| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹15.0 L+₹13,479 (0.90%)Rejected-Finance PANTHAL KATRA REASI J K 182320 | REASI | JAMMU AND KASHMIR | 182320 | L2 | Rejected-Finance Being other than lowest bid | |
| 3 | L3₹15.5 L+₹55,169 (3.70%)Rejected-Finance NEW JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-Finance Being other than lowest bid | |
| 4 | L4₹15.6 L+₹71,304 (4.79%)Rejected-Finance 24 SHANTI BHAWAN DHARI ROAD BELTARI PITHORAGARH UTTARAKHAND 262520 | PITHORAGARH | UTTARAKHAND | 262520 | L4 | Rejected-Finance Being other than lowest bid | |
| 5 | L5₹15.7 L+₹82,529 (5.54%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest bid |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
24 Jun 2024, 6:00 pmClosed
GE NORTH UDHAMPUR
Garrison Engineer (North) Udhampur PIN-901220 C/o 56 APO
GE/U(N)-32/2024-25 REPAIR TO INTERNAL E/M WORKS AND CONNECTED ITEMS AT OLD MEDICAL COMPLEX AND ADJOING AREA UNDER GE (N) UDHAMPUR
2024_MES_652473_1
GE/U(N)-32/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE NORTH UDHAMPUR
Please refer the tender documents
7 documents required · 7 mandatory
₹500
GE NORTH UDHAMPUR
₹60,000
Yes
4 Oct 2024
6 May 2024
26 Jun 2024
6 May 2024
24 Jun 2024
20 May 2024
Amount
Taking down carefully the existing Copper/Aluminium point wiring of any size and type by disconnecting from the either terminals complete with switches, sockets, ceiling rose, regulators, bell etc by unscrewing and removing materials to store for keeping in safe custody for re-use or for taking credit and making good to disturb surface of walls, floors etc., complete all as specified and directed by Engr-in-Charge. Note : (i) Old dismantled wiring and accessories (other than reuse) will be contractors property and credit will be charged against schedule of credit.
Taking down carefully by unscrewing from boards / outlet boxes fittings and fixture such as, LED bulk head fitting, LED tube light fitting etc. for re use at site or carrying to the store (serviceable fitting shall be reuse) all as specified and as directed by engineer in charge.
Taking down Old Serviceable/unserviceable MCB DB any type/size etc after disconnecting (serviceable DBs /MCBs shall be reuse), complete all as specified and directed by engineer in charge.
M&L for Point wiring for One light point controlled by one way switch 5 Amp with 1.5 Sqmm single core multi stranded copper conductor FRLS insulated and unsheathed heavy duty cable in colour code including continuous earth wire with cable of size 1.5 sqmm copper conductor flexible FRLS insulated drawn into and including concealed PVC rigid conduit of not less than 20mm dia and1.5mm wall thickness ISI marked terminated into annealed steel terminal boxes including 3.00 mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and directed by the Engr-in-charge.
M&L for point wiring with 1.5 Sq. mm PVC Insulated unsheathed FRLS multi stranded copper conductor, medium grade ISI meraked drawn into and including PVC concealed conduit with all accessories from terminal box to junction of ceiling and wall and rest of circuit conductor wire drawn in to and including surface PVC rigid non metallic conduit for one ceiling fan point controlled by one switch with and also including 1.5 sqmm continuous earth wire connected to common earth dolly complete all as specified and directed by Engineer-in-Charge.
All as per item No. 04 above but for bell / buzzer on independent board controlled by one push button bell switch.
All as per item Srl No. 04 herein before but for 3 pin socket outlet 5 Amp on same board, complete all as specified and directed by Engr -in-charge.
All as per item No. 04 above but for one 5 Amps socket outlet on independent board.
All as per item No. 04 bove but wire size 2x2.5 Sqmm to controlled the 3 pin 5 / 15 Amps socket outlet on independent board and providing earth continuity wire using PVC insulated, FRLS 1100 volts grade un sheathed single core stranded copper conductor cable of size 2.5 Sqmm.
All as per item No. 04 above but controle by 2 Nos.of two way switch.
M&L Point wiring with multi stranded copper conductor cable, PVC insulated and unsheathed (FRLS) size 1.5 sqmm drawn in and incl PVC casing and caping /PVC conduit with fixing accessories, to be fixed on wooden gutties or plastic rawal plug, for one light /fan/controlled by one switch with thickness not less than 1.25mm annealed steel boxes concealed on wall with and including 3mm thick laminated backlit sheet complete all as directed by Engineer-in-charge.
All as per item No 11 above but for two way point wiring
All as per item No 11 above but for one 3/5 pin socket 5 Amp on same board with cable1.5 sqmm size.
All as per item No 11 above but for one 3/5 pin socket 5 Amp on independent board with cable1.5 sqmm size.
All as per item No 11 above but for 3/5 pins socket outlet 15 Amps independent with 2.5 sqmm incl continuous earthing with multi standred copper conductor PVC insulated unsheathed size 2.5 Sqmm complete all as specified and directed.
All as per item No. 11 above but for bell / buzzer on independent board controlled by one push button bell switch.
S&F Switch Piano flush type single pole 5 Amps One way, all as specified and directed by Engineer- in - Charge. Make : Anchor Penta Cherry of Ordering Code : 14121/ Havells REO Cat No: AHESXXW061
S&F Switch Piano flush type single pole two way 5/15 Amps, all as specified and directed by Engineer- in - Charge. Make : Anchor Penta Cherry of Ordering Code : 14122/Havells REO Cat No: AHESXXW062
S&F Socket outlet Two in one, 3/5 Pin piano type 5 Amp flush type complete all as specified and directed by Engineer- in - Charge. Make : Anchor Penta Ordering Code : 14119/Havells REO Cat No: AHEKSWW063
S&F Switch Piano type single pole 16/20 Amps One way, complete all as specified and directed by Engineer- in - Charge. Make : Anchor Penta Ordering Code : 39991/ Havells REO Cat No: AHESXXW201
S&F Socket outlet Two in one, 3/5 Pin piano type 10 Amp and 20 Amp flush type complete all as specified and directed by Engineer- in - Charge. Make : Anchor Penta Ordering Code : 39994/ Havells REO Cat No: AHESYXW161
S&F Ceiling rose, 3 terminal, PVC / polycarbonate, isolated body complete all as specified and directed by Engineer - in - Charge. Make: Anchor Ordering Code : 39072/ Havells REO Cat No: AHEEIXW000
S&F Electric bell (Ding dong) AC 230/250 volts grade single pole ISI marked, complete all as specified and as directed by engineer in charge Make : Havells REO Ordering code : AHELEXW000/ ANCHOR
S&F switch piano flush type for bell Push 5 Amps, complete all as specified and directed by Engineer- in - Charge. Make : ANCHOR Penta Cherry, Ordering Code : 14123/ Havells REO Ordering code : AHEMBKW061
S&F Electronic type fan regulator Stepped type, 240Volt flush type suitable for 1200/1400mm sweep ceiling fan, ISI marked complete all as specified and directed by Engineer- in - Charge. Make : ANCHOR Penta Cherry, Ordering Code : 14123/ Havells REO Ordering code : AHEMBKW061
Taking down fan, ceiling cable end, dismantling blades and kept in safe custody for refixing on same location all as specified and directed by engineer in charge.
Hanging /fixing only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan obtained from item No 26
Sub main wiring with two run single core 4 sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100V grade including 25mm dia PVC concealed conduit/PVC casing & caping medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 4 sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/distribution board complete including taking down unserviceable submain of any type/size and testing on completion etc fixed in replacement, complete all as specified and directed by engineer-in-charge. Note : Two run of 4 sqmm and one run 4 sqmm cable and one run of PVC conduit shall be measured as one RM
Sub main wiring with two run single core 6 sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100V grade including 25mm dia PVC concealed conduit/PVC casing & capping medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 6 sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/distribution board complete including taking down unserviceable submain of any type/size and testing on completion etc fixed in replacement, complete all as specified and directed by engineer-in-charge. Note : Two run of 6 sqmm and one run 6 sqmm cable and one run of PVC conduit shall be measured as one RM
Sub main wiring with two run single core 1.5 sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100V grade including 25mm dia in PVC concealed conduit/PVC casing & caping medium grade ISI marked with all accessories such as Tees, elbows, junctgion boxes etc, as required fixed on wall alongwith one run of 6 sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/distribution board complete including taking down unserviceable submain of any type/size and testing on completion etc fixed in replacement, complete all as specified and directed by engineer-in-charge. Note : Two run of 1.5 sqmm and one run1.5 sqmm cable and one run of PVC conduit shall be measured as one RM
Sub main wiring with two run single core 2.5 sqmm FRLS copper conductor cable PVC insulated, 1100V grade including 25mm dia in PVC casing & caping medium grade ISI marked with all accessories such as Tees, elbows, junctgion boxes etc, as required fixed on wall alongwith one run of 2.5 sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/distribution board complete including taking down unserviceable submain of any type/size and testing on completion etc fixed in replacement, complete all as specified and directed by engineer-in-charge. Note : Two run of 2.5 sqmm and one run2.5 sqmm cable and one run of PVC casing and capping shall be measured as one RM
Fixing only serviceable MCB DB of any type and capacity obtained from Item No 03 complete all as specified and directed by Engineer-in-Charge.
S&F in replacement single pole and neutral sheet steel powder coated distribution board for MCBs fitted with bus bar neutral link Earth bar and din rail suitable for use on 240V, 50Hz supply double door SPN DB system 4 Way all as specified and directed by engineer in charge. Make : C&S Cat No:CSDBSPNDD08/ Standard Cat No: DSDNSHODXW08/ Indo Asian Cat No : 810321
S&F in replacement single pole and neutral sheet steel powder coated distribution board for MCBs fitted with bus bar neutral link Earth bar and din rail suitable for use on 240V, 50Hz supply double door SPN DB system 8 Way all as specified and directed by engineer in charge. Make : C&S Cat No:CSDBSPNDD08/ Standard Cat No: DSDNSHODXW08/ Indo Asian Cat No : 810321
S&F in replacement single pole and neutral sheet steel powder coated distribution board for MCBs fitted with bus bar neutral link Earth bar and din rail suitable for use on 240V, 50Hz supply double door SPN DB system 12 Way all as specified and directed by engineer in charge. Make : C&S Cat No:CSDBSPNDD12/ Standard Cat No: DSDNSHODXW12/ Indo Asian Cat No : 810323
Supply and fix VTPN MCCB Double door Distribution Board 04 way 415 volts grade IP 43 Protection Grade with provision for (MCCB) as incoming and Three/single phase (TP/SP) outgoings, complete with insulated bus bar arrangement fixed flush to wall complete including connections should be provide with necessary reducer lugs all as specified and directed by Engr-in-Charge. Make : C&S Cat No:CSDBMCCB100DD04IP43S/ Standard Cat No: DSDLVDRBAOFO04/ Indo Asian Cat No : 811888
S & F in repair Thermal magnetic MCCB 4 pole 63 Amps 415 Volts 16 ka INCLUDING MAKING NECESSARY ARRANGEMENT all as specified and directed by engineer in charge for MCCB DB.Make C&S Cat No: CSC2N4/ Indo Asian Cat No: 830022/ or equivalent makes to Standard
S & F in repair Thermal magnetic MCCB 4 pole 100 Amps 415 Volts 16 ka INCLUDING MAKING NECESSARY ARRANGEMENT all as specified and directed by engineer in charge for MCCB DB. Make C&S Cat No: CSC2N4/ Indo Asian Cat No: 830022/ or equivalent makes to Standard
S & F in repair Thermal magnetic MCCB 4 pole 125/160 Amps 415 Volts 16ka INCLUDING MAKING NECESSARY ARRANGEMENT all as specified and directed by engineer in charge for MCCB DB. Make C&S Cat No: CS3A4/ Indo Asian Cat No: 830095 / or equivalent makes to Standard
S&F in repair connection and testing 'C' series SPN MCB 40 to 63 Amp 240V, 50Hz, 10kA for lighting and other domestic loads include necessary copper lugs etc all as specified and as directed by Engineer- in-Charge. Make C&S Cat No: CSMBS2C40/ Indo Asian Cat No: 810078/ or equivalent makes to Standard
S&F in repair 'C' series MCB SP 6-32 Amps. Make C&S Cat No: CSMBS1C6 to CSMBS1C32/ Indo Asian Cat No: 810078/ or equivalent makes to Standard
S&F in repair 'C' series MCB SP 40 Amps. Make C&S Cat No: CSMBS1C40/ Indo Asian Cat No: 810060/ or equivalent makes to Standard
Fixing only serviceable MCB SPN/SP any capacity obtained from item no 03 as above all as specified and as directed by engineer in charge.
Fixing only LED tube light fittings of 5w/12W/20W/2'x2' panel light and LED bulk head fitting 9W as obtained from Srl item No-02 above complete with all fixing accessories.
S&F in repair LED light fitting with high output diffuser 1 feet, 5 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by engineer in charge. Make-C&G Cat Pt- NO-CCS-103-05-65-SLDP-NWH,Havells,Wipro
S&F in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 /12 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-Charge. Make-C&G Cat Pt- NO-CCS-103-10-65-SLDP-NWH,Havells,Wipro
S&F in repair LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by engineer in charge. MAke-C&G Cat Pt- NO-CCS-103-20-65-SLDP-NWH,Havells,Wipro
S&F in repair LED Bulk head (6500K) fitting of 09/10 Watt surface mounting type extruded aluminium body with diffuser complete with testing all as specified and directed by engineer in charge.
S&F in repair surface/recessed mounting LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed by engineer in charge. .Make -Crompton & Greaves, Model-Vector-VIIR,Cat Pt NoLCTLRF7-36-CDL,Havell & wipro
S&F in repair surface/recessed mounting LED down lighter round/square shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-charge. Make -Crompton & Greaves,Model Pearl -R or Proxima-S Cat Pt No-CDR-208-12-30SL-NWH,Havell & Wipro
S&F in repair surface/recessed mounting LED down lighter round/square shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-charge. Make-Crompton & Greaves, Model Pearl -R or Proxima-S Cat Pt No-CDR-208-15-30SL-NWH,Havell & Wipro
S&F in repair for MCB TPN 63 Amp, 415 Volts- C curve of 10kA Make : C&S Cat No: CSMBS3C63N/ Indo Asian Cat No 810098/ Havells
S&F in repair Metal clad Plug socket single pole enclosure with two pin earth plug and socket with one single 20 Amp , 240 volts MCB complete all as specified and directed by Engineer-in-Charge.
S&F in repair Switch Piano flush type single pole two way 5 Amps fixed in replacement, complete all as specified and directed by Engineer- in - Charge. Make : Anchor Penta Cherry of Ordering Code : 14122/Havells REO Cat No: AHESXXW062
S&F in repair Switch Piano flush type single pole 5 Amps one way fixed in replacement, complete all as specified and directed by Engineer- in - Charge. Make : Anchor Penta Cherry of Ordering Code : 14121/ Havells REO Cat No: AHESXXW061
S&F in repair switch piano flush type for bell Push 5 Amps fixed in replacement, complete all as specified and directed by Engineer- in - Charge. Make : ANCHOR Penta Cherry, Ordering Code : 14123/ Havells REO Ordering code : AHEMBKW061
S&F in repair Socket outlet Two in one, 3/5 Pin piano type 5 Amp flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge. Make : Anchor Penta Ordering Code : 14119/Havells REO Cat No: AHEKSWW063
S&F in repair Switch Piano type single pole 16/20 Amps One way, fixed in replacement, complete all as specified and directed by Engineer-in-Charge. Make : Anchor Penta Ordering Code : 39991/ Havells REO Cat No: AHESXXW201
S&F in repair Switch socket combination piano type 5 pin 5 Amps flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge. Make : Anchor Penta Ordering Code : 38820/ Havells REO Cat No: AHETOXW062
S&F in repair Switch socket combination piano type 6 pin 16 Amps flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge. Make : Anchor Penta Ordering Code : 39998/ Havells REO Cat No: AHETOXW204
S&F in repair Switch socket combination box type 5 pin 5 Amps flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge. Make : Anchor Penta Ordering Code : 39998/ Havells REO Cat No: AHETOXW204
S&F in repair Switch socket combination box type 6 pin 16 Amps flush type fixed in replacement, complete all as specified and directed by Engineer- in - Charge. Make : Anchor Penta Ordering Code : 39998/ Havells REO Cat No: AHETOXW204
S&F in repair Ceiling rose, 3 terminal, PVC / polycarbonate, isolated body fixed in replacement, complete all as specified and directed by Engineer-in-Charge. Make: Anchor Ordering Code : 39072/ Havells REO Cat No: AHEEIXW000
S&F in repair Electronic type fan regulator Stepped type, 240Volt flush type suitable for 1200/1400mm sweep ceiling fan, ISI marked fixed in replacement, complete all as specified and directed by Engineer- in - Charge. Make : ANCHOR Penta Cherry, Ordering Code : 14123/ Havells REO Ordering code : AHEMBKW061
S&F in repair Electric bell(Ding dong) AC 230/250 volts grade single pole ISI marked fixed in replacement, complete all as specified and as directed by engineer in charge. Make : Havells REO Ordering code : AHELEXW000/ ANCHOR
S&F in repair Modular fan step regulator 120W 02 module including taking down unserviceable one all as specified and as directed by engineer in charge. Make : Legrand or equivalent to Schnider/Havells
S&F in repair Modular switch 01 way 06A, 01 module including taking down unserviceable one all as specified and as directed by engineer in charge. Make : Legrand or equivalent to Schnider/Havells
S&F in repair Modular switch 01 way 16A, 01 module including taking down unserviceable one all as specified and as directed by engineer in charge. Make : Legrand or equivalent to Schnider/Havells
S&F in repair Modular bell push flush type 6A, 01 module including taking down unserviceable one all as specified and as directed by engineer in charge. Make : Legrand or equivalent to Schnider/Havells
S&F in repair Modular socket, 6A-2/3 pin, 02 module including taking down unserviceable one all as specified and as directed by engineer in charge. Make : Legrand or equivalent to Schnider/Havells
S&F in repair Modular socket, 6A/16A-2/3 pin, 02 module including taking down unserviceable one all as specified and as directed by engineer in charge. Make : Legrand or equivalent to Schnider/Havells
S&F in repair PVC rectangular block for mounting switches, sockets, fan regulator etc. of size 200x150x50mm deep including making necessary cutting all as specified and as directed by engineer in charge, Make Anchor or equivalent to Havells
S&F in repair PVC rectangular block for mounting switches, sockets, fan regulator etc. of size 250x200x50mm deep including making necessary cutting all as specified and as directed by engineer in charge, Make Anchor or equivalent to Havells
S&F in repair 3 mm thick plastic laminated ebonite sheet cover of size 200x150mm including cutting /finishing or making hole for mounting of switches, sockets, regulators etc all as specified and as directed by engineer in charge.
S&F in repair 3 mm thick plastic laminated ebonite sheet cover of size 250x200mm including cutting /finishing or making hole for mounting of switches, sockets, regulators etc all as specified and as directed by engineer in charge.
M&L for disconnecting all Electrical connection from MCB DB TPN/Wall Mounted Panel Box for reconnecting the same with providing proper Copper Bottle Lugs of suitable size and removing the burnt out internal wiring of DB/Panel complete with providing PVC Flexible conduit for Hanging wire complete all as specified and directed by engineer in charge. Note : Replacement Burnt out MCBs of any type/size may be measured and paid separately under relevant Items
Taking down/removing existing damaged cable connection from MCB DB/Wall Mounted Panel Board by making cutting chases on wall/ floor to extend the shorten UG cable of any type/size from Loop and making fresh to reconnect the same with suitable aluminium lugs complete including distribute the load equally on each phase all as specified and directed by Engineer in charge. Note : Cutting of Wall /Floor shall be measured and paid separately.
M&L for Cutting of hard standing n.exc 45 Cm depth, and n.exc 30 Cm width for taking out/laying UG Cable including making good disturbed surface as per existing all as directed .
M&L Earthing complete with galvanised steel earth plate electrode 60x60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-3 of MES Part-1 fixed in replacement including testing on completion including the material and labour of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC Pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of Earthing. Note : (a) On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be done by the contractor at his own risk and cost to the entire satisfaction to the Engineer-in-Charge. (b) The contractor shall quote his rate considering taking down cost of existing unserviceable earthing.
S&F in repair energy saving LED garden light fitting, decorative, bollard type of capacity 9/11 watt with opal diffuser & aluminium reflector complete with all accessories and fixing arrangement on PCC block of size 45mm X 45 mm alogwith fixing nuts, bolts and PVC insulated aluminium conductor, stranded type of size 4.0 sqmm,2 -core including taking down old/unserviceable garden light fittings any type and wattage all as directed. Make - C&S cat pt No- TGLCW9WLED,Havells cat pt No- LHEVBDP7IN6K008,Crompton & Greaves-LPTO-40-CDL-M
Supply and fixing LED street light fitting 25/35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as directed.
Supply& fix in repair driver/ choke suitable for LED panel light fitting 2'x2' 36 watts, 240 volts AC 50 Hz electronic type . Make - Crompton & Greaves/Philips/ Havells/Bajaj/ C&S/C&G
Supply & fix in repair LED street/building light fitting driver/ choke suitable for 25/35 watts, 240 volts AC 50 Hz electronic type. Make - Crompton & Greaves/Philips/ Havells/Bajaj/ C&S/C&G
Supply and fix in repair decorative LED gate light fitting of 30/40 watt,240 volts, die cast aluminium housing in pure polyester powder coated grey finish,top maintainable product with opening die cast cover, anti corrosive stainless steel screws & silicon gasket, HET PMMA diffuser,IP65 protection driver duly prewired up to terminal on firms to IS 10322 part 5/sec, 1 :1987,suitable for pole of dia 65-75 mm in-built electronic driver complete including taking down old/unserviceable gate light fitting complete all as specified and directed .Make - Crompton & Greaves Cat part No -LPT0-40-CDL or equivalent in Bajaj/Havells/C&S/ Philips/Wipro
Supply and lay in replacement XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core in trenches/floor/pole/GI pipe complete including cutting/chasing to any surface and making good to the disturbed surface to match the existing.
DEV RAJ MAGOTRA
SINGH CONST CO
m/s shanti trading company
M/S BHARAT LIGHT ELECRIC.CO
Usha Engineering Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .