| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 LAccepted-AOC 28 1 THURAIYUR PUTHUCHINNAKAVUR METTUR DAM 636401 | METTUR DAM | SALEM | TAMIL NADU | 636401 | L1 | Accepted-AOC Work awarded | |
| 2 | L2₹5.8 L+₹30,304 (5.47%)Rejected-AOC ERIKKADU THERMAL POST METTUR DAM 636 406 | METTUR DAM | SALEM | TAMIL NADU | 636406 | L2 | Rejected-AOC Rejected due to L2 | |
| 3 | L3₹6.1 L+₹57,437 (10.4%)Rejected-AOC | L3 | Rejected-AOC Rejected due to L3 | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 5 | Not Admitted-Fee/PreQual/Technical 002 1 NATHAKADU SRI MAHALAKSHMI DYEING PRINTING MILLS CAMPUS BHAVANI MAIN ROAD ERODE 638004 | ERODE | ERODE | TAMIL NADU | 638004 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | NVS and Co L3 | CMR ENGINEERING WORKS L2 | SRI SELVALAKSHMI ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00 | Earth work excavation in hard stiff clay, stiff block cotton, hard red earth, shales, murram, gravel, stoney earth, earth mixed with small size boulders, hard gravely soil with an initial lead of 10m and lift of 2 m including all lead lift etc., complete. | 17 | Cum | 200 ₹3,400 | 130 ₹2,210 Lowest | 226.78 ₹3,855.26 |
| 2.00 | Plain cement concrete 1:3:6 using 40mm size graded HBG stone including cost of all materials labour, curing charges, lead lift etc., complete. | 2 | Cum | 5,400 ₹10,800 | 5,100 ₹10,200 | 5,010 ₹10,020 Lowest |
| 3.00 | Brick work in C.M. 1:3 using class II chamber burnt bricks including, cost of cement, all materials, labour, curing, all leads and lifts, as per standard specification etc., complete. | 1 | Cum | 6,400 ₹6,400 | 6,000 ₹6,000 | 5,573 ₹5,573 Lowest |
| 4.00 | Supply and Installation of Ocean septic tank size BR-20 of standard make and size including cost of transport charges, labour charges for fixing in position, fixing of all PVC joineries, lead, lift, etc. as directed by the Engineer incharge. | 1 | Nos | 1,05,000 ₹1,05,000 | 1,00,000 ₹1,00,000 | 94,727 ₹94,727 Lowest |
| 5.00 | Supplying and filling in foundation with M-sand well watered, rammed and consolidated etc., complete complying with standard specification and as directed by the departmental officers. | 4.35 | Cum | 2,000 ₹8,700 | 1,500 ₹6,525 Lowest | 1,823 ₹7,930.05 |
| 6.00 | Plastering with CM 1:3 12 mm thick including cost of cement including labour, curing, all leads and lifts etc., complete as per standard specification. | 2.3 | Sqm | 250 ₹575 | 220 ₹506 Lowest | 261 ₹600.3 |
| 7.00 | Plastering with CM 1:5, 12mm thick for brick works including cost of all materials, labour, curing charges, all lead & lift etc., complete. | 6 | Sqm | 250 ₹1,500 | 230 ₹1,380 Lowest | 249 ₹1,494 |
| 8.00 | Supplying and Erection of Precast Toilet POD (Cellcon make) with concrete grade M40SCC, Inner Dimension of POD 1800mm x 1200mm, wall thickness 75mm Base slab thickness 150mm, Roof joineries such as FRP door, fired louver, plumbing fittings such as a wall mounted wash basin floor mounted European water closet, Electrical wiring work complete excluding electrical fittings, painting etc, complete including cost of all materials, labour charges, lead, lift, etc. complete. | 2 | Nos | 1,80,000 ₹3,60,000 | 1,75,000 ₹3,50,000 | 1,62,540 ₹3,25,080 Lowest |
| 9.00 | Supplying and fixing of 25mm dia UPVC pipe 10Kg/cm2 (Shall thickness 2 to 3mm) for water supply line, including cost of pipe, bend, elbow, labour for cutting, threading and fixing in position, testing all materials, solution, lead, lift etc., complete. | 20 | Rm | 330 ₹6,600 | 290 ₹5,800 Lowest | 310 ₹6,200 |
| 10.00 | Supplying and fixing of 40 mm dia PVC pipe 10 Kg/cm2 (Shall thickness 2 to 3 mm) of appd. Quality for waste water line including cost of pipe, bend and elbow, labour for cutting, threading, and fixing in position, testing all materials, solution, lead, lift etc., complete. | 11 | RM | 340 ₹3,740 | 300 ₹3,300 Lowest | 318 ₹3,498 |
Tender Value
Refer Docs
EMD Value
₹6,500
Closing Date
1 Jul 2026, 2:00 pmClosed
SE/EGC
SUPERINTENDING ENGINEER ERODE GENERATION CIRCLE URATCHIKOTTAI K.N.PALAYAM (PO) BHAVANI- 638302
Supplying and erection of precast POD toilet FRP septic tank for ladies and Gents and laying water supply sewage arrangements at Tunnel Power Houses Mettur Dam
2026_EB_681123_1
SE/EGC/C/04/26-27/ dt.03.06.26
Open Tender
Civil Works
Works
90 days
Mettur Dam
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹6,500
Yes
7 Oct 2026
16 Jun 2026
2 Jul 2026
16 Jun 2026
1 Jul 2026
16 Jun 2026
16 Jun 2026 - 1 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Earth work excavation in hard stiff clay, stiff block cotton, hard red earth, shales, murram, gravel, stoney earth, earth mixed with small size boulders, hard gravely soil with an initial lead of 10m and lift of 2 m including all lead lift etc., complete. | 17 | Cum | - | - |
| 2 | Plain cement concrete 1:3:6 using 40mm size graded HBG stone including cost of all materials labour, curing charges, lead lift etc., complete. | 2 | Cum | - | - |
| 3 | Brick work in C.M. 1:3 using class II chamber burnt bricks including, cost of cement, all materials, labour, curing, all leads and lifts, as per standard specification etc., complete. | 1 | Cum | - | - |
| 4 | Supply and Installation of Ocean septic tank size BR-20 of standard make and size including cost of transport charges, labour charges for fixing in position, fixing of all PVC joineries, lead, lift, etc. as directed by the Engineer incharge. | 1 | Nos | - | - |
| 5 | Supplying and filling in foundation with M-sand well watered, rammed and consolidated etc., complete complying with standard specification and as directed by the departmental officers. | 4.35 | Cum | - | - |
| 6 | Plastering with CM 1:3 12 mm thick including cost of cement including labour, curing, all leads and lifts etc., complete as per standard specification. | 2.3 | Sqm | - | - |
| 7 | Plastering with CM 1:5, 12mm thick for brick works including cost of all materials, labour, curing charges, all lead & lift etc., complete. | 6 | Sqm | - | - |
| 8 | Supplying and Erection of Precast Toilet POD (Cellcon make) with concrete grade M40SCC, Inner Dimension of POD 1800mm x 1200mm, wall thickness 75mm Base slab thickness 150mm, Roof joineries such as FRP door, fired louver, plumbing fittings such as a wall mounted wash basin floor mounted European water closet, Electrical wiring work complete excluding electrical fittings, painting etc, complete including cost of all materials, labour charges, lead, lift, etc. complete. | 2 | Nos | - | - |
| 9 | Supplying and fixing of 25mm dia UPVC pipe 10Kg/cm2 (Shall thickness 2 to 3mm) for water supply line, including cost of pipe, bend, elbow, labour for cutting, threading and fixing in position, testing all materials, solution, lead, lift etc., complete. | 20 | Rm | - | - |
| 10 | Supplying and fixing of 40 mm dia PVC pipe 10 Kg/cm2 (Shall thickness 2 to 3 mm) of appd. Quality for waste water line including cost of pipe, bend and elbow, labour for cutting, threading, and fixing in position, testing all materials, solution, lead, lift etc., complete. | 11 | RM | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.19 MB
BOQ_818536.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .