| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.9 CrAccepted-AOC | ₹4.9 Cr | 1 | Accepted-AOC Being Lowest |
| 2 | 2₹4.9 Cr+₹2.7 L (0.56%)Rejected-Finance | ₹4.9 Cr+₹2.7 L (0.56%) | 2 | Rejected-Finance Not L1 |
| 3 | 3₹5.0 Cr+₹10.2 L (2.10%)Rejected-Finance | ₹5.0 Cr+₹10.2 L (2.10%) | 3 | Rejected-Finance Not L1 |
| 4 | 4₹6.5 Cr+₹1.7 Cr (34.2%)Rejected-Finance | ₹6.5 Cr+₹1.7 Cr (34.2%) | 4 | Rejected-Finance Not L1 |
| 5 | Rejected-Technical KALU BASS SHRI DUNGARGARH BIKANER RAJASTHAN 331803 | BIKANER | BIKANER | RAJASTHAN | 331803 | - | - | Rejected-Technical Not Admitted since not enlisted Cat c vii |
Tender Value
₹4.7 Cr
EMD Value
₹5.5 L
Closing Date
26 Dec 2020, 6:00 pmClosed
CE JAIPUR ZONE
CE JAIPUR ZONE BANI PARK POWER HOUSE ROAD JAIPUR
PROVN OF WATER TREATMENT SCHEME AT MATHURA
2020_MES_321777_3
CEJZ/NIT/MTR-01 OF 2019-2020
Open Tender
Civil Works - Water Works
Lump-sum
450 days
Mathura
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,000
GE (WEST) MATHURA
₹5.5 L
Yes
2 Feb 2021
5 Dec 2020
29 Dec 2020
5 Dec 2020
26 Dec 2020
14 Dec 2020
Amount
Lump sum price worked out by contractor for "Building works" as listed in Schedule `A' Part-I*Above/below the lump sum price inserted by the MES in Schedule `A' Part-I
Lump sum price worked out by contractor for "Internal Electrification" as listed in Schedule `A' Part-II*Above/below the lump sum price inserted by the MES in Schedule `A' Part-II
Lump sum price worked out by the Contractor for "Road Path" as listed in Schedule ‘A’ Part-III **Above / below the lump sum price inserted by the MES in Schedule ‘A’ Part-III
Lump sum price worked out by contractor for "Area Drainage" as listed in Schedule `A' Part-IV*Above/below the lump sum price inserted by the MES in Schedule `A' Part-IV
Lump sum price worked out by contractor for "External water supply" as listed in Schedule `A' Part-V*Above/below the lump sum price inserted by the MES in Schedule `A' Part-V
Lump sum price worked out by contractor for "External Electrification" as listed in Schedule `A' Part-VI*Above/below the lump sum price inserted by the MES in Schedule `A' Part-VI
Lump sum price worked out by contractor for "Compound Wall" as listed in Schedule `A' Part-VII*Above/below the lump sum price inserted by the MES in Schedule `A' Part-VII
Lump sum price worked out by contractor for "Excavation and earth work" as listed in Schedule `A' Part-VIII*Above/below the lump sum price inserted by the MES in Schedule `A' Part-VIII
Lump sum price worked out by contractor for "Internal water supply" as listed in Schedule `A' Part-IX*Above/below the lump sum price inserted by the MES in Schedule `A' Part-IX
Lump sum price worked out by the Contractor for Schedule `A' Part-X (rate against Srl No.10.01 to 10.42 shall be quoted by the Contractor)
Supply, installation, testing and commissioining of Centrifugal End Suction back pull out, pump set conforming to IS for feeding to filters. The pump shall be suitable for the given duty points. Each pump is of 100 % Capacity ( There are total 6 pumps. Out of six pumps, four will be working and two will be remain as stand by as shown in drawing) (i) Water Quantity for each pump - 2315 LPM (ii) Static Head - 30 M (iii) Speed - 1450 RPM (iv) Impeller - Bronze (v) Shaft - High Tensile steel (vi) Pump/motor body- CI (vii) Seal - Mechanical (viii) Motor - Suitable HP, Sqirrel Cage SPDP,Class 'B' Insulation, energy efficient conforming to IS 12615 (ix) Starter - Soft star delta starter including over voltage under voltage relay and phase preventer system. (x) Base frame - Fabricated MS (xi) Foundation - RCC/PCC Foundation as per OEM Recommendations Note:The pumps shall be provided with Anti Vibration Pads and RCC/Cement concrete Foundation. Rubber bellows shall be provided on suction and discharge sides for vibration isolation. 1 Nos 150 mm dia dial type pressure gauges on outlet of each pump shall also be provided. Cost of all these items are deemed to be included in quoted cost of pump.
Supply, fixing , testing and commissioning multi grade sand filter, frontal pipe work with 150 mm dia valve , pressure gauge- 02 Nos, suitable for flow rate 139 cum/hr and maximum working pressure 3.5 kg/sqm .specifications of filter followings:- (a)Total height (HOS) filter media plus water storage at top and bottom- 1875 mm. (b) Height of filter media- 915 mm. (c) Dia of filter- 2.60 meter (d) Flow of water in filter - 0.04cum/s ( e) Velocity of water in filter - 30.0 m /hr
Supply, fixing , testing and commissioning activated carbon filter frontal pipe work with 150 mm dia valve , 02 Nos pressure gauge ,suitable for flow rate 139 cum/hr and maximum working pressure 3.5 kg/sqm of the following specification (a) Total height (HOS) filter media plus water storage at top and bottom - 1875 mm (b) Height of filter media - 1000 mm. (c) Dia of filter- 3 meter (d) Flow of water in filter - 0.04 cum/s (e) Velocity of water in filter- 24 m /hr
Supply, fixing, testing and commissioning chlorine dosing system comprising of followings:- (a) Sodium hypochlorite transfer system (i) Hypo transfer pump horizontal, centrifugal type of capacity 1 cum made out of polypropylene plastic qty -02 Nos (ii) Inlet and outlet ball valves 25 mm PVC for transfer pumps qty - 04 Nos (iii) Y type strainer 25 mm PVC for transfer pumps - 02 Nos (iv) Flexible hose pipe PVC 25 mm – 25 RM (b) Sodium hypo chlorate storage system (i) Sodium hypo chlorate storage tank of capacity 1000 litrs made out of FRP - 01 Nos (ii) Drain valve ball type PVC 50 mm qty- 02 Nos (iii) Ball valve outlet 25 mm PVC - 01 No (c) Dosing unit:- (i) Dosing pump (metering pump) made out of polypropylene plastic of capacity 0-10 LPH and 5 kg/sqcm working pressure - 06 Nos. (ii) Dosing pump inlet and outlet ball valve PVC 15 mm qty- 12 Nos (iii) Y type strainer 15 mm PVC- 06 Nos (d) Control panel starter cum relay based- 01 No (e) Supply only sodium hypo chlorate having 12% chlorine in 50 litre drums-1000 litres Note: - Power and control cable, PVC pipe with fittings 15 mm and colour comparison test kit deemed to be included in quoted rate.
Design, supply, installation , testing & commissioning single girder over head II class gantry HOT crane of 1.0 ton capacity suitable for indoor operation heavy duty crane having span 5.26 mtr, bay length 11 mtr, lift 3 mtr(hook height ), suitable for horizontal , cross and vertical upward and downward direction movement including main frame bridge girder/end carriage trolley with frame , crasbuffers, shafts, wheels, gears(IS-4460),chain pulley block 1.0 Ton capacity with chain hook, confirming to IS:807, IS:3832 all as specified and directed. Note: - (i) Rail supporting girder (ISMB) will be in lump sum part of pump house Bldg and to be shown in building drawing. (ii) All drawings & design of crane girder will be as per OEM’s recommendations and will be approved by AO before execution of work.
Supply, laying, fixing, testing and commissioning of DI Double Flanged Pipes centrifugally cast spun water pipe of 250 mm nominal dia Pipe as per IS 8329 in standard length suitable for flanged/welded with inside cement mortar lining with one rubber ring . The pipe shall be of class K-9. The pipe shall be laid above ground in plant and up to filters as shown in drawing. After activated carbon filter pipe line will be laid underground. Contractor shall quote rate accordingly. Note:(a) All pipes, pipe supports,structures shall be painted with 2 coats of synthetic enamel paint over a coat of red oxide primer and lettering with white paint including marking direction of flow. ' (b) Excavation, returning , filling shall be measured separately and paid for schedule A Part-VIII. (c) Pipes above ground shall rest on brick pillar at min 1 mtr interval. Cost of brick pillar shall be paid separately for schedule A Part - V.
Supply, laying, fixing, testing and commissioning of DI Double Flanged Pipes centrifugally cast spun water pipeof 400 mm nominal dia Pipe as per IS 8329 in standard length suitable for flanged/welded with inside cement mortar lining with one rubber ring . The pipe shall be of class K-9. The pipe shall be laid below ground in plant and up to filters as shown in drawing. After activated carbon filter pipe line will be laid underground. Contractor shall quote rate accordingly. Note:(a) All pipes, pipe supports,structures shall be painted with 2 coats of synthetic enamel paint over a coat of red oxide primer and lettering with white paint including marking direction of flow. ' (b) Excavation, returning , filling shall be measured separately and paid for schedule A Part-VIII. (c) Pipes above ground shall rest on brick pillar at min 1 mtr interval. Cost of brick pillar shall be paid separately for schedule A Part - V.
Supply, laying, fixing, testing and commissioning of DI Double Flanged Pipes centrifugally cast spun water pipeof 150 mm nominal dia Pipe as per IS 8329 in standard length suitable for flanged/welded with inside cement mortar lining with one rubber ring . The pipe shall be of class K-9. The pipe shall be laid above ground in plant and up to filters as shown in drawing. After activated carbon filter pipe line will be laid underground. Contractor shall quote rate accordingly. Note:(a) All pipes, pipe supports,structures shall be painted with 2 coats of synthetic enamel paint over a coat of red oxide primer and lettering with white paint including marking direction of flow. '(b) Excavation, returning , filling shall be measured separately and paid for schedule A Part-VIII. (c) Pipes above ground shall rest on brick pillar at min 1 mtr interval. Cost of brick pillar shall be paid separately for schedule A Part - V.
Supply, fixing , testing and commissioning valve(Manual) butterfly cast iron body long neck ,stainless steel disc, square driven anti blow out shaft in one piece design manually operated of size 400 mm with standard accessories like strainers, gauges, disc, nitrile rubber seal and ‘o’ ring etc. PN-1 for filtration plant comprising of following standards:- (a) Design :– BSEN593 (b) Face to face dimension :– DIN/EN558-1,series20(K1) (c) Hydraulic test :– EN12266-1,P10/P12 (d) Waste water pressure test :– EN12266-1 (e) Comforming to IS:13095
Supply, fixing , testing and commissioning valve(Manual) butterfly cast iron body long neck ,stainless steel disc, square driven anti blow out shaft in one piece design manually operated of size 250 mm with standard accessories like strainers, gauges, disc, nitrile rubber seal and ‘o’ ring etc. PN-1 for filtration plant comprising of following standards:- (a) Design :– BSEN593 (b) Face to face dimension :– DIN/EN558-1,series20(K1) (c) Hydraulic test :– EN12266-1,P10/P12 (d) Waste water pressure test :– EN12266-1 (e) Comforming to IS:13095
Supply, fixing , testing and commissioning valve(Manual) butterfly cast iron body long neck ,stainless steel disc, square driven anti blow out shaft in one piece design manually operated of size 150 mm with standard accessories like strainers, gauges, disc, nitrile rubber seal and ‘o’ ring etc. PN-1 for filtration plant comprising of following standards:- (a) Design :– BSEN593 (b) Face to face dimension :– DIN/EN558-1,series20(K1) (c) Hydraulic test :– EN12266-1,P10/P12 (d) Waste water pressure test :– EN12266-1 (e) Comforming to IS:13095
Supply, fixing , testing and commissioning non return sluice valve with standard accessories, CI body with dual plates ,stainless steel plates, vulcanised NBR seal , both end flanged PN 1.0 (10 bar) rating ;150 mm dia suitable to fix with DI pipe conforming to IS:5312 all as specified and directed.
M & L DI pipe specials/fittings viz bends, tappers, reducer, Tee, angle / radius and straight connecting pieces and flanges etc. of any dia, any size and any type conforming to IS 9523.
M & L fabricate MS Pipe header of dia 250 made out with MS pipe including one outlet pipe of 250 mm and three inlet pipe of 150 mm as shown in drawing. Common header will be resting on brick pillar and rate is deemed to be included in quoted cost Approximate length of header 3.5 mtr.
Supply of Schematic diagram of plant details on a luminous Flourescent sheet as directed by Engr-in-charge.
Supply and fix wall mounted first aid box water proof metal box suitable to accommodate and including following medicine ( should be as per recommendation of medical authority guidelines and approved by GE ) and items all as specified and directed (a) Alcohol/nonalcoholic antiseptic wipes (b) Band aids (c) cotton balls (d) cotton swabs (e) tincher/iodine (f) bandages (g) gauze (h) hydrogen peroxide (i) pain killer/ paracetamol tablets
Supply of provision of fire stand of size (as per TD No. TD/2004/43 ) made out of MS angle iron/channel and painted with 2 coats of synthetic enamel P.O. red over a coat of red oxide primer and lettering with white paint and arrangement for keeping following items:- (a) bucket MS 9 ltr capacity for water and sand -06 Nos (b) fire extinguisher CO2 type 4.5 kg capacity-03 Nos (c) Fire extinguisher foam type – 03 Nos (d) Fire hook -01 No (e) Fire beater – 01 No (f) Axe-01 No (g) Shovel -01 No (h) Fire gong- 01 No Note: - All the items shall be ISI marked and conforming to makes.
Cutting of existing Di pipe line of 400 mm dia in position for insertion of bend to take pipe line to proposed new sedimentation tank as shown in drawing.
Cutting of existing Di pipe line of 400 mm dia in position for insertion of blank flange and connecting with 250 mm DI pipe line coming from filters to take pipe line to existing water reservoir near to existing pump house as shown in drawing.
Construction of valve pit chamber of size 2050x2050x2050 ( internal diamension ) including necessary excavation and earth work in any type of soil and MS sheet cover 6mm thick with 2 nos MS hinges and angle iron 40x40x6mm frame with lifting hook complete.
S & F Rubber Mat 2.0 mm thick (1m x 2m) tested for LT voltage 1100 volts complete all as specified and as directed by Engr-In-Charge.
Supply and fix cable tray of size 200 x 50 mm , 1.2 mm thick perforated type powder coated with coupler plates all as specified.
Supply, fix, erect, fabricate supporting structure for water pipe, cable tray inside plant room and out side plant room With angle iron, flats, MS pipe of suitable sizes, nut bolt washers etc Necessary welding work involved is also deemed to be included in quoted rate.
Supply, instal, test and commission out door step down transformer of capacity 315 KVA, 11KV/ 433V, 3 phase, 4 wire,50z with oil immersed naturally cooled delta connected on HV side and star connected on LV side in accordance with vector symbol Dyn-11 with neutral brought out on secondary side and having taping copper wound complete with first fill of oil with OFF load tapping on HT side to vary secondary voltage within limit of ±7 1/2 % in step of 2.5% by means of OFF load Tap changer. Maximum temp rise shall not exceed 45° Celesius on oil and 55 degree Celsius in HV/ LV windings when measurd by resistance method Transformer shall conform to IS- 1180 level 3. Transformer shall have min following item fitted on its body :- (a) 3 Nos porcelain bushing with arcing horn on HV side suitable for 11 KV with bushing, copper rod nut washers etc (b) One cable end box on LT side consisting of 4 Nos of porcelain bushing with copper rod complete with nut, washer and two Nos cable gland suitable for receiving / taking out of XLPE cable (c) Oil conservator with drain valve and oil level gauge (d) Dehydrating breather with first fill of dehydrating materia ( Copper sulphate) (e) Explosive vent (f) Thermometer pocket on tank cover (g) Dial type thermometer of 100 mm dia -1 No (h) Two earthing terminal on tank cover to facilitae fixing of 32x6 mm GI earth strip of neutral and body (j) Rating plate and terminal marking plate (k) Oil Level Gauge (l) Lifting Lugs (m) First Filling of oil (n) Foundation for transformer depending on its size plus 1.0 mtr space all around for walking and keeping tools in case of maintenance. Height of foundation shall be 1.0 mtr from ground level and it will have expanded metal fencing all around transformer with gate and locking arrangement.
Supply, instal, test and commission silent diesel engine driven generating set turbo charged of 250 KVA of 0.8 Power factor 415 Volts 3 phase 50 HZ, 4 wire and with accoustic weather proof enclosure as per CPCB norms and noise level shall not exceed 75 dB at a distance of 1 mtr fron steel enclosure complete in all respect and comprising of following:- (a) A diesel engine developing sufficient HP to run alternator to generate 250 KVA power at 0.8 PF at 1500 RPM conforming to IS 10002 complete with all accessories (b) Syncrnous alternator 200 KW 1500 RPM, 415 Volts, 50 HZ, 3 phase system brushless type screen protected self excited conforming to IS 4772 (c) AMF panel shall be of suitable size, factory made, indoor cubicle type both side openable fabricated from CRCA sheet of min 1.6 mm thick having busbar of 600 Amp capacity and to receive supply from Gen set and transformer panel as incoming and giving supply to panel which control supply to pump. Necessary controlling MCCB of 400 amps 36 KA ,04 Pole - 02 Nos rating shall be provided. Panel shall be grouted in floor y, CT & PT of suitable rating, battery charging unit, electric starter etc (d) accostic enclosure Enclosure shall be with natural ventilation, modular construction, shall be made of CRCA steel sheet of min 1.6 Mm thick (e) Fuel tank of suitable capacity fixed on suitable steel structure with inlet, outlet connection fuel level indicator (f) Base frame made out of suitable channel duly reinforced and privided with anti vibration pad and RCC/ PCC foundation as per manufacturer drawing and specification. Ht of foundation shall be min 30 CM from ground.
Supply , install, test and commission enegy efficient LED street light suitable for 1x 35/36 Watt IP 65 with 5 KA surge protector including fixing clamps on steel tubular pole and 1.5 Sq mm coper cable from junction box to light fitting
Supply and fix cable route indicator of size 100 x 100 x 5 mm thick made out of GI plate welded or bolted to 15 mm dia MS rod of 50 Cm long grouted in PCC foundationof size not less than 15 x 15 x 40 CM
Supply and fix pole mounted terminal box of size 300 x 200 x 105 MM ( inside dimensionof box) including MCB SP 6 Amp 2 Nos Aluminium bus bar of 25 x 3 MM size fixed on porceilain insulator with hinged covers and locking arrangement fixed to electric steel tubular pole by means of MS flat iron stripe of 25 x 3 mm size with nut bolts complete.
M&L for providing reflective thermoplastic paint 2mm thick any colour on black top surface including glass beads as specified
Supply MCBs, C-curve, ISI marked, 10 KA, integrated lable holder, sliding bottom clamp, improved air channels, color coded On/Off indication on dolly, biconnect lower terminals, IP 20 protected terminals, sliding shutter, IS-60898-12002 of the under mentioned type and rating and fixing in DBs (DBs Catered separately in this schedule) for SP 6-16 Amps complete. 'Note : Make of the MCB should be the same as that of DB
Supply MCBs, C-curve, ISI marked, 10 KA, integrated lable holder, sliding bottom clamp, improved air channels, color coded On/Off indication on dolly, biconnect lower terminals, IP 20 protected terminals, sliding shutter, IS-60898-12002 of the under mentioned type and rating and fixing in DBs (DBs Catered separately in this schedule) for SPN 25 Amps complete. 'Note : Make of the MCB should be the same as that of DB
Supply only ceiling fan 1200 mm sweep, suitable for SP 230/ 250 V 50 Hz AC supply with down rod and connecting up with 3 runs of 1.5 sqmm, single core PVC insulated but unsheathed, FRLS cable with multistranded copper conductors IS 694 marked, from ceiling rose to fan.
Supply only of exhaust fans of 350 mm sweep suitable for SP 230 / 250V 50 Hz AC supply, , protective bird guard is provided, robost construction complete including fixing/grouting of frame in wall and cutting opening complete and connecting with and including 3 nos 1.5 sq mm single core, PVC insulated but unsheathed FRLS cable with multistranded copper conductors from ceiling rose to fan.
S&F wall mounted LED batten fitting, 20W LED 6000K , with LED rod 1x18watt, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver complete including copper cable 23/.0076 for electric connection for fitting from ceiling rose all as specified and directed complete.
S&F 45 W LED security light fitting, 240 volts AC, 50 Hz of new generation energy saving & environmental friendly long life versatile pressure dia cast aluminium IP 66 roadway luminair with high power LEDs as light source and elctronic driver with 5 KA surge protector and PVC wired complete with all necessary fittings and fixed on wall with suitable dia bend shape GI pipe light grade of appx length 1.0 mtr with clamps nut & bolts etc. as directed and specified.
Supply, laying, fixing, testing and commissioning of MS pipe 168.3 mm outer dia pipe having thickness 4.5 mm as per IS 3589, in standard length suitable for flanged joint. The pipe shall be laid above ground in plant room and up to filters as shown in drawing. After activated carbon filter pipe line will be laid underground. Contractor should quote rate accordingly.
Supply, laying, fixing, testing and commissioning of MS pipe 219/13 mm outer dia pipe having thickness 6.3 mm as per IS 3589, in standard length suitable for flanged joint. The pipe shall be laid above ground in plant room and up to filters as shown in drawing. After activated carbon filter pipe line will be laid underground. Contractor should quote rate accordingly.
Butter fly valves (Manual) with CI body of 200 mm dia, stainless steel disc,nitrile rubber seal & O ring, suitable for PN 1.0 (10 Bar) rating for fixing to 200 mm pipe complete all as specified.
S & F MS Flanged welded TEE 400 x 400 x 400 mm.
Outsourcing of services for operation & regular maintenance of installations for filtration plant in three shift of 8 hours each (each shift shall have 01 ITI Qualified person and 01 Helper) for 24 hours continous operation including sundays and holidays in a day to day maint condition as specified, including the following maintenance :- (1) Daily and weekly check up (2) Monthly, quarterly and half yearly maintenance as per maintenance schedule (3) To info concerned incharge if any abnormal activity during running is being observed (i) Greasing of motor bearings (ii) Gasket, schellacs, rubber (4) To maintain the log sheet of pump House, Pump & DG Set include logsheet Arrangement of labour and tools for smooth functioning of plants, all as specified and directed by Enginner-in-Charge. Note :- The contractor while quoting rate shall take into account for EPF, ESIC, Bonus, Overhead Profit, LWC and GST to be paid at applicable rates alongwith payment of minimum wages to the personnel employed at worksite into this item only. Contractor shall ascertain & consider above mentioned contributions while quoting & nothing extra shall be admissible to the contractor on this account.
S AND A ENGINEERS CONSTRUCTION CO
RYSA INFRATECH
Raja enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .