Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC | ₹1.2 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹1.3 Cr+₹49,814.60 (0.40%)Rejected-Finance | ₹1.3 Cr+₹49,814.60 (0.40%) | L2 | Rejected-Finance Being lowest |
| 3 | L3₹1.3 Cr+₹5.0 L (4.02%)Rejected-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | ₹1.3 Cr+₹5.0 L (4.02%) | L3 | Rejected-Finance Being lowest |
| 4 | L4₹1.4 Cr+₹13.6 L (10.9%)Rejected-Finance | ₹1.4 Cr+₹13.6 L (10.9%) | L4 | Rejected-Finance Being lowest |
Tender Value
₹1.4 Cr
EMD Value
₹2.1 L
Closing Date
3 Apr 2024, 6:00 pmClosed
CHIEF ENGINEER
CHIEF ENGINEER RND SECUNDERABAD PICKET OPP JUBILEE BUS STATION SECUNDERABAD-500003
IN HOUSE SITE DEVELOPMENT OF HYDRAULIC ACTUATOR LABORATORY AT ADE UNDER GE I RND EAST BANGALORE
2024_MES_641172_2
82650
Open Tender
Civil Works
Item Rate
270 days
Bangalore
Class B category a (i)
7 documents required · 7 mandatory
₹1,000
GARRISON ENGINEER RND EAST BANGALORE
₹2.1 L
Yes
20 May 2024
13 Mar 2024
10 Apr 2024
13 Mar 2024
3 Apr 2024
20 Mar 2024
Amount
Dismantling of asbestos cement corrugated sheets of roof covering / north light curve sheets (height up to 12 to 15 Mtr, factory type bldg / Hangar) complete all as specified and directed.
Providing & fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05%) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-Charge. The sheet shall be fixed using self drilling / self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal / vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required complete all as specified and directed.
Providing & fixing precoated galvanised steel sheet roofing (north) light curved) accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling / self tapping screws complete all as specified and directed. Note: Width including curve shape will not be less than 1.00 Mtr.
S&F in repairs (including dismantling) GI plain, galvanised mild steel sheeting, 1.25mm thick, as in valley gutters with grade of zinc coating 275 of fixed with clamp complete all as specified and directed. Note: (a) Approximate height of the work is upto 12 Mtr. (b) There is no accessibility to the roof. (c) Necessary scaffolding if necessary to fix valley gutter.
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead complete all as specified and directed.
Labour for fabrication and fixing only, by using dismantled material including cutting, hoisting, fixing in position all complete after made it shaped with old steel obtained from dismatled material (from item No. 5) including shaping, welding if required complete all as specified and directed.
M&L for Steel work (hot finished welded type tubes) in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete all as specified and directed.
M&L for painting with synthetic enamel paint on steel surface of approved brand and manufacture to give an even shade two or more coats on new work complete all as specified and directed.
Painting with synthetic enamel paint on steel surface of approved brand and manufacture of required colour to give an even shade one or more coats on old work complete all as specified and directed.
Rough cast wired figured glass, 6 mm thick fixed to metal frame supply and fix complete all as directed including removing of old broken / damgaed glass complete all as specified and directed.
Providing & fixing aluminum U/square beading of required size to fix wired glass including fixing etc. complete as per direction of Engineer-in-Charge.
Demolition of PCC (un-reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for 75mm thick cement concrete flooring 1:2:4 (1 cement : 2 coarse sand by using 20mm graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete all as specified and directed.
M&L for Vinyl flooring 2mm thick (choice colour) paste over PCC surface with adhesive and as directed by Engineer-in-Charge. Note: Flooring to be carried out by authorised manufacturer as per their instructions.
Demolition of Stone / brick work / PCC block or stone boulder masonry built in cement mortar complete all as specified and directed.
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 Metres lead complete all as specified and directed.
Material and labour for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement plaster 1:6 finished even and smooth without using extra cement complete all as specified and directed.
Preparing the surfaces of newly plastered wall surfaces and applying two coats of acrylic emulsion paint over a coat of water thinnable primer over 2mm thick wall care putty finish complete all as specified and directed.
Distempering with 1st quality acrylic distemper (Ready mix) having VOC content less than 50 grams / litre of approved brand and manufacture to give an even shade old work (one coat) complete all as specified and directed.
Finishing walls with 100% premium acrylic weather proof emulsion paint New work (two coats) applied @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives complete all as specified and directed.
All as per Sl item No. 20 above, but on old surfaces after and including complete removal of existing treatment of any type and condition complete all as directed by Engineer-in-Charge.
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead for thickness of tiles 10 mm to 25 mm complete all as specified and directed.
Cement concrete 25mm 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished below tiles, including cement slurry but excluding the cost of nosing of steps etc. complete all as specified and directed.
Providing & laying double charged vitrified floor tiles size of tile 600 x 600 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete all as specified and directed.
All as per Sl item No. 24 here-in-before but as in skirting including 12 mm thick screed bed in CM 1:3.
Providing & fixing 1st quality coloured glazed ceramic tiles of size 450mm x 300mm / 450mm x 350mm, in dado / skirting etc. conforming to IS: 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete all as specified and directed.
M&L for Coloured Non Skid ceramic tiles (non-skid) of size 7 to 8 mm thick area of each tile not exceeding 0.18 sqm, in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
Painting with aluminium paint of approved brand and manufacture to give an even shade on steel rolling shutter, one coat on old work complete all as specified and directed.
Dismantling CI or asbestos, rain water pipe with fittings and clamps including stacking the material within 50 metres lead, 150 mm dia pipe complete all as specified and directed.
S&F for 150mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F for 150mm bore PVC (SWR) bends any radious provided complete all as specified and directed.
Painting with synthetic enamel paint of approved brand and manufacture of required colour on wooden surface to give an even shade : one coat on old work complete all as specified and directed.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead of area beyond 3 sq. metres complete all as specified and directed.
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead area beyond 3 sq. metres complete all as specified and directed.
Providing & fixing powder coated aluminium (minimum thickness of powder coating 50 micron aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete and the directions of Engineer-in-Charge. (Glazing, paneling and dash fasteners to be paid for separately.)
Providing & fixing aluminium tower bolts, 150mm x 10mm dia ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete all as specified and directed.
S&F, anodised aluminium butt hinges 100mm complete all as specified and directed.
Providing and fixing 125mm aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete all as specified and directed.
Providing & fixing PVC door frame of size 50x47 mm with a wall thickness of 5 mm (± 0.2 mm), made out of single piece extruded PVC profile with mitred cut joints and joint with 02 Nos of PVC bracket of size 190 mm x 100 mm long arms of cross section size 35 x 15 mm & self driven self taping screws, the vertical door profiles to be reinforced with 40 x 20 mm MS rectangular tube of 0.8 mm, including providing EPDM rubber gasket weather seal throughout the frame, including jointing 5 mm PVC frame strip with PVC solvent cement on the back of the profile. The door frame to be fixed to the wall using 8 x 100 mm long anchor fasteners complete, all as per manufacturer's specification and direction of Engineer-in-Charge.
M&L for 35 mm thick factory made solid panel PVC door shutter, decorative finish (wood grained finish) made out of single piece extruded soild PVC profiles, 5 mm (± 0.2 mm) thick, having styles & rails (except lock rail) of size 95 mmx 35 mm x 5 mm, out of which 75 mm shall be flat and 20 mm shall be tapered (on both side), having one side thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power, including reinforcing with MS tube of size 40 mm x 20 mm x 1 mm, joints of styles & rails to be mitered cut & joint with the help of PVC solvent cement, self driven self tapping screws & MS rectangular pipes bracket of size 190 mm x 100 mm of cross section size 35 mm x 17 mm x 1 mm at each corner. Single piece extruded 5 mm thick solid PVC lock rail of size 115 mm x 35 mm, out of which 75 mm to be flat and 20 mm to be tapered at both ends, having 15 mm solid core in middle of rail section integrally extruded, fixing the styles & rails with the help of solvent and self driven self tapping screws of 125 mm x 11 mm, including providing 5 mm single piece solid PVC extruded sheet inserted in the door as panel, all complete as per manufacturer's specification and direction of Engineer-in-Charge.
Dismantling 15 to 40 mm dia GI pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer-in-Charge.
Steel water tubing medium grade 15mm bore galvanized with all fittings and fixed to walls and ceiling or laid in floors including cutting chases where required complete all as specified and directed.
All as per Sl item No. 42 above but of size of 20mm bore.
Providing & placing on terrace (at all floor levels) 1000 liters capacity polyethylene water storage tank, IS: 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank including disconnection of old one and as directred by Engineer-in-Charge.
S&F in repairs CP brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore complete all as specified and directed.
Providing & fixing in repair CP brass angle stop cock (concealed) of standard design and of approved make conforming to IS:8931, 15 mm nominal bore complete all as specified and directed.
Providing & fixing in repair 10 ltr white colour PVC low level flushing cistern with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete all as specified and directed.
Providing & fixing in repair white vitreous china pedestal type water closet (European type WC pan) with seat and lid, 10 litre low level white PVC flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required (WC pan with ISI marked white solid plastic seat and lid).
Providing & fixing in repair ball valve (brass) of approved quality, high or low pressure, with plastic floats complete 20 mm nominal bore complete all as specified and directed.
Providing & fixing in repair white vitreous china clay half stall urinal flat back 580 x 380 x 350 mm or angle back 450 x 375 x 350 mm with waste fittings as per IS: 2556 complete all as specified and directed.
Providing & fixing in repair wash basin with CI brackets, 15 mm CP brass pillar taps, 32 mm CP brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: white vitreous china wash basin size 550 x 400 mm with 15 mm CP brass pillar tap complete all as specified and directed.
S&F in repair PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed.
Providing & fixing in repair CP towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms complete all as specified and directed.
Providing & fixing 4mm thick float glass panes of (weight not less than 10Kg/sqm) glazing in aluminium door, window, ventilator shutters and partitions etc, with EPDM rubber / neoprene gasket etc, complete as per the architectural drawings and the directions of Engineer-in-Charge. (Cost of aluminium snap beading shall be paid in basic item) and as directed by Engineer-in-Charge.
S&F in repair 600 x 450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with CP brass screws and washers complete complete all as directed by Engineer-in-Charge.
S&F in repair CP brass toilet paper holder of standard size complete all as specified and directed.
Providing & fixing in repair brass stop / angle cock of approved quality 15 mm nominal bore complete all as specified and directed.
Providing & fixing in repair PVC waste pipe for sink or wash basin including PVC waste fittings complete 32 mm dia (FLEXIBLE) complete all as specified and directed.
Providing & fixing in repair PTMT grating of approved quality and colour 100 mm nominal dia complete all as specified and directed.
Cutting chases in brick masonry walls for following diameter sand cast iron / centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) complete all as specified and directed.
Providing & laying factory made precast concrete solid blocks of 200 mm thickness of grade M10 made of C&D waste from approved manufacturer in superstructure above plinth level up to floor V level in cement mortar 1:6 and as directed by Engineer-in-Charge.
Providing & fixing with semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles, false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC 0.50 to 0.75 as per IS 8225:1987 non combustible as per BS 476 (Part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15 x 32 mm of length 3000 mm, cross-T of size 15 x 32 mm of length 1200 mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85 x 25 x 2 mm. Galvanised iron perimeter wall angle of size 24 x 24 x 0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.
Taking down carefully old unserviceable aluminium / copper point wiring (light, fan, socket or power) complete with fittings such as switches, sockets, ceiling rose, light fittings etc and making good the disturbed surfaces to match with existing surfaces complete all as specified and directed.
M&L for point wiring with single core copper conductor cable of size 1.5 Sq mm, PVC insulated, unsheathed, multistranded FRLS type, 1100V grade conforming to IS-694 drawn through in and including non-metallic rigid PVC conduit 25 mm dia medium grade with conduit accessories concealed in walls / floors / ceiling etc duly cutting chases / grooves and making good the disturbed surfaces to match with existing surfaces including GI modular flush boxes, modular white plate with frame of suitable sizes for mounting of modular switches, sockets and regulators etc and including 1.5 Sqmm PVC insulated, unsheathed, copper conductor cable, FRLS type multistranded, 1100V grade green in colour as earth continuity conductor connecting to earth dolly complete all as specified and directed for one light point controlled by one, one way modular switch.
All as per Sl item No. 64 above, one ceiling fan / exhaust fan point controlled by one, one way modular switch.
Sub main / circuit wiring with 2 x 1.5 sq mm single core PVC insulated and unsheathed FRLS cable, 1100 volts grade IS-694 marked with multistandard copper conductors and earth continuity wire with similar 1 x 1.5 sq mm cable (including connecting to earth dolly) drawn through and including non metallic rigid PVC conduit 25mm dia medium grade with conduit accessories recessed / concealed in walls duly cutting chases / grooves and making good disturbed surfaces as required at site for 5 Amps socket out let point controlled by one switch on independent board complete all as specified and directed.
Sub main / circuit wiring with 2 x 2.5 sq mm single core PVC insulated and unsheathed FRLS cable, 1100 volts grade IS-694 marked with multistandard copper conductors and earth continuity wire with similar 1 x 2.5 sq mm cable (including connecting to earth dolly) drawn through and including non metallic rigid PVC conduit 25mm dia medium grade with conduit accessories recessed / concealed in walls duly cutting chases / grooves and making good disturbed surfaces as required at site for 15 Amps socket out let point controlled by one switch on independent board and for high bay lights / Air circulators complete all as specified and directed.
Supply & fixing suitable size modular GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin, 5/6 A modular switch and 5/6A modular socket, connection etc. as required at site (for independant & same board) complete all as specified and directed.
Supply & fixing suitable size modular GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin, 15/16 A modular switch and 15/16A modular socket, connection etc. as required at site complete all as specified and directed.
S&F, ceiling rose surface bakelite three terminal complete all as specified and directed.
S&F, VTPN MCCB DB 8 way, confirmed to IEC 6149-3, 415V, 50Hz, AC, double door IP 43 protection suitable for MCCB 4 pole upto capacity 125 Amps as incomer and SP/TP MCB's as outgoings comprising of busbar, neutral bar, duly powder coated painting and fixed flush in wall and making good the disturbed surfaces to match with existing surface and making electrical connections using suitable sizes of copper thimbles / lugs including taking down old unserviceable item complete all as specified and directed.
S&F, MCCB 125 Amps, 4 pole, 16 KA, 415 V, AC 50 Hz, fixed type and making electrical connection complete all as specified and directed.
S&F, MCB DB TPN 6 way double door, 415 volts, IP-43 protection with neutral bar, earth bar, tinned copper bus bar and fixing in flush / recessed in wall and making necessary electrical connections complete all as specified and directed.
S&F, MCB DB SPN 8 way double door, 415 volts, IP-43 protection with neutral bar, earth bar, tinned copper bus bar and fixing in flush / recessed in wall and making necessary electrical connections complete all as specified and directed.
S&F, MCB TP&N 63 A, 415 V,10 KA, C curve type complete all as specified and directed.
S&F, MCB SP&N 40 A, 230 V,10 KA, C curve type complete all as specified and directed.
S&F, MCB SP 6-32 A, 230 V,10 KA, C curve type complete all as specified and directed.
S&F, triple pole and neutral enclosure with three pin and earth plug and socket including MCB TP 30 A, 10 KA, C curve, 415V type complete all as specified and directed.
M&L for sub main wiring with 4 runs of 10 sq mm of single core copper conductor cable PVC insulated, unsheathed, multistranded FRLS type, 1100V grade conforming to IS-694 drawn through in and including non-metallic rigid PVC conduit not less than 25 mm dia medium grade with conduit accessories concealed in walls / floors / ceiling etc duly cutting chases / grooves and making good the disturbed surfaces to match with existing surfaces including 2 runs of 10 Sq mm single core copper conductor cable, PVC insulated, unsheathed, multistranded FRLS type, 1100V grade green in colour as earth continuity conductor and connecting to earth dolly complete all as specified and directed. Note: 6 runs of 10 Sq.mm and PVC conduit will be measured and paid as one unit.
M&L for sub main wiring with 2 runs of 6 sq mm of single core copper conductor cable PVC insulated, unsheathed, multistranded FRLS type, 1100V grade conforming to IS-694 drawn through in and including non-metallic rigid PVC conduit not less than 25 mm dia medium grade with conduit accessories concealed in walls / floors / ceiling etc duly cutting chases / grooves and making good the disturbed surfaces to match with existing surfaces including 1 run of 6 Sq mm single core copper conductor cable, PVC insulated, unsheathed, multistranded FRLS type, 1100V grade green in colour as earth continuity conductor and connecting to earth dolly complete all as specified and directed Note: 3 runs of 6 Sq.mm and PVC conduit will be measured and paid as one unit.
M&L for sub main wiring with 2 runs of 4 sq mm of single core copper conductor cable PVC insulated, unsheathed, multistranded FRLS type, 1100V grade conforming to IS-694 drawn through in and including non-metallic rigid PVC conduit not less than 25 mm dia medium grade with conduit accessories concealed in walls / floors / ceiling etc duly cutting chases / grooves and making good the disturbed surfaces to match with existing surfaces including 1 run of 4 Sq mm single core copper conductor cable, PVC insulated, unsheathed, multistranded FRLS type, 1100V grade green in colour as earth continuity conductor and connecting to earth dolly complete all as specified and directed Note: 3 runs of 4 Sq.mm and PVC conduit will be measured and paid as one unit.
S&F, LED luminaire 36 Watts surface light fitting 600 mm x 600 mm, 36 watt, 220 Volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F, LED light fitting 20 Watt, 6500K, 2000 Lumens surface / ceiling mounted batten fitting with polycarbonate body enviormental friendly with better asthetic finish for soft light duly wired upto terminal block complete all as specified and directed.
S&F, LED highbay light fittings 120W, suitable for IP-66 with 110 lm/watt efficiency round highbay in PDC housing suitable for industrial application complete all as specified and directed. Note: (i) All necessary fixing / connecting arrangements of nuts, bolt, MS rod to be provided by the contractor without any extra payment from department. (ii) Quoted rate is to be deemed the charges of necessary boom fit.
S&F, Industrial wall mounted air circulator 600 mm sweep 1440 RPM, single speed, 3 blade, 230 volts, 50 Hz with 280 cfm all as per IS-2997-1964 including fixing arrangement on wall / column with necessary GI brackets, clamps, nuts, bolts and washers etc and making electrical connection by providing 3 core copper cable wire and complete all as specified and directed.
Taking down old existing ceiling fan 1200 mm sweep single phase, servicing and painting of ceiling fans including replacing clamps, rubber reel, cotter pins, and testing, refixing and connecting with necessary cable from ceiling rose or connector to fan and writing MES number with black paint complete all as specified and directed.
M&L for chemical earthing complete with 900 mm x 600 mm x 5 mm thick copper plate electrode buried direct in ground vertically not less than 4 mtrs deep below ground level with connected to copper strip of size 50 x 5.0 mm as earthing lead by means of bolts, nuts and brazing, check nut and washers all as directed to test point including necessary excavation and earth work (in any type of strata) and providing charcoal dust 250 Kgs, common salt 200 Kgs, magnesium sulphate 100 Kgs and all around the plate 15 cm depth and wide and upto 650 mm hight in continuous layers, balance pit will be filled with vegitable soil upto ground level including watering pipe GI medium grade of 20 mm dia and 50 mm dia pipe medium for earth strip protection upto 7.5 mtr, PCC (1:3:6) type C1 chamber cast iron chember frame, heavy duty funnel and RCC complete all as specified and directed.
Supplying & laying 25 mm x 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc as required (jointing shall be done by overlapping and with 2 sets copper nuts, bolts & washers etc, spaced at 50 mm) complete all as specified and directed.
Supply, install, testing & commissioning of package type air conditioning plant of capacity 17 TR, air cooled direct expansion floor mounted type of not less than 6800cfm complete with indoor units and outdoor unit (outdoor unit shall consist of 02 Nos compressors of 8.5 TR each) suitable for working on 3 Phase, 415 volts, 50 Hz with hermatically sealed scroll compressors operating on Eco-friendly R-407C refrigerant gas or with latest version to acheive inside temperature 23+2 degree centrigrade with RH of 55+5% comprising of standard fittings and components alongwith control wiring, safety devices, motors, condenser fan of adequate capacity, weather proof enclosure to protect electrical and electronic circuits and fan winding etc including microprocessor based controllers, dryers, thermostat valve, protection relays, condensing coil protection relay control panel and control cables from indoor unit outdoor unit etc, including civil works for foundation and platform for package unit with necessary bolts, nuts and washers etc as required complete all as specified and directed. Make: Bluestar / Voltas / Daikin / Carrrier.
Note: (i) Rate quoted by the contractor shall be deemed to included for leak testing with dry nitrogen gas to compete system for 48 hours and initial charging with refrigerant gas etc complete all as specified and as directed. (ii) Refrigerant gas will be measured and paid separately under relevant item of schedule.
M&L for fabrication of GI ducting of 22 SWG for plenium boxes with acoustic insulation complete all as specified and directed.
M&L for fabrication of GI ducting of 22 SWG for supply and air return including provision of angle iron channel for supporting complete all as specified and directed.
S&F, supply air diffuser made out of aluminium with powder coating of std size complete all as specified and directed.
S&F, return air grill as per suitable size complete all as specified and directed.
S&F, braze seamless hard copper pipe of size 7/8" for discharge line including elbow bends and sockets complete all as specified and directed.
S&F, braze seamless hard copper pipe of size 5/8" for liquid line including elbow bends and sockets complete all as specified and directed.
Supply and lay copper cable flexible 6 x 3 core complete all as specified and directed.
Supply and charge refrigerant gas 407C complete all as specified and directed.
S&F, volume control dampher complete all as specified and directed.
Supply, install, testing & commissioning step down transformer 500 KVA, 11000/433 V (at no load) AC, outdoor type, 4 wire, 3 phase, 50 Hz, core type copper wound, oil immersed, naturally cooled, oil natural, air natural (ONAN), with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector symbol. DYN-11 (Vector Group) with neutral brought out on secondary side (LV) and having tapping at +5% to -10% @ 2.5% HV side to be changed by means of hand operated off load tap changer gear. The maximum temperature rise should not exceed 45 degree C in oil and 55 degree C in HV/LV coil winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree C. The transformer shall be of EEL-2 conforming to IS-1180 - 2014 Amendment No. 1, 2, 3 & 4 after 29 Mar 2022 or with latest amendments and overload capacity of transformer as per IS-2026 with latest amendments including suitable PCC plinth & foundation for mounting the transformer as per manufacturer recommendation and shall comprise of the following: -
(a) One cable box on HT side (Primary side) consisting of 3 Nos porcelain bushing with copper rods, complete with nuts and washers with 02 Nos cable glands suitable for reception / taking out of XLPE insulated heavy duty armoured cables including gland, joint and jointing materials complete. (b) One cable box on LT side (Secondary side) consisting of 4 Nos porcelain bushing with copper rods, complete with nuts and washers with 02 Nos cable glands suitable for reception / taking out of PVC / XLPE insulated heavy duty armoured LTcables including gland, joint and jointing materials complete. (c) Oil conservator with filter type drain valve and oil level guage. (d) De-hydrating breather with first fill of dehydrating agent (silica gel). (e) Explosive vent. (f) Thermometer pocket on tank cover. (g) One No 100 mm dia, dial type thermometer, vapour pressure type having range 0-120 degree C with metal guard having maximum perimeter reading temparature indicator with resisting device for transformer.
(h) Two earthing terminals on tank cover to facilitate fixing of 32 x 6 mm galvanized iron earth strip for earthing of neutral and body. (j) Rating plate and terminal marking plate. (k) Oil level guage. (l) Oil drain filler valve. (m) Lifting lugs. (n) Oil filling hole with cap / plug with connecting plate complete. (o) Air release valve plug. (p) Four plain solid cast steel detachable rollers. (q) Extra bushing for neutral, outside the LT cable box for providing independent earthing for neutral. (r) First filling of new and unused transformer oil IS-335/93 (fourth revision) marked filtered and tested upto 40 KV dielectric strength at 2.5 mm air gap between testing electrodes. (s) One danger notice board having conventional danger sign of skull with bones in painted in red colour. Note: (i) Certification of electric strength shall be submitted by the contractor after filling the oil. (ii) Pole and connected supporting members shall be measured and paid separately under respective items of this schedule.
Supply, install, testing & commissioning 11KV 3 way Ring Main Unit (RMU) 630Amps, 20KA/3 Sec outdoor type extensible type comprising of 01 incomer and 02 outgoings with fixed VCB and 01 No air insulated Bus PT panel coupled with SF6 RMU. All light parts Bus Bars VCB connection of RMU max two modules shall be enclosed in single tank duly welded stainless steel tank of 3 mm thickness having IP 67 degree of protection filled with gas as insulation with leakage rate less than 0.1 % per year tested as per IEC 62271 - 200. RMU shall be complete with all accesories such as ring core CTs self powered micro process based numerical protection relay for O/C, S/C, E/F, cable support, all front cable terminations, mechanical indication for breaker ON / OFF / Trip / Spring charged, Mono meter as per IEC Standards 62271-200, 60056, 60129,60265, 60298, 60420, 60529 and 60694. Altitude of installation upto 1000 mtrs as per IEC 60120. Bushing voltage type top mounted outside the tank of external connection of external busbar complete with power pack and battery back up including any civil works as required complete all as specified and directed. The each VCB module should consist of following accessories: -
(a) 630 A, 350 MVA VCB module for making and breaking fault current along with OFF load isolator in series for isolation purpose and integral series earth switchof full making capacity. (b) Short time current - 20 KA/3 Sec (c) Making capacity - 50 KA (d) Auxiliary Contacts - 1 NO + 01 NC (e) Minimum width - 300 mm for compact design (f) Minimum depth - 900mm for compact design (g) Impulse voltage withstand voltage - 75 KV (h) Nominal operating gas pressure - 1.5-ABS (h) Front cover Mechanism - IP 2 X (j) Cable cover - 4X (k) Auto degree of protection - IP 54 (l) Internal arc type tested (m) 110/24 volts DC motorised spring charging mechanism for breaker operation (n) Push button for breaker ON/OFF (o) Cable box for front termination of the cable suitable upto 3 core 300 Sqmm, 11 KV XLPE Cable (p) Push ON type right angle Boots.
(q) Self powered micro processor based relay 3 O/C 01 E/F with low and high set for over current and earth fault. Realy should have facility to display the maximum loaded current also. Relay should be flush mounted for incoming and out going VCB to trip the breaker from remote commands without shunt trip coil alongwith HMI Screen interface. (r) Panel mounted 11 KV ring core CTs IP 10 for protection as per IEC 50185 (s) Panel mounted 11 KV ring core CTs (Ratio 50/5 or 50/1 for incoming and 20/5 or 20/1 for out gaoing). Classs 1.0 as metering as per IEC 60185. (t) LV compartment mounted on top consisting of digital multi functionmeter (A, V, KW, KVA, F, PF) type rishabh, Rish 3430/conserve EM 6400 in outging and incoming VCB (u) Indication lamp (v) Suitable cable bushing for front cable terminations (w) Arc proof cable covers with self interlcking mechanism with earth switch (x) Cappacitieve voltage indication fixed type system as per IEC 61243 (y) Mechanical indication for breaker ON, OFF, earth, Trip, spring charge-discharge.
Supply, laying & testing HT cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) earthed grade with stranded aluminium conductor 11000 volts grade of size 120 Sqmm 3 core conforming to IS-7098 Part-II complete all as specified and directed. Note: Excavation, earthwork, sand cushioning, cable covers, pipe for cable protection to be measured and paid seperately.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor conforming to IS-7098 Part-I of size 400 Sq mm 3½ core complete all as specified and directed.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor conforming to IS-7098 Part-I of size 95 Sq mm 3½ core complete all as specified and directed.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor conforming to IS-7098 Part-I of size 50 Sq mm 3½ core complete all as specified and directed.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor conforming to IS-7098 Part-I of size 25 Sq mm 3½ core complete all as specified and directed. Note for Sl item Nos. 102 to 105: Excavation, earthwork, sand cushioning, cable covers, pipe for cable protection to be measured and paid seperately.
Supplying & making indoor cable end jointing with cast resin compound, including lugs and other jointing material for 120 sqmm of 3 core, XLPE aluminium conductor cable of 11 KV grade as required complete all as specified and directed.
S&F, insulating rubber mat of size 2 mtr x 1 mtr of 19mm thick ISI marked complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6.3 mm thick buried in ground vertically to a depth not less than 2.25 metre below normal ground level, normal with top edge of earth plate not less than 1.5 metre below normal ground level, earth plate connected to a galvanised earth lead of size 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in DSR specifications connected to earth test point all as specified or indicated including testing on completion with and including 40 mm bore light grade GI protection pipe 7.5 metres long or upto equipment including PCC 1:2:4 pit with pre cast RCC 1:2:4 type B1 cover 40 mm thick reinforced with 6mm dia MS bars @ 100mm both ways with lifting hook made out of 6mm dia MS bars watering arrange,ent with funnel wire, common salt and charcoal filling, necessary excavation and earth work in any type of soil complete all as specified and directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/GI pipe or fixed to poles or any other indicated situation for loop earthing etc as required of GI strip 32 x 6 mm complete all as specified and as directed
M&L for cutting of black top cover of existing road upto 1 mtr depth and 60 cm wide for laying of UG cable and pipe line, refilling and making good after laying UG cable and pipe line with PCC 1:3:6 uptp 30 cm from top of the road surface complete all as directed by Engineer-in-Charge.
M&L for boring under roads, pavement hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
(a) ACB 4 pole, 800 Amps rating manual draw out type having short curcuit breaking capacity of 50KA at 415 volts, (Ics =100% Icu), confirming to IS/IEC 60947-2&3, microprocessor base ET trip systems with thermal memory, with fully rated neutral with inbuilt protections, equipped with overload, short circuit, instaneous and earth fault protection, vertical termination, 01 No. electrical fault indicator contact, 01 No auxilary contact block (OF) with 2 c/o contacts with safety shutters onhasis and door sealing frame, complete with all accessories as specified and directed-01 No. (b) MCCB 3 pole 415V, 250 Amps, 50 Hz thermal magnetic release and Ics=100% Icu with rupturing capacity 36 KA adjustable overload min 70-100% - 03 Nos. (c) MCCB 3 pole 415V, 160 Amps, 50 Hz thermal magnetic release and Ics=100% Icu with rupturing capacity 25 KA adjustable overload min 70-100% - 02 Nos. (d) MCCB 3 pole 415V, 100 Amps, 50 Hz thermal magnetic release and Ics=100% Icu with rupturing capacity 25 KA adjustable overload min 70-100% - 02 Nos.
(e) Panel mounted type digital multifunctional energy meter A, V, KW, PF, CT operated, LT 3 phase, 4 wire including CT ratio 400/5 - 01 No (f) LED indiating lamps set RYB-01 Set
Excavation in trenches n exc 1.5m wide and n exc 10 sq m on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and directed.
Returing, filling in, including spreding, leveling, watering and well ramming in layer n exc 25 cm as in soil complete all as specified and directed.
Removing excavated soil to a distance n exc 50 m and deposting where directed at a level n exc 1.5 m above the starting point complete all as specified and directed.
M&L for sand filing in cable trenches for cushioning of cables upto 23cm and punned down to 18cm complete all as specified and directed. Note: Punned thickness of the sand will be measured and paid.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type I with flat, size 300mm x 180mm x 40mm complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type I, flat, size 250mm x 150mm x 40mm complete all as specified and directed.
S&F, GI tubing light garde 100 mm bore in trenches / road / plinth fixing alongwith pole / wall for protection of cable complete all as specified and directed.
S&F, GI tubing light garde 80 mm bore in trenches / road / plinth fixing alongwith pole / wall for protection of cable complete all as specified and directed.
S&F, GI tubing light garde 50 mm bore in trenches / road / plinth fixing alongwith pole / wall for protection of cable complete all as specified and directed.
B5BUILDING SOLUTIONS
Lucky Enterprises
Sai Ram Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .