified and as directed.
M&L for rendering 15mm thick in CM (1:6) on fair faces of brick work or concrete, surfaces finished fair and even complete all as specified and as directed.
M&L for applying 2 to 3mm thick wall care putty on wall surfaces complete all as specified and as directed
M&L for preparation of newly plastered surfaces of walls of any description and applying two coats of distemper oil emulsion over a coat of primer over 3mm thick cement putty including filling of cracks and holes complete all as specified and as directed.
M&L for complete removal of exisitng treatment on wall surfaces of any description and applying two coats of distemper oil emulsion over a coat of primer after levelling the undulations if any with cement putty complete all as specified and as directed.
M&L for preparation of newly plastered surfaces and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed
M&L for complete removal of existing treatment on plastered wall surfaces and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed
Dismantling stone slabs and tiles of any description or thickness in floors, aprons, risers of steps, skirting, dado etc., laid bedded and pointed in any mortar complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for vitrified ceramic coloured tiles 9 to 10 mm thick (square/ rectangular) of approved light shade, of size 600x600mm in floors etc., laid over and including 15mm thick screed bed in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for vitrified ceramic coloured tiles 9 to 10 mm thick (square/ rectangular) of approved light shade, of size 600x600mm, for work on vertical surfaces such as skirting, dados and risers to steps etc., including 10mm thick backing coat in CM (1:3), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for heavy duty parking area tiles of size 300x300x10.8mm thick, or high dimension (except thickness) of any colour any design Durastone, weather proof impact resistant, abrasion resistant exterior tiles, as in floors etc , set and jointed in neat cement slurry over and pointed in white or coloured cement to match, over and including 15mm thick screed bed in CM (1:4) complete all as specified and as directed.
M&L for 20mm thick granite slab (of approved shade), machine cut, as in floors, vertical surfaces, steps (treads/risers) and the like laid over cement mortar (1:4) and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding, polishing and rounding (chamfering) the edges complete all as specified and directed.
M&L for glossy finished heavy duty chequered cement concrete tiles 30cm x 30cm x 25mm thick, made of grey cement and pigments, machine pressed as in flooring, set, jointed and pointed in neat cement slurry laid over and including 20mm thick screed bed in CM (1:6) complete all as specified and as directed.
M&L for sand (river sand) filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M&L for machine pressed precast concrete interlocking paver block, glossy finished, any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-40 grade, made of grey cement and pigments, any pattern, laid in floors, laid dry including filleting to edges in CM (1:4) complete all as specified and as directed.
M&L for mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-410-W (Gde E-250) Quality 'B' complete all as specified and as directed.
M&L for mild steel rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates etc., conforming to Fe-410-W (Grade E-250) Quality 'A' complete all as specified and as directed.
M&L for mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-410-W (Gde-E-250) Quality 'A' complete all as specified and as directed.
M&L for mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars and similar work conforming to Fe-290 Grade E-165 complete all as specified and as directed.
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exceeding 30cm and dia of neck 12 to 20 mm complete all as specified and as directed.
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement.
M&L for preparation of new steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint of first quality over a coat of red oxide zinc chrome primer complete all as specified and as directed.
M&L for preparation of old steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed.
S&F aluminum flat iron wind ties of any size and thickness fixed with self tapping screws for fixing roofing sheets complete all as specified and as directed. NOTES: The self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers.
S&F pre-painted zinc coated aluminum sheet (Galvalume) GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F pre-painted zinc coated aluminum sheet (Galvalume) GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall/valley gutters, fixed with self tapping screws including scaffolding for a height upto 12.0 metres complete all as specified and as directed.
Note for Item No 46 & 47 The self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers. Penetration and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc., as per SSR Part-I 2009 complete.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames), area exceeding 1.5 Sqm but not exceeding 4.0 Sqm each complete all as specified and as directed.
M&L for powder coated anodised aluminium partition, window and door/ventilator with frame and shutters and grill fully or partly glazed, sliding/openable/fixed fully glazed and panels fixed with panels inserts 12 mm thick pre-laminated particle board/sheet glass including necessary jointing cleats, glazing clips, rubber beading, neoprene packing, anodised aluminium snap beading, screws, anodized aluminium fittings such as handles, aluminium butt hinges, aluminium tower bolts etc. The size of aluminium section shall be all as specified in relevant IS Code and SSR Part-I complete all as specified and as directed. NOTES: (i) Supply only floor spring, glass, Imax hinges, SS friction hinges, particle board, aluminium fly proof mesh will be measured and paid separately under relevant items of this BOQ. (ii) Weight of aluminium section only shall be accounted for the purpose of payment. However unit rate quoted shall be deemed to include for cost of rubber beading, neoprene packing, fittings such as handles, butt hinges, tower bolts, rollers for sliding windows, locking arrangement and fixing only of panel inserts of glass/ particle board/aluminium fly proof mesh etc. (iii) Weight of aluminium handle, butt hinges, tower bolts shall not be accounted for payment purpose.
S&F Second class hard wood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints including preservative treatment complete all as specified and as directed.
S&F 38mm thick rubber wood panelled shutter (02 Panels), with styles of 100mm, bottom and middle rail 100mm, top rail 150mm and panelled with 18mm rubberwood all as specified and as directed
S&F 38mm thick rubber wood glazed and skeleton shutter (04 Panels), with styles of 100mm, bottom and middle rail 100mm, top rail 150mm and panelled with glass or aluminium wire mesh all as specified and as directed. ( Note: Glass & wire mesh will be measured and paid separately)
Supply only 5.5 mm thick plain sheet glass, ordinary quality and glazing with aluminium glazing clips in square, not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Supply and fix 5.5 mm thick plain sheet glass, ordinary quality and glazing with aluminium glazing clips in square, exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Supply only 8 mm thick plain sheet glass, ordinary quality and glazing with aluminium glazing clips in square, exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Supply and fix 12mm thick sheet glass, ordinary quality, in squares exc 0.5 Sqm each pane and solar control film 25 micron reflective type sicked to glass panes as per instructions of manufactures
S&F Solar control film 25 micron reflective type (Garware sun control or equivalent) complete all as specified and as directed.
S&F 18mm thick rubberwood pelmet box in narrow widths, n exc 15cm Each, rebated or flat edged all as specified and as directed
M&L for preparation of new/old wooden surfaces and applying melamine polish through the process of sanding with wood sanding paper of size 60 & 80 and applying wood filler mixed with NCD thinner including applying wood putty on shabby/ nailing area and sanding with sand paper of size 120 and applying sealer and walnut colour stainer ad sanding with sand paper of size 320 ad melamine polishing with spray application and again sanding with 400 sand paper and finally applying waxpol (Silicon Make) with soft fine cloth for better shining and finishing complete.
M&L for aluminium composite panel sheet of 3.0mm thick with skin thickness of 0.25mm of aluminium on both sides, sandwiched by 2.5mm polyethylene core with PVDF coating of 30.0 micron fixed over frame made up of aluminium hollow section of 25x50mm, 2.0mm thick, duly fixed to wall/ceiling with expansion fastner having panels not exceeding 1200x1200mm with necessary silicon filling, in approved pattern as in columns, beams, walls etc., complete all as specified and as directed. NOTE: Necessary scaffolding required for the work shall be deemed to include in the unit rate quoted.
Dismantling ceiling boards / wall cladding (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets and grid complete all as specified and as directed.
M&L for anodised aluminium snap grid frame work for false ceiling with size of grid 605mm x 605mm all as specified in SSR Part-I 2009, hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat iron 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long including cutting, drilling, jointing etc., including 6mm thick non-asbestos fibre cement building design boards fixed or laid/ inserted to aluminium frame work with screws complete all as specified and as directed.
M&L for seamless gypsum board false ceiling 12 mm thick including for any sunk or raised moulding with 25mm long self drilling/tapping screws having Philips head with joining compound and 48 mm wide fibre tape to provide seam less finish and including GI frame work of seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flange of 20mm and 30 mm, web of 27 mm, fixed to surrounding wall using nylon sleeves and screws at 450 mm c/c / intermediate channel 0.9 mm thick having two equal flanges of 15 mm suspended from soffit at approx 900 mm c/c with GI cleats and steel expansion fasteners with and including ceiling section (not exceeding 1.2 m length) of 0.55 mm thick having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting across the intermediate channel at 457 mm c/c including hangers 6 mm dia GI adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size, 60 mm long & expansion hold fasteners 12.5 mm dia, 40 mm long and finally applying two coats of oil bound distemper with roller finish over a coat of primer complete all as specified and as directed.
S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed
M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC Conduit of suitable size (not less than 25mm) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in CI boxes/pressed steel terminal boxes 60mm deep made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint outside and with two coats of aluminium paint inside and laminated sheet cover of 3mm thick on top for housing the switches, socket outlet etc, all as specified and as directed for the following:-
One LIGHT/FAN point controlled by one, one way 6 Amps switch.
Two LIGHT point controlled by one, one way 6 Amps switch.
Three LIGHT point controlled by one, one way 6 Amps switch.
One 6A SOCKET OUTLET point controlled by one, one way 6 Amps switch on independent board.
One 6A SOCKET OUTLET point controlled by one, one way 6 Amps switch on same board.
One BELL point controlled by one 6 Amps bell push switch.
M&L for Point wiring complete with 4.0 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC Concealed conduit of suitable size (not less than 25mm) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 4.0 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in CI boxes/pressed steel terminal boxes 60mm deep made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint outside and with two coats of aluminium paint inside and laminated sheet cover of 3mm thick on top for housing the switches, socket outlet etc, all as specified and as directed for ONE 16A SOCKET OUTLET point controlled by one, one way 16 Amps switch on independent board.
S&F modular switch, one way, one module, single pole, 6 Amps complete all as specified and as directed.
S&F modular switch, one way, one module, single pole, 16 Amps complete all as specified and as directed.
S&F modular socket, multipurpose, 2/3 pin combined, 2 module, single pole, 6 Amps complete all as specified and as directed.
S&F modular socket, multipurpose, 2/3 pin, 6/16 Amps combined, 2 module, single pole, complete all as specified and as directed.
S&F modular bell push, 6 amps, 1 module, 230 volts complete all as specified and as directed.
S&F electric bell, ding dong type, AC, 230 volts complete all as specified and as directed.
M&L for ceiling rose, three terminal, 65x20mm size, PVC/Polycarbonate, insulated body, 6A, 240 volts complete all as specified and as directed.
S&F communication module for telephone socket, RJ 11 Make: Havells (Crabtree) ACAKRTW112/ Anchor/ Bajaj
S&F starter switch of capacity 25 Amps working on 240 Volts, AC supply suitable for split type airconditioner complete all as specified and as directed. MAKE: CRABTREE Cat part No. ACTO252504 or equivalent in ANCHOR/HAVELLS/L&T
M&L for Sub main wiring complete with two runs (1P+1N) of 6.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 6.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 32mm wide rigid non-metallic PVC casing and capping and its accessories (OR) 25mm dia PVC conduit and conduit accessories fixed on surface of wall/ceiling/roof/ floor complete all as specified and as directed. NOTE: Two runs of 6.0 Sqm copper conductor, One run of 6.0 Sqmm copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length.
S&F recessed mounted 18 watts, down light round shape, LED panel light fitting with ultra bright luminarie comprising thermally conductive material, pre wired with high efficiency electronic driver with all accessories and fixing arrangements for fixing the light fitting complete all as specified and as directed. MAKE: PHILIPS Cat part No. Astra Max Metal Panel/ CROMPTON GREAVES Cat Part LSCRM-18W-CDL/NW/WW or equivalent in HAVELLS/C&S
S&F recessed mounted 6 watts, down light round shape, LED panel light fitting with ultra bright luminarie comprising thermally conductive material, pre wired with high efficiency electronic driver with all accessories and fixing arrangements for fixing the light fitting complete all as specified and as directed. MAKE: PHILIPS Cat part No. Astra Max Metal Panel/ CROMPTON GREAVES Cat Part LSCRM-6W-CDL/NW/WW or equivalent in HAVELLS/C&S
S&F wall mounting type oscillating air circulating fan with remote control, 400mm (16") sweep, 1350RPM, working on 230 volts, 50 Hz, single phase, AC supply complete all as specified and as directed. MAKE: Atomerg, Model: Efficio or equivalent in Havells/USHA/ CG
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3.5 core, 50 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., including connecting up with suitable size of lugs, glands and jointing material complete all as specified and as directed.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3.5 core, 25 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., including connecting up with suitable size of lugs, glands and jointing material complete all as specified and as directed.
M&L for HDPE DWC (Double wall corrugated) pipe of size 50mm (Outer diameter) x 38mm (Inner diameter) along with connected accessories like couplers, bends, end caps etc., laid in trenches/floors/ducts or fixed on poles/walls for as in protection of LT/ HT cable complete all as specified and as directed.
M&L for HDPE DWC (Double wall corrugated) pipe of size 77mm (Outer diameter) x 63mm (Inner diameter) along with connected accessories like couplers, bends, end caps etc., laid in trenches/floors/ducts or fixed on poles/walls for as in protection of LT/ HT cable complete all as specified and as directed.
M&L for earthing complete with GI earth plate electrode of size 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5m below normal ground level connected to 4mm dia GI earth wire as earth lead connected by means of bolts, nuts, washers and check nuts made out of galvanised iron or steel all as shown on electrical plate No. 3 of SSR Part-I connected to common earth dolly including testing on completion complete all as specified and directed. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.
S&F decorative flexible LED strip ( Warm yellow colour) of 5.0 metres length and 2 mm thick, 720 LED per metre, dimmable type, 25 Watts capacity with adapter/ driver including fixing along name board or ceiling covers with necessary fasteners complete all as specified and directed. MAKE: PHILIPS Cat part No. 31389 or equivalent in HAVELLS/ CROMPTON GREAVES/ BAJAJ
S&F LED step light, 104x104x35mm dimension, IP-44, lamp based LED integrated, 165 lumen, 5 Watts including all fixing arrangements complete all as specified and as directed. Make: Philips, Nodel No: 31435 or Equivalent in Havells/ CG/ Luker
S&F Electronic voltage stablizer of 4 KVA capacity, wall mounting type having features such as Intelligent time delay system of 2 to 4 minutes, low and high voltage cut-off protection, latest IC technology to protect from power fluctuations, thermal over load protection, wide input variation between 165 Volts to 295 Volts with output voltage stablized at 200 Volts to 240 Volts, with accuracy of +2.5% suitable for split type airconditioner complete all as specified and as directed.MAKE: V-GUARD/ Premier
Supply, install, test & commissioning of Split type air conditioner, 1.5 TR capacity,BEE 5-Star rating, having cord less remote control unit, wall mounted inverter type with built-in ioniser and plasma filter for better air quality, copper wound, electric driven, single phase, 240 volts, 50 Hz, AC supply including transporting to site, fixing of indoor and outdoor units with necessary wall mounting brackets, necessary copper piping minimum 8 RM for connections, cutting, bending, brazing, proper insulation on copper pipe and all other pipes, PVC drain pipe upto ground level, installation complete with all accessories including connecting electrically between indoor and outdoor units with suitable size of PVC insulated multistranded copper conductor, 01 No spare PCB for each AC complete all as specified and as directed. MAKE: BLUESTAR /VOLTAS/LG/HITACHI NOTE: All connected pipes shall be covered with PVC casing and capping.
S&F Out door type dust & vermin proof LT feeder pillar box panel with following specifications Fabrication Details : CPRI approved Main frame 3.15mm thick CRCA sheet, partition sheets / covers / doors of 3.15 mm thick CRCA sheet, gland plates 3.15 mm thick MS sheet (undrilled), base frame on ICMS channel with provision of incoming and outgoing cable entry at the bottom for outdoor installation, free standing floor mounted with degree of protection IP-54 and locking arrangements complete all as specified and as directed. Bus bar details: Material shall be aluminum bus bar, 200 Amps for 3 phase and 125A for Neutral Painting Details : Pillar box shall be powder coated and painted with two coats of synthetic enamel spray paint over a coat of redoxide primer and marking of details of capacity/ rating/ incoming/ outgoing/ danger notice board in capital English alphabets with red colour radium sticker of required size.
Accessories for Pillar Box: (i) 0-500V Digital voltmeter - 01 No (Flush type) (ii) 0-500A Digital Ammeter - 01 No (Flush type) (iii) Indication Lamps (LED) RYB - Set of 03 Nos. MAKE: L&T / BINAY/ ELMEASURE (iv) Incomer:-125A, 4 pole, MCCB - 1 No (v) Outgoing:- 100A, 4 pole, MCCB - 1 No NOTES: (i) The unit rate quoted is deemed to include the cost of MCCBs, Volt meter, Ammeter, Indication lamps and connected control wiring with 2.5Sqmm FRLS copper conductor necessary spreader links, lugs, glands and connecting of cables as per site conditions and complete all as specified and as directed. (ii) Drawings must be approved by Engineer-in-Charge before fabrication of LT Panel.
LOOK UP ENTERPRISES
AMR TRADERS
Nirman Construction Company
Govinda Swamy Construction
M/s K Moorthi
CHANDER SEKER ENTERPRISE
SKV Engineering
Kakolil Trade Agencies
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .