Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹9.6 L+₹6,093 (0.64%)Rejected-Finance D NO 32 1 211 2 BOWDARA ROAD VISAKHAPATNAM 530004 | VISAKHAPATANAM | ANDHRA PRADESH | 530004 | L2 | Rejected-Finance Being other than lowest tenderer | |
| 3 | L3₹10.6 L+₹1.1 L (11.1%)Rejected-Finance NO 14 M C RAJA STREET MITTANAMALLI I A F AVADI CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | L3 | Rejected-Finance Being other than lowest tenderer | |
| 4 | L4₹11.6 L+₹2.1 L (22.4%)Rejected-Finance D 3 7TH BLOCK JAIN GREEN ACRES DHARGA ROAD ZAMIN PALLAVARAM CHENNAI 600043 | CHENNAI | CHENNAI | TAMIL NADU | 600043 | L4 | Rejected-Finance Being other than lowest tenderer | |
| 5 | L5₹12.5 L+₹3.0 L (31.4%)Rejected-Finance HOUSE NO 105 PANTHEERMA VILLAI NEAR NELLIKKAVILLAI CSI CHURCH VELLAYAMBALAM VENCODE P O KANYAKUMARI DIST TAMIL NADU 629 171 | VENCODE | KANYAKUMARI | TAMIL NADU | 629171 | L5 | Rejected-Finance Being other than lowest tenderer |
Tender Value
₹17 L
EMD Value
₹34,000
Closing Date
26 May 2023, 6:00 pmClosed
Shri. Narinder Singh, IDSE, SE(SAG)
COMMANDER WORKS ENGINEERS CHENNAI PALLAVAN SALAI CHENNAI 600 002
PROVN OF WALK-IN-COOLER WITH INTERNAL ELECTRIFICATION WORKS AT MH UNDER GE STM CHENNAI
2023_MES_592122_1
86536
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
STM CHENNAI
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE STM CHENNAI
₹34,000
Yes
15 Jun 2023
28 Apr 2023
2 Jun 2023
28 Apr 2023
26 May 2023
12 May 2023
28 Apr 2023 - 5 May 2023
Amount
BOQ UPLOADED ON 28 APR 2023
Supply, installation, testing and commissioning of Walk-in-Cooler cold room for Storage of approx size (12 x10 x 8)' (Outer to outer Dimensions) (Approx 5 Ton capacity) with wall and ceiling panel made out of Pre painted GI sheet filled with 60 mm PUF insulation, anti skid GI flooring on 60 mm PUF, with door manually operated , digital temperature indicator, Air cooled medium temperature split unit of 3 HP rating with Hermetic/Scroll Compressors working on R -22/R - 410A refrigerants to maintain temperature of 4 +/- 2 degree Centigrade at an ambient temperature of 30 degree centigrade complete all as per the details mentioned in Particular specifications Note:- (i) The installation of Walk in cooler shall be carried out under supervision of manufacturer auth rep. (ii) Cost for any civil work i.e. foundation and any minor nature of work as required for installation of walk in cooler in the existing building shall deemed to be in included in quoted rate. (iii) The cost of Comprehensive warranty / product warranty of (12 Months) shall deemed to be in included in quoted rate and the contractor has to submit the same from the Manufacturer before claiming any payment.
MCCB 63 Amps four pole with breaking capacity 16 KA 415 volts fixing to the existing LT panel board with and inclduing necessary modification to existing LT Panel Board of CRCA sheet to match with existing size and height complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation of stays, laying cables etc and getting out in hard/dense soil all as specified and as directed.
Labour only for spread in trenches, sieving sand retrived from excavated soil including cleaning, spreading, levellng, punning for laying /cushioning of cable all as specified and as directed. Note: Punning thickness shall be measured and paid.
Removing excavated material/ surplus soil not exceeding 50 metres and depositing where directed at a level not exceeding 1.5 metre above the starting point all as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm using excavated soil all as specified and directed.
Precast concrete electrical cable cover, Class LV, flat of size (250 x 150 x 40) mm complete all as per IS 5820 : 1970 and as directed by Eng-in-Charge.
GI tubing 'Light grade' of size 50mm bore for cable protection/ earth strip protection with all fittings and laid in trench or in floor complete all as specified and directed by Eng-in-Charge
Supplying, laying, connecting, testing and commissioning of XLPE insulated, sheathed, screened, PVC bedded with galvanised steel strip or wire armoured electrical power Cable 4 Core 35 Sqmm size with multi stranded aluminium conductor 1100 volts grade of earthed system complete all as specified and directed by Eng-in-Charge.
Load line distribution board, TPN vertical, 4 way double door type, fixed on wall semi flush, with incoming MCCB 4 poles 63 Amps, 16 KA bus bars, neutral link, blanking plates complete all as specified and as directed.
MCB three pole and neutral (MCB TPN) 440 volts of capacity 63 Amps, 10 KA C curve including connecting and testing complete all as specified and as directed.
MCB three pole and neutral (MCB TPN) 440 volts of capacity 32-40 Amps, 10 KA C curve including connecting and testing complete all as specified and as directed.
S.M.ELECTRICALS
SAMYDOSS CONSTRUCTIONS
lakshmibuilders
DJ Group
Sri Lakshmi and Company
rc enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .