Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.2 LQualified Make: havells
Model: Make havells 1C x 95 sq mm LT XLPE Al armoured 6 BHATINDA PUNJAB 151001 INDIA | BATHINDA | PUNJAB | 151001 | Make: havells
Model: Make havells 1C x 95 sq mm LT XLPE Al armoured | L1 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
11 Oct 2018, 4:00 pmClosed
power cable for direct burial xlpe ugac cable
power cable for direct burial xlpe ugac cable Average Turn Over of Last 3 Years 2 Lakh (s) Experience with Gov. Required 5 Year (s) Power Cable For Direct Burial Xlpe Ugac Cable ( 100 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Mode of Buying Through bidding only * Size of Cable (in Sq.mm) 95.0 95.0 Number of cores (nos) 1 1 Cable Type Cross linked polyethylene and XLPE insulated PVC outer sheathed cable with aluminum conductor suitable for rated voltage at 1100 volts grade and conforming to IS: 7098 Part-1 1988 with amendment number 1 and 2 and 3 Reaffirmed 2005 Cross linked polyethylene and XLPE insulated PVC outer sheathed cable with aluminum conductor suitable for rated voltage at 1100 volts grade and conforming to IS: 7098 Part-1 1988 with amendment number 1 and 2 and 3 Reaffirmed 2005 1/8 BIS marked yes * BIS certificate number 3088459 * Armouring Galvanised round steel wire armoured Galvanised round steel wire armoured
Galvanised steel Strip armoured
unarmoured Armouring Type single wire or strip armouring single wire or strip armouring
Double wire or strip armouring shape of conductor Solid Solid
Stranded
Stranded and Shaped CONSTRUCTIONAL Number of armouring strip/wire for each size of cable 15 * size of armouring strip/wire for each size of cable 1.6 * Material of conductor Aluminium EC Grade * Weight of finished cable per meter 0.59 * In addition to marking requirements as per relevant specification
sequential marking for length
Size of the cable
Type of the cable and Drum Number shall be embossed on every metre of the cable yes * standard cable length on a drum 250 meter for size 240sqmm and above. * Part length which can be supplied by seller (meter) 1 * cable to be supplied on wooden drums conforming to IS: 10418/82 with latest amendments. yes * Quantity supplied shall not be more than the ordered quantity. yes * CERTIFICATIONS Availability of Type test report from Central government/NABL/ILAC accridiated laoratory to prove conformity to the specification for yes * 2/8 minimum and maximum ratings. Type Test Certificate No. CPRIRTLCL2014T290 * Type Test Certificate date 24.03.15 * Name of Lab Central Power Research Institute * Address of Lab 3-A
Institutional Area
Sector -62
Noida-201309 * Test Report to be furnished to the buyer on demand yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 JAI KRISHAN MEENA 125055
GE (AIR FORCE) SIRSA 100 30 Power Cable For Direct Burial Xlpe Ugac Cable ( 100 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Mode of Buying Through bidding only * Size of Cable (in Sq.mm) 120.0 120.0 Number of cores (nos) 1 1 Cable Type Cross linked polyethylene and XLPE insulated PVC outer sheathed cable with aluminum conductor suitable for rated voltage at 1100 volts grade and conforming to IS: 7098 Part-1 1988 with amendment number 1 and 2 and 3 Reaffirmed 2005 Cross linked polyethylene and XLPE insulated PVC outer sheathed cable with aluminum conductor suitable for rated voltage at 1100 volts grade and conforming to IS: 7098 Part-1 1988 with amendment number 1 and 2 and 3 Reaffirmed 2005 3/8 BIS marked yes * BIS certificate number 3088459 * Armouring unarmoured Galvanised round steel wire armoured
Double wire or strip armouring shape of conductor Stranded Solid
Stranded and Shaped CONSTRUCTIONAL Number of armouring strip/wire for each size of cable 15 * size of armouring strip/wire for each size of cable 1.6 * Material of conductor Aluminium EC Grade * Weight of finished cable per meter 0.56 * In addition to marking requirements as per relevant specification
Type of the cable and Drum Number shall be embossed on every metre of the cable yes * standard cable length on a drum 250 meter for size 240sqmm and above. * Part length which can be supplied by seller (meter) 1 * cable to be supplied on wooden drums conforming to IS: 10418/82 with latest amendments. yes * Quantity supplied shall not be more than the ordered quantity. yes * CERTIFICATIONS Availability of Type test report from Central government/NABL/ILAC accridiated laoratory to prove conformity to the specification for yes * 4/8 minimum and maximum ratings. Type Test Certificate No. CPRIRTLCL2014T290 * Type Test Certificate date 24.03.15 * Name of Lab Central Power Research Institute * Address of Lab 3-A
GE (AIR FORCE) SIRSA 100 30 Power Cable For Direct Burial Xlpe Ugac Cable ( 100 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Mode of Buying Through bidding only * Size of Cable (in Sq.mm) 400.0 400.0 Number of cores (nos) 1 1 Cable Type Cross linked polyethylene and XLPE insulated PVC outer sheathed cable with aluminum conductor suitable for rated voltage at 1100 volts grade and conforming to IS: 7098 Part-1 1988 with amendment number 1 and 2 and 3 Reaffirmed 2005 Cross linked polyethylene and XLPE insulated PVC outer sheathed cable with aluminum conductor suitable for rated voltage at 1100 volts grade and conforming to IS: 7098 Part-1 1988 with amendment number 1 and 2 and 3 Reaffirmed 2005 5/8 BIS marked yes * BIS certificate number 3088459 * Armouring unarmoured Galvanised round steel wire armoured
Stranded and Shaped CONSTRUCTIONAL Number of armouring strip/wire for each size of cable UNARMOURED * size of armouring strip/wire for each size of cable UNARMOURED * Material of conductor Aluminium EC Grade * Weight of finished cable per meter 1.519 * In addition to marking requirements as per relevant specification
Type of the cable and Drum Number shall be embossed on every metre of the cable yes * standard cable length on a drum 250 meter for size 240sqmm and above. * Part length which can be supplied by seller (meter) 1 * cable to be supplied on wooden drums conforming to IS: 10418/82 with latest amendments. yes * Quantity supplied shall not be more than the ordered quantity. yes * CERTIFICATIONS Availability of Type test report from Central government/NABL/ILAC accridiated laoratory to prove conformity to the specification for yes * 6/8 minimum and maximum ratings. Type Test Certificate No. CPRIRTLCL2014T290 * Type Test Certificate date 24.03.15 * Name of Lab Central Power Research Institute * Address of Lab 3-A
GE (AIR FORCE) SIRSA 100 30
680128
GEM/2018/B/96373
power cable for direct burial xlpe ugac cable,power cable for direct burial xlpe ugac cable,power ca
30 days
Haryana; Sirsa
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| power cable for direct burial xlpe ugac cable | - | - | - |
| power cable for direct burial xlpe ugac cable Average Turn Over of Last 3 Years 2 Lakh (s) Experience with Gov. Required 5 Year (s) Power Cable For Direct Burial Xlpe Ugac Cable ( 100 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Mode of Buying Through bidding only * Size of Cable (in Sq.mm) 95.0 95.0 Number of cores (nos) 1 1 Cable Type Cross linked polyethylene and XLPE insulated PVC outer sheathed cable with aluminum conductor suitable for rated voltage at 1100 volts grade and conforming to IS: 7098 Part-1 1988 with amendment number 1 and 2 and 3 Reaffirmed 2005 Cross linked polyethylene and XLPE insulated PVC outer sheathed cable with aluminum conductor suitable for rated voltage at 1100 volts grade and conforming to IS: 7098 Part-1 1988 with amendment number 1 and 2 and 3 Reaffirmed 2005 1/8 BIS marked yes * BIS certificate number 3088459 * Armouring Galvanised round steel wire armoured Galvanised round steel wire armoured | - | - | - |
| Galvanised steel Strip armoured | - | - | - |
| unarmoured Armouring Type single wire or strip armouring single wire or strip armouring | - | - | - |
| Double wire or strip armouring shape of conductor Solid Solid | - | - | - |
| Stranded | - | - | - |
| Stranded and Shaped CONSTRUCTIONAL Number of armouring strip/wire for each size of cable 15 * size of armouring strip/wire for each size of cable 1.6 * Material of conductor Aluminium EC Grade * Weight of finished cable per meter 0.59 * In addition to marking requirements as per relevant specification | - | - | - |
| sequential marking for length | - | - | - |
| Size of the cable | - | - | - |
| Type of the cable and Drum Number shall be embossed on every metre of the cable yes * standard cable length on a drum 250 meter for size 240sqmm and above. * Part length which can be supplied by seller (meter) 1 * cable to be supplied on wooden drums conforming to IS: 10418/82 with latest amendments. yes * Quantity supplied shall not be more than the ordered quantity. yes * CERTIFICATIONS Availability of Type test report from Central government/NABL/ILAC accridiated laoratory to prove conformity to the specification for yes * 2/8 minimum and maximum ratings. Type Test Certificate No. CPRIRTLCL2014T290 * Type Test Certificate date 24.03.15 * Name of Lab Central Power Research Institute * Address of Lab 3-A | - | - | - |
| Institutional Area | - | - | - |
| Sector -62 | - | - | - |
| Noida-201309 * Test Report to be furnished to the buyer on demand yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 JAI KRISHAN MEENA 125055 | - | - | - |
| GE (AIR FORCE) SIRSA 100 30 Power Cable For Direct Burial Xlpe Ugac Cable ( 100 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Mode of Buying Through bidding only * Size of Cable (in Sq.mm) 120.0 120.0 Number of cores (nos) 1 1 Cable Type Cross linked polyethylene and XLPE insulated PVC outer sheathed cable with aluminum conductor suitable for rated voltage at 1100 volts grade and conforming to IS: 7098 Part-1 1988 with amendment number 1 and 2 and 3 Reaffirmed 2005 Cross linked polyethylene and XLPE insulated PVC outer sheathed cable with aluminum conductor suitable for rated voltage at 1100 volts grade and conforming to IS: 7098 Part-1 1988 with amendment number 1 and 2 and 3 Reaffirmed 2005 3/8 BIS marked yes * BIS certificate number 3088459 * Armouring unarmoured Galvanised round steel wire armoured | - | - | - |
| Double wire or strip armouring shape of conductor Stranded Solid | - | - | - |
| Stranded and Shaped CONSTRUCTIONAL Number of armouring strip/wire for each size of cable 15 * size of armouring strip/wire for each size of cable 1.6 * Material of conductor Aluminium EC Grade * Weight of finished cable per meter 0.56 * In addition to marking requirements as per relevant specification | - | - | - |
| Type of the cable and Drum Number shall be embossed on every metre of the cable yes * standard cable length on a drum 250 meter for size 240sqmm and above. * Part length which can be supplied by seller (meter) 1 * cable to be supplied on wooden drums conforming to IS: 10418/82 with latest amendments. yes * Quantity supplied shall not be more than the ordered quantity. yes * CERTIFICATIONS Availability of Type test report from Central government/NABL/ILAC accridiated laoratory to prove conformity to the specification for yes * 4/8 minimum and maximum ratings. Type Test Certificate No. CPRIRTLCL2014T290 * Type Test Certificate date 24.03.15 * Name of Lab Central Power Research Institute * Address of Lab 3-A | - | - | - |
| GE (AIR FORCE) SIRSA 100 30 Power Cable For Direct Burial Xlpe Ugac Cable ( 100 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Mode of Buying Through bidding only * Size of Cable (in Sq.mm) 400.0 400.0 Number of cores (nos) 1 1 Cable Type Cross linked polyethylene and XLPE insulated PVC outer sheathed cable with aluminum conductor suitable for rated voltage at 1100 volts grade and conforming to IS: 7098 Part-1 1988 with amendment number 1 and 2 and 3 Reaffirmed 2005 Cross linked polyethylene and XLPE insulated PVC outer sheathed cable with aluminum conductor suitable for rated voltage at 1100 volts grade and conforming to IS: 7098 Part-1 1988 with amendment number 1 and 2 and 3 Reaffirmed 2005 5/8 BIS marked yes * BIS certificate number 3088459 * Armouring unarmoured Galvanised round steel wire armoured | - | - | - |
| Stranded and Shaped CONSTRUCTIONAL Number of armouring strip/wire for each size of cable UNARMOURED * size of armouring strip/wire for each size of cable UNARMOURED * Material of conductor Aluminium EC Grade * Weight of finished cable per meter 1.519 * In addition to marking requirements as per relevant specification | - | - | - |
| Type of the cable and Drum Number shall be embossed on every metre of the cable yes * standard cable length on a drum 250 meter for size 240sqmm and above. * Part length which can be supplied by seller (meter) 1 * cable to be supplied on wooden drums conforming to IS: 10418/82 with latest amendments. yes * Quantity supplied shall not be more than the ordered quantity. yes * CERTIFICATIONS Availability of Type test report from Central government/NABL/ILAC accridiated laoratory to prove conformity to the specification for yes * 6/8 minimum and maximum ratings. Type Test Certificate No. CPRIRTLCL2014T290 * Type Test Certificate date 24.03.15 * Name of Lab Central Power Research Institute * Address of Lab 3-A | - | - | - |
| GE (AIR FORCE) SIRSA 100 30 | - | - | - |
Exempted
12 Oct 2018
1 Oct 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_680128.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .