Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.7 LAccepted-AOC | ₹47.7 L Quoted ₹48.8 L | L1 | Accepted-AOC OK |
| 2 | L2₹48.9 L+₹12,725 (0.26%)Rejected-Finance WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | ₹48.9 L+₹12,725 (0.26%) | L2 | Rejected-Finance Other than lowest tenderer |
| 3 | L3₹49.3 L+₹53,350 (1.09%)Rejected-Finance 131 SHINGANAPUR ROAD KOLKI KOLKI SATARA MAHARASHTRA 415523 | SATARA | MAHARASHTRA | 415523 | ₹49.3 L+₹53,350 (1.09%) | L3 | Rejected-Finance Other than lowest tenderer |
| 4 | L4₹49.7 L+₹91,240 (1.87%)Rejected-Finance 1ST FLOOR H NO 165 GALI NO 16 S B S COLONY KARAWAL NAGAR DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | ₹49.7 L+₹91,240 (1.87%) | L4 | Rejected-Finance Other than lowest tenderer |
| 5 | L5₹50.3 L+₹1.5 L (3.02%)Rejected-Finance | ₹50.3 L+₹1.5 L (3.02%) | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹95,800
Closing Date
19 May 2021, 6:00 pmClosed
GE E/M BASE HOSPITAL DLEHI CANTT
GE E/M BASE HOSPITAL DELHI CANTT-110010
PROVN OF DISTRIBUTION TRANSFORMER (315 KVA) RMU STAND BY DG SET 160 KVA HT/ LT CABLES LT PANELS AND MISC CONNECTED ITEMS AT BLDG NO T-14 P-113 (PSYCHIATRY WARD) FOR ACUTE CARE COVID-19 ISOLATION WARDS AT BASE HOSP UNDER GE (E/M) BHDC
2021_MES_440207_1
GE/BH-09/2021-22
Limited
Electrical and Maintenance Works
Item Rate
30 days
GE E/M BASE HOSPITAL DELH CANTT
Class D Category b(ii)
6 documents required · 6 mandatory
₹500
GE E/M BASE HOSPITAL DELHI CANTT
₹95,800
Yes
27 May 2021
5 May 2021
21 May 2021
5 May 2021
19 May 2021
13 May 2021
Amount
Excavation in trenches not exc 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying/ taking up/ taking down of cables and getting out and levelling of bottom surface to required level all as specified and directed.
Returning filling in,. including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material (i.e. soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified.
S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as directed by Engr-in-Charge.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade 95 Sqmm, 3 Core complete all as specified.
Supply, laying and testing cable XLPE insulated screened, PVC bedded galvanised steel strip or wire moured, electric power cable heavy duty with standard aluminium conductor 1100 Volt grade of size 3.5 Core, 300 Sqmm complete all as specified.
Supply, laying and testing cable XLPE insulated screened, PVC bedded galvanised steel strip or wire moured, electric power cable heavy duty with standard aluminium conductor 1100 Volt grade of size 400 Sqmm Single core complete all as specified.
Supply and fix cable jointing kit for 11 KV grade cable for in door termination, heat shrink type, joint complete with jointing material and accessories suitable for3 core XLPE, armoured, Al conductor cable of size 95 sqmm complete all as specified. Note: The jointing material like long sleeve for RMU connection and other connected items will inclusive in above rate.
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 sqmm complete all as specified. Note: The jointing material like long sleeve for RMU connection and other connected items will inclusive in above rate.
Supply and fix cable jointing kit for 11 KV grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 50 Sqmm to 95 sqmm, Indoor/Outdoor type complete all as specified.
Material & labour for GI steel tubing 80 mm bore light grade for protection of cable/ earth continuity conductor fixed to poles/ walls/ roof or laid in floors, road, crossing or ducts fixed with clamps , bolts nuts and washer etc complete all as specified and directed.
M&L Earthing complete with galvanised Iron earth plate electrode 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25mtrdeep below GL) with top edge of the plate not less than 1.5 metre below normal ground level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate with using 32X6 mm GI earth strip electrode welded and revetted to earth plate up to a distance of 7.5 mtr long, GI earth strip encased in and including 40mm bore GI light grade pipe, with 20mm bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, MS funnel with wire mesh fixed on water pipe including excavation earth work, provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforced with MS bars 8mm dia @ 150 mm centre to centre, both ways complete with lifting handle all as shown in electrical plate No 3 of SSR of part-I complete all as specified and as directed.
Supply, installation, testing and commissioning, factory made and tested, LT Panel, Outdoor type, platform mounted, suitable for 415 Volts, 3 Phase and neutral, 4 wire, 50Hz, AC supply system, having bus bar chamber with insulated electrolytic Aluminium bus bars, TPN, of capacity 800 Amps rating, installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, made out of 2.00 mm thick CRCA mild steel sheet and mild steel & Mounting 75 mmX 50mm Channel frame work, front openable type, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 Sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey RAL- 7035 shade. The panel shall be suitable for accommodating and inclusive of following accessories specified in srl no 14.01 & 14.02 here-in-after :-
OUTGOING SUPPLY:- (ii) MCCB 250 Amps, thermal magnetic release 415 volts , 50Hz, 35 KA, 4 Pole = 02 No., (iii) MCCB 160 Amps, thermal magnetic release 415 volts , 50Hz, 25 KA, 4 Pole = 02 Nos., (iv) MCCB 125 Amps, thermal magnetic release 415 volts , 50Hz, 25 KA, 4 Pole = 02 Nos., (v) MCCB 100 Amps, thermal magnetic release 415 volts , 50Hz, 25 KA, 4 Pole = 02 No., (vi) PCC and block masonary work for grouting of panel complete all as specified.
Supply and installation, testing, commissioning outdoor type feeder pillar Box made out of 3.15 mm thick CRCA sheet, 415 Volt, 3 phase, 50 HZ supply factory made & MS angle section 40 x40x 5mm frame with front and back openable double door with provision of locking arrangement dust & varmin proof, gasket, Aluminium 600 Amp TP busbar & 400 Amp for Neutral shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof duly spray painted inside and outside of panel with one coat of red oxide primer and two coat of synthetic enamel paint grey complete all as specified and directed & Consisting of the following equipments:- (i) MCCB, 4 Pole , 35 KA , 200 Amp -01 No (Incoming) (ii) MCCB, 4 pole , 25 KA, 100 Amps -04Nos (iii) MCCB, 4 Pole , 10 KA , 63 Amps - 03 Nos (iv) MCB, 10 KA, TPN 63 Amp - 03Nos iv) MCB, 10 KA, TPN 40 Amp - 06 Nos (vi) Indication Lamp 22.5 mm dia LED type 240Volts AC to show three phase availability- 01 set. (vii) Solid aluminium bus bar 600 Amp for 3 phase , 400 Amp for neutral (viii) PCC and block Masonary work for grouting of panel complete all as specified and directed.
Supply and installation, testing, commissioning outdoor type feeder piller Box made out of 3.15 mm thick CRCA sheet, 415 Volt, 3 phase, 50 HZ supply factory made & MS angle section 40 x40x 5mm frame with front and back openable double door with provision of locking arrangement dust & varmin proof, gasket, Aluminium 600 Amp TP busbar & 400 Amp for Neutral shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof duly spray painted inside and outside of panel with one coat of red oxide primer and two coat of synthetic enamel paint grey complete all as specified and directed & Consisting of the following equipments:- (i) MCCB, 4 Pole, 35 KA, 250 Amp - 01 No ( Incoming) (ii) MCCB, 4 pole, 16 KA, 100 Amps - 04Nos (iii) MCCB, 4 Pole, 16 KA, 63 Amps - 03 Nos (iv) MCB, 4 Pole, 10 KA, 63 Amp - 03 Nos (iv) MCB, 4 Pole, 10 KA, 40 Amp - 03 Nos (v) single Multifunction meter RE485 Port -6436 - 01 Nos, (vi) Indication Lamp 22.5 mm dia LED type 240Volts AC to show three phase availability- 01 set. MAKE : L&T/Secure/Conserv. (vii) Solid aluminium bus bar 600 Amp for 3 phase, 400 Amp for neutral (viii) PCC and block Masonary work for grouting of panel complete all as specified and directed.
Supply, installation, testing and commissioning Diesel Engine driven generating set of 160 KVA capacity, 3 phase, 4 wire, 415 V, 1500 RPM, AC power supply with power factor 0.8, coupled directly to alternator, mounted on a common base plate complete with integral acoustic enclosures (shall have salient features) modular bolted construction & pure polyester based coating to ensure long life in all weather conditions & for outdoor application / installation, integrated design thereby facilitating / easy handling. The design of integral acoustic enclosure shall be approved by National Physical laboratory as per central pollution control board (CPCB) latest regulation / norms with fuel tank, battery & standard accessories, tools & spares as provided by manufacturer complete with necessary PCC foundations including excavation and earth work with block measonary work and plastering complete with following specifications specified in srl no 17.01 to 17.07 here-in-after complete all as specified and as directed:-
(A) ENGINE- Water cooled diesel engine at 1500 RPM, of capacity to match the 160 KVA alternator under NTP conditions with provision of 10 % over load for 1 hour in every 12 hours running confirming to BS 5514/ IS 10001/ 10002. The Engine shall consist of the following:-
(a) Fly wheel with starter ring (b) Flexible coupling with guard (c) Cooling fan (d) Radiator with guard and water pump engine mounted (e) Dynamo of suitable capacity (f) Air cleaner heavy duty dry (g) Fuel injection pump (h) Radiator fan ( Blower type ) with guard (j) Electronic governor (k) Fuel filter (Mounted) (l) Lubricating oil filters ( mounted) (m) 12 v self regulating alternator belt driven by engine (n) Exhaust silencer heavy duty residential type (o) Corrosion resistor /scale inhibitor (p) Starter 12 V DC (q) Lubricating oil cooler (r) Lubricating oil pump (Gear type ) (s) Turbo charger (t) Exhaust piping shall be insulated with asbestos rope duly cladded with aluminium sheet.
(u) Instrument panel complete with :- (v) Auto manual Starting switch with key (w) Lubricating oil temperature gauge (x) Lubricating oil pressure gauge (y) Water temperature gauge (z) Battery charging ammeter (aa) Battery charging indicating lamp (ab) Hour meter with RPM indicator (ac) Safety control against high temperature of water. (ad) Safety control against low lubricating oil pressure . (ae) Over speed stop with double driven adopter .
(B) BRUSH LESS ALTERNATOR (i) Alternator coupled to engine indigenous make through a flexible coupling mounted on sturdy steel fabricated base frame suitable for mounting on a permanent foundation brushless alternator shall be confirming to BS -2613 or relevant of IS-4722/ IS 13364. (ii) Type :- Self excited self regulated with automatic voltage regulator. (iii) Rating :- 160 KVA at 0.8 PF lagging 4 pole horizontal at NTP condition. (iv) Speed :- 1500 RPM (v) System :- 415 V +/- 2.5 % AC 3 phase 4 wire 50 Hz. (vi) Connection :- 4 wire star connected. (vii) Enclosure :- Screen protected drip proof. (viii) Ventilation :- Self ventilated. (ix) Insulation :- Insulation class H
(C) CONTROL PANEL The control panel with aluminium bas bar, bottom entry and exit of cable, current transformer, set of control fuses, Multifunctional Meter, it should display time and date, Volts, Frequency, Current, KW, KWH, PF, RPM, Cumulative Run Hours, Oil Pressure, Coolant Temp, Charging current (DC Amp Meter). Emergency off, factory made floor mounted, totally enclosed, epoxy powder coated suitable for 160 KVA DG Set including all necessary operating controlled devices as stated above and MCCBs as out going with protection fuse for panel instruments duly wired with flexible copper conductor cable and cable connection with lugs/thimbles complete as per latest IS/BS complete all as specified and directed.
(D) ONE SET OF ACCESSORIES COMPRISING OF:- (a) Fuel tank - Capacity of tank shall be to hold diesel sufficient for 08 hours running at full load, with following features: (i) Level indicator. (ii) drain plug . (iii) MS class 'C' piping for inlet from pump to tank to engine. (iv) Fuel strainer. (v) Air vent. (B) Sealed maintenance free Battery :- Heavy duty battery two nos 24 plates 12 v 180 AH (01 Nos) connected to the system fully charged including lead and battery terminal's complete . (d) Base plate :- Fabricated out of MS channel's ISMC of suitable size suitable for fixing of DG set all specified by the manufacturer.
E) AMF PANEL:- Supply, fixing, testing and commissioning Auto main failure (AMF) panel, 15 SWG, 160 KVA DG Set Cubical consist of sheet steel enclosure of 2.00 mm thick totally enclosed dust and water proof duly painted with powder coated, fully wired up and ready to connect load & control lines in comprising the followings:- (a) Indication lamp LED type Green (IL1)- 01 No. b) Indication Lamp LED type Green (IL2) – 01 No. c) Control Supply ON/OFF switch (TS1) - 01 No. d) Canopy light ON /OFF Toggle switch ( TS2) - 01 No. e) Generator Controller unit (GCU) - 01 No f) Power contactor , AC-01 Duty, With Wide Band Coil ( 230AC), 2 NO + 2 NC Auxiliary contacts - 01 NO g) Fuse link - 02 Set h) Fuse Holder & Base - 02 Set i) Current transformer - 03 Nos j) DC Ammeter - 01 No k) Hotter – 01 No. l) HTR,CFAR,GCR & MCR Relay - 01 Set m) Glass fuse holder - 08 Nos. n) Glass Fuse - 07 Nos (o) Battery Charger - 01 NO (p) Control Terminals - 02 Nos (q) Miniature Circuit Breaker ( MCB) - 01 No (r) Aluminium Busbar 40 x 10 mm - 01 set (s) Control Connector - 03 Nos (t) ECD Card - 01 No (u) Control Connector with suitable terminals - 01 Set
S&F Steel work in tubular trusses, purlins, rafter, vertical post and similar works including special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS- 1161-1979 gde SI-240 including one shop coat of zinc chromate primer paint incl preparation of surface at contractor workshop before fabrication complete all as specified and directed.
S & F plain MS plate including cutting / welding & drilling (Fe 410- w Gde-E 250 Quality A) complete all as specified & directed.
S & F framed bracket of angles or tees with web and flanges cut to shape, drilled and counter, sunk for screw, including bending and welding, as necessary gusset plates, riveting etc not exc 10 kg each bracket, confirming to Fe 290 grade E 165 complete all as specified and directed.
M&L shade covering with galvanised, corrugated mild steel sheeting of thickness 0.80mm with two corrugations of side lap, fixed with L type and J type hook and washers, in roofs wall with grade of zinc coating 275 complete all as specified and directed.
Boring of holes under road pavement hard standing by trenchless technology with manual boaring technologly 80 mm dia bore complete all as specified and directed.
Supply, installation, testing and commissioning 315 KVA, 11/0.433KV, AN, Oil Type Transformer with corrugated off circuit tap links of rating +5 to - 5% @2.5 %.by means of hand operated off load tap changing gear 315 kVA capacity transformer copper wound step down outdoor type, 11000/433 Volt (at no load), double wound, oil immersed naturally cooled with external cooling tubes, core type delta connected on primary side (HV) and star connected on secondary side(LV) in accordance with vector symbol Dy-II (vector group) with neutral brought on secondary side (LV side) and having tapping changing at + /-7.5% in step of +/- 2.5 %, to be changed and the maximum temperature rise shall not exceed 45 degree centigrade in oil and 55 degree centigrade in HV/LV winding when measured by resistance method after continuous full load run in ambient temp of 40 degree centigrade and the transformer shall be comprised with the following standard fittings including necessary foundation with block masonry work complete all as specified and as directed with following specifications specified in Srl No 23.01 here-in-after:- Note: Transformer shall be double copper wound (Level -02) as per IS : 1180 (Part -1) 2014 with HT, LT cable Box.
(i) Pressure Release Valve (ii) Thermometer pocket on tank cover (iii) Oil temperature indicator with 2 contacts alarm & trip (iv) Rating plate with terminal marking (v) Two earthing terminals on tank and cover to facilitate fixing of GI earth strip (vi) Oil level gauge (vii) Oil drain filter valve (viii) Lifting lugs (ix) Oil filter hole with cap/plug including connection complete (x) Four plain solid cast steel detachable rollers (xi) First fill of transformer oil confirming to relevant IS and testing up to 60 KV di-electric strength (xii) PCC Foundation with block masonry & Plaster work as per manufacturer's instruction and as directed.
Supply, installation, testing and commissioning 11 KV , 630 Amps, outdoor type Compact switch gear Ring Main unit, Extensible type, having 02 Nos. Load Break Switches and 01 No Vacuum circuit breaker, all Manual Operated modules with IP class as IP 54, for outer door separately , inside the RMU there shall be an additional cable door with IP3X and Mimic of IP2X and necessary PCC foundation work as per manufacturer's instructions, along with bottom cable entry and front cable termination complete all as specified and as directed with following Accessories & specification specified in Srl No 24.01 to 24.06 here-in-after:-
(A) 630A manual Load Break Switch module for making of fault current along with Earth Switch of full making capacity -2 Nos. Short time withstand current - 21KA/ 3 sec Making Capacity - 52.5kAp Auxiliary contacts - 1NO + 1NC Power frequency withstand voltage - 28kV Impulse withstand voltage - 75kVp Nominal operating gas pressure - 1.4 Bar abs. Front cover mechanism - IP2X Cable covers - 3X Snap action mechanism for manual operation Cable box for front termination of the cable suitable up to 3 core 300 Sqmm, 11 KV XLPE cable Right angle non-touch proof Termination boots - 1 Set (R,Y,B) Set of 03nos. Ring Core Metering CTs 150-300/1A as per feeder load, 2.5VA, Class 1.0
(B) 630A manual VCB module for making & breaking of fault current along with Earth Switch of full making capacity -1 No Manual operated 630 A Vacuum circuit breaker having spring stored mechanism. Three position disconnector/earthing switch downstream vacuum circuit-breaker. Three position single spring mechanism for disconnector/earthing switch “Live Cable” LED Indicators thru Capacitor Voltage Dividers mounted on the bushings. Short time breaking current - 21KA/ 3 sec Making Capacity - 52.5 kAp Auxiliary contacts - 1NO + 1NC Power frequency withstand voltage - 28KV Impulse withstand voltage - 75kVp Nominal operating gas pressure - 1.4 Bar abs. Front cover mechanism - IP2X Cable covers - 3X Green(ON)/Red(OFF) push buttons to operate VCB. 3O/C + 1E/F self powered numerical protection relay with Low and High set for Over current and Earth Fault. Mechanical ON/OFF/EARTH/Spring charge Indication Cable boxes should be Arc Proof interlocked with respective Earthing Switches. Right angle non-touch proof Termination boots - 1 Set (R,Y,B)
Stored energy mech. for manual operation - 01 Nos Set of 03nos. Ring Core Protection CTs of ratio 40-80A/1A as per feeder load, 2.5VA, 10P10 - 01 Set Set of 03nos. Ring Core Metering CTs of ratio 40-80A/1A as per feeder load, 2.5VA, Class 1.0 - 01 Set Capacitive voltage indication fixed type VPIS 6-12 kV - 01 Nos
(C) Set of 03 Nos. single-phase potential transformers having ratio 11kV/rt3:110V/rt3, 25VA, Class 1.0 with HRC fuses for protection on primary side and MCBs for protection on secondary side.- 01 Set Space Heater (230VAC)- 01 Nos Low Voltage Box containing • Multifunction Meter for each module showing kVA, kVAR, kW, Hz etc in the same . • R-Y-B Phase Indication Set of Coupling bus bars along with suitable coupling kit.- 01 Nos Manometer- 01 Nos Operating handle- 01 Nos
Notes for item No 24.00:- (a) RMU Tank shall be IAC AFL 20kA/1s tested to ensure utmost operator safety .Test report (from an STL member Lab) shall be submitted along with drawings of the RMUs . In case the test report is not found suitable , the RMU shall stand liable to be rejected. (b) The Vacuum Bottle shall be of same make as that of RMU to ensure better life cycle optimization for the RMU. (c) Additional items like Operating handle etc. shall be delivered with the RMU (d) RMU tank shall be of 304 grade, Non-magnetic, Non-ferrite Stainless Steel. Inferior Grade of Steel shall not be acceptable. (e) RMU shall have site replaceable bushings for ease of trouble shooting at site and quick repair and restoration at site. (f) Earth switch shall be on line side and shall have making capacity.
Notes for item No 24.00 (Contd...):- (g) The Quoted rates for RMU shall be inclusive of making Platform as per OEM instructions, made with bricks and necessary PCC at Bottom and Top and plastering complete all as directed.
Flint India
Vishal Traders
R. S. Associates
Satish Kumar Gupta
Shiv Enterprises
BLUE HILL ELECTRICAL AND ELECTRONICS
New Era Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .