Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-01₹9.2 LAccepted-AOC | L-01 | Accepted-AOC Being lowest | |
| 2 | L-02₹9.9 L+₹16,286.50 (1.67%)Rejected-Finance | L-02 | Rejected-Finance Not being lowest | |
| 3 | L-03₹10.3 L+₹52,329.50 (5.36%)Rejected-Finance | L-03 | Rejected-Finance Not being lowest | |
| 4 | L-04₹10.3 L+₹56,480 (5.78%)Rejected-Finance OPPOSITE GHOOM DRC PO GHOOM DISTT DARJEELING WB PIN 734 102 | DARJEELING | WEST BENGAL | 734102 | L-04 | Rejected-Finance Not being lowest | |
| 5 | L-05₹10.5 L+₹69,551.50 (7.12%)Rejected-Finance | L-05 | Rejected-Finance Not being lowest |
Tender Value
₹9.2 L
EMD Value
₹18,400
Closing Date
10 Nov 2022, 6:00 pmClosed
AGE (I) Darjeeling
P.O. Jalapahar Dist- Darjeeling (WB) Pin- 734103
REPAIR REPLACEMENT OF WATER SUPPLY DISTRIBUTION MAINS AND GI PIPE LINE AT JALAPAHAR UNDER AGE I DARJEELING
2022_MES_557483_1
8956/E8
Open Tender
Civil Works
Item Rate
182 days
AGE (I) Darjeeling
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
AGE (I) Darjeeling
₹18,400
Yes
3 Dec 2022
13 Oct 2022
12 Nov 2022
13 Oct 2022
10 Nov 2022
28 Oct 2022
13 Oct 2022 - 20 Oct 2022
Amount
Excavation in Trenches, not exc. 1.50 Metre wide and not exc 1.50 Metre in depth for any type of foundation/cable trench and getting out in Soft/Loose Soil, complete all as specified and as directed.
Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 25 Cm in Soft/Loose Soil, complete all as specified and as directed.
Removing excavated Materials (Soils) not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point in Soil, complete all as specified and as directed.
Demolition of Brick Work/ Stone masonary built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any description, complete all as specified and as directed.
Taking down / out old unserviceable GI tubing upto 20mm bore (dia) including all fittings and fixture from floor/wall or trenches including cleaning and stacking for refixing / reuse and removal unusable materals from site of work complete all as directed.
All as per ser item No 05 above but 25 mm bore of pipe complete all as specified and as directed.
All as per ser item No 05 above but 40 mm bore of pipe complete all as specified and as directed.
All as per ser item No 05 above but 50 mm bore of pipe complete all as specified and as directed.
All as per ser item No 05 above but 80 mm bore of pipe complete all as specified and as directed.
S&F 20mm bore (dia) GI tubing 'medium grade' galvanised with all fittings laid in trenches, complete all as specified and as directed.
All as per ser item No 10 above but 25 mm bore of pipe complete all as specified and as directed.
All as per ser item No 10 above but 40 mm bore of pipe complete all as specified and as directed.
All as per ser item No 10 above but 50 mm bore of pipe complete all as specified and as directed.
All as per ser item No 10 above but 80 mm bore of pipe complete all as specified and as directed.
S&F 20mm bore (dia) GI tubing 'medium grade' galvanised with all fittings fixed to wall, ceiling or laid in floor, complete all as specified and as directed.
All as per ser item No 15 above but 25 mm bore of pipe complete all as specified and as directed.
All as per ser item No 15 above but 40 mm bore of pipe complete all as specified and as directed.
All as per ser item No 15 above but 50 mm bore of pipe complete all as specified and as directed.
All as per ser item No 15 above but 80 mm bore of pipe complete all as specified and as directed.
S&F in-repair of GI Flange of size 80mmm bore,threaded type, ISI marked, with and including nut-bolt, washer, gasket, etc., complete all as specified and as directed.
S&F of 25mm bore (dia), gun metal gate valves with iron wheel head,screwed both ends for iron pipe, ISI Marked, as per IS: 778 and including taking out old unserviceable gate valves complete all as specified and as directed.
All as per ser item No 21 above but 40 mm bore of pipe complete all as specified and as directed.
All as per ser item No 21 above but 50 mm bore of pipe complete all as specified and as directed.
M&L Brick Work with Fly Ash Bricks, Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed.
Supply & Fixing , jointing and testing of cast iron sluice Valve ISI mark (PN-1.6) of size 80 mm bore confirming to IS 14846-2000, flanged ends drilled having brass spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets including taking out old unserviceable sluice valves, complete all as specified and as directed.
Supply & fixing Cast Iron Air Release Valves (ARV) with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Cast Iron Water supply mains of size 50 mm dia including taking out old unserviceable CI ARV all as specified and as directed.
M&L for Hardcore with broken stones/ boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and as directed.
M&L for Rendering (Externally) 15mm thick in Cement Mortar 1:4 on Brick Walls or on Concrete Surfaces, plastered surfaces finished Even and Fair, complete all as specified and as directed.
M&L for preparing newly plastered surfaces of Walls and applying Three Coats of White Wash, complete all as specified and as directed.
M&L Cutting existing GI water tubing of size 40 or 50 mm bore for alternations or addition including screwing/threading and jointing with suitable size GI socket complete all as specified and as directed by the Engineer-in-Charge.
Collecting the sample of water from Jalapahar pump house and testing of water for iron, PH value, TDS, colour, Total Alkalinity, Total Hardness, trubidity, chloride,Chlorine, fluoride, Nitrate, Copper, Total Coliform, Faecal Coliform, arsinic test and submitting the test report from reputed laboratory as directed by Engineer-in-Charge. Note : Testing shall be carried out quarterly as directed by Engineer-in-Charge.
Dismantling of defective / unserviceable 75HP pump set of Make- Kirloskar (Model- RKB 50/15L, 11 ST), segregating serviceable and unserviceable parts, cleaning/washing of serviceable parts, checking functional accuracy, clearance, wear & tear using different measuring equipments and by approved method, replacement of unserviceable parts, reassembling the pump set including painting of pump, motor and base frame with synthetic enamel paint complete all as specified and directed. Note : (i) Costing of necessary nuts, bolts, washers, gaskets, lubricating materials and other consumable materials are included in the quoted rate. (ii) Spare parts as required required to be replaced will be measured and paid under relevant item here-in-after.
Demolition of Cement Concrete (un-reinforced) of any description in Ground Floors, Pavings, etc. not exc. 150mm thickness (above or below Ground Level), complete all as specified and as directed.
M&L Cement Concrete 1:3:6, type C-2 (40mm graded aggregate) in Foundations, Filling and Mass Concrete, staging of MS/PVC storage tanks, repairs to pathways etc. including use and waste of Formwork as required/ordered at Site(s), complete all as specified and as directed.
S&F in-repair of Rotational Moulded Polyethylene Water Storage Tank 5000 Litre capacity (Cylindrical Vertical with Closed Top), 3 layered, hoisted and fixed in position with and including 20 mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 142gm), all as specified in MES Schedule Part-I, complete all as specified and as directed.
Supply only Calcium based granular disinfectant for water treatment, more stable than Chlorine Gas and Stronger than bleaching powder (Calcium Hypochlorite), with following specifications: Chemical Name- Calcium Hypochlorite. Common Name- Stable Bleaching Powder/ High strength Bleaching Powder. Appearance- Dry free flowing and free from lumps. Toxic & Undesirable Substance- Should not induce substances beyond acceptable limit as given in IS: 10500 (2012) in treated and disinfected water. Packing- 20-25 Kg Bags/ 40-45 Kg Drums. Packing in drums is preferable to reduce fire hazard in places of high ambient temperature. Available Chlorine- 65% by mass (min). Stability- 1/15 Loss of Chloride on basis of available chloride (max). Particle size (Passing through 1.70mm IS Sieve)- 99.50% by mass (min). Water insoluble matter- 6% (max). Calcium Hydroxide- 4% (max). Sodium Chloride- 15% (max).
S&F in-repair of Fully Automatic Star-Delta Motor Starters with Sheet-Steel Enclosure, 415V, 50Hz, 3-Ph, AC, suitable for 75 HP pump set, complete all as specified and directed. Make- L&T/ CG/ LEGRAND/ HAVELLS
M&L for repairing of leakage pipe line after disconnecting near by joint, including cutting existing GI water tubing of any size and any description for alterations or addition including screwing/threading, jointing and replacing with suitable size GI short piece and fittings as required at site, complete all as specified and as directed by the Engineer-in-Charge. Note: Rate of required fitting/short pieces will be included in Unit Quoted Rate.
Supply only impeller for multi stage centrifugal pump set of make Kirloskar of capacity Pump for 75 HP complete all as specified and as directed.
Supply only Gun Metal bush for impeller 75HP Centrifugal Pump Set complete all as specified and as directed.
Supply DE bearing No NU308 part No 24000 suitable for 75HP complete all as specified and as directed.
Supply only NDE bearing No 7308 part No 24001 suitable for pump 75HP of Make Kirloskar complete all as specified and as directed.
Supply only Roller bearing DE bearing No 26400 suitable for pump 75HP of Make Kirloskar complete all as specified and as directed.
Supply only stage casing bush part No 12400 suitable for pump 75HP of Make Kirloskar Pump complete all as specified and as directed.
Supply only shaft sleeve suction side/delivery side part No 31000 suitable for pump 75HP of Make Kirloskar complete all as specified and as directed.
Supply only oil seal (DE & NDE) part No 50000 suitable for pump 75HP of Make Kirloskar complete all as specified and as directed.
Supply only 'O' ring for shaft sleeve part No 52200 suitable for pump 75HP of Make Kirloskar complete all as specified and as directed.
Supply only gland packing and grease for pump complete all as specified and as directed.
Taking down/out defective / unserviceable centrifugal multistage Pump set of capacity 75HP from base frame by unscrewing nuts and bolts, disconnecting all electric connections and pipe lines etc.,shifting pump and motor outside building carefully transporting to Siliguri workshop for necessary repair/overhauling work and transporting back to pump house including reinstallation and testing after connecting all electrical and pipe lines complete all as specified and directed.
RAI CONSTRUCTION
Darjeeling Enterprises
Damdoo Bhutia
BIMAL BHATTRAI
KWOK YING CHIU
JALAPAHAR HARDWARE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .