Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.6 LAccepted-AOC | L1 | Accepted-AOC Being L-1 | |
| 2 | L2₹48.4 L+₹3.8 L (8.58%)Rejected-AOC H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | L2 | Rejected-AOC Being L-2 | |
| 3 | L3₹51.0 L+₹6.4 L (14.5%)Rejected-AOC HOUSE NO 44 MASTER COLONY SATROD KHAS HISAR HARYANA 125044 | HISAR | HISAR | HARYANA | 125044 | L3 | Rejected-AOC Being L-3 | |
| 4 | L4₹52.4 L+₹7.9 L (17.7%)Rejected-AOC | L4 | Rejected-AOC Being L-4 | |
| 5 | L5₹52.7 L+₹8.1 L (18.3%)Rejected-AOC | L5 | Rejected-AOC Being L-5 |
Tender Value
₹68 L
EMD Value
₹1.3 L
Closing Date
4 Apr 2024, 6:00 pmClosed
CWE Chandimandir
HQ CWE Chandimandir
CA NO. CWE/KAS-100/2023-24 SPECIAL REPAIR TO BUILDING NO. AL-09 (OTM) OF 11 KUMAON AT DAGSHAI CANTT UNDER GE KASAULI
2024_MES_644502_1
CWE/KAS-100/2023-24
Open Tender
Miscellaneous Works
Item Rate
180 days
HQ CWE Chandimandir
Class C category a(i)
8 documents required · 8 mandatory
₹1,000
Yes
GE Kasauli
₹1.3 L
Yes
26 Jun 2024
28 Feb 2024
6 Apr 2024
28 Feb 2024
4 Apr 2024
21 Mar 2024
29 Feb 2024 - 7 Mar 2024
Amount
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed by the Engineer-in-Charge.
S&F Galvanised, corrugated mild steel sheeting 0.63mm thick with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275 complete all as specified and as directed by the Engineer-in-Charge.
S&F Plain, galvanised, mild steel sheeting 0.63mm thick, as in ridges, hips, valley, gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and as directed by the Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for etc complete all as specified and as directed by the Engineer-in-Charge.
Dismantling timber scantling 40 sq.cm and under in section, in any position in framed work etc complete all as specified and as directed by the Engineer-in-Charge.
S&F for framed work such as grills, gratings, etc. with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe 290 Gde-E-165 complete all as specified and as directed by the Engineer-in-Charge.
S&F Hard drawn steel wire fabric weight n.exc 4 kg/Sqm cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcemnt etc complete all as specified and as directed by the Engineer-in-Charge.
Dismantling timber scantling 40 sq.cm and over in section in any position in framed work etc complete all as specified and as directed by the Engineer-in-Charge.
S & F for 2nd class hard wood over 40 sqcm in Scantling clean sawn timber framed and fixed complete all as specified and as directed by the Engineer-in-Charge.
M&L for 6 mm thick Plywood, grade BWR, type BB, fixed with screws to timber frame work, complete all as specified and as directed by the Engineer-in-Charge.
M&L for 2nd class hard wood plain fillets cross sectional area exc 13 & n.exc 25 sq.cm, square, rectangular or triangular in section, clean sawn, secured with nails or brads, complete all as specified and as directed by the Engineer-in-Charge.
M&L for 2nd class hard wood plain fillets, cross sectional area exc 06 & n.exc 13 sq.cm, square, rectangular or triangular in section, clean sawn, secured with nails or brads, complete all as specified and as directed by the Engineer-in-Charge.
Taking down cement plaster on brick or stone wall, Ceilling etc including racking out joints, hacking for key scrubbing down with water etc to receive new plaster etc complete all as specified and as directed by the Engineer-in-Charge.
M&L for Rendering 20 mm thick on stone work in Cement Mortar 1:6, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Taking down shutter of any description exc 1 Sq.m but n.exc 2.0 Sqm each complete all as specified and as directed by the Engineer-in-Charge.
S & F 35 mm thick, factory made, 2nd class hard wood, plain framed, paneled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both sides, the size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated etc complete all as specified and as directed by the Engineer-in-Charge.
Taking down Shutters of any description exc 1 sq. m and n exc 2 sq. m each and refixing in same opening complete all as specified and as directed by the Engineer-in-Charge.
Demolition of brick or stone masonary built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facing dressed stone work and precast concrete block complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for brick work with sub class ‘B’ old size bricks, straight or curved on plan exc 6.0m mean radius in cement mortar 1:6, complete all as specified and as directed by the Engineer-in-Charge.
M & L for applying 1 mm thick Cement based wall care putty on walls etc complete all as specified and as directed by the Engineer-in-Charge.
M&L for Preparation of newly plastered surfaces of walls and applying two coat of oil bound distempering over wall care putty complete all as specified and as directed by the Engineer-in-Charge. Note: Wall care putty shall be measured and paid separately under respective item here-in-before.
M&L for complete removal of existing treatment of walls and applying two coat of oil bound distempering over wall care putty complete all as specified and as directed by the Engineer-in-Charge. Note: Wall care putty shall be measured and paid separately under respective item here-in-before.
M&L for preparation of unplastered wall surfaces/ complete removal of existing treatment of walls and applying two coat of exterior emulsion paint over a coat of primer of approved tint and make etc complete all as specified and as directed by the Engineer-in-Charge.
M&L for preparation of Old plastered wall surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of primer when unconnected with other painting or when painted in different tint and make etc complete all as specified and as directed by the Engineer-in-Charge.
M&L for preparation of new steel surfaces of any description over 10cm in width or girth not other wise described and applying two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and as directed by the Engineer-in-Charge.
M&L for preparation of new wooden surfaces of any description over 10cm in width or girth not other wise described and applying two coats of synthetic enamel paint over a coat of pink primer etc complete all as specified and as directed by the Engineer-in-Charge.
M&L for preparation of old painted steel surfaces of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and as directed by the Engineer-in-Charge.
M&L for preparation of old painted wooden surfaces of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair 100 mm long butt hinges medium weight cold rolled mild steel and fixed complete all as specified and as directed by the Engineer-in-Charge.
S & F in repair for Aluminium anodized 200mm long barrel tower bolt of extruded section and fixed complete all as specified and as directed by the Engineer-in-Charge.
S & F in repair for Aluminium anodized 150 mm long barrel tower bolt of extruded section and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair 150mm long aluminium anodized handles febricated type complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair 300mm long Aluminium alloy anodised sliding door bolt with hasp and staple(bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolt of extruded section or cast aluminium alloy and fixed etc complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair for curtain rod, powder coated ornamental type, dia 25mm including brackes (2 Nos), end caps (2 Nos) complete all as specified and as directed by the Engineer-in-Charge.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed by the Engineer-in-Charge.
M&L for Sheet glass 3.00 mm thick fixed with windows frame of area of each pane n exc 0.50 Sqm complete all as specified and as directed by the Engineer-in-Charge.
Dismantling wall and ceiling board (fibre, pulp, insulation etc) or insulation boards/ kitchen cupboard, any thickness etc. including cover fillets complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), and removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by the Engineer-in-Charge.
M&L for Non skid ceramic coloured tiles 7mm to 8mm thick (squre/ rectangular) area of each tile exc 0.11sqm but not exc 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed with cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M&L for Glazed ceramic coloured tiles 450 X 300 X 7mm thick, laid in vertical surfaces etc set and jointed in neat cement slurry and pointed in coloured cement to match tiles over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M & L for Non Skid ceramic coloured tiles 7 to 8 mm thick (squares/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors set and jointed in neat cement slurry and pointed in coloured cement to match tiles over and including 20 mm thick screed bed 1:6 including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and as directed by the Engineer-in-Charge.
M & L for Non Skid ceramic coloured tiles 7 to 8 mm thick (squares/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in wall skirting set and jointed in neat cement slurry and pointed in coloured cement to match tiles over and including 10mm thick rendering in cement mortar 1:4 complete all as specified directed by Engr-in-Charge.
S & F Powder Coated Anodised aluminium frame for doors, windows, parttions, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed by the Engineer-in-Charge.
S & F powder coated aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos and locking arragement in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and as directed by the Engineer-in-Charge.
S&F 9mm thick pre-laminated particle board, interior grade, both side lamination of approved colour and pattern fixed to wooden/ aluminium frame work as in door/ cupboard shutters complete all as specified and as directed by the Engineer-in-Charge.
M&L for 18/ 19 mm Pre laminated Particle boards, exterior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with nails complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair, Continuous (piano) hinges, mild steel, bright finish or electro galvanised bright finish, width of flaps (when open) 30 mm complete all as specified and as directed by the Engineer-in-Charge.
S&F 100 mm long extruded stainless steel handle, fabricated type, anodised, complete all as specified and as directed by the Engineer-in-Charge.
S&F PVC rain water half round gutter pipe of size 110 mm dia fixed with clamp up to a height 12 mtr and taking down eaves gutters and rainwater pipes (any size or pattern) with all fittings, heads, shoes, bends, swan-necks, etc., including necessary scaffolding complete all as specified and as directed by the Engineer-in-Charge.
M&L for PVC edge strip of 18/ 19 mm wide, colour and pattern as approved fixed with adhesive complete all as specified and as directed by the Engineer-in-Charge.
M&L for MS Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required complete all as specified and as directed by the Engineer-in-Charge.
S&F for 110mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors/ wall complete all as specified and as directed by the Engineer-in-Charge.
S&F PVC rain water gutter drop elbow for 110 mm dia pipe fixed to PVC pipe complete all as specified and as directed by the Engineer-in-Charge.
M&L for 50mm thick PCC 1:3:6 type C-1 using 20mm graded stone aggregates as in plinth protection finished even and smooth without using extra cement etc. Including demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) and disposing off the rubbish materials complete all as specified and as directed .
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power socket) with complete fitting such as switches, sockets, lamp holder, utility light fitting, fan regulator, ceiling rose etc and removing materials from sites and making good distrubed surface of walls and roofs complete all as specified and as directed by Engineer-in-charge.
Material and labour for point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm, 1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm, 1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new PVC conduit concealed in wall and including new sunken box and suitable size of frame, cover for mounting switches, socket and regulator fixed on surface flush with wall, comprising of One light/ bell/ buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator complete all as specified and as directed by Engineer-in-charge.
One Light/Fan point controlled by one, one way switch 6 Amp complete all as specified and as directed by the Engineer-in-Charge.
One switch socket outlet 3 pin, 5 Amp on the independent board complete all as specified and as directed by the Engineer-in-Charge.
One switch socket outlet 3 pin, 5 Amp on same board complete all as specified and as directed by the Engineer-in-Charge.
All as per item No. 56 here-in-before but 4.0 sqmm single core multi stranded copper conductor PVC insulated unsheathed (FRLSH) cable 1100 volts incuding 4.0 sqmm stranded copper conductor (FRLSH) PVC insulated green in colour as continous earth conductor connected to common earth and earth dolly with all accessories for one 5 pin 16 Amp socket (Power point) on independent board complete all as specified and as directed by the Engineer-in-Charge.
M & L for sub main wiring with single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm (Nominal area) drawn through in and including PVC conduit required size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm as earth lead and connected to earth dolly and making good to disturbed surfaces etc, incl taking down unsv submain wiring all as specified and directed.
M & L for sub main wiring with single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 10.0 sqmm (Nominal area) drawn through in and including PVC conduit required size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 10.0 sqmm as earth lead and connected to earth dolly and making good to disturbed surfaces etc, incl taking down unsv submain wiring complete all as specified and as directed by the Engineer-in-Charge.
S & F switch piano flush button single pole one way, 6 Amps, 240 Volt complete all as specified and as directed by the Engineer-in-Charge.
S & F socket outlet 2-in-1 5 pin, 6 Amps flush type complete all as specified and as directed by the Engineer-in-Charge.
S&F switch piano flush button single pole one way, 16 Amps, 230/240 V complete all as specified and as directed by the Engineer-in-Charge.
S&F socket outlet 2-in-1, 5 pin, 6 & 16 Amps, flush type complete all as specified and as directed by the Engineer-in-Charge.
S & F ceiling rose surface, backelite, three terminal, 240 volts complete all as specified and as directed by the Engineer-in-Charge.
S & F lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed by the Engineer-in-Charge.
S&F Wall mounted LED, batten box type, pre coated CRCA body suitable for retrofit LED tube rod 18 Watts including LED self ballasted LED retrofit tube lamp 18 Watt with thermoplastic body min 1800 system lumens and built in surge protection of 2.5 KV and taking down unsv complete all as specified and as directed by the Engineer-in-Charge.
S&F Wall mounted mirror light LED fitting self ballasted LED batten extruded thermoplastic body with PC diffuser in unique square shaped 10 watts, 2 Feet long CCT 6500K fixed in repair taking down unsv fitting any type complete all as specified and as directed by the Engineer-in-Charge.
S&F Surface mounted LED bulk head 10 watt luminaire with ABS body & polycarbonate diffuser IP 65 including connecting to ceiling rose with 0.5 sqmm two core copper flexible conductor cable incl taking down unsv light fiting any type complete all as specified and as directed by the Engineer-in-Charge.
S&F self ballasted LED Retrofit Bulb, 5 Star, 12 Watt with PBT body shell and PC diffuser. 210 digree wide distruction CCT 6500K, B-22 cap, (Pin type), 230V, PF-0.95 (min) incl taking out unsv CFL/LED Bulb complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing building security LED light, 35 Watt, energy saving LED, made up of pressure dia cast housing with toughened glass and high power LEDs with option of secondary optic with IP66 protection including one GI medium grade 25mm dia bracket of total length 50 cm fixed with 2 Nos MS Clamp and fastners including taking down unsv light fitting complete all as specified and as directed by the Engineer-in-Charge.
S&F MCB DB, TPN, 4 way, double door, IP 42, CRCA sheet powder coated vertical type factory made, suitable for incorporating MCB as outgoing and MCCB as incoming including connecting incoming and outgoing cables & blaking plate as required incl taking down existing unsv DB of any size and making good distrubed surface to match with existing complete all as specified and as directed by the Engineer-in-Charge.
S&F MCB DB, SPN, 8 way, double door, IP 42, CRCA sheet powder coated, factory made, suitable for incorporating MCB as out going and MCCB as incoming connecting incoming and outgoing cables & blaking plate as required incl taking out existing unsv DB of any size and making good disturbed surface to match with existing incl taking down unsv DB of any size complete all as specified and as directed by the Engineer-in-Charge.
S&F MCCB, 4 Pole, 100 Amps, 16 KA breaking capacity lcs=100 % lcu, 415 Volt, including taking down unserviceable MCCB complete all as specified and as directed by the Engineer-in-Charge.
S&F in replacement Isolator MCB SPN, 32 Amp to 40 Amp complete all as specified and as directed by the Engineer-in-Charge.
S&F in replacement Isolator MCB SP, 6 Amp to 40 Amp, complete all as specified and as directed by the Engineer-in-Charge.
S&F Heating Element, ISI Marked, round/ tringular base, push type or thread type including rubber washer for 1.5/2.0 KW suitable for geysers 25 Ltrs to 50 Ltrs capacity (as per existing) including taking down unserviceable one complete all as specified and as directed by the Engineer-in-Charge.
S&F thermostat, ISI Marked, suitable for geysers 25/50 Ltrs capacity (as per existing) including taking down unserviceable on complete all as specified and as directed by the Engineer-in-Charge.
S&F Chromium plated connections 45 Cm long for Hot/Cold water of 15mm size with chromium nuts and washers fixed as in repairs complete all as specified and as directed by the Engineer-in-Charge.
S & F single pole and neutral enclosure with a two pin and earth plug and socket board with IS 13032, IS 8623 complete with one single pole 20 amp MCB including taking down old unsv one complete all as specified and as directed by the Engineer-in-Charge.
Taking down the geyser of 25/ 50 ltr capacities from the site after disconnecting the water connection, electric connection, opening the geyser assembly and descaling the deposited impurities in the inner container and outlet water pipe set and refix on the wall with fastener of 4 nos each complete all as directed by Engineer-in-Charge. (Note:-1. items such as replacement of unserviceable bolts, rubber real, ring nuts, washers shall be included in the quoted rate itself. 2. Other Items such as thermostat, Heating element, MCB, connection pipe if required, shall be measured and paid separately).
Material & labour for earthing complete with galvanised mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No.3 of SSR part I connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 150mm center to centre both way with suitable lifting handle and pit / chamber in PCC 1:3:6 type C1, for pit cover including testing on completion complete all as specified and as directed by Engineer-in-charge.
Note:- Quoted rates shall be deemed to include for earth wire with protection pipe up to 7.5 M length.
R B TRADERS
m/s AR Construction co
Durga Construction
R. P. Suppliers and Construction Co.
M/S CHOPRA & COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .