| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.6 LAccepted-AOC 12 173 MOTTUR GONUR POST METTUR DAM SALEM 636 404 | METTUR | SALEM | TAMIL NADU | 636404 | L1 | Accepted-AOC L1 |
| Sl No | Description | Qty | Unit | PKR CONTRACTORS L1 |
|---|---|---|---|---|
| 1.00Work contract schedule | ||||
| 1.01 | Excavation of pole pit upto 27' (8.0 m) Pole by using JCB or manual | 70 | Each pit | 390 ₹27,300 Lowest |
| 1.02 | Excavation of pole pit for 30' RCC pole /9.00m PSC pole by using JCB or manual | 50 | Each pit | 475 ₹23,750 Lowest |
| 1.03 | Excavation Stay pit 4.5' to 5' depth by using JCB or manual | 75 | Each pit | 390 ₹29,250 Lowest |
| 1.04 | Hard rock requires blasting | 10 | Each pit | 1,200 ₹12,000 Lowest |
| 1.05 | Hard rock without blasting (Where houses are located) | 10 | Each pit | 1,200 ₹12,000 Lowest |
| 1.06 | Erection of PSC/ RCC poles upto 8.00m. (27') crane or manual | 80 | Each pole | 475 ₹38,000 Lowest |
| 1.07 | Erection of PSC/ RCC poles/Metal poles above 8.00m by using JCB or maual | 60 | Each pole | 550 ₹33,000 Lowest |
| 1.08 | Erection of stay set complete | 75 | Each set | 210 ₹15,750 Lowest |
| 1.09 | Fixing of HT 'V' cross arms all type channel cross arm guarding croos arm | 25 | Each | 150 ₹3,750 Lowest |
Tender Value
₹10 L
EMD Value
₹10,000
Closing Date
19 Aug 2025, 11:00 amClosed
SE/MEDC/METTUR
O/o SE/MEDC/METTUR
Works Contract in Kunjandiyur Section
2025_EB_588618_1
SE/MEDC/AEE/MM/MTR/Spec No.016/25-26
Open Tender
Electrical Works
Works
365 days
Mettur EDC
EMD and documents as per BQR condition
2 documents required · 2 mandatory
₹0
₹10,000
Yes
10 Oct 2025
4 Aug 2025
19 Aug 2025
4 Aug 2025
19 Aug 2025
4 Aug 2025
4 Aug 2025 - 19 Aug 2025
Amount
Work contract schedule
Excavation of pole pit upto 27' (8.0 m) Pole by using JCB or manual
Excavation of pole pit for 30' RCC pole /9.00m PSC pole by using JCB or manual
Excavation Stay pit 4.5' to 5' depth by using JCB or manual
Hard rock requires blasting
Hard rock without blasting (Where houses are located)
Erection of PSC/ RCC poles upto 8.00m. (27') crane or manual
Erection of PSC/ RCC poles/Metal poles above 8.00m by using JCB or maual
Erection of stay set complete
Fixing of HT 'V' cross arms all type channel cross arm guarding croos arm
Fixing of LT 3 -phase X arm
Fixing of LT 1 -phase X arm
Fixing of HT/LT TI Fittings
Fixing of HT Pin Insulators - 22 KV
Fixing of HT 11 KV Strain disc
Fixing of LT Pin insulators
Fixing of LT Shackle
Fixing of Alu Knob
Paving , Stringing, Binding & Jumpering of ACSR 7/3.35 & AAAC 7/3.15 mm
Paving , Stringing, Binding & Jumpering of ACSR 7/2.59 mm & ACSR 7/2.11 mm AAC 7/2.50
Erection of Single Pole Transformer structure complete in all respects with wiring, Earthing, fixing of open type fuse units, HT/LT LAS and jumpering 3 Nos. Earth pit with collar including painting of metal parts, structure poles, fixing of tapping channel, transformer bed structure including concreting (Except erection of Transformer) Per
Erection of D.P. structure with AB switch, top channel, cross bracing, earthing, painting, providing stay including concreting
Erection of new transformer all capacity with jumpering
Loading or unloading of transformer above 200 KVA
Transport of poles/Materisal/ conductor and other Materisal below 8 km plains
Loading of Materisal
unloading of Materisal
Loading of pole (7.5/8.0/9.14M)
unloading of pole (7.5/8.0/9.14M)
Loading of poles above 9.0 M
unloading of pole above 9.0 M
Transporting of poles from road side to pole pit including loading and unloading of poles by using JCB or manula up to 100 m
Transporting of poles from road side to pole pit including loading and unloading of poles by using JCB or manula beyond 100 m
Earthing of pole with coil earthing including burying looping and binding
Alteration of Back clamp
Alteration of Stay clamp
Drilling of Holes channel onl 3/4 &1" per hole
Cutting of flat
Cutting of channel
Cutting of angle
Releasing of grills form RCC poles
Dismandilling of PSC/RCC pole upto 8.00m.(27') crane or manual
Dismandilling of V cross arms all type channel cross arm guarding cross arm
Dismandilling LT 3 -phase cross arm
Dismandilling LT 1 -phase cross arm
Dismandilling HT/LT TI Fittings
Dismandilling of 22 KV Strain disc
Dismandilling 22 KV Pin Insulators
Dismandilling LT Shackle
Dismandilling LT Pin Insulators
Dismandilling Alu Knob
Releasing of single -phase Service and re-fixing
Releasing of 3 -phase Service and (upto 50 HP) re-fixing
Dismandilling of stay set
Re-sagging ACSR 7/3.35mm /AAAC 3.15 mm Rabbit conductor
Re-sagging ACSR 7/2.59mm /AAAC 2.50 mm Weasel and ACSR 7/2.11mm conductor
G.S.T. @18% should be Entered by the Bidder
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .