Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.2 LAccepted-AOC BENAGERIA JHARGRAM WEST BENGAL 721507 | JHARGRAM | JHARGRAM | WEST BENGAL | 721507 | ₹47.2 L | L1 | Accepted-AOC As per Technical and Financial Evaluation. |
| 2 | L2₹47.8 LRejected-Finance A C 151 SONARPUR UTTAR RAJPUR SONARPUR MUNICIPALITY WEST BENGAL WB | PURULIA | WEST BENGAL | 723101 | ₹47.8 L | L2 | Rejected-Finance L2, Financially disqualified |
| 3 | L3₹48.1 LRejected-Finance | ₹48.1 L | L3 | Rejected-Finance L3, Financially disqualified |
| 4 | L4₹48.5 LRejected-Finance 138 PURBA PALLY KOLKATA 700078 | KOLKATA | KOLKATA | WEST BENGAL | 700078 | ₹48.5 L | L4 | Rejected-Finance L4, Financially disqualified |
| Sl No | Description | Qty | Unit | Bharat Construction L4 | M/S DIPANWITA MAITY L3 | Professional Construction L1 | BINAPANI ENTERPRISE L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | TOTAL QUOTED AMOUNT | 1 | LS | 48,54,128 ₹48.5 L | 48,14,885 ₹48.1 L | 47,24,520 ₹47.2 L | 47,84,451 ₹47.8 L |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
27 Jan 2026, 4:00 pmClosed
Superintending Engineer
DG Block, Sector- II, Salt Lake City, Kolkata-700091
Construction of Swimming pool with Pump Room at Jhargram Rajbari Tourism Project.
2026_WBTDC_985467_1
NIT No.104/WBTDCL OF 2025-26 (Technical)
Open Tender
CIVIL AND ELECTRICAL WORKS
180 days
Jhargram Rajbari Tourism Project
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹1 L
27 Apr 2026
8 Jan 2026
29 Jan 2026
8 Jan 2026
27 Jan 2026
8 Jan 2026
TOTAL QUOTED AMOUNT
Item Rate BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Filtaration System
Supply and fixing of 2HP Centrifugal Monoblock pump Make-KSB, AGRIBLOC 20-5050
Swimming Pool Sand Filter 900 Dia MM Fiberglass Top Mounted Sand Filter 36 inch with Top Mounted Multiport Valve (2.0 inch Valve) for Filtration Upto 30000 Litre/hr
1.5 lbs Pool Filter Balls Eco-Friendly Fiber Filter Media for Swimming Pool Sand Filters (Equals 50 lbs Pool Filter Sand)
Circular ABS Swimming Pool Round Drain for Concrete Pool with 170mm in Diameter & 2 inch Internal Thread Connection, Underwater Round Strong & Durable Floor Drain Rapid Outflow System
Single Phase 220V 2 HP Openwell Submersible Pump with Cable and Starter For Lifting Water from Wells,Tanks (LXOP-2 HP)
SS304 Drain Flat Running (Swimming Pool) - Stainless Steel 304, Brushed Finish, 900mm (36”) in Length and 175mm (7") in Width,Swimming Pool Drain System
Nonthreaded Swimming Pool Wall Inlet Fitting for Concrete Pool with External 60mm and Internal Diameter 50mm
ueWave Vacuum Head 18 ch Aluminium Body eighted Swimming Pool vacuum Head on wheels, section head, Flexible Pool Spa Tiles surface Cleaning equipment Tool
Swimming Pool Ladder for In Ground Pools Heavy Duty Stainless Steel Pool Step Ladder with Easy Mount Legs Stainless Steel 304, 2 Steps
WATERTECH SYSTEMS Swimming Pool Ladder for In Ground Pools Heavy Duty Stainless Steel Pool Step Ladder with Easy Mount Legs Stainless Steel 304, 3 Step
Outdoor Swimming Poolside Lounger Beach Sunbathing Lawn Patio Chaise Lounge Sun Lounger Chair Adjustable Backrest (Dark Brown + Brown)
THESHELTERS - 15ft Large Outdoor Umbrella Double-Sided Patio Umbrella with Base, Crank Handle, 12 Ribs Rectangular Garden Umbrella for Patio Graden, Poolside, Terrace, Cafe and Hotels
Electrical
Supply of XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make - Gloster/ Polycab / KEI/Havells/ as per choice of EIC]. a) 3.5 core 35sqmm
Supply of Round/square 7W LED Panel Downlighter 3000k, aluminum material, Longer life of 50k hrs, Surge protection of 2.5 KV with wide voltage protection 160-360V, 735lm/3000K, No visible flickering, no UV/IR and low glare to prevent eye strain, Even and comfortable light perfected for your eye comfort. [Make: Philips or equiv make as per choice of EIC.]
Supply of LED Mirror / Picture Light 3000K, 7W bronze colour aluminum material, Flexible neck for adjusting beam, as required, 450lm/3000K. [Make: Philips (Poise) / Bajaj/Havells/ equiv make as per choice of EIC.]
Supply of LED Battene light of size 2 ft, 22W, 3000K as per direction of EIC. Model- Philips BN021 LED22S 6500K/4000K PSU GR /Havells/Crompton or equivalent as per direction of EIC.
Supply of LED Battene light of size 4 ft, 36W, 3000K as per direction of EIC. Model- Philips BN021 LED40S 6500/ 4000 PSU GR /Havells/Crompton or equivalent as per direction of EIC.
Supply of Weather Proof In ground light suitable for pool side, IP67, 3W LED, 3000K as per direction of EIC. Model- Philips IP67 LED Inground Light 3W /Havells/Crompton or equivalent as per direction of EIC.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (Make: as per choice of EIC)
Supply of 400 mm sweep 3 blade non decorative Wall fan, Pull cord control for speed and oscillation On-Off, High speed motor for higher air delivery, Thermal Overload Protection. [Make: Havells (Swing off-white) / Usha/ Crompton / equivalent make as per choice of EIC.]
Supply of Exhaust fan 150mm sweep non-metallic 1350RPM as required. [Make: Havells (Ventil Air DXZ White) /Crompton/ Usha/ equivalent make as per choice of EIC.]
Supply and delivery of 15 Ltr Capacity Geyser, Vertical / Horizontal Storage, Wattage: 2000 Watts; Pressure: 8 Bars ; Waterproof Degree : IPX-4 Protection for longer product life, Thermal Overload Protection, Adjustable knob for temperature settings between 25 degree C to 75 degree C to get the desired temperature with all necessary anciliary. [Make: Havells (Troica) / Bajaj / Jaquar or equivalent as per EIC choice.]
Percentage BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
EARTH WORK
Earth work in excavation of foundation trenches all sorts of soil (including mixed soil but excluding laterite or sand stone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed.The Iteam includes necessary triming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.
Depth of excavation not exceeding 1500mm
b) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring.
Earth work in filling in foundation trenches or plinth with good earth, in layer not exceeding 150 mm. including watering and ramming etc. Layer by layer complete. ( payment to be made on the basis of measurement of finished quantity of work ) (a) With earth obtained from excavation of foundation
BRICK FLAT SOLING
Single brick flat soling of picked jhamma bricks including ramming and dressing bed to proper level and filling joints wth local sand
P.C.C.WORK
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. a) Pakur Variety
REINFORCEMENT
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction .(a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel I. SAIL/ TATA/RINL
SHUTTERING
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
CONCRETEING M-25
Controlled Cement concrete with well graded stone chips (20 mm graded nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation. [using concrete mixture] M 25 Grade (i) Pakur Variety
BRICK WORK
PLASTERING WORK
Plaster ( to wall,floor,ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary.(Ground floor) [excluding cost of chipping over concrete surface]
With 1:6 cement morter
20mm thick plaster
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. Note: Cement 0.152 cu.m per 100 sq.m.
ROOF TREATMENT
(b) Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer's specification for water proofing layer in water tank etc. (No Departmental Cement is required)
FLOORING
Supplying, fitting & fixing Glass mosaic tiles at finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design, fixing in customize design as per direction of Engineerin- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge. [At Ground Floor]. ii) Gradation/ Progression Type
Deck Pool
EARTH WORK
Earth work in excavation of foundation trenches all sorts of soil (including mixed soil but excluding laterite or sand stone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed.The Iteam includes necessary triming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.
Depth of excavation not exceeding 1500mm
(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) (B) Do - by fine sand
BRICK FLAT SOLING
Single brick flat soling of picked jhamma bricks including ramming and dressing bed to proper level and filling joints wth local sand
P.C.C.WORK
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. a) Pakur Variety
SHUTTERING
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
Supplying& laying 20 mm designer chequered tiles of any shade and of approved quality as per IS: 1237: 1980 laid in patterns as directed in pavement, footpath including necessary underlay 25 mm thick average cement mortar (1:3) complete in all respect with all labour and materials [using cement slurry @ 4.4 kg/Sq.m at back side of tiles. Cement of mortar & slurry will be supplied by the Department. Border concrete if necessary to be paid separately].
Pump Room
EARTH WORK
Earth work in excavation of foundation trenches all sorts of soil (including mixed soil but excluding laterite or sand stone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed.The Iteam includes necessary triming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.
Depth of excavation not exceeding 1500mm
b) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring.
Earth work in filling in foundation trenches or plinth with good earth, in layer not exceeding 150 mm. including watering and ramming etc. Layer by layer complete. ( payment to be made on the basis of measurement of finished quantity of work ) (a) With earth obtained from excavation of foundation
(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) (B) Do - by fine sand
BRICK FLAT SOLING
Single brick flat soling of picked jhamma bricks including ramming and dressing bed to proper level and filling joints wth local sand
P.C.C.WORK
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. a) Pakur Variety
REINFORCEMENT
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction .(a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel I. SAIL/ TATA/RINL
SHUTTERING
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
CONCRETEING M-25
Controlled Cement concrete with well graded stone chips (20 mm graded nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation. [using concrete mixture] M 25 Grade (i) Pakur Variety
BRICK WORK
Brick work with 1st class brick in cement morter (1:6)
In foundation and plinth
In superstructure, ground floor
PLASTERING WORK
Plaster ( to wall,floor,ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary.(Ground floor) [excluding cost of chipping over concrete surface]
With 1:6 cement morter
20mm thick plaster
15mm thick plaster
With 1:4 cement morter
10mm thick plaster
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. Note: Cement 0.152 cu.m per 100 sq.m.
Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G . of approved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete.
PAINT INTERIOR
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor)
(a) One Coat i) Water based interior grade Acrylic Primer
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats)
ii) Luxury Quality
PAINT EXTERIOR
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC.
In ground floor:-
One coat
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.
In Ground floor (Two Coat)
Premium 100% Acrylic Emulsion
Sanitary & Plumbing Work
Suppling and fitting and fixing Wall mounted water closet of glazed vitreous chinaware of approved make and brand in position complete with necessary nut and boalts (Equivalent to code no.20061 or 92065 &Model studio or Rubbic of Hindware or equivalent)( This item to be executed on specific permission of superintending Engineer)
Suppling and fitting and fixing Concealed Cistern of approved make with flash plate cute/Loop/shell/nova/(Code No. concealo-H(80mm Body sap code 808179 of Hindware or equivalent, matt / gloss)
Suppling and fitting and fixing wash basin vitreous china of approved make (with fittings ) supplied ,fitted and fixing in position on 75mm X 75mm X 75 mm wood block and C. I brackets including 2 coat of paint of C I Brackets (iii) 630 X 450 mm Size
Supplying, fitting and fixing pillar cock of approved make c) CP Pillar Cock - 15 mm. (Code No. 5011 & Model - FLORENTINE of JAQUAR or equivalent).
Supplying fitting & fixing waste fittings complete.(ii) 32mm C. P. Over Brass
Supplying fitting & fixing complete Bottel waste Trap (heavy quality) (a) Chromium plated Bottle trap 32mm with 190mm long connecting pipe and wall flange (equivalent to Code No. 545 & Model - Tropical/ Sumthing Special of ESSCO or similar brand)
Providing & fixing in position Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or simila
Supplying, fitting and fixing liquid soap container. (a) Cromium plated.
Supplying, fitting and fixing soap holder. (a) PTMT (Prayag or equivalent)
Providing & fixing of Hand Shower (Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar).
Supplying, fitting and fixing towel rail with two brackets.(a) C.P. over brass (ii) 25 mm dia. and 600 mm long
Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete.(i) 635 mm X 395 mm X 420 mm
Supplying, fitting and fixing pillar cock of approved make. CP Wall Mixture without spout but with provision for connnection to Telephone Shower and exposed pipe for Overhead shower (Equivalent to Code No. 5215 & Model - FLORENTINE of JAQUAR or similar brand).
Supplying, fitting and fixing shower of approved brand and make. Chromium plated Hand shower with Flexible Tube & fittings(Equivalent to Code No. Hsh-1937 & (Equivalent to Code No. 5037 & Model - Florentine of Jaquar or similar).).
Supplying, fitting and fixing shower of approved brand and make. Chromium plated round shower with revolving joint 100 mm dia with rubid cleaning system (Equivalent to Code No. 542(N) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
Supplying, fitting and fixing shower of approved brand and make. (iii) Chromium plated shower arm 240 mm long (Equivalent to Code No. 536(A) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm
Supplying, fitting and fixing C.I. round grating.(100mm)
Supplying, fitting and fixing C.I. holder bat clamp including cutting holes in wall etc. and mending good all damages in cement concrete with jhama chips (4:2:1) and cement plaster (6:1) to match and curing complete in all respect.
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. (a) For Exposed Work (i) CPVC Pipes Class-1, SDR-11
15 mm dia (for concealed work)
20 mm dia (for concealed work)
50mm dia (For exposed work )
Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD -1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross,elbo, nipple, longscrew,reducing socket, reducing tee, short piece etc.fitted including cost of all materials, jointing materials,cutting pipes,making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.) PVC pipe(dia)
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)
For Exposed Work PVC Pipes 100 mm
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992
Li) Nahani Trap 90 mm
Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007 (Q) Ball Valve
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials.
i) With Pakur variety. (SAIL/TATA/RINL)
Electrical
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : For 3½ core upto 35 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 3½ core 35 sqmm cable
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Legrand) 4 way
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Legrand) a) 2+8 way
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Legrand) a) 63 A FP
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required a) 3 x 22/0.3 (1.5 sqmm)
b) 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC
c) 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles 19 mm dia 3 mm thick polythene pipe without earth continuity wire
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed] a)Average run 5 mtr
b)Average run 8 mtr
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC On Board
Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket with 20/25A Modular switch (Brand approved by EIC) type SP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling by screws etc.
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: 23 cm (9")
Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) For Al 23 cm Exhaust fan (9")
Fixing only starters (for motor control) on flat iron frame / angle iron frame on wall On angle iron frame Direct on Line starter for motor (upto 5 HP)
Excavation of soil for installation of Earth Electrode and filling & ramming.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
Extra for treatment of soil by using salt & charcoal or coke for plate electrode
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages Solid GI wire No. 8 SWG
Sub Total
Add GST @18% .
Sub Total
Add labour welfare Cass @ 1%
INR Forty Lakh Four Thousand Three Hundred & Eighty Eight Only
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.89 MB
BOQ_2405254.xls
BOQ • 0.44 MB
2911.pdf
Tender Documents • 0.50 MB
Download all tender documents and submit your bid