| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 CrAccepted-AOC | ₹4.2 Cr Quoted ₹3.6 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹3.6 Cr+₹5.1 L (1.42%)Rejected-AOC | ₹3.6 Cr+₹5.1 L (1.42%) | L2 | Rejected-AOC L2 |
| 3 | L3₹3.7 Cr+₹10.0 L (2.79%)Rejected-AOC | ₹3.7 Cr+₹10.0 L (2.79%) | L3 | Rejected-AOC L3 |
Tender Value
Refer Docs
EMD Value
₹4.3 L
Closing Date
31 Oct 2024, 4:00 pmClosed
Ex.Eng.Mech.Ref
Municipal Workshop, 103, R.S.Nimkar Road, Byculla (W), Mumbai
Replacement of AHUs at NICU second floor E wing , PICU second floor F wing and Casualty area upper ground floor F wing along with allied works at Dr. R N Cooper Hospital Vile Parle (W)
2024_MCGM_1111837_1
Dy.Ch.Eng/Mand E/ 1778/CIty
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
Dr. R N Cooper Hospital Vile Parle (W)
Please refer Tender documents.
3 documents required · 3 mandatory
₹19,470
₹4.3 L
Dy.CH.Eng (M and E) City office
4 Feb 2025
11 Oct 2024
4 Nov 2024
11 Oct 2024
31 Oct 2024
11 Oct 2024
18 Oct 2024
Amount
SITC of floor mounted chilled water double skin air handling unit of 16000 - 18000 CFM 6Rows
SITC of floor mounted chilled water double skin air handling unit of 3000 - 4000 CFM 8Rows
SITC of floor mounted chilled water double skin air handling unit of 7000 - 8000 CFM 8Rows
SITC of GI. Sheet metal ducting of 20 SWG
SITC of GI. Sheet metal ducting of 22 SWG
SITC of GI. Sheet metal ducting of 24 SWG
S & I of M.S. 'C' water pipe line of 200 mm diameter with insulation of 38 mm thk nitrile rubber
S & I of M.S. 'C' water pipe line of 150 mm diameter with insulation of 38mm thk nitrile rubber insulation
S & I of M.S. 'C' water pipe line of 125 mm diameter with insulation of 38 mm thk nitrile rubber insulation
S & I of M.S. 'C' water pipe line of 100 mm diameter with insulation of 38 mm thk nitrile rubber insulation
S & I of M.S. 'C' water pipe line of 75 mm diameter with insulation of 19 mm thk nitrile rubber insulation
S & I of M.S. 'C' water pipe line of 65 mm diameter with insulation of 19 mm thk nitrile rubber insulation
S & I of M.S. 'C' water pipe line of 50 mm diameter with insulation of 19 mm thk nitrile rubber insulation
Butterfly valves – 200 mm diameter
Butterfly valves – 150 mm diameter
Butterfly valves -125 mm diameter
Butterfly valves – 100 mm diameter
Butterfly valve 75 mm diameter
Butterfly valve 65 mm diameter
Ball valves 25 mm diameter
Auto air vents- 15 mm diameter
P & F of 2- way mixing valve of 65 mm diameter
Replacement of existing damaged false ceiling sheet by new false ceiling of medium density fiber board.
Supply and installation of volume control dampers, bypass dampers.
Providing fresh air damper with crowl piece,bird screen and removable type prefilters
Providing aluminium supply air diffusers & return air grills with volume control dampers
Replacement of existing damaged relief dampers by providing new gravity operate relief dampers with screen consisting of G.I. frame, aluminium louvers & G.I. wire mesh.
Providing thermal insulation to supply air ducting with 19 mm thickness nitrile rubber
Providing thermal insulation to return air ducting with 12mm.thickness nitrile rubber
Supply & fixing acoustic insulation in the Plant room/ AHU room
Replacement of existing damaged acuostic insulation in the plant room with new acoustic insulation
To provide the screen arrangement to return air opening in the Plant room/ AHU rooms
Providing acoustic lining to the initial portion of supply air duct from inside of the ducting using fiber glass crown 300*25mm thick rigid board or equivalent insulation material covered with 24 gauge perforated aluminium foil.
S &F of diaphragm type pressure gauges with necessary fitting and gate valve on chiller water inlet and outlet lines
Providing Digital temperature indicator with thermowell and senser on chiller water pipe line inlet, outlet and for return air
Providing & fixing of Canvas Connections for units.
S & I of 50 mm thick both side PPGI sheet with PUF insulation
S & I of 80 mm PPGI sheet Panel along with accessories
S & I of Cubical panel for chilled water AHU
MS structure for AC works
FRP Coating for MS Structure
To make opening in the walls
Dismantling old Air Handling Unit and its accessories
Cu armoured cables FRLS outer sheathed- 3C x 1.5 Sq.mm
Cu armoured cables FRLS outer sheathed- 4C x 2.5 Sq.mm
Cu armoured cables FRLS outer sheathed- 4C x 6 Sq.mm
Cu armoured cables FRLS outer sheathed- 4C x 4 Sq.mm
Cable End Termination For Copper Cables – 3C x 1.5 Sq.mm
Cable End Termination For Copper Cables – 4C x 2.5 Sq.mm
Cable End Termination For Copper Cables – 4C x 6 Sq.mm
Cable End Termination For Copper Cables – 4C x 4 Sq.mm
1x28W, T-5 Fixtures, comprises of M.S.Powder coated with end cap. The fixtures complete with high efficiency electronic ballast and PF= 0.98 complete with bright reflector & T-5 lamp
Indoor light fixtures -LED Square Recessed Downlighter-36W (600x600)
63 Amp. TPN MCB
Light /Fan / Ex. fan Points
2/3 Pin Independent Plug (IP)
15 / 5 A / 6 A Combined Power Plug Socket Point with Fuse and Indicating Lamp, One 15 Amp SP Switch
Earthing Continuity Conductors -Bare G.I. Conductor of 8 SWG
Removal of point wiring (Light ,fan points,IP,PP,call bell,gong bell,bell indicator points)
Removal of fixtures / fittings / ceiling fans / bulkhead / street light / gyeser etc.
Removal of old cameras, DVRs along with cables and accessories
Refixing of old cameras, DVRs along with cables and accessories
Removing/ Dismantling of old 3.0 TR window/ split AC/ FCU/Cassette unit.
SITC of Gear operated Butterfly valve 350 mm
S & I of M.S. 'C' water pipe line of 300 mm diameter with insulation of 38 mm thk nitrile rubber
Rebate for old AHU & its accessories CFM 2000 - CFM 7000
Rebate for Point wiring in copper conductor.
Rebate for All types of tube light fittings / fixtures with down suspension rods ball socket etc
Rebate for old 3.0 TR FCU/Cassette unit.
EMPAS ENGINEERING (BID ID -6343061)
SAI COOL SERVICES (BID ID -6344320)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .